Experimental Study of Showcase Using Cold Storage System

축냉 시스템을 적용한 쇼케이스 운전에 대한 실험적 연구

  • Lee, Eun-Ji (Division of Renewable Energy Research, Korea Institute of Energy Research) ;
  • Lee, Dong-Won (Division of Renewable Energy Research, Korea Institute of Energy Research) ;
  • Kim, Yong-Chan (Department of Mechanical Engineering, Korea University)
  • Published : 2008.06.25

Abstract

The purpose of this study is to maintain high efficiency and reasonable use of cold-heat storage systems operated the showcase. An experimental study is carried out to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that at the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling.