생활특성에 따른 바닥복사난방 공간의 열쾌적 범위에 관한 연구 (Thermal Comfort Range of Radiant Floor Heating System by Residential Style)

  • 김상훈;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권1호
    • /
    • pp.7-14
    • /
    • 2015
  • This study has been purposed to provide thermal comfort range in accordance with the residential style of radiant floor heating space, and to compare it with the thermal comfort range at predicted mean vote. The survey for the thermal sensation vote to the subjects and the measurement of environmental factors has been executed, and regression analysis has been performed. It is interpreted that the combination of the physical factor and the psychological factor results lower neutral point of the floor sitting style than that of the chair sitting style. There are some difference between the measured predicted mean vote and the thermal sensation vote via survey, which appears to be caused by distinctive heat transfer characteristic of floor radiant heating space, such as, high radiant temperature and contact thermal sensation of floor surface.

Thermal Comfort Condition of Temperature and Humidity in Loess Interior Space

  • Kong, Sung-Hoon
    • 대한의생명과학회지
    • /
    • 제10권2호
    • /
    • pp.129-135
    • /
    • 2004
  • The study was carried out through measuring the temperature and humidity of the indoor/outdoor space and the distribution of interior thermal condition, and investigating the effect of loess materials on human body. The purpose of this study is to analyze the change of dry bulb temperature and relative humidity and correlation of thermal reaction of human body with ASHRAE (American Society of Heating, Refrigerating and Air-conditioning) comfort chart in the loess interior space. In the view point of biomedical sciences, loess interior space provides optimum thermal conditions for human thermal sensation.

  • PDF

비타민 E 소재의 인체생리반응 및 쾌적성 평가 (Evaluation of Thermal Physiological Responses and Comfort in Vitamin E Fabric)

  • 임순;정명희
    • 복식문화연구
    • /
    • 제13권3호
    • /
    • pp.406-413
    • /
    • 2005
  • This study performed the evaluation of skin temperature, heart rate, temperature and relative humidity of microclimate, and subjective sensation, such as thermal sensation, wet sensation and comfort sensation to estimate physiological responses of the human body and its comfortable feeling to the vitamin E fabric. Experiments were performed on the five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $30{\pm}\;1^{\circ}C$, $50{\pm}\;15\%$ and 0.2m/s, respectively. Two kinds of clothes were used for experiments: unfinished sports clothes, with the same form and the same size, of short-sleeved knit shirt and long trousers made with $100\%$ cotton, and finished sports clothes printed with the vitamin E solution of the level of $0.88\%$. Exercises of walking (about 105 steps/minute) with the exercise intensity of 2.5 were performed for 20 minutes using treadmill. In result, the study showed significant difference (p<0.01) in average skin temperature between unfinished and finished sport clothes, and represented higher value with having unfinished sport clothes in wear than with finished one. The study also showed significant difference (p<0.01) in heart rate only during the period of exercise, and represented higher value generally with unfinished sport clothes than with finished one. There were significant differences not only in temperature of microclimate (p<0.01) but also in humidity of microclimate (p<0.05) between two sport clothes. As for the evaluation of subjective sensation, the study showed significant difference (p<0.05) in thermal sensation between the two kinds of sport clothes, significant difference in wet sensation only during the period of exercise, and significant difference (p<0.05) in comfort sensation only during the period of recovery.

  • PDF

여름철 사무실내 한국인의 온열감 평가 (Evaluation of Korean Thermal Sensation in Office Buildings During the Summer Season)

  • 배귀남;이철희;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.341-352
    • /
    • 1995
  • In this study, thermal parameters were measured and 213 occupants were also questioned in three office buildings located in Seoul during the summer season. Predicted mean vote-predicted percentage of dissatisfied(PMV-PPD) and standard new effective temperature(SET*) were used for evaluating Korean thermal sensation. The distribution of thermal sensation vote(TSV) and percentage of dissatisfied(PD) is very similar to that of PMV and PPD. By regression analysis, the following regression equation was obtained; TSV=0.339SET*-8.583. In this case, neutral temperature and comfort range are $25.3^{\circ}C$, $23.8{\sim}26.8^{\circ}C$ respectively. Present experimental results obtained from the field study is less sensitive to the temperature change than those obtained from the climate chamber study in Korea. But, thermal sensations are similar to each other near the neutral point. The neutral temperature and comfort range obtained by this experiment are higher than those of ANSI/ASHRAE Standard 55-1974 about $1.4{\sim}1.8^{\circ}C$.

