• Title/Summary/Keyword: Colony forming unit

Search Result 192, Processing Time 0.027 seconds

Investigation of Colony Forming Unit (CFU) of Microorganisms in the Paprika-grown Greenhouses Using Open and Closed Soilless Culture Systems (순환식과 비순환식 수경재배 방식에 따른 파프리카 재배온실 내 미생물의 집락형성단위(CFU) 조사)

  • Ahn, Tae In;Kim, Do Yeon;Son, Jung Eek
    • Horticultural Science & Technology
    • /
    • v.32 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • This study was conducted to compare colony forming unit (CFU) of microorganisms in closed and open soilless culture systems for estimating the possibility for potential disease occurrence. Samples were collected at four different positions in four commercial greenhouses with closed or open soilless culture system using rock wool or coir as substrate, respectively. The distance between sampling positions was 3 cm starting from the substrate and the surface area of each position was $25cm^2$. The CFU of fungi was significantly higher in the open system, while that of bacteria was not significantly different but showed relatively lower in the closed system. Samples collected at the plastic surface of the substrates where little environmental effects occurred from drainage showed lower CFU than any other positions. The principal component analysis showed that samples collected on the drainage pathway highly affected the changes in microbial population in the greenhouse. These results indicated that greenhouses with closed soilless culture are expected to have more advantageous conditions for restraining the microbial growth, resulting in the lower potential of disease occurence in greenhouse ecosystem.

Effect of Lowered and Cycled Storage Temperature of Rice Cooker (낮고 반복된 저장 온도의 밥솥에서 밥의 색 및 미생물 성장에 미치는 효과)

  • Na, Hye-Jung;Ryu, Dong-Kul;Lee, Yun-Gi;Oh, Yong-Taek;An, Gil-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.7
    • /
    • pp.958-963
    • /
    • 2009
  • To improve the quality of boiled rice after storage in rice cookers, temperature was controlled at a lowered condition ($45{\sim}65^{\circ}C$ repeated temperature cycling), compared to the present commercial rice cookers ($75^{\circ}C$). The effect of lowered temperature cycling on the microbial growth, color of rice, and reducing sugar production was measured. The bacteria Bacillus cereus and B. subtilis were killed at $75^{\circ}C$ and $45{\sim}65^{\circ}C$ cycling. The temperature cycling at $45{\sim}65^{\circ}C$ prevented an increase in colony forming unit of E. coli more than the steady temperature at $75^{\circ}C$. Browning during storage was significantly decreased at $45{\sim}65^{\circ}C$ cycling, compared to $75^{\circ}C$. The yellowness increase (${\Delta}b$ value of CIE parameters of the colorimeter) after the 3-day storage was 2.18 at $45{\sim}65^{\circ}C$ cycling whereas 9.12 at $75^{\circ}C$. Reducing sugar was not produced at $75^{\circ}C$ and $45{\sim}65^{\circ}C$ cycling but produced at $30^{\circ}C$ because of the microbial growth. In conclusion, the temperature cycling at $45{\sim}65^{\circ}C$ can improve the quality of stored boiled rice by decreasing the browning and inhibiting the microbial growth.

Investigation of Pathogenic Microorganism from Saengsik-classes (시판생식의 위해미생물 오염도 조사)

  • Cho, Joon-Il;Park, Yong-Chjun;Ko, Soo-Il;Cheung, Chi-Yeun;Lee, Sun-Mi;Cho, Soo-Yeol;Lee, Kwang-Ho;Lim, Chul-Joo;Kim, Ok-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.257-263
    • /
    • 2008
  • As Standards and Specifications of the Saengsik-classes has been established since 2005 by KFDA. The microbial Standards and Specifications of the Saengsik-classes is as follows; no detection in Escherichia coli, colony forming unit less then 1,000/g in Bacillus cereus, colony forming unit less then 100/g in Clostridium perfringens respectively. Contamination levels of Total aerobic bacteria, Escherichia coli, Bacillus cereus and Clostridium perfringens in Saengsik-classes were monitored. Total aerobic bacteria counts in Saengsik-classes was $1{\times}10^1{\sim}5.3{\times}10^7cfu/g$, for Bacillus cereus $1{\times}10^2{\sim}9{\times}10^2cfu/g$, for Clostridium perfringens $1{\times}10^1cfu/g$. Escherichia coli, was not isolated from all Saengsik-classes. Thess results will provide information for introduction of HACCP system to ensure microbial safety of Saengsik-classes.

