• Title/Summary/Keyword: Commission Error

Search Result 60, Processing Time 0.019 seconds

CORRELATION STUDY BETWEEN THE SCORES OF KEDI-WISC SUBSCALES AND THE SCORES OF ADS VARIABLES (KEDI-WISC의 각 소검사 점수와 ADS 점수간의 상관관계 연구)

  • Kim Eun-Yee;Cho Ara;Kim Bongseog
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.16 no.1
    • /
    • pp.90-97
    • /
    • 2005
  • Objectives : The present study was conducted to investigate a correlation of ADS and KEDI-WISC measures. Methods : The data of 91 children were used. On KEDI-WISC, PIQ, VIQ, and 11 subtest measures, and on ADS, 4 variables (ommission error rate, commission error rate, response time mean, and response time deviation) were analyzed. Results : The correlations of Ommission Error Rate and Coding, Digit Span, and Arithmetic, the correlations of Commission Error Rate and Object assembly, Picture Completion, Arithmetic, Digit Span, and Coding, the correations of Response Time Mean and Coding, and the correlations of Response Time Deviation and PIQ, and Coding were significant. Conclusion : ADS variables and several IQ scores are significantly related.

  • PDF

SACADA and HuREX: Part 1. the use of SACADA and HuREX systems to collect human reliability data

  • Chang, Yung Hsien James;Kim, Yochan;Park, Jinkyun;Criscione, Lawrence
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1686-1697
    • /
    • 2022
  • As a part of probabilistic risk (or safety) assessment (PRA or PSA) of nuclear power plants (NPPs), the primary role of human reliability analysis (HRA) is to provide credible estimations of the human error probabilities (HEPs) of safety-critical tasks. Accordingly, HRA community has emphasized the accumulation of HRA data to support HRA practitioners for many decades. To this end, it is critical to resolve practical problems including (but not limited to): (1) how to collect HRA data from available information sources, and (2) how to inform HRA practitioners with the collected HRA data. In this regard, the U.S. Nuclear Regulatory Commission (NRC) and Korea Atomic Energy Research Institute (KAERI) independently initiated two large projects to accumulate HRA data by using full-scale simulators (i.e., simulator data). In terms of resolving the first practical problem, the NRC and KAERI developed two dedicated HRA data collection systems, SACADA (Scenario Authoring, Characterization, And Debriefing Application) and HuREX (Human Reliability data EXtraction), respectively. In addition, to inform HRA practitioners, the NRC and KAERI proposed several ideas to extract useful information from simulator data. This paper is the first of two papers to discuss the technical underpinnings of the development of the SACADA and HuREX systems.

A Total Survey Error Analysis of the Exit Polling for General Election 2008 in Korea (2008 총선 출구조사의 총조사오차 분석)

  • Kim, Young-Won;Kwak, Eun-Sun
    • Survey Research
    • /
    • v.11 no.3
    • /
    • pp.33-55
    • /
    • 2010
  • In this study, we newly define the Total Survey Error(TSE) in exit poll and investigate the TSEs of the exit poll survey for the 18th general election of 2008 to analyse the cause of the exit poll prediction error. To explore the main cause and effect of the total survey error, the total survey error was divided by the sampling error which comes from sampling process of poll stations and the non-sampling error which comes from selecting voter and collecting responses from sampled voters in each electoral district. We consider the relationship between non-response rates and total survey error as well as non-sampling error. Also, we study the representativeness of the exit poll sample by comparing the sex/age distribution of the exit poll data and the National Election Commission poll data.

