• Title/Summary/Keyword: Color and fluorescence

Search Result 169, Processing Time 0.024 seconds

DEVELOPMENT OF CHLOROPHYLL ALGORITHM FOR GEOSTATIONARY OCEAN COLOR IMAGER (GOCI)

  • Min, Jee-Eun;Moon, Jeong-Eon;Shanmugam, Palanisamy;Ryu, Joo-Hyung;Ahn, Yu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.162-165
    • /
    • 2007
  • Chlorophyll concentration is an important factor for physical oceanography as well as biological oceanography. For these necessity many oceanographic researchers have been investigated it for a long time. But investigation using vessel is very inefficient, on the other hands, ocean color remote sensing is a powerful means to get fine-scale (spatial and temporal scale) measurements of chlorophyll concentration. Geostationary Ocean Color Imager (GOCI), for ocean color sensor, loaded on COMS (Communication, Ocean and Meteorological Satellite), will be launched on late 2008 in Korea. According to the necessity of algorithm for GOCI, we developed chlorophyll algorithm for GOCI in this study. There are two types of chlorophyll algorithms. One is an empirical algorithm using band ratio, and the other one is a fluorescence-based algorithms. To develop GOCI chlorophyll algorithm empirically we used bands centered at 412 nm, 443 nm and 555 nm for the DOM absorption, chlorophyll maximum absorption and for absorption of suspended solid material respectively. For the fluorescence-based algorithm we analyzed in-situ remote sensing reflectance $(R_{rs})$ data using baseline method. Fluorescence Line Height $({\Delta}Flu)$ calculated from $R_{rs}$ at bands centered on 681 nm and 688 nm, and ${\Delta}Flu_{(area)}$ are used for development of algorithm. As a result ${\Delta}Flu_{(area)}$ method leads the best fitting for squared correlation coefficient $(R^2)$.

  • PDF

Symmetric Bis-Azospiropyrans: Synthesis, Characterization and Colorimetric Study

  • Nourmohammadian, Farahnaz;Abdi, Ali Ashtiani
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1727-1734
    • /
    • 2013
  • Synthesis and characterization of some novel symmetric bis-azospiropyrans are reported in this study. These bis-azospiropyrans are bifunctional chromophores with two spiropyrans linked by a bis-azo extended aromatic system that produce more color strength (large molar absorption coefficient in mero forms) due to appending two azospiropyran chromophores on one molecule. Comparing to the molar absorption coefficients of the conventional spiropyran chromophores (${\varepsilon}=0.31{\times}10^4\;M^{-1}{\cdot}cm^{-1}$) and mono-azospiropyran chromophores ($1.35{\times}10^4\;M^{-1}{\cdot}cm^{-1}$), the novel synthesized photochromes showed astonishingly increased molar absorption coefficients ($2.3-3.8{\times}10^4\;M^{-1}{\cdot}cm^{-1}$) at the same conditions. Such high molar absorption coefficients confers high sensitivity to light and more color intensity of mero form, that leads to improvement of their light sensitivity and better discrimination of spiro (OFF) form from mero (ON) ones in molecular switches. The structures were deduced from their MS, FT-IR, and $^1H$-NMR spectroscopic data and CHN analysis. All the synthesized photochemically bifunctional compounds revealed fluorescent emission in their colorless form which was faded out after exposing to UV light. Fluorescence quantum yield values of the mero forms were 0.25-0.81 and two high fluorescence quantum yield values (0.60 and 0.81) were found in these series.

Chromosome Rearrangements Detected by Fluorescence in situ Hybridization in Human Lymphocyte Exposed to Bleomycin (Fluorescence in situ hybridization (FISH)를 이용하여 분석한 Bleomycin에 의한 사람 림프구의 염색체 재배열)

  • 손은희;정경인;정해원
    • Environmental Mutagens and Carcinogens
    • /
    • v.17 no.1
    • /
    • pp.12-16
    • /
    • 1997
  • Chromosome rearrangement induced by bleomycin were identified by fluorescence in situ hybridization with probe for chromosome 4. The frequency of color junctions, translocations, dicentric and acenttic fragments increased with bleomycin dose. Different types of balanced translocation and dicentric were scored and compared. The frequency of cells exhibiting multiple aberration was higher compared to that of cells exposed to Gamma radiation suggesting that effect of bleomycin might be similar to that of high LET radiation.

  • PDF

Spectroscopic Characteristics of Gemstones with Color Change Effect (변색 효과 보석들의 분광학적 특성)

  • Ahn, Yong-Kil;Seo, Jin-Gyo;Park, Jong-Wan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.81-86
    • /
    • 2009
  • The luminescence and fluorescence were investigated by photoluminescence spectroscopy for six gemstones which exhibit color change effect. The shape of luminescence peaks appears different when observed by a photoluminescence spectroscopewith a 514 nm Ar laser source. However, it was not possible to observe the difference in the spectra between the natural and synthetic origins for the same type of gemstones. It was found that the photoluminescence spectrum was related to the crystal structure of the stones. Photoluminescence spectra using a 325 nm He-Cd source reveal that fluorescence is relatively strong for synthetic alexandrite, synthetic color change sapphire and natural alexandrite comparing to the rest of gemstones examined.

Understanding of the color in composite resin (복합레진의 색에 대한 이해)

  • Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.271-279
    • /
    • 2011
  • In clinic, esthetic restoration of a defective natural tooth with composite resin is challenging procedure and needs complete understanding of the color of tooth itself and materials used. The optical characteristics of the composites are different because the chemical compositions and microstructures are not same. This review provided basic knowledge of the color and the color measurement devices, and analyze the color of the natural tooth. Further, the accuracy of the shade tab, color of the composite resins before and after curing, effect of the water, food and bleaching agent, and translucency, opalescence, and fluorescence effects were evaluated.