  • PDF

겨울철 잠옷의 주관적 착용감과 잠옷 소재의 쾌적성능 (Subjective Wearing Sensation of Sleepwear and Comfort Properties of the Fabrics in Winter)

  • 권수애;최종명
    • 대한가정학회지
    • /
    • 제40권3호
    • /
    • pp.11-20
    • /
    • 2002
  • The purposes of this study were to investigate the subjective wearing sensation of sleepwear, and to evaluate the comfort properties of fabrics used in the sleepwear. Design of experimental clothing was pajamas made with four types of woven fabrics: plain weave and satin weave made by cotton and polyester. The comfort properties were evaluated with respect to thermal retention, Qmax, moisture regain, water vapor transmission, and air permeability. The wear trials of experimental clothing were performed in two different environments, single-detached unit($23{\pm}1^{\circ}C$, $45%{\pm}3%$ R.H.) and apartment($27{\pm}1^{\circ}C$, $40{\pm}3%$ R.H), to evaluate microclimate temperature and humidity, and subjective wearing sensation. The results obtained from this study were as follows: 1. There were significant differences between the two environments on the clothing microclimate. 2. In the single detached unit environment, the microclimate temperature who wore cotton sleepwear was significantly higher than that of subjects wore the polyester sleepwear, whereas the microclimate humidity who wore polyester sleepwear was higher than that of subjects wore the polyester sleepwear. 3. In the apartment environment, the microclimate temperature who wore the polyester sleepwear showed higher than that of cotton sleepwear, whereas there was no significant difference between the cotton and polyester sleepwear on the microclimate humidity. 4 There were partially significant differences in subjective wearing sensation according to the fiber md weaving type of sleepwear regardless environment. 5. There were also partially significant correlations among the heat/moisture transmission properties of fabrics, the clothing microclimate and the subjective wearing sensation of sleepwear.

피복재료의 물리적특성과 주관적착용감과의 관계연구 (A Study on Relationship of Fabric Physical Properties and Subjective Properties for Clothing Comfort)

  • 최철호;박우미
    • 한국의류학회지
    • /
    • 제10권2호
    • /
    • pp.29-35
    • /
    • 1986
  • The main purpose of the study was to investigate relationships between subjective evaluation of comfort/discomfort and tactile sensation. It was also attempted to analyse physical properties of fabric, hence to find physical factors which have effects on wearing- comfort. The results were as follows; 1. Polyester fabric B Type ranked the highest on subjective comfort scale of T-shirts. 2. Scratchiness and flexural rigidity among subjective factors were important on overall comfort sensations of the subjects. 3, In winter, subjective factors, suchas Soratchiness, Heaviness & Flexural Rigidity, were significantly correlated with objective factors of Scratchiness, Thickness & Weight, Stiffness, respectively. 4. In summer, subjective factors such as warmth, Heaviness, Clammy & Cling Tension, Flexural Rigidity, were significantly correlated with objective factors of Thermal Insulation, Thickness & Weight, Cling Tension and stiffness, respertively. 5. Scratchiness, Weight, Stiffness & Thermal Insulation among objective factors were important on overall comfort sensation of the subjects.

  • PDF

The Psycho-physiological Response of Polyethylene Terephthalate Irradiated by Ultra-Violet: Subjective Fabric Hand and Wear Comfort

  • Choi, Hae-Young;Lee, Jung-Soon
    • Fibers and Polymers
    • /
    • 제7권4호
    • /
    • pp.442-445
    • /
    • 2006
  • The purpose of this study was to compare the subjective fabric hand evaluation and wear comfort of PET treated by Ultraviolet and to evaluate the subjective results from the investigation of microclimate temperature. The subjective hand evaluation was performed by 20 subjects (age: 20-25) with 5-point scale questionnaires to investigate the change of PET knit fabrics treated for different times, specifically, 0, 30 and 90 minutes. The questionnaires were composite with 8 questions; roughness, smoothness, wetness, stiffness, coolness, touch, preference, and comfort. In order to evaluate sensations of wear comfort, we made garments with UV treated fabric and five female students were tested. They walked at the speed of 6.7 km/ hr for 15 minutes in an environment, which was controlled at $29^{\circ}C,\;75{\pm}5%$ RH. Before and after exercising, the microclimate under clothing and subjective wear comfort was measured. The results of subjective evaluation of fabric hand were that untreated and treated for 30 minutes PET were recognized as similar and have a good evaluation on comfort, preference, and touch. According to the result of wear comfort, clothing treated by UV for 90 minutes had the lowest value on the thermal and humidity sensations. In addition, the value of tactile and comfort sensation was the highest on the clothing treated by UV for 90 minutes. In the case of objective evaluation, PET treated for 90 minutes was the lowest on microclimate humidity. PET irradiated by UV for 90 minutes was more 'cool' in thermal sensation and more 'dry' in wet sensation. Accordingly, it was consistent with the result of subjective wear comfort.

