Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang (Department of Nuclear Engineering and Technology, School of Energy and Power Engineering, Huazhong University of Science and Technology) ;
  • Zhou, Xiafeng (Department of Nuclear Engineering and Technology, School of Energy and Power Engineering, Huazhong University of Science and Technology) ;
  • Yang, Jun (Department of Nuclear Engineering and Technology, School of Energy and Power Engineering, Huazhong University of Science and Technology)
  • Received : 2019.05.15
  • Accepted : 2019.12.13
  • Published : 2020.07.25

Abstract

Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

Keywords

References

  1. J. Yang, D.Y. Lee, S. Miwa, S.-w. Chen, Overview of filtered containment venting system in nuclear power plants in Asia, Ann. Nucl. Energy 119 (2018) 87-97. https://doi.org/10.1016/j.anucene.2018.03.047
  2. D. Jacquemain, S. Guentay, S. Basu, M. Sonnenkalb, L. Lebel, H.J. Allelein, B.L. Martinez, B. Eckardt, L. Ammirabile, OECD/NEA/CSNI status report on filtered containment venting, in: Organisation for Economic Co-operation and Development, 2014.
  3. P. Dejardin, T. Helman, J. Bulle, J. Dienstbier, L. Oury, L. Sallus, Methodology developed for the definition of the design parameters and associated safety criteria of the Filtered Containment Venting Systems for Belgian NPPs, Ann. Nucl. Energy 93 (2016) 58-64. https://doi.org/10.1016/j.anucene.2015.12.024
  4. C.H. Kim, H.C. NO, M.H. Chun, Application of RELAP5/MOD3.2 to the Prediction of Two-phase Mixture Level Swell and Liquid Entrainment from the Two-phase Mixture Surface during Depressurization in a Vessel, PHYSOR, 2002.
  5. I.Inc, in: Martland Rockville (Ed.), RELAP5/MOD3.3 Code Manual Volume IV: Models and Correlations, 2001.
  6. J. Yang, D. Suckow, T. Lind, H.-M. Prasser, Study of level swell for a filtered containment venting system at the VEFITA facility, Prog. Nucl. Energy 113 (2019) 7-17. https://doi.org/10.1016/j.pnucene.2019.01.003
  7. H. Rust, C. Tfinnler, W. Heintz, D. Haschke, M. Nuala, R. Jakab, Pressure release of containments during severe accidents in Switzerland, Nucl. Eng. Des. 157 (1995) 337-352. https://doi.org/10.1016/0029-5493(95)01015-A
  8. Y.M. Song, H.S. Jeong, S.Y. Park, D.H. Kim, J.H. Song, Overview of containment filtered vent under severe accident conditons at wolsong NPP unit 1, Nucl. Eng. Technol. 45 (2013) 597-604. https://doi.org/10.5516/NET.03.2013.712
  9. N.R. Lee, Y.S. Bang, D.Y. Lee, H.T. Kim, Analysis of containment venting strategy under severe accident conditions, Ann. Nucl. Energy 94 (2016) 633-642. https://doi.org/10.1016/j.anucene.2016.04.010
  10. L.S. Lebel, A.C. Morreale, V. Korolevych, M.J. Brown, S. Gyepi-Garbrah, Severe accident consequence mitigation by filtered containment venting at Canadian nuclear power plants, Ann. Nucl. Energy 102 (2017) 297-308. https://doi.org/10.1016/j.anucene.2016.08.005
  11. S. Widodo, J. Ishikawa, K. Muramatsu, T. Sakamoto, Analysis of Containment Venting Following a Core Damage at a BWR Mark I Using THALES-2, JAERI-Conf, 2000.
  12. K. Yuan, W.Q. Qie, L.L. Tong, X.W. Cao, Analysis on containment depressurization under severe accidents for a Chinese 1000 MWe NPP, Prog. Nucl. Energy 65 (2013) 8-14. https://doi.org/10.1016/j.pnucene.2013.01.006
  13. S.-W. Lee, T.-H. Hong, Y.-J. Choi, M.-R. Seo, H.-T. Kim, Containment depressurization capabilities of filtered venting system in 1000 MWe PWR with large dry containment, Sci. Technol. Nucl. Install. (2014) 1-10, 2014.
  14. L. Ji-ming, C. Peng, Z. Shi-shun, Study of containment over-pressure fragility curve and analysis of opening pressure for containment filtration and exhaust system, Nucl. Power Eng. 32 (2011) 10-14.
  15. T. Lind, D. Suckow, J. Yang, Characterization of the performance of wet scrubers used in FCVS, in: Proceedings of a Technical Meeting on Severe Accident Mitigation through Improvements in Filtered Containment Venting for Water Cooled Reactors, 2015, 31 August-3 September 2015, Vienna, Austria.
  16. G. Huang, L. Fang, Feasibility research of containment venting for CANDU6, Nucl. Eng. Des. 268 (2014) 113-120. https://doi.org/10.1016/j.nucengdes.2013.11.082
  17. Y.S. Na, K.S. Ha, R.-J. Park, J.-H. Park, S.-W. Cho, Thermal hydraulic issues of containment filtered venting system for a long operating time, Nucl. Eng. Technol. 46 (2014) 797-802. https://doi.org/10.5516/NET.02.2014.031
  18. S. Schwarz, M. Sonnenkalb, Lessons learned from analytical re-evaluation of a venturi scrubber venting systems implemented in German NPPs through COCOSYS analyses, in: Proceedings of a Technical Meeting on Severe Accident Mitigation through Improvements in Filtered Containment Venting for Water Cooled Reactors, vol. 31, 2015. August-3 September 2015, VIENNA,AUSTRIA.
  19. A. Ui, M. Furuya, T. Kanai, Accident progression analyses of a BWR with filtered containment venting system during long term severe accident conditions, in: Proceedings of ICAPP, FUKUI and KYOTO,JAPAN, 2017.