• 제목/요약/키워드: Column Experiment

Search Result 722, Processing Time 0.025 seconds

Laboratory Tests of Chromium-51 Complexes for teak Detection in Pipes Carrying A Liquid Flow

  • Kim, You-Sun;Lee, Byung-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.231-237
    • /
    • 1974
  • For detection and localization of leaks in closed vessels or pipes carrying liquid flow, $^{51}$ Cr-EDTA and $^{51}$ Cr-DTPA were synthesized and, the column and batch equilibrium experiments were carried out. In the column experiment, the recovery of $^{51}$ Cr-EDTA is 100% in quartz sand and 80.9% in steel sawdust, and that of $^{51}$ Cr-DTPA is 77.4% in quartz sand and 6.4% in steel sawdust. The recovery curve. $^{51}$ Cr-DTPA system in steel sawdust does not show a certain plateau, exceptionally. In general, $^{51}$ Cr-EDTA is adsorbed less than $^{51}$ Cr-DTPA. In the batch equilibrium experiment, the distribution coefficients (Kd) and effect of pH were investigated by using quartz sand, montmorillonite, steel sawdust, and mixed cement raw material as media. In general, the Kd values for $^{51}$ Cr-EDTA are lower than that of $^{51}$ Cr-DTPA. The Kd values for $^{51}$ Cr-EDTA are almost zero at pH 6.0, 7.0, and 8.0.

  • PDF

Simultaneous Removal of Cd &Cr(VI) by Fe-loaded zeolite in Column System (컬럼실험을 통한 Fe-loaded zeolite의 Cd& Cr(VI) 동시제거 반응성 평가)

  • Lee A-Ra;Lee Seung-Hak;Park Jun-Beom
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.151-154
    • /
    • 2005
  • Laboratory column experiments for simultaneous removal of Cd and Cr(VI) are conducted using newly developed material, referred to as Fe-loaded zeolite, which has both reduction ability of iron and ion exchange ability of zeolite. Breakthrough curves were obtained from each column experiment, and described with advection-dispersion equation. Apparent parameters including $K_{app}\;and\;D_{app}$ were newly introduced for effectively describing the Cr(VI) breakthrough curve. $K_{app}$ decreased with increasing initial contaminant concentration and with decreasing flow rates. Whereas, $D_{app}$ were not significantly affected by initial contaminant concentration or flow rate.

  • PDF

Visualization of bulging development of geosynthetic-encased stone column

  • Zhou, Yang;Kong, Gangqiang;Peng, Huaifeng;Li, Chunhong;Qin, Hongyu
    • Geomechanics and Engineering
    • /
    • v.18 no.3
    • /
    • pp.329-337
    • /
    • 2019
  • This paper presents an experimental investigation about visualization of bulging development of geosynthetic-encased stone column (GESC) based on the digital image correlation (DIC) technique and transparent soil. Visual model tests on GESC and ordinary stone column (OSC) were carried out. In order to delete the warping effect resulting from transparent soil and experiment setup, a modification for experiment results was performed. The bulging development process of the GESC and the displacement field of the surrounding soil were measured. By comparing with the existing experimental and theoretical results, it demonstrates that the model test system developed for studying the continuous bulging development of GESC is suitable. The current test results show that the bulging depth of GESC ranges from 1.05 to 1.40 times the diameter of GESC. The influence depth of GESC bulging on surrounding soil displacement is 0~3 the times diameter of GESC.

An Experimental Study on TR-CFT Columns subjected to Axial Force and Cyclic Lateral Loads (축력과 반복수평력을 받는 TR-CFT기둥에 관한 실험적 연구)

  • Park, Jai Woo;Kim, Jin Ho;Hong, Young Kyun;Hong, Gi Soup
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.403-411
    • /
    • 2007
  • CFT (Concrete filled steel tube) column has become popular for building construction due to not only its composite effect but also economic effect. However, the conventional CFT column also has its own disadvantages having plastic buckling at the end of column followed by the reduction of strength by yielding of steel tube. An experiment on TR-CFT (Transversely reinforced CFT) column are conducted for making up for conventional CFT column's disadvantages. The experiment parameters are strength of concrete, the layer numbers of carbon fiber sheet. In this study, hysteretic curve, initial stiffness, strength, plastic deformation capacity, and dissipated energy are compared and analyzed between CFT and TR-CFT columns.