Application of Teeth Whitening LED for Prevention of Dental Caries : Antimicrobial Photodynamic Therapy Approach (치아우식 예방을 위한 치아미백기의 활용 : 광역동 치료로서의 접근)

  • Park, Choa;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.70-77
    • /
    • 2020
  • The present study is aimed to assess the effect of antimicrobial photodynamic therapy (aPDT) on Streptococcus mutans biofilm through teeth whitening light emitting diode (LED). Planktonic and dynamic biofilm state cultures of S. mutans were used. Erythrosine 20 μM/L was used as the photosensitizer. Irradiation was performed by exposing cultures to clinic and homecare whitening LEDs for 15 minutes. The viability was measured through Colony Forming Unit counts and confocal laser scanning microscopy. aPDT using whitening LEDs and erythrosine significantly decreased the CFU count of S. mutans compared to that in the control group. Dynamic biofilm group showed more resistant features to aPDT compared with planktonic state. Clinic and homecare whitening LED device showed similar antimicrobial effect. The whitening LED, which could irradiate the entire oral arch, showed a significant photodynamic effect on cariogenic S. mutans biofilm. aPDT mediated by erythrosine and LEDs used for teeth whitening exhibited promising antimicrobial activity.

Efficacy of Lactobacillus Acidophilus in Treatment of Acute Diarrhea in Children (소아의 급성 설사에서 Lactobacillus Acidophilus의 치료 효과)

  • Han, Hye Jung;Han, Hye Jung;Lee, Hye Sun;Lee, In Sil;Yang, Hae Joung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.24-30
    • /
    • 2004
  • Purpose: Acute diarrhea in young children is a major problem in pediatric hospitals worldwide. We evaluated the clinical efficacy of orally administered Lactobacillus acidophilus in the treatment of acute diarrhea in children. Methods: From September 2002 to July 2003 at National Police Hospital 41 children aged 3 months to 5 years with acute diarrhea were enrolled in this study. The patients were randomized to one of two groups to receive either $0.5{\times}10^8$ colony forming unit (CFU) of L. acidophilus or matching placebo on admission and every 8 hours during hospitalization. Results: The mean duration of diarrhea in all 41 children was decreased (p=0.001) in the L. acidophilus (40.5 hours) group compared to the placebo (56.6 hours) group. Stool frequency was also reduced (p=0.01) on the 3rd day in the L. acidophilus group. Rotavirus was identified in 58% of the patients. The decrease of duration of diarrhea was more significant in rotavirus-negative patients (p=0.002) compared to the rotavirus-positive patients (p=0.027). Conclusion: L. acidophilus shows to be an effective therapeutic agent in acute diarrhea in children. Further studies are needed to confirm the present findings.

  • PDF

Monitoring of Microbial Contaminants in Processing Line of Some Mushromm Canneries (양송이 통조림 공장의 미생물 오염도 변화 추적)

  • 신동화;홍재식
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 1989
  • Three mushroom cannerries were selected by size which are representative vegetable processing firms in korea for monitoring microbial contamination of processing water, washing water, mushroom before and after washing through first and second washing tanks and, blanched and prolonged mushroom for certain time at room temperature. Total contamination degree was expressed as colony forming unit (CFU) of mesophilic aerobes. The contamination degree of processing water was $10^{2}\;CFU/100\;ml$ and washing water in first and second washing tank were 10 to 100 times higher than processing water. When 2.3 tons of washing water was used for washing 1 ton of mushroom, washing effect was showed by reduction of microbial load but cutting it to 1.8 tonsIl ton of mushroom, microbial load was higher than that of raw mushroom level. Blanching reduced microbial load to 50-500 CFU/g of blanched mushroom and it was not seen much increase of CFU in blanched mushroom left at room temperature for 3 hours in $16^{\circ}C$ processing water. Just after injection of $80^{\circ}C$ brine in container, CFU/ml of brine in container was $84{\times}10^{4}$ but it was increased rapidly to $20{\times}10^{7}$ after 2 hours at ambient temperature.

  • PDF

Effect of Photothermal Therapy with Indocyanine Green in Multispecies Biofilm (Indocyanine Green을 이용한 광열 치료의 다종 우식원성 바이오필름에 대한 효과)

  • Kim, Myunghwan;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.21-30
    • /
    • 2021
  • The purpose of this study is to investigate the antibacterial effects of indocyanine green (ICG) and near-infrared diode lasers on multispecies biofilms. Multispecies biofilms of Streptococcus mutans, Lactobacillus casei and Candida albicans were treated with different irradiation time using photosensitizer ICG and 808 nm near-infrared diode laser. Colony forming unit (CFU) was measured, and qualitative evaluation of biofilm was performed with confocal laser scanning microscopy (CLSM). Temperature measurement was conducted to evaluate photothermal effect. In the groups using ICG and diode laser, reduction in CFU was statistically significant, but the difference in antibacterial effect on L. casei and C. albicans with irradiation time was not significant, and similar results were confirmed with CLSM. Groups with ICG and diode laser showed higher temperature elevation than groups without ICG, and results of measured temperature were similar to the range of hyperthermia. In conclusion, ICG and near-infrared diode laser showed antibacterial effects on multispecies biofilms, but studies on protocol are necessary for clinical application.