  • PDF

A classification of electrical component failures and their human error types in South Korean NPPs during last 10 years

  • Cho, Won Chul;Ahn, Tae Ho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.709-718
    • /
    • 2019
  • The international nuclear industry has undergone a lot of changes since the Fukushima, Chernobyl and TMI nuclear power plant accidents. However, there are still large and small component deficiencies at nuclear power plants in the world. There are many causes of electrical equipment defects. There are also factors that cause component failures due to human errors. This paper analyzed the root causes of failure and types of human error in 300 cases of electrical component failures. We analyzed the operating experience of electrical components by methods of root causes in K-HPES (Korean-version of Human Performance Enhancement System) and by methods of human error types in HuRAM+ (Human error-Related event root cause Analysis Method Plus). As a result of analysis, the most electrical component failures appeared as circuit breakers and emergency generators. The major causes of failure showed deterioration and contact failure of electrical components by human error of operations management. The causes of direct failure were due to aged components. Types of human error affecting the causes of electrical equipment failure are as follows. The human error type group I showed that errors of commission (EOC) were 97%, the human error type group II showed that slip/lapse errors were 74%, and the human error type group III showed that latent errors were 95%. This paper is meaningful in that we have approached the causes of electrical equipment failures from a comprehensive human error perspective and found a countermeasure against the root cause. This study will help human performance enhancement in nuclear power plants. However, this paper has done a lot of research on improving human performance in the maintenance field rather than in the design and construction stages. In the future, continuous research on types of human error and prevention measures in the design and construction sector will be required.

A Study on Red Tide Detection Algorithm Based on Two Stage filtering - Application to MODIS Chlorophyll Information - (2단계 필터링 기반 적조 탐지 알고리즘에 관한 연구 - MODIS 클로로필 정보에 적용 -)

  • Kim, Yong-Min;Kim, Hyung-Tae
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.325-331
    • /
    • 2008
  • We propose an algorithm to detect large Cochlodinium polykrikoides red tide event that was appeared in Korean coastal waters. This algorithm is based on two-stage filtering using MODIS chlorophyll information. Most of the red tide detection studies generally use assumption that sea water having high chlorophyll concentration is red tide events because of high correlation and red tide. However, these methods generate many commission errors such as turbid water by detecting inactive sea water of red tide. Therefore, we eliminated commission errors by applying two stage filtering and verified the algorithm's effectiveness by detecting large Cochlodinium polykrikoides red tide event that was appeared in Korean coastal waters.

RELATIONSHIP BETWEEN CHANGES IN EVENT-RELATED POTENTIALS AND CHANGES IN CONTINUOUS PERFORMANCE TEST UNDER THE INFLUENCE OF METHYLPHENIDATE IN ATTENTION-DEFICIT/HYPERACTIVITY DISORDER (주의력 결핍 ${\cdot}$ 과잉행동장애 아동에서 Methylphenidate에 의한 사건관련전위와 연속과제수행 변화사이의 상관성)

  • Choi, Young;Lee, Mu-Suk;Lee, Mi-Suk
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.273-286
    • /
    • 1997
  • Objective:This study was designed to evaluate effects of methylphenidate(MPH) on event-related potentials(ERP) and continuous performance test(CPT) in attention-deficit hyperactivity disorder (ADHD) and to see the correlation between changes in ERP and changes in performance. Method:ERP and CPT were used to examine the acute effects of MPH(0.5mg/kg) in eleven ADHD boys(89-103 months old). Results:1) After MPH administration, P3 latency to nontarget stimuli at Fz was significantly decreased (p<0.01) and P2 amplitudes to target stimuli at Pz and at Oz and P3 amplitude to target stimuli at Cz were significantly increased(p<0.05). 2) Commission error and omission error in the CPT-X and commission error in the CPT-AX were decreased(p<0.01), and hits and perceptual sensitivity(d') in the CPT-X and d′ in the CPT-AX were increased(p<0.01). 3) The change of P3 latency to nontarget stimuli at Fz and the change of d′ in the CPT-X were negatively correlated(p<0.05), and the change of P2 amplitude to target stimuli at Pz and d′ in the CPT-AX were positively correlated(p<0.05). Conclusion:MPH improves change orienting reaction, the delivery of task relevant information, accuracy and perceptual sensitivity in ADHD. And the increase of ability to discriminate targets from non-targets reflects reduced evaluation time in large memory component task and enhanced change orienting reaction in simple task.