In Vivo Quantitative Analysis of PKA Subunit Interaction and cAMP Level by Dual Color Fluorescence Cross Correlation Spectroscopy

  • Park, Hyungju;Pack, Changi;Kinjo, Masataka;Kaang, Bong-Kiun
    • Molecules and Cells
    • /
    • v.26 no.1
    • /
    • pp.87-92
    • /
    • 2008
  • We employed dual color Fluorescence Cross Correlation Spectroscopy (FCCS) to measure the interaction between PKA regulatory (RII) and catalytic subunits (CAT) in living cells. Elevation of intracellular cAMP with forskolin decreased the cross-correlation amplitude between RFP-fused RII (RII -mRFP) and GFP-fused CAT (CAT-EGFP) by 50%, indicating that cAMP elevation leads to dissociation of RII-CAT complexes. Moreover, diffusion coefficient analysis showed that the diffusion rate of CAT-EGFP was significantly increased, suggesting that the decreased RII-CAT association caused by cAMP generated free CAT subunits. Our study demonstrates that in vivo FCCS measurements and their quantitative analysis permit one not only to directly quantify protein-protein interactions but also to estimate changes in the intracellular cAMP concentration.

UV/blue Light-induced Fluorescence for Assessing Apple Quality (자외선 유도 형광의 사과 성숙도 평가 적용)

  • Noh, Hyun-Kwon;Lu, Renfu
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.124-131
    • /
    • 2010
  • Chlorophyll fluorescence has been researched for assessing fruit post-harvest quality and condition. The objective of this preliminary research was to investigate the potential of fluorescence spectroscopy for measuring apple fruit quality. Ultraviolet (UV) and blue light was used as an excitation source for inducing fluorescence in apples. Fluorescence spectra were measured from 'Golden Delicious' (GD) and 'Red Delicious' (RD) apples using a visible/near-infrared spectrometer after one, three, and five minutes of continuous UV/blue light illumination. Standard destructive tests were performed to measure fruit firmness, skin and flesh color, soluble solids and acid content from the apples. Calibration models for each of the three illumination time periods were developed to predict fruit quality indexes. The results showed that fluorescence emission decreased steadily during the first three minutes of UV/blue light illumination and was stable within five minutes. The differences were minimal in the model prediction results based on fluorescence data at one, three or five minutes of illumination. Overall, better predictions were obtained for apple skin chroma and hue and flesh hue with values for the correlation coefficient of validation between 0.80 and 0.90 for both GD and RD. Relatively poor predictions were obtained for fruit firmness, soluble solids content, titrational acid, and flesh chroma. This research has demonstrated that fluorescence spectroscopy is potentially useful for assessing selected quality attributes of apple fruit and further research is needed to improve fluorescence measurements so that better predictions of fruit quality can be achieved.

A Study on the Molybdenum in Scheelite of Sangdong tungsten ore bodies (상동(上東) 광상(鑛床) 몰리브덴의 산출(産出) 상태(狀態)에 대(對)한 연구(硏究))

  • Moon, Kun Joo;Lee, Hang Jai
    • Economic and Environmental Geology
    • /
    • v.13 no.2
    • /
    • pp.117-127
    • /
    • 1980
  • Molybdenum as by-products of Sangdong tungsten mine occurrs in the form of molybdenite in quartz vein. The molybdenum contents of scheelite in Sangdong ore bodies ranges from trace to 8%, therefore the scheelites show variable fluorescence colores under ultra-violet lamp (short wave). The fluorescence color are in order high content of molybdenum, yellow, white and blue. The yellow fluorescing scheelite is dominant in upper ore vein, otherwise the blue fluorescent variety is dominant in lower ore vein. The fluorescence color of scheelite in the main ore vein show zonal distribution becoming progressively more blue outerwards, contrary more yellow innerwards, and even in single scheelite crystal, simillar zonal pattern is observed, too. Molybdenite occurrs as flakes or elongated blades at the margins of the quartz vein only molybdenite bearing quartz veins but also other sulfides mineral bearing quartz veins have mainly blue flourescing scheelites. We suggest that the molybdenum contents of the early stage ore solution are progressively decreased by a subsequent crystallization of the yellow fluorescing scheelites.

  • PDF

Analysis for Concentration Range of Fluorescein Sodium (플루오레신나트륨의 농도 범위 분석)

  • Lee, Da-Ae;Kim, Yong-Jae;Yoon, Ki-Cheol;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

Photoionization of N,N,N',N'-Tetramethyl-p-phenylenediamine in Polar Solvents

  • Min Yeong Lee;Du Jeon Jang;Minyung Lee;Du-Jeon Jang;Dongho Kim;Sun Sook Lee;Bong Hyun Boo
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.4
    • /
    • pp.429-433
    • /
    • 1991
  • The photoinduced electron transfer reactions of N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD) in various polar solvents were studied by measuring time-resolved fluorescence. The temperature dependence on the fluorescence decay rate in acetonitrile, methanol, ethanol and buthanol was carried out to obtain the activation energy and Arrehnius factor for the photoinduced electron transfer reaction. It was found that as the dielectric constant of the solvent increases, the activation energy and the reaction rate increase. This implys that the Arrehnius factor is important in controlling the photoinduced electron transfer reaction rate. In water, TMPD exists in three forms (cationic, protonated and neutral forms) due to the high dielectric constant and strong proton donating power of water. The photoinduced electron transfer reaction was found to be very fast (< 50 ps) and also the long liverd component in the fluorescence decay profile attributable to the photoexcited protonated form of TMPD was observed. Probably, the reaction pathway and the reaction coordinate seem to be different depending on the solvents studied here.