• Title/Summary/Keyword: Combined Heat & Power

Search Result 327, Processing Time 0.025 seconds

The Figures for the Alstom Power Pressurized Fluidized Bed Combustion Combined Cycle System (Alstom Power의 가압유동층 복합발전 시스템 특성)

  • 이윤경;주용진;김종진
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • Pressurized fluidized bed combustion unit is operated at pressures of 1~1.5 MPa with combustion temperatures of 850~87$0^{\circ}C$. The pressurized coal combustion system heats steam, in conventional heat transfer tubing, and produces a hot gas supplied to a gas turbine. Gas cleaning is a vital aspect of the system, as is the ability of the turbine to cope with some residual solids. The need to pressurize the feed coal, limestone and combustion air, and to depressurize the flue gases and the ash removal system introduces some significant operating complications. The proportion of power coming from the steam : gas turbines is approximately 80:20%. Pressurized fluidized bed combustion and generation by the combined cycle route involves unique control considerations, as the combustor and gas turbine have to be properly matched through the whole operating range. The gas turbines are rather special, in that the maximum gas temperature available from the FBC is limited by ash fusion characteristics. As no ash softening should take place, the maximum gas temperature is around 90$0^{\circ}C$. As a result a high pressure ratio gas turbine with compression intercooling is used. This is to offset the effects of the relatively low temperature at the turbine inlet.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

The Pathologic study on 『Wenbingtiaobian』 (『온병조변』의 병리학적 고찰)

  • Park, Mi Sun;Kim, Yeong Mok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.8-19
    • /
    • 2017
  • This study on "Wenbingtiaobian" covers identifying pattern of prescription, understanding system of multiple syndrome differentiations, characteristics of treatment and medicinal substances. The source books are "Korean translation of Wenbingtiaobian", "Modern Shanghanlun", "Jinkuiyaolueyishi", "Chinese Medicine Formulas". "Wenbingtiaobian" has system of multiple patterns including three energizer syndrome differentiation, classification of disease, six meridian syndrome differentiation and wei-qi-ying-xue syndrome differentiation. That describes cause, location, nature, power and transmutation of disease. Wei-qi-ying-xue pattern is meaningful to warm-heat disease and three energizer pattern is relevant to dampness-heat disease. The warm disease shows mostly yang brightness bowel syndrome and patterns of three yin viscera. In aspect of the heat disease, qi aspect pattern makes up the largest number of syndrome differentiation and have sometimes with bowel excess or fluid deficiency. And treatment for wei aspect pattern is primarily 'outthrust the pathogen with pungent-cool'. Deficiency cold pattern and cold pattern with dampness occupy most of cold patterns. And many dampness patterns are dampness-heat pattern in middle energizer and 'inhibited lung qi transforming' is major mechanism. Patterns with fluid deficiency in qi aspect syndrome appear mostly in upper or middle energizer and in xue aspect syndrome appear mostly in lower energizer and they form 20% of all syndrome differentiations. The treatment of clearing heat uses pungent-cool(cold) for upper energizer, sweet-cold for middle energizer, sweet(salty)-cold for lower energizer. The treatment of tonifying yin uses mostly salty-cold for middle or lower energizer. The treatment of outthrusting pathogen is applied to all the wei-qi-ying-xue aspect combined with other treatments by using pungent-cool(cold) and light herbs. Understanding diseases in the respect of syndrome differentiation can enhance understanding of modern diseases from a perspective of Korean Traditional Medicinal(KTM) and can make clinical application of KTM treatments easy. Data from this study are expected to be basic for standardization and systemization of KTM.

Study on Flame Oscillations in Laminar Lift-off Butane Flames Diluted with Nitrogen (질소 희석된 부탄 부상화염에 있어서 화염진동에 관한 연구)

  • Yoon, Sung-Hwan;Park, Jeong;Kwon, Oh-Boong;Kim, Jeong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.729-738
    • /
    • 2010
  • The characteristics of lifted butane flames diluted with nitrogen have been investigated experimentally in order to elucidate the mechanism of individual flame oscillation modes. Flame oscillations in laminar free-jet lift-off flames are classified into the following five regimes: a stabilized lift-off regime (I), a heat-loss-induced oscillation (II), a buoyancy-induced oscillation along with a heat-loss-induced oscillation (III), a combined form of an oscillation prior to blow-out and a heat-loss-induced oscillation (IV), and a combination of an oscillation prior to blow-out and a buoyancy-induced oscillation along with a heat-loss-induced oscillation (V). The characterization of the individual flame oscillations modes are presented and discussed using Strouhal numbers and their relevant parameters by the analysis of the power spectrum for temporal variation of the lift-off height.

Fatigue Life Analysis of SA508 Gr. 1A Low-Alloy Steel under the Operating Conditions of Nuclear Power Plant (원자력발전소 운전환경에서 SA508 Gr. 1A 저합금강의 피로 수명 분석)

  • Lee, Yong Sung;Kim, Tae Soon;Lee, Jae Gon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Fatigue has been known as a major degradation mechanism of ASME class 1 components in nuclear power plants. Fatigue damage could be accelerated by combined interaction of several loads and environmental factors. However, the environmental effect is not explicitly addressed in the ASME S-N curve which is based on air at room temperature. Therefore many studies have been performed to understand the environmental effects on fatigue behavior of materials used in nuclear power plants. As a part of efforts, we performed low cycle fatigue tests under various environmental conditions and analyzed the environmental effects on the fatigue life of SA508 Gr. 1a low alloy steel by comparing with higuchi's model. Test results show that the fatigue life depends on water temperature, dissolved oxygen and strain rate. But strain rate over 0.4%/s has little effect on the fatigue life. To find the cause of different fatigue life with ANL's and higuchi's model, another test performed with different heat numbered and heat treated materials of SA508 Gr. 1a. On a metallurgical point of view, the material with bainite microstructure shows much longer fatigue life than that with ferrite/pearlite microstructure. And the characteristics of crack propagation as different microstructure seem to be the main cause of different fatigue life.

