• 제목/요약/키워드: Cold Energy Storage

검색결과 109건 처리시간 0.026초

Enhancement of the round-trip efficiency of liquid air energy storage (LAES) system using cascade cold storage units

  • Kim, Jhongkwon;Byeon, Byeongchang;Kim, Kyoung Joong;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.45-50
    • /
    • 2020
  • In this research, the variation of round-trip efficiency in a liquid air energy storage system (LAES) is calculated and an optimal configuration is found. The multiple stages of cold energy storage are simulated with several materials that process latent heat at different temperature ranges. The effectiveness in the charging and discharging processes of LAES is newly defined, and its relationship with the round-trip efficiency is examined. According to defined correlation, the effectiveness of the discharging process significantly affects the overall system performance. The round-trip efficiency is calculated for the combined cold energy storage materials of aqueous dimethyl sulfoxide (DMSO) solution, ethanol, and pentane theoretically. The performance of LAES varies depending on the freezing point of the cold storage materials. In particular, when the LAES uses several cold storage materials, those materials whose freezing points are close to room temperature and liquid air temperature should be included in the cold storage materials. In this paper, it is assumed that only latent heat is used for cold energy storage, but for more realistic analyzes, the additional consideration of the transient thermal situation to utilize sensible heat is required. In the case of such a dynamic system, since there is certainly more increased heat capacity of the entire storage system, the volume of the cold energy storage system will be greatly reduced.

LNG 냉열이용 지역집단 냉방시스템에 대한 연구 (A Study on the District Community Cooling System using LNG Cold Energy)

  • 김청균;김승철
    • 한국가스학회지
    • /
    • 제14권6호
    • /
    • pp.27-30
    • /
    • 2010
  • 본 논문은 LNG 냉열에너지를 이용한 지역집단 냉방에너지 시스템을 공급하기 위한 시스템 공정설계에 관한 연구이다. 새로이 개발한 LNG 냉방시스템은 여러 개의 열교환기, LNG 저장탱크, 열매체 저장탱크, 여러 개의 냉열에너지 저장탱크, 가스냉방기, 압축기, 정압기, 저온 및 고온에너지 공급배관 등으로 구성되도록 설계하였다. 또한, 가스냉방기는 여름철에 도시가스 소모량에 의해 충분하지 못한 LNG 냉열에너지를 안정적으로 공급하기 위해 설치되었다. 냉방에너지 공급시스템은 공기라는 열매체와 200kcal/kg의 냉열에너지를 가진 LNG 사이의 열교환 작용에 의해 냉방에너지를 공급하는 효율성과 안전성을 함께 갖추고 있다. 또한, LNG 냉열에너지를 이용한 지역집단 냉방에너지 공급시스템은 공기중으로 CO2나 프레온 가스를 방출하기 않는다는 장점을 간고 있다.

지중 축냉조에 대한 에너지 시뮬레이션 (Energy Simulation for the Cold Storage Tank in the Ground)

  • 김홍제;양윤섭
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국태양에너지학회, 한국에너지공학회 1993년도 춘계 공동학술발표회 초록집
    • /
    • pp.79-84
    • /
    • 1993
  • The heat transfer process below and adjacent to the cold storage is numerically investigated. The cold storage dimensions, temperatures, insulation thickness, and the initial soil temperature were considered.

  • PDF

직접 접촉식을 이용한 빙축열 시스템 (Cold Energy Storage System Using Direct Contact Heat Transfer)

  • 이윤표;윤성영;이춘식
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.247-258
    • /
    • 1994
  • In this study, experimental investigations to find cold energy storage performance have been made for two different temperatures at condenser. Temperatures at inlet and outlet of condenser were measured to calculate global heat transfer coefficient of direct contact method in our cold energy storage system. Also storage performance by direct contact method was compared with that of Ice-On-Coil type ice storage which was calculated by analytic solution. Results show that, in the case of $-8.0^{\circ}C$ at condenser inlet, heat transfer coefficient of direct contact method is 3.25 times higher than that of conventional method and COP of system is improved by using R141b as refrigerant which produces gas hydrate and has higher phase change temperature than $0.0^{\circ}C$.

