• Title/Summary/Keyword: Commercial Fire

Search Result 178, Processing Time 0.028 seconds

Measurements of the Heat Release Rate and Fire Growth Rate of Combustibles for the Performance-Based Design - Focusing on the Plastic Fire of Commercial Building (성능위주설계를 위한 가연물의 열발생률 및 화재성장률 측정 - 판매시설의 플라스틱 화재를 중심으로 -)

  • Jang, Hyo-Yeon;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.55-62
    • /
    • 2018
  • To improve the prediction result with enhanced reliability of domestic Performance-Based Design (PBD), actual scale fire tests were carried out on products made of plastics from sales facility combustibles. The commercial buildings were separated into single and multiple combustibles for the experimentation of fire spread caused by the sales shelves where the various combustible materials are displayed. A according to the maximum heat release rate, exposed area and weight of the combustible material, the results revealed a linear relationship of as 93% and 89%. In addition, analysis of the gas concentrations for various combustibles showed that $CO_2$ has a linear relationship, whereas the CO concentration indicated exponential function. These results can be applied to reliable fire source information in PBD of plastic fire source in commercial buildings. This may be applied as fire source information representative of a plastic fire in commercial buildings through additional experiment using the area of the shelf in actual commercial buildings.

An Analysis of the Fire Load and Ventilation Factor in Underground Commercial Space (지하상업공간의 환기계수 및 화재하중 분석)

  • Choo Yeun-Hee;Lee Ji-Hee;Hong Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.135-142
    • /
    • 2006
  • The purpose of this study is to obtain the fire safety for underground commercial space with analysing fire loads and ventilation factors. It was adopted the investigation method of field survey with commercial uses for more confidential data. The results of this study can be summarized as follows; 1) The ventilation factor shows $0.04{\sim}0.24m^{1/2}$ and it may develop ventilation-controlled fires which have much fire hazard more than fuel-controlled fires. 2) The highest value of fire load is $158.48kg/m^2$ and appeared in footwear shop which has the value $137.35kg/m^2$ for unfixed combustibles and $21.13kg/m^2$ for fixed combustibles. 3) The average value of burning rates which mean the velocity of fire development and the fire damage range is 0.143. Therefore it is desired to decrease the combustibles of compartment and is needed the method of dispersion arrangement of goods and storage to steel cabinet and so on.

An Investigation on the Existing Literature to Prevent Fire Spread of High-rise Buildings (고층 건축물의 화재확대방지를 위한 기존 문헌 조사)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.102-103
    • /
    • 2021
  • In Korea, starting with the Busan residential-commercial fire in 2010, the frequency of fire expansion in high-rise buildings has been continuously increasing. In the case of such large-scale fires, most of the fires generated from the inside tend to expand to the upper floors by riding the exterior material or exterior wall panels through the process of being ejected to the outside. It has been revised so that combustible exterior materials cannot be used in buildings. However, due to the legal fluoride level, the fire risk of high-rise buildings is still high, such as the case of a 33-story residential-commercial fire in Ulsan. In order to prevent such fire expansion, it is considered that it is necessary to first understand the nature of the fire occurring inside and the mechanism of the fire expansion in the upper floor. The purpose of this study is to propose improvements in domestic fire safety design through a review of existing literature to prevent fire expansion of high-rise buildings.

  • PDF

A Study on the Improvement of Human Safety Standards Considering Fire Cases in High-rise Residential Facilities (고층 주거시설 화재사례를 고려한 인명안전기준 개선방안에 관한 연구)

  • Cho, Hwi-Je;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.106-107
    • /
    • 2021
  • The fire in Ulsan in 2020 was a 33-story residential and commercial complex with about 90 injuries and more than 10 billion won in property damage, and considering the recent increase in high-rise residential and commercial complexes, the risk of similar fires is high. As can be seen through the residential and commercial complex fire case in Ulsan, life-based fire safety standards need to be established to minimize casualties. Therefore, the purpose of this study is to draw improvements for the development of human safety standards for high-rise residential facilities in the future through comparison with the Korean Building Act, Firefighting-rellated Acts and the U.S. NFPA 101.

  • PDF

Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network (인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가)

  • Darkhanbat, Khaliunaa;Heo, Inwook;Choi, Seung-Ho;Kim, Jae-Hyun;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.111-120
    • /
    • 2021
  • When a fire occurs in a commercial building, the evacuation route is complicated and the direction of smoke and flame is similar to that of the egress route of occupants, resulting in many casualties. Performance-based evacuation design for buildings is essential to minimize human casualties. In order to apply the performance-based evacuation design to buildings, it requires a complex fire simulation for each building, demanding a large amount of time and manpower. In order to supplement this, it would be very useful to develop an Available Safe Egress Time (ASET) prediction model that can rationally derive the ASET without performing a fire simulation. In this study, the correlations between fire temperature with visibility and toxic gas concentration were investigated through a fire simulation on a commercial building, from which databases for the training of artificial neural networks (ANN) were created. Based on this, an ANN model that can predict the available safe egress time was developed. In order to examine whether the proposed ANN model can be applied to other commercial buildings, it was applied to another commercial building, and the proposed model was found to estimate the available safe egress time of the commercial building very accurately.

The Proposal of Installations Standards for Commercial Kitchen Automatic Fire System (상업용 주방자동소화장치 도입과 설치기준 제안)

  • Lee, Changwoo;Kang, Dowoo;Oh, Seungju;Ham, Eungu;Cho, Yongsun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.89-97
    • /
    • 2016
  • According to the statistics released by Ministry of Public Safety and Security, the number of restaurant fires in Korea reached around 2,400 and 169 damages of human life and damages to property was approximately over $8.8 billion for recent 3 years. It could be desirable having automatic commercial fire-extinguishing equipment at commercial facilities excluding housing facilities for the safety, applying at the place first where it has been more risky and expected fire can be occurred relatively because economical burden can be accelerated. In order to do this, adjust its level to meet the same level of the kitchen for 'Specific Target for Fire Fighting' that "gas leak alarm" has be equipped relevant regulations and it is considered and reasonable to expand the limit of application gradually.

Analysis of fires case through on-field survey of residential and commercial building in Ulsan (울산 주상복합건물 현장조사를 통한 화재사례 분석)

  • Cho, Hwi-Je;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.84-85
    • /
    • 2021
  • The fire that broke out in a residential and commercial complex in Ulsan in October 2020 was large, but no deaths occurred. For this reason, there was a difference from the previous cases, so it was analyzed through field survey. The fire was expanded to the entire building by aluminum composite panels constructed by external heat method and SMC panels in evacuation safety zones, and fire was expanded to nearby mart due to wind on the day of the fire, and there were many evacuation spaces such as 15th, 28th, and rooftop heliports.

  • PDF

Development and Performance of Cementitious Materials for Fire Resistance of Tunnel (터널 내화용 시멘트계 재료의 개발 및 성능 평가)

  • Won, Jong Pil;Choi, Seok Won;Park, Chan Gi;Park, Hae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4C
    • /
    • pp.265-273
    • /
    • 2006
  • This study aims at evaluation of the fire resistance performance of cementitious materials for fire protection of tunnel. For this purpose, the research procedure was divided into three parts. First, base mix proportion with different material type were determined by fire test. Second, the fire test of cementitious materials for fire resistance were performed on base mix proportions to evaluated their performance. Third, the performance of cementitious materials for fire resistance compare to the target value and existing commercial products. If the performance of developed cemetitious materials for fire resistance were satisfied the target value, this studies were stopped. But, this research return to first process if the performance of cementitious materials for fire resistance are not satisfied the target value. As a result of this study, the spalling did not happen for develop and existing commercial product. Also, developed cementitious materials for fire resistance are shown with excellent compressive strength, flexural strength, and bond strength, because it used a height density aggregate. And developed cementitious materials has sufficient resistance for fire.

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Bookstore - (건축물의 적재가연물 특성에 관한 연구 -대형서점의 적재가연물 연소발열성상-)

  • Nam, Dong-Gun;Yuji, Hasemi;Jung, Jong-Jin;Lim, Woo-Sub;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.3-6
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book.

  • PDF

Evaluation of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance (내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 저항성 평가)

  • Won, Jong-Pil;Choi, Seok-Won;Park, Chan-Gi;Park, Hae-Kyun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.559-568
    • /
    • 2006
  • The purpose of this study is to evaluate the mechanical performance and fire resistance of wet-mixed high strength sprayed polymer-modified mortar in order to protect tunnel lining system which are in the event of fire disaster. Since the current commercial fire-resistant materials reproduce the low strength issue of mortar, this study aims to provide an enhanced fire-resistant mortar with a proper strength. Normally, a large temperature gradient phenomenon arise in the vicinity of free surfaces which are fully exposed in the event of persistent flame. Thereby, the determination of optimal cover depth of wet-mixed high strength sprayed polymer-mortar(WHSPM) is important for fire-resistance of tunnel lining system. With comparison of current commercial fire-resistance materials and WHSPM, the experimental result of WHSPM shows the better fire-resistant performance than the others. In addition, the cover limitation should be controlled by minimum 4cm depth in order to avoid fire-induced damage.