• Title/Summary/Keyword: Color analyzer

Search Result 156, Processing Time 0.024 seconds

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

A Study on Urine Analyzer Using Color Images of Strip (스트립의 컬러영상을 이용한 요 분석기에 관한 연구)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.7
    • /
    • pp.919-923
    • /
    • 2007
  • This paper presents an urine analyzer using color images of strip. An image sensor has been used to acquire an color images. The analyzer has a characteristics which takes a pictures of independent each pad responding to urine items all at once, and outputs the measured urine values by analysing an acquired pad colors. This device measures and analyses 11 urine items, and has a speed-up operation, light weight, small size, and makes accurate observations by processing the measured colors using processor. The urine analyzer transmits the urine items to peripheral devices, personal computers, hospitals, and another places by using a telegraph and a wireless interfaces.

Non-imaging Optical Design of a Measurement Probe for LCD Display Used in a Color Analyzer (LCD 디스플레이용 색채계 렌즈에 관한 비결상 광학설계)

  • Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.5
    • /
    • pp.239-244
    • /
    • 2011
  • We introduce Gaussian (or paraxial) optics that can be successfully applied to design, for use in a color analyzer, a non-imaging optical system on a measurement probe for LCD display. The color analyzer is used to decompose colored lights leaving from some measurement area on the LCD display to red, green, and blue. The color analyzer must include a condenser lens whose purpose is to gather colored lights to illuminate a small area on the sensor. In order to satisfy a reduction ratio between the measurement area and the sensing area with a non-imaging condition, a condenser lens is analytically treated by means of Gaussian optics so that good understanding of the non-imaging condenser lens is achieved as a good design is derived. As a result, the technique shows the necessity of analytical treatment in contrast to the design approach using only commercial software such as CODE-V, Light-Tools, and others. Of course, CODE V and Light-Tools are also utilized in this paper to confirm and complete the Gaussian optical design.

Development of Primary Color Reaction System of Urine Analyzer for U-health (유헬스용 요분석기의 정색반응 시스템 개발)

  • Lee, Sang-sik;Park, Won-yeop;Goo, Ji-hyun;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • This study was conducted to develop a electronic circuit of primary color reaction for urine analyzer for measuring color response of urine strip. A primary color reaction system is equipped with the computer, electronic circuit, tray, detecting assembly and software. The determination of coefficient($R^2$) between reagent and color sensor were 0.9801(R), 0.9868(G) and 0.9837(B). To evaluate the system verification, we measured the primary color reaction of erythrocytes, Bilirubin, Urobilinogen, Ketones and Protein. We concluded that it is possible to use the developed the primary color reaction system for urine analyzer using u-health.

  • PDF

Effect of elevated temperatures on properties and color intensities of fly ash mortar

  • Wang, Her-Yung
    • Computers and Concrete
    • /
    • v.5 no.2
    • /
    • pp.89-100
    • /
    • 2008
  • This research examines the engineering properties and color intensities of mortar containing different amounts of fly ash (0, 5, 10 and 20%) mixed at different water-to-binder ratios (w/b = 0.23, 0.47 and 0.59) and exposed at different temperatures (T = 25, 100, 200, 400, 600 and $800^{\circ}C$). Results show that there is greater mass loss on ignition with high w/b and higher temperatures. In addition, the color channel image analyzer (Windows software written in Delphi) is utilized to study the relationship between the curing temperature and intensity of three primary colors, red, green and blue (RGB), of the fly ash mortar specimens. The results show that the RGB intensities on the specimen surface increases from that at $25^{\circ}C$. The mortar specimen becomes white with increase in w/b but without the addition of fly ash. Moreover, for mortar specimens with greater content of fly ash, red on the specimen surface has the greatest increase in intensity at elevated temperature. Observation the variations in color on the specimen surface may help estimate the highest elevated temperatures that concrete structures can withstand.