Study on the Discoloration Identified from the Column of Wooden house, Hyunchungsa(Shrine) - Focused on Influence of Microorganisms and Correlation with Strength - (현충사 옛집의 기둥 하부 변색에 관한 연구 - 미생물에 의한 영향 및 강도와의 상관관계를 중심으로 -)

  • Jeong, So-young;Seo, Min-seok;Hong, Jin-young;Kim, Soo-ji;Jeong, Ah-ruem;Kim, Ji-seo
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.4
    • /
    • pp.58-73
    • /
    • 2014
  • In general, it is thought discoloration on wood is frequently found in decorative wood products. So this study was conducted focusing on white rot found lower parts of columns and baseboards of a wooden house, Hyunchungsa (shrine) to know whether microorganisms have any influence on discoloration or there is correlation with strength by investigating resistograph, occurrence of microorganisms and microscopy for analysis(SEM, tissue analysis etc.). The results obtained were as follows: (1) The result of measurement of resistograph showed there are little correlation between discoloration and strength though there was a spot indicating low resistance. (2) The moisture content of discolored part was relatively higher than that of normal parts, but occurrence of microorganisms was less in discolored parts while more kinds of microorganisms were identified in normal parts with high CFU(Colony Forming Unit). (3) The result of SEM (with a magnification of 500 times) on the surface of discolored parts, it was found out there are many kinds of particles in different sizes on the surface and those were composed of elements such as C, O, Si, Ca, and a small amount of Na and Cl (weight %) were detected in part. (4) The result of tissue analysis showed discoloration occurs limitedly to the outer surface of column. As these results, it is concluded that discoloration has nothing to do with strength, damage by microorganisms and salt.

A Convergence Study on the Measurement of Bacterial Pollution in Medical Ultrasonic Practice (의료용 초음파 실습 시 장치의 세균오염도 측정에 관한 융합적 연구)

  • Kim, Dong-Heun;Park, Sang-Hee;Park, Gyu-Tae;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.75-80
    • /
    • 2019
  • During the medical ultrasound exercise at school, we randomly select parts of the ultrasound device and areas with the most contact in the abdominal phantom to detect bacteria that are above the probe and determine the number of pathogens. I want to find out. The experimental method was rubbed 20 times with the sterilized cotton swab for sterilization and then smeared on Lysogeny broth (LB) agar, put into the incubator and incubated for 48 hours, and the colony forming unit (CFU) count was measured. The bacterial distribution of probe handle and abdominal phantom was evaluated by evaluation. As a result, the CFU value is the lens was $3.0{\pm}0.87$, print button was $5.5{\pm}1.06$, freeze button was $8.0{\pm}4.95$, phantom was $20.0{\pm}2.78$, line was $23.5{\pm}2.50$, and probe handle was measured as $35.3{\pm}10.75$. In this study, it is expected that attention to infection control of equipment during practice during medical ultrasound practice can be highlighted and further contributed to the reduction of bacterial infection rate of ultrasound devices.

Research on ANIOS Disinfection Efficiency to Prevent Infection in Radiography Room (방사선촬영실 감염 방지를 위한 에니오설프의 소독효율 연구)

  • Jung, Woo-Chan;Ahn, Ki-Song;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.55-61
    • /
    • 2021
  • In this study, microbes were collected before and after disinfection using ANIOS(ANIOSURF Premium NPC) and compared the areas where the radiological technologist and the patient frequently contacted the chest X-ray. From September 1st to September 7th, 2020. in P Hospital in Deagu, 4 region were collected in a 10×10 size using a sterile cotton swab of the transport medium, and before and after disinfection results were obtained through the colorimetric method. As a result, n the X-ray tube handle Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp., Candida spp., and in the Chin region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM, and in the Chest region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, and in the Palm region NTM, Candida spp. were detected, and 103 CFU(Colony Forming Unit) or more were measured. After disinfection, only X-ray tube handle was detect Bacillus spp. and more than 102 CFU was measured. Microorganisms found prior to disinfection can cause opportunistic infections, Experimental results showed that Aniosulf(0.25%) is more economical and disinfectant than ethanol(70-90%) and isopropyl alcohol(70-90%). However, further research is needed on the detection of Bacillus spp. resultingly this research is useful basic data of infection control in Radiography room and prevention secondary infections.