  • PDF

Characteristics of Optical Current Sensors by Sensor Design

  • Kim, Young-Min;Park, Jung-Hwan;Lee, Kwang-Sik;Kim, Jung-Bae;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.80-87
    • /
    • 2007
  • This paper will suggest that the 1 cross orthogonal loop type sensor improves on the orthogonal loop form sensor-head, which is available a calibration of the linear birefringence, when a fiber optic current sensor was composed. An output characteristics of the 1 cross orthogonal loop form, a general closed loop form, the orthogonal loop form are compared by the IEC(International Electrotechnical Commission) 60044-8 standard, and the state of polarization is compared with three forms. As a result, when the closed loop form was changed to the orthogonal loop form, retardation decreased 15.3[%]. When the closed loop form was changed to the 1 cross orthogonal loop type, the retardation decreased 33.8[%]. As a result of the Faraday Effect measurement, the 1 cross orthogonal loop form has the highest output characteristic and the lowest error ratio. It met the 0.5 class of the IEC 60044-8 standard. Thus, in application of the 1cross orthogonal loop form, the possibility to develop high reliability fiber optic current sensors that have a high output and stable error ratio rises is increased.

A Study on Prediction Method of Sky Luminance Distributions for CIE Overcast Sky and CIE Clear Sky (CIE 표준 담천공과 청천공 모델의 천공 휘도분포 예측 방법에 관한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.33-43
    • /
    • 2016
  • Daylight is an important factor which influences building energy efficiency and visual comfort for occupants. It is important to predict precise sky luminance at the early stages of design to reduce light energy in the building. This study predicted sky luminance distributions of standard sky model(CIE overcast sky, CIE clear sky) that was provided from the CIE(Commission internationale de $l^{\prime}{\acute{e}}clairage$). Afterward, result of sky luminance was compared and verified with simulation value of Radiance program. From the CIE overcast sky, zenith and horizon ratio is about 3:1. From the CIE clear sky, luminance value gets most high value around the sun. On the other hand, luminance value is the lowest in the opposite direction of the sun when angle is $90^{\circ}$ between the sun and sky element. As a result of comparing the calculation results with Radiance program, sky luminance prediction error rate is 0.4~1.3% when it is CIE overcast sky. Also, sky luminance prediction error rate is 0.3~1.5% when it is CIE clear sky. When compared with the results of radiance simulation, it was evaluated as fairly accurate.

Novel Spectrally Efficient UWB Pulses Using Zinc and Frequency-Domain Walsh Basis Functions

  • Chaurasiya, Praveen;Ashrafi, Ashkan;Nagaraj, Santosh
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.397-405
    • /
    • 2013
  • In this paper, two sets of spectrally efficient ultra-wideband (UWB) pulses using zinc and frequency-domain Walsh basis functions are proposed. These signals comply with the Federal Communications Commission (FCC) regulations for UWB indoor communications within the stipulated bandwidth of 3.1 GHz to 10.6 GHz. They also demonstrate high energy spectral efficiency by conforming more closely to the FCC mask than other UWB signals described in the literature. The performance of these pulses under various modulation techniques is discussed in this paper, and the proposed pulses are compared with Gaussian monocycles in terms of spectral efficiency, autocorrelation, crosscorrelation, and bit error rate performance.

DEVELOPMENT OF POINT KERNEL SHIELDING ANALYSIS COMPUTER PROGRAM IMPLEMENTING RECENT NUCLEAR DATA AND GRAPHIC USER INTERFACES

  • Kang, Sang-Ho;Lee, Seung-Gi;Chung, Chan-Young;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.215-224
    • /
    • 2001
  • In order to comply with revised national regulationson radiological protection and to implement recent nuclear data and dose conversion factors, KOPEC developed a new point kernel gamma and beta ray shielding analysis computer program. This new code, named VisualShield, adopted mass attenuation coefficient and buildup factors from recent ANSI/ANS standards and flux-to-dose conversion factors from the International Commission on Radiological Protection (ICRP) Publication 74 for estimation of effective/equivalent dose recommended in ICRP 60. VisualShieid utilizes graphical user interfaces and 3-D visualization of the geometric configuration for preparing input data sets and analyzing results, which leads users to error free processing with visual effects. Code validation and data analysis were performed by comparing the results of various calculations to the data outputs of previous programs such as MCNP 4B, ISOSHLD-II, QAD-CGGP, etc.

  • PDF