The Compensation of Chromaticily Coordinates on Primary Color Reaction of Urine Strips (요분석 스트립의 정색반응에 대한 색도좌표 보정)

  • 김재형;조진욱;남상희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.320-323
    • /
    • 2001
  • A computer simulation was performed to distinguish quantitatively a color reaction in a urine analysis systems by using the spectral power distribution of LEDs, the spectral reflectance of a urine strip, and the spectral sensitivity of photodiode. The CIE tristimulus values and CIE chromaticity coordinates ware modified to be conformable with real color reactions in a urine strips. Results on color simulation showed a of real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

Manufacturing of Functionalized ColorMook by Addition of the Color and Flavor from Natural Foods (천연식품의 색과 향기를 첨가한 기능성 칼라 묵의 제조)

  • Chang, Kyung-Mi
    • Journal of the Korean Society of Food Culture
    • /
    • v.22 no.3
    • /
    • pp.365-372
    • /
    • 2007
  • This study was carried out to make the new products of color moot as a functional food by variation of the color and flavor through addition of gamgyul, Daccus Carota Var. Sativa, Vitis vinifera, soy sauce, and Pimpinella brachycarpa N., respectively. For all the products, the color was observed by Colorimeter and the sensory evaluation was performed to evaluate their effectiveness and usefulness. The A$_w$ (water activity) test of color mooks has performed to examine their water activity individually. The A$_w$ of color moot was higher than that of the white one. The characters of texture of color mook as a function of the amount of the color and the flavor added were measured by a texture analyzer (XT-RA, Texturometer). By the TPA test, the rainbow and orange color mook examined were high in the springiness.

Studies on the Synthesis of Intermediate Cyan Coupler and Color Development (Cyan Coupler 중간체의 합성과 발색현상에 관한 연구)

  • Kim, Yeoung-Chan;Sohn, Byoung-Chung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.35-41
    • /
    • 1996
  • In this paper, intermediate cyan coupler was prepared by the reaction of 2-nitro-4, 6-dichloro-5-methylphenol with Pd(5wt%). The product was identified by using various analytical tools such as melting point, elemental analyzer, IR spectrophotometer and mass spectrometer. The reaction of intermediate cyan coupler with CD-3(color development agent) was shown cyan color.

Quality Characteristics of Bread Prepared with the Addition of Persimmon Peel Powder (감피 첨가 식빵의 품질 특성)

  • 김창섭;정신교
    • Food Science and Preservation
    • /
    • v.8 no.2
    • /
    • pp.175-180
    • /
    • 2001
  • The quality characteristics of bread prepared with the addition of dried persimmon peel powder(PPP) were investigated. Visco-elastic characteristics of dough and texture of bread added PPP was examined by rapid visco-analyzer and texture analyzer. The maximum viscosity of the dough with PPP was lower than that of control at 90$\^{C}$. Final viscosity after cooling to 50$\^{C}$, viscosity of control increased to 134 B.U., but that of the dough with PPP showed 13∼37 B.U. As more PPP was added, gluten formation and mixing time dough were longer. Adhesiveness, springness, cohesiveness and chewiness gradually increased as PPP content increased, while the hardness decreased. Lightness value decreased but redness and yellowness values increased with the addition of PPP, especially, the bread made by 15% PPP treatment showed dark brown color. In sensory evaluation of bread, score of color decreased significantly as more PPP was added but overall acceptability was not significant different(p<0.05) between control and 5% PPP treatment. It is considered that the addition of 5% was appropriate for bread making with PPP.

  • PDF

A Study on the Development of Urine Analyzer System (뇨분석 시스템 개발에 관한 연구)

  • Lee, S.J.;Choi, B.C.;Kim, K.N.;Hong, S.I.;Kim, J.H.;Kim, J.H.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.303-308
    • /
    • 1997
  • In this paper, we analyzed the spectroscopic properties of strip to analyzer urine qualitatively & quantitatively and make urine analyzer system stable by spectroscopy, and research the property of preamplifier unit. The analysis of spectroscopic properties of 10 pads in the strip is used for determine the wave length of light source of optic detector unit and used for basic materials which are necessary that we develop the algorithm analyzing the density grade of pad accurately. We make preamplifier unit by using the current to frequency method to measure the distribution of pad color. We implemented urine analyzer system. This system's hardware is composed of measuring unit for detect of distribution density of strip pad, main processing unit, communication unit, interface device, thermal printer, and indicator. The software consists of the program which manage the argument of test, proportion initial value of urine analyzer and calibrate analyzed result.

  • PDF