  • PDF

A Comparative Study of the Cold Power Generation Systems for LNG Terminal (LNG 인수기지용 냉열발전 시스템 비교 연구)

  • 김동수;박영무
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.34-41
    • /
    • 1996
  • The heat of evaporation (cold energy) of LNG is the energy consumed in the production of LNG. This energy amounts to 14% of the NG. In Pyungtak LNG terminal, it is about 96 MW in 1993. In order to utilize the cold energy, the cold power generation systems are investigated: The Rankine cycle using the low temperature energy, the partial expansion cycle using the pressure energy, and the Linde process which is a combined cycle of the Rankine and the partial direct expansion cycle. The commercial simulator, ASPEN Plus, is used. The conceptual design data are obtained from the current facilities of the Pyungtak LNG terminal. The performances of three systems are evaluated. The amount of electric power ranges iron 3 MW to 6MW. The optimum energy efficiency is about 37%. The optimum design conditions are obtained for the partial direct expansion (PDE) cycle. The performance of the PDE cycle is supposed to be comparable to that of the Rankine cycle if the areas of the total heat exchanger of the both cycle are equal.

  • PDF

Fabrication of Microwave Applicator for Hyperthermia and Thermal Distribution in Tissues (종양의 온열치료를 위한 마이크로잔 조사장치의 제작과 응용)

  • Chu S. S.;Lee J. T.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.11-20
    • /
    • 1984
  • The renewed interest in the use of hyperthermia in cancer therapy is bases on radiobiological and clinical evidence indicated that there may be a significant therapeutic advantage with the use of heat alone or combined with radiation or chemotherapy, There are many methods for generating heat for localized tumor as like radiofrequency, microwave, electromagnetic induction and ultrasound. But it is very difficult to be even thermal dose distribution and stable output of power and then the detection of temperature in tumor is difficult to be precise with thermocouples and semiconductor sensors. We designed the microwave heating generator, dipole antenna applicators and autometic temperature controlled thermocouples for localized hyperthermia on skin and in cavities. 1. The microwave generator with 120 W, 2,450MHz magnetron could be heating up to $40^{\circ}C\~50^{\circ}C\;for\;1\~2$ hours in living tissues. 2. The thermal dose distribution in tissue with microwave was described $42^{\circ}C\~44^{\circ}C$ with in 3 cm depth and $2\~6cm$ diameter area. 3. Skin surface heating applicator with spiral 3 times wave length antenna radiated high Power of microwave. 4, Intracavitary heating applicator with dipole antenna with autometic control temperature sensor kept up continuously constant temperature in tissue. 5. For constant thermal distribution, applied two steps power with 10W microwave after $17\~20W$ during first 10 minutes. 6. The cooling rate by blood flew in living tissue was rised as $10\%$ then meats.

  • PDF

Thermodynamic Analysis on the Feasibility of Turbo Expander Power Generation Using Natural Gas Waste Pressure (천연가스 폐압발전 활성화의 당위성에 대한 열역학적 분석)

  • Ha, Jong Man;Hong, Seongho;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.136-142
    • /
    • 2012
  • Thermodynamic equations for the electric power and temperature in a turbo expander generator (TEG) using pressure energy in a natural gas line are derived. From the equations, it was shown that dominant factor is not the pressure difference but the pressure ratio. The high energy level in the inlet of TEG can be made from nearly no expense of electric energy input, which means TEG can be treated as one of newly available clean energy source. If a post heating method is chosen to heat up expanded natural gas, the usage of cold energy is possible without a refrigeration cycle. The combined TEG and refrigeration system enhances economic benefit much more.

Scenario Analysis of Low-Carbon Generation Mix Considering Social Costs (사회적 비용을 고려한 저탄소 전원구성의 시나리오 분석)

  • Park, Jong-Bae;Cho, Young-Tak;Roh, Jae Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.173-178
    • /
    • 2018
  • This study organizes scenarios on the power supply and demand plans considering the uncertainties and the portion of distributed energy resources. In analysing the scenarios, it estimates total electricity supply cost in the social aspect, natural gas demand and air pollutants emission including carbon dioxide. Also the analysis is performed to estimate the marginal cost of carbon dioxide reduction for the fuel switching from coal to liquified natural gas. In result, the social cost could be decreased by replacing some portion of renewable energy by LNG-based combined heat and power and delaying the construction of large base-load generators such as coal and nuclear plants. The marginal carbon dioxide reduction cost by fuel switching is in plausible range for fuel switching to be an option for carbon dioxide emission reduction when the social cost is considered.

Developement for Pretreatment System of Distributed Power Generation by using Livestock BIO-ENERGY (축산폐기물 바이오 에너지 분산발전용 전처리시스템 개발)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin;Rhim, Sang-Gyu;Kim, Jae-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.585-588
    • /
    • 2007
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection constrains. KEPCO (Korea Electric Power Corporation) is performing the project to develope the Distributed Micro Gas Turbine (MGT) technolgies by using Swine BIO-ENERGY. This paper describes the plans and strategies for the renewable energy of MGT on actual grid-connection under Korean situations. KEPCO also, has a research plan on bio-gas pretreatment system applicable to our domestic swine renewable resources and is performing concept design of pilot plant to test grid operation. In addition, this testing will be conducted in order to respond to a wide variety of needs for application and economic evaluation in the field of On-site generation.

  • PDF