• Title/Summary/Keyword: Coincidence set

Search Result 34, Processing Time 0.019 seconds

COUPLED FIXED POINT THEOREMS FOR RATIONAL INEQUALITY IN GENERALIZED METRIC SPACES

  • Singh, Deepak;Tomar, Surjeet Singh;Rathore, M.S.;Chauhan, Varsha
    • East Asian mathematical journal
    • /
    • v.31 no.1
    • /
    • pp.65-75
    • /
    • 2015
  • In modern times, coupled fixed point theorems have been rigorously studied by many researchers in the milieu of partially ordered G-metric spaces using different contractive conditions. In this note, some coupled fixed point theorems using mixed monotone property in partially ordered G-metric spaces are obtained. Furthermore some theorems by omitting the completeness on the space and continuity conditions on function, are obtained. Our results partially generalize some existing results in the present literature. To exemplify our results and to distinguish them from the existing ones, we equip the article with suitable examples.

Development of a System to Measure Quality of Cut Flowers of Rose and Chrysanthemum Using Machine Vision (기계시각을 이용한 장미와 국화 절화의 품질 계측장치 개발)

  • 서상룡;최승묵;조남홍;박종률
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.231-238
    • /
    • 2003
  • Rose and chrysanthemum are the most popular flowers in Korean floriculture. Sorting flowers is a labor intensive operation in cultivation of the cut flowers and needed to be mechanized. Machine vision is one of the promising solutions for this purpose. This study was carried out to develop hardware and software of a cut flower sorting system using machine vision and to test its performance. Results of this study were summarized as following; 1. Length of the cut flower measured by the machine vision system showed a good correlation with actual length of the flower at a level of the coefficients of determination (R$^2$) of 0.9948 and 0.9993 for rose and chrysanthemum respectively and average measurement errors of the system were about 2% and 1% of the shortest length of the sample flowers. The experimental result showed that the machine vision system could be used successfully to measure length of the cut flowers. 2. Stem diameter of the cut flowers measured by the machine vision system showed a correlation with actual diameter at the coefficients of determination (R$^2$) of 0.8429 and 0.9380 for rose and chrysanthemum respectively and average measurement errors of the system were about 15% and 7.5% of the shortest diameter of the sample flowers which could be a serious source of error in grading operation. It was recommended that the error rate should be considered to set up grading conditions of each class of the cut flowers. 3. Bud maturity of 20 flowers each judged using the machine vision system showed a coincidence with the judgement by inspectors at ranges of 80%∼85% and 85%∼90% for rose and chrysanthemum respectively. Performance of the machine vision system to judge bud maturity could be improved through setting up more precise criteria to judge the maturity with more samples of the flowers. 4. Quality of flower judged by stem curvature using the machine vision system showed a coincidence with the judgement by inspectors at 90% for good and 85% for bad flowers of both rose and chrysanthemum. The levels of coincidence was considered as that the machine vision system used was an acceptable system to judge the quality of flower by stem curvature.

A Comparison of coincidence between the Light field & the Radiation field using film and BIS (필름과 BIS 영상장치를 이용한 광/방사선조사야 일치성 비교평가)

  • Bang, Dong-Wan;Seok, Jin-Yong;Jeong, Yun-Ju;Choi, Byeong-Don;Park, Jin-Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2004
  • Purpose : Film has been the primary tool in coincidence testing between the light field and the radiation field, which constitutes the quality assurance list of a linear accelerator. But there is a great chance of errors being different among the observer when using film. Thus this study set out to use the BIS(Beam Image System) in addition to film in comparing and evaluating coincidence results between the two fields and in searching for the improvement measures. Materials & Methods : Photon beam of 6 and 15MV was exposed to film and the BIS using a linear accelerator. The light and radiation fields were each $50{\times}50,\;100{\times}100,\;and\;200{\times}200mm^2$. The gantry angle was $0^{\circ}$ when using film and $0^{\circ}\;and\;270^{\circ}$ when using the BIS. The devices adopted to test coincidence between the two fields were a ruler and film scanner when using film. With the BIS, the width of the scanned light and radiation fields was measured for errors with setting the X and Y axis. Results : The visual measurements of the observer with film resulted that the radiation field was bigger than the light field and that their maximum error was 1.9mm. The results were the same with the measurements using the film scanner except for the average error, which was less than 1.9mm. On the contrary, the measurements using the BIS showed that the light field was bigger than the radiation field at the gantry angle of $0^{\circ}\;and\;270^{\circ}$. The maximum error was 0.96mm, and the error range was $<{\pm}2mm$ both in the X and Y axis. The average error of ${\Delta}X$, Y was the smallest in the order of the visual film measurements, film scanner measurements, and BIS measurements Conclusion . This requires a careful measurement for accurate quality assurance since errors are much different according to each observer that tests coincidence between visual fields with film. And an observer needs to use another image device or develop a measuring device of his own if it seems necessary for accurate measurements.

  • PDF

Steady-Flow Characteristics of Bundle Fluid in Drawing (인발 집속유체의 정상유동 특성)

  • Huh You;Kim Jong-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.612-621
    • /
    • 2006
  • Drawing is a mechanical operation attenuating material thickness to an appropriate level for the next processing or end usage. When the input material has a form of bundle or bundles made of very thin and long shaped wires or fibers, this attenuation operation is called 'bundle drawing' or 'drafting'. Bundle drawing is being used widely in manufacturing micro sized wires or staple yarns. However, the bundle processed by this operation has more or less defects in the evenness of linear density. Such irregularities cause many problems not only for the product quality but also for the efficiency of the next successive processes. In this research a mathematical model for the dynamic behavior of the bundle fluid is to be set up on the basis of general physical laws containing physical variables, i.e. linear density and velocity as the dynamic state variables of the bundle fluid. The governing equations resulting from the modeling show that they appear in a slightly different form from what they do in a continuum fluid. Then, the governing equations system is simplified in a steady state and the bundle dynamics is simulated, showing that the shape of the velocity profiles depends on two model parameters. Experiments confirm that the model parameters are to be well adjusted to show a coincidence with the theoretical analysis. The higher the drawing ratio and drawing speed we, the more sensitive becomes the bundle flow to exogenous disturbances.