  • PDF

LNG 냉열을 활용한 인천항 냉동·냉장 클러스터 입주요인 분석 및 활성화 방안 연구 (An analysis of the Factors of Moving in and Activation Strategies for Incheon Cold-Chain Cluster using LNG cold energy)

  • 안길섭;오재균;양태현;여기태
    • 디지털융복합연구
    • /
    • 제17권2호
    • /
    • pp.101-111
    • /
    • 2019
  • 냉동 냉장창고의 집적단지인 '콜드체인 클러스터' 구축이 물류업계의 현안으로 급부상하고 있다. 인천항만공사는 한국가스공사와 협력하여 송도 LNG 인수기지에서 발생하는 냉열 에너지를 이용한 냉동 냉장 클러스터를 구축하기 위한 사업을 진행 중에 있다. 본 연구에서는 CFPR 방법론을 활용하여 냉동 냉장 클러스터 활성화 방안을 제시하는 것을 연구의 목적으로 한다. 분석결과, 상위요인에서는 안정성과 수익성 요인이 0.281로 가장 중요시 되는 요인으로 파악되었다. 세부요인으로는 지속가능한 물동량 확보가 가장 높게 나타났고, 임대료 수준, LNG 냉열 활용기술의 지속 가능성과 일반 냉동 냉장창고와의 경쟁, 시설 중복투자 배제 등의 순으로 중요도가 평가 되었다. 향후 연구에서는 활성화 요인을 활용하여 국내 지역별 냉동냉장클러스터를 평가할 필요가 있다.

잠열물질을 이용한 열저장 기술에 관한 연구 (Study of Thermal Storage Technology using Phase Change Material)

  • 김정열;정동열;박동호;백종현
    • 융복합기술연구소 논문집
    • /
    • 제2권1호
    • /
    • pp.1-6
    • /
    • 2012
  • The cold chain system in South-East Asia is requiring to maintain freshness of refrigerated or frozen food. In this study, Thermal storage system using Phase change material (PCM) was developed and evaluated its performance about temperature and cold keeping time. For various application of cold chain system, we developed portable cold box, cold roll container and freezing station. Keeping time on laboratory tests of portable cold box in case of refrigeration and freezing were 6 hours and 4 hours, respectively. Cold container was developed to 2.5 ton scale. Evaluation in Indonesia, it was showed to keep the setting temperature of $-10^{\circ}C$ over 40 hours at $30^{\circ}C$ of ambient air. Freezing station using PCM was kept over 24 hours under $-20^{\circ}C$.

  • PDF

과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구 (Experimental Study on The Running Characteristics of Showcase Using Cold Storage System)

  • 이동원;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.

빙축열시스템의 실질적인 최대 축열 가능량 예측 (Prediction of practically chargeable cold energy in an ice storage system)

  • 이대영;강병하;김민수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

축냉 시스템을 적용한 쇼케이스 운전에 대한 실험적 연구 (Experimental Study of Showcase Using Cold Storage System)

  • 이은지;이동원;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1111-1116
    • /
    • 2008
  • The purpose of this study is to maintain high efficiency and reasonable use of cold-heat storage systems operated the showcase. An experimental study is carried out to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that at the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling.

  • PDF

쇼케이스 운전상태를 고려한 축냉시스템 적용타당성 연구 (A study on the Cold-heat Storage System for Operation Status Monitoring of Showcase)

  • 이은지;이동원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1261-1266
    • /
    • 2008
  • Experimental study was performed to understand the operations of a showcase working in a discount store. Temperatures of evaporation, condenser were measured and also electric power consumption of compressor were measured. The purpose of this study is to application use of cold-heat storage systems operated the showcase. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling. So the operating characteristics of the showcase system under various working conditions were analyzed and discussed.

  • PDF