• Title/Summary/Keyword: Cold water storage system

Search Result 48, Processing Time 0.042 seconds

Experiment of Characteristic on the Charge and Discharge of Cold for In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열 시스템의 축방냉 특성)

  • Jang, Y.S.;Choi, I.S.;Moon, C.G.;Chun, S.H.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.268-273
    • /
    • 2001
  • A fundamental study on the harvest-type ice storage system applied ice making method in-water and its temperature characteristics in ice storage system was performed experimentally of the charge and discharge of cold. This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks.

  • PDF

Experiment of Characteristic on the Charge and Discharge of Cold in Ice Storage System Applied Ice Making Method In-Water (수중 빙 제조방식을 적용한 빙축열시스템의 축방냉 특성 실험)

  • 최인수;김재돌;윤정인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks. The results showed discharge of cold capacity of new type indicated the high values about 30~40% based on five time of drive, the temperature difference of inlet/outlet occurred the big range about $1.3^{\circ}C$. So, the new type which makes ice in water showed superiorly.

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Characteristics of Storage Tank on Harvest Type Ice Storage System (하베스트형 빙축열시스템의 축열조 특성)

  • Choi, In-Su;Lee, Ho-Saeng;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.210-215
    • /
    • 2000
  • A fundamental study on the under water harvest-type ice storage system and its temperature characteristics in ice storage system was performed experimentally. The experiments were conducted by changing the inlet refrigerant temperature of an evaporator to analyzing the thermal fluid motion inside the ice storage tank. From the experimental results, the cold storage characteristics were investigated by measuring the axial and radial temperature variations inside the ice storage tank with respect to the inlet and outlet refrigerant temperatures of an evaporator. In case of the under water harvest-type ice storage system, thermal fluid motion inside the ice storage tank was shown differently in comparison with that of other ice storage systems. During the cooling storage process, there was no supercooling phenomenon in the ice storage tank. These results show the characteristic of this system and the possibility of application to other fields.

  • PDF

Experimental Study on the Performance Characteristic in Underwater Harvest-Type Ice Storage System (수중 빙제조형 빙축열시스템의 성능특성 특성)

  • Jang, Yong-Sik;Lee, Ho-Saeng;Choi, In-Su;Kim, Jae-Dol;Kim, Eun-Pil;Yoon, Jung-In
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.298-303
    • /
    • 2001
  • A fundamental study on the under water harvest-type ice storage system and its temperature characteristics in ice storage system was performed experimentally. The experiments were conducted by changing the inlet refrigerant temperature of an evaporator to analyzing the thermal fluid motion inside the ice storage tank. From the experimental results, the cold storage characteristics were investigated by measuring the axial and radial temperature variations inside the ice storage tank with respect to the inlet and outlet refrigerant temperatures of an evaporator. In case of the under water harvest-type ice storage system, thermal fluid. motion inside the ice storage tank was shown differently in comparison with that of other ice storage systems. During the cooling storage process, there was no supercooling phenomenon in the ice storage tank. These results show the characteristic of this system and the possibility of application to other fields.

  • PDF

Manufacture of Water-Resistant Corrugated Fiberboard Boxes for Agricultural Products in the Cold Chain System (IV) - Measurement and analysis of storage condition, distribution route, and packaging method for selected agricultural products - (농산물 저온유통용 내수골판지 상자의 제조(제4보) - 대상농산물별 저온유통조건, 유통경로 및 포장규격 조사 분석 -)

  • Lee Myoung-Hoon;Jo Jung-Yeon;Min Choon-Ki;Shin Jun-Seop
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.1 s.113
    • /
    • pp.62-69
    • /
    • 2006
  • This study was carried out to measure and analyze the storage condition, distribution route, and packaging method of four selected agricultural products(small tomato, cabbage, peach, and carrot) in the cold chain system. It was shown that dew-forming phenomenon by fruits and vegetables deteriorates the agricultural product quality and physical properties of corrugated fiberboard box during the cold chain system. The compressive strength deterioration in corrugated fiberboard boxes was much greater for single wall(SW) corrugated fiberboard containers than for double wall(DW) in low temperature-high humidity condition. To reduce the deterioration of box and dew-forming phenomenon, water-repellency treatment should be over $R_6$. However, water-resistant treatment of corrugated fiberboard containers would be effective under high relative humidity conditions more than 75% RH. It was suggested that functional corrugated fiberboard box packaging would be an optimum method to reduce the deterioration of agricultural products quality by. It was also achieved controlling the relative humidity and temperature during the storage and physical distribution process.

Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank (원수열원 히트펌프 축열시스템의 동절기 성능분석)

  • Cho, Yong;Lee, Dong Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

Performance of the Cold Latent Storage System (냉열잠열축열조의 성능해석)

  • Yoon, Ho Sik;Ro, Sung Tack
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.456-465
    • /
    • 1988
  • The performance of the cold latent heat storage is investigated by experiment and by a simplified analytic approach. The heat storage tank has eight horizontal circular tubes and one path of refrigerant evaporating tube. The phase change material in the heat storage tank is water which is frozen by evaporating refrigerant of refrigeration system and melts by the warm air in the heat storage tank. In the experiment, the performance has been studied by the various conditions including the initial water temperature on solidification and flow rate and temperature of air. The rate of recovered heat has been simulated by a simplified model and the results shows a good agreement. In solidification process, initial water temperature causes time delay corresponding to the sensible heat and it is found that the shape of evaporator is important. In melting process, the recovered heat rate from the heat storage tank is proportional to $Re^{0.8}(T_{bi}-T_f)$ of air where $T_{bi}$ and $T_f$ indicate temperatures of inlet air and phase change, respectively. And the deminishing rate of the recovered heat is higher for the higher heat rate.

  • PDF

Experiments on Operation Characteristics of In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열 시스템의 운전특성 실험)

  • Choe, In-Su;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.653-659
    • /
    • 2001
  • This paper is concerned with the development of a new method for making and separating ice in-water and saving floated ice by installing an evaporation panel in an ice storage tank. The new method shows very good heat transfer efficiency than that of the convectional method. It is because the evaporation panel is directly contacted with water in the storage tank. The experiments were performed by varying inlet and outlet refrigerant temperatures of its evaporator. From the experimental results, the operating characteristics of in-water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to operating compressor respect to the changes of the inlet and outlet refrigerant temperature of evaporator. It can be think that defrost frequency decreased and heavy ice created as the refrigerant temperature of evaporator outlet and defrost setting temperature is low so gotten result can effect to release efficiency. Also, consumption power, condensing heat quantity, refrigerating capacity and performance efficiency decreased as time goes by. Therefore, these results provide the basic data for system optimization, performance improvement and the possibility of application to other fields.

Investigation of amorphous material with ice for cold thermal storage

  • Kim, Jhongkwon;Park, Hyunjun;Bae, Junhyuk;Jeong, Sangkwon;Chang, Daejun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.40-44
    • /
    • 2019
  • This study investigates mixtures of water and cryoprotectant agents (CPAs) to store high-grade cold energy. Although water is an ideal material for a cold thermal storage (CTS) due to its high specific heat, undesirable volume expansion may cause structural stresses during freezing. The volume expansion can be alleviated by adding the CPAs to water. However, the CPA aqueous solutions not only have different thermal properties but also transit to amorphous state different from pure water. Therefore, these characteristics should be considered when using them as material of the CTS. In experiments, glycerol and dimethyl sulfoxide (DMSO) are selected as the candidate CPA. The volume expansion of the solution is measured by an in-situ strain gauge in low temperature region. The specific heat capacity of the solution is also measured by differential scanning calorimetry (DSC). Both the amount of volume expansion and the specific heat capacity of the CPA aqueous solution decrease in the case of higher concentration of CPA. These characteristics should be contemplated to select optimal aqueous solution for CTS for liquid air energy storage system (LAES). The CPA solutions have advantages of having wide temperature range to utilize the latent heat of water and higher sensible heat of the CPA. The CPA solutions which can satisfy the allowable stress of the structure are determined. Consequently, among the CPA solutions investigated, DMSO 20% w/w solution is the most suitable for the CTS.