• 제목/요약/키워드: Coherence imaging

검색결과 127건 처리시간 0.019초

Low coherence 특성의 SLD를 이용한 2차원 OCT 영상 구현 (2-D OCT image implementation using low coherence SLD)

  • 정태호;박양하;오상기;김용평
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.290-291
    • /
    • 2003
  • Optical Coherence Tomography is a new medical dianostic imaging technology which can perform micron resolution cross-sectional or tomograpic imaging in biological tissue. In this paper, we analyze OCT system. And we have 2-dimensional OCT image implementation using low coherence SLD.

  • PDF

Coherence Gated Three-dimensional Imaging System using Organic Photorefractive Holography

  • Hwang, Ui-Jung;Choi, Jongwan;Kim, Chuntae;Kim, Won-Guen;Oh, Jin-Woo;Kim, Nakjoong
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.938-940
    • /
    • 2014
  • This paper discusses a coherence-gated three-dimensional imaging system based on photorefractive holography, which was applied to imaging through turbid media with a view to developing biomedical instrumentation. A rapid response photorefractive device doped with 2,4,7-trinitro-9-fluorenylidene malononitrile was used to generate the hologram grating. The estimated depth resolution was $20{\mu}m$, which corresponds to the coherence length of the light source. In this coherence imaging system, tomographic imaging of a 3-dimensional object composed of a $50{\mu}m$ thick cylindrical layer was achieved. The proposed coherence imaging system using an organic photorefractive material can be used as an optical tomography system for biological applications.

Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing

  • Kang, Jin-U.;Han, Jae-Ho;Liu, Xuan;Zhang, Kang
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.1-13
    • /
    • 2010
  • This paper describes a development of a fiber optic common-path optical coherence tomography (OCT) based imaging and guided system that possess ability to reliably identify optically transparent targets that are on the micron scale; ability to maintain a precise and safe position from the target; ability to provide spectroscopic imaging; ability to imaging biological target in 3-D. The system is based on a high resolution fiber optic Common-Path OCT (CP-OCT) that can be integrated into various mini-probes and tools. The system is capable of obtaining >70K A-scan per second with a resolution better than $3\;{\mu}m$. We have demonstrated that the system is capable of one-dimensional real-time depth tracking, tool motion limiting and motion compensation, oxygen-saturation level imaging, and high resolution 3-D images for various biomedical applications.

Beam-scanning Imaging Needle for Endoscopic Optical Coherence Tomography

  • Yang, Woohyeok;Hwang, Junyoung;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • 제5권5호
    • /
    • pp.532-537
    • /
    • 2021
  • We present a compact endoscopic probe in a needle form which has a fast beam-scanning capability for optical coherence tomography (OCT). In our study, a beam-scanning OCT imaging needle was fabricated with a 26G syringe needle (0.46 mm in outer diameter) and a thin OCT imaging probe based on the stepwise transitional core (STC) fiber. The imaging probe could freely rotate inside the needle for beam scans. Hence, OCT imaging could be performed without rotation or translation of the needle body. In our design, the structural integrity of the needle's steel tubing was preserved for mechanical robustness. Probing the optical signal was performed through the needle's own window formed at the end. For hand-held operation of our imaging needle, a light and compact scanner module (130 g and 45 × 53 × 60 mm3) was devised. Connected to the imaging needle, it