PCM 마이크로캡슐을 이용한 열조절 섬유소재 개발 -열조절 섬유소재의 착용효과- (Development of Thermoregulating Textile Materials with Microencapsulated Phase Change Materials(PCM) -Wearing comfort of the developed thermoregulating textile materials-)

  • 신윤숙;정영옥;전향란;손경희;김성희
    • 한국의류학회지
    • /
    • 제28권6호
    • /
    • pp.767-775
    • /
    • 2004
  • In order to evaluate physiological responses and comfort sensation of the developed thermoregulating textile material, polyester knit fabric was treated with phase change material (PCM) microcapsules by printing. Ten male subjects wearing an experimental best with and without PCMs were seated for 20 minutes, then exercised for 20 minutes, and then seated for 30 minutes in the chamber which was controlled under the temperatures of 20$\pm$1$^{\circ}C$, 50$\pm$5%R.H. The subject's skin temperature, microclimate inside garment and comfort sensation of two experimental bests were compared one another. As a result, the rectal temperature, skin temperature and mean skin temperature were similar in the two groups, and the subjects were not able to perceive the differences in comfort of the two experimental bests. However, the effect of PCM microcapsule could be seen from microclimate temperature and humidity. The microclimate temperature of the PCM garment at chest was significantly higher during exercise. The microclimate humidity of the PCM garment at chest was significantly lower during exercise and rest.

에어컨 장시간 운전시 온열쾌적감 평가에 관한 연구 (The Analysis for Thermal Comfort Evaluation during long time operating Air Conditioner)

  • 김동규;박종일;김세환
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.59-64
    • /
    • 2007
  • Using air conditioner has been increased in home or office buildings in summer. Also various problems related to air conditioning such as disease induction happened by using air conditioner excessively and operating long. Active operation control is needed for occupant's health when air conditioner operates long. We should think ahead to acquire thermal comfort of occupants which represents psychological and physiological reaction for this operation. Research has been progressed to observe activity of autonomic nervous system by trying to quantitate change of thermal comfort. In this study, questions of the subject and change of body's autonomic nervous system were chosen to evaluate thermal comfort during operation of air conditioner for a long time. Electrocardiogram and questions of the subject which is the progress of changing TSV and CSV by occupants indoor were measured when room air conditioner is operated for a long time, and an air-conditioned adaptability of human body was evaluated by acquiring the change rate of autonomic nervous system through analyzing HRV. As a result of the evaluation, change rate of body's autonomic nervous system corresponded to votes of the subject's question generally, but was distinguished from analysis result of warm-cold sensation in a low temperature area.

투습방수의류의 착용쾌적성 평가 (Assessment of Wear Comfort of Water-vapor-permeable (WVP) garments)

  • 강인형;박효숙;이한섭
    • 한국의류학회지
    • /
    • 제36권9호
    • /
    • pp.928-939
    • /
    • 2012
  • This study evaluates wear comforts of water-vapor-permeable (WVP) garments through a measurement of various parameters such as skin and rectal temperatures, microclimate between skin and clothing, sweat rate, and subjective sensations (thermal, wet and comfort sensations) to correlate the physiological responses of the human body with its comfort feeling. Wear comfort during a specific exercise on a treadmill in a climatic chamber (temperature T = $20{\pm}0.5^{\circ}C$ and relative humidity H = $50{\pm}10%$) were studied using eight men wearing seven sportswear outfits (a long sleeve shirts and a long pants) made with seven different WVP fabrics. A comfort sensation was found to be highly correlated with skin T (p<.001), microclimate (T and H) between skin and clothing (p<.001) and sweat rate (p<.05). A regression model correlating comfort sensations and physiological responses obtained from wearer trials could be established: Y = 14.167 - 0.362 ${\times}$ X1 + 0.424 ${\times}$ X2 - 0.238 ${\times}$ X3 - 0.561 ${\times}$ X4 + 0.253 ${\times}$ X5 + 0.214 ${\times}$ X6 - 0.393 ${\times}$ X7 + 0.023 ${\times}$ X8 - 0.043 ${\times}$ X9. (Y = comfort sensation, X1 = forehead skin T, X2 = forearm skin T, X3 = hand skin T, X4 = thigh skin T, X5 = T of chest microclimate, X6 = T of thigh microclimate, X7 = chest sweat rate, X8 = H of back microclimate, X9 = H of thigh microclimate. The regression model obtained in this work can be used by manufacturers to objectively estimate the comfort sensation of sportswear before it is introduced to the consumer market. This study provides salient information to sportswear manufacturers and sportswear consumers.