Virbration Characteristics of a passenger Car Steering Column

  • Lee, Young-Shin;Song, Sun-Young;Park, Myoung-Hwan;Ryu, Chung-Hyun;Kim, Young-Wann
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.130-141
    • /
    • 2000
  • The virbration characteristics of a passenger car steering column are studied by using a modal test and a finite element (FE) analysis. To verify the FE model and the results, an experiment using the impact exciting method is performed. Two types of the steering column in this study are considered as follows; (ⅰ) the non-tilt type steering column and (ⅱ) the upper-tilt type steering column. The experimental results are compared with those o the FE analysis, and it ti shown that the results agree with each other. The effects of various design parameters such as the bracket thickness, the column diameter on the natural frequencies are also investigated by FE analysis.

  • PDF

A Study on Void Examination in Top-Down Column Joint (역타설기둥 타설이음 부분의 공극성상에 관한 연구)

  • 이영도;임형일;김성식;정병훈;정상진;진영헌
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.34-39
    • /
    • 2001
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is finding a way to prevent concrete void and concrete suitable for top down, through V-metering for top down column and concrete experiment.

  • PDF

The Analytical Study on the Structural Performance of Beam-Column Connections of RC Column and Steel Beam (철근 콘크리트 기둥과 철골 보 접합부의 거동 평가틀 위한 해석적 연구)

  • Hong, Seong-Heon;Han, Sang-Whan;Ryu, Cheon;Lee, Li-Hyung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.110-116
    • /
    • 1998
  • The three-dimensional nonlinear analysis on the partial tension experiment of Beam-Column connections in hybrid connections with RC columns and S beams is simulated. In this paper, mechanical characteristics between steel plates and concrete is investigated. Also the stress transfer mechanism prior to beam-column connection analysis was considered by using joint element.

  • PDF

Parametric Study on Oscillating Water Column Wave Energy Converter Applicable to Breakwater

  • Park, Sewan;Nam, Bo Woo;Kim, Kyong-Hwan;Hong, Keyyong
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.2
    • /
    • pp.66-77
    • /
    • 2018
  • This paper presents a parametric study on an oscillating water column (OWC) wave energy converter (WEC). This OWC has been planned for installation in the breakwaters on isolated islands located away from the mainland. Both a numerical analysis and a model experiment are utilized for determining a proper conceptual design for this purpose. Various design parameters, including the configurations and dimensions, are evaluated through the numerical analysis, which is based on a potential flow theory, and several design concepts are then selected as candidates. The model experiment using a 2D wave flume is conducted to evaluate the effects of the design parameters and compare the performances of the candidates. Based on the overall results of the numerical analysis and model experiment, a conceptual design of the OWC WEC applicable to a breakwater is selected.

Soil Column Experiment to Evaluate Removal of Nutrients in Stormwater Runoff by Soil of Riparian Protection Zone (토양칼럼을 이용한 초기우수 중 염양염류의 수변녹지 토양에서의 제거도 평가)

  • Yoon, Seok-Pyo;Choi, Ji-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.231-235
    • /
    • 2004
  • To investigate removal effects of nutrients in stormwater runoff by soil of riparian protection zone, soil column experiment was conducted for 20 months. Artificial stormwater runoff containing phosphate and nitrate was applied on the surface of soil column twice a week, and phosphate and nitrate concentrations were measured from the leached water. Soil of riparian protection zone reduced the released amount of infiltrated water to the surrounding water. After infiltration of 1m depth of soil column, average removal rates of phosphate and nitrate were 97.7 % and 74.7 %, respectively. As main mechanisms of phosphate are adsorption to soil particle and utilization by plants, periodical replacement of soil and harvesting of plant at the end of growing season are required. For the removal of nutrients in stormwater runoff by the soil layer, soil of riparian protection zone has higher hydraulic conductivity to infiltrate stormwater. Sandy soil having hydraulic conductivity of about $1{\times}10^{-2}cm/s$ range might be appropriate for this purpose.

The Experimental Study on Deflation of Air for Top-Down Joint area (역타기둥 이음부의 공기포 배출을 위한 실험적 연구)

  • 임형일;이동하;백민수;박병근;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.763-768
    • /
    • 2001
  • The purpose of this study is to research a specific material characteristics of top down concrete at column joint and to reduce column joint opening. Based on the established top down study, the experiment to apply an real construction case is performed. When the concrete placed into joint of top down column, raised air bubble is left as opening. This study is examined the incomplete packing reason in the top down column and found to air deflation method. The result of study is below (1) As the method to minimize column opening caused from confined air, it is required that an air exhaust port installation in joint column. (2) From air exhaust port installation, most of air bubble in column part is exhausted. As the concrete placing height is going up, air bubble size is going smaller.

  • PDF