A Study on the Interpolation Characteristics of the Scattered Geographic Data according to the Gridding methods (격자화 기법에 따른 이산지형정보의 보간특성 연구)

  • Lee, Yong-Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.4 no.2 s.8
    • /
    • pp.173-180
    • /
    • 1996
  • In a grid based data transformation, the different gridding methods provide different interpretations of scattered data because each method calculate grid node values using a different weighted mathematical algorithms. Therefore, it is necessary to review the interpolated characteristics of some gridding methods according to search distance, search area and search options before determing the best method with a data set. For this, in this paper, six different gridding methods with the same search conditions are applied to a scattered data obtained from sterro-plotter. The interpolated characteristics of the scattered geographic data considered through comparison of coincidence between the data point and the grid node being interpolated. And also, shows the real application of gridding methods through calculating volumes and creating cross sections.

  • PDF

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.

Studies about Changes in Modern Korean Font and Effect of Digital Font to Caligraphy Design Thinking of Korea (근현대 한글 컴퓨터서체의 변화와 디지털폰트가 Caligraphy에 준 영향에 관한 연구)

  • Lee, Sung-Soo;Choi, Byoung-Mook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.159-163
    • /
    • 2008
  • Recently, typography in Korea has been varied. Among them, after 2005 a new trend caligraphy has appeared and in reality people discussed that this has been occurred as a coincidence. However, as a view of one who is interested in Hangeul typography, born of Hangeul caligraphy is not a coincidence. It is because computerizing of Hangeul has been later than U.S. or Japan. Korea was colonized by Japan and experienced the Korean War and economical independence got late and cultural independence got late as well. Our language, Hangeul was independenced in the beginning of 1990's after computer was introduce and original letter of Hangeul was scanned and basic standard was built. From the end of 80's there were many efforts for independence of Hangeul but there were problems on hardware side than software side. In the beginning of 90's basic fonts such as Myungjo or Gothic of Choi Jung-ho's fonts were set for computer hardware, but later 90's can be called as a time for distributing designed fonts for that new fonts that were planned and applying new ideas on fonts were done. In 2000 the two major font company in Korea Sandoll Communication and Yoon Design Institute made a fonts such as When branding had to be done by designer, typo must be written so adjusting size and moving baseline made old style and caligraphy fonts to be born. These cycling process has been natural motive for nowadays' caligraphy and these two major companies' role has made caligraphy to be popular.

  • PDF

Research of Grip Forces and Subjective Preferences for Various Individual Finger Grip Spans by using an (MFFM System을 이용한 손가락 별 파지 폭들의 변화에 따른 악력 및 개인 선호도에 대한 연구)

  • Kim, Dae-Min;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • Individual finger/total grip forces, and subjective preferences for various individual finger grip spans (i.e., four fingers had identical grip spans or different grip spans) were evaluated by using an "Adjustable Multi-Finger Force Measurement (MFFM) System". In this study, three grip spans were defined as follows: a 'favorite grip span' which is the span with the highest subjective preference; a 'maximum grip span' which is the span with the highest total grip force; a 'maximum finger grip span' which is a set of four grip spans that had maximum finger grip forces associated with the index, middle, ring, and little fingers, respectively. Ten males were recruited from university population for this study. In experiment I, each participant tested the maximum grip force with five grip spans (45 to 65mm) to investigate grip forces and subjective preferences for three types of grip spans. Results showed that subjective preferences for grip spans were not coincidence with the performance of total grip forces. It was noted that the 'favorite grip span' represented the lowest total grip force, whereas the 'maximum finger grip span' showed the lowest subjective preferences. The individual finger forces and the average percentage contribution to the total finger force were also investigated in this study. The findings of this study might be valuable information for designing ergonomics hand-tools to reduce finger/hand stress as well as to improve tool users' preferences and performance.

The investigation of a new fast timing system based on DRS4 waveform sampling system

  • Zhang, Xiuling;Du, Chengming;Chen, Jinda;Yang, Herun;kong, Jie;Yang, Haibo;Ma, Peng;Shi, Guozhu;Duan, limin;Hu, Zhengguo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.432-438
    • /
    • 2019
  • In the study of nuclear structure, the fast timing technique can be used to measure the lifetime of excited states. In the paper, we have developed a new fast timing system, which is made up of two $LaBr_3:Ce$ detectors and a set of waveform sampling system. The sampling system based on domino ring sampler version 4 chip (DRS4) can digitize and store the waveform information of detector signal, with a smaller volume and higher timing accuracy, and the waveform data are performed by means of digital waveform analysis methods. The coincidence time resolution of the fast timing system for two annihilation 511 keV ${\gamma}$ photon is 200ps (FWHM), the energy resolution is 3.5%@511 keV, and the energy linear response in the large dynamic range is perfect. Meanwhile, to verify the fast timing performance of the system, the $^{152}Gd-2_1^+$ state form ${\beta}^+$ decay of $^{152}Eu$ source is measured. The measured lifetime is $45.3({\pm}5.0)ps$, very close to the value of the National Nuclear Data Center (NNDC: $46.2({\pm}3.9)ps$). The experimental results indicate that the fast timing system is capable of measuring the lifetime of dozens of ps. Therefore, the system can be widely used in the research of the fast timing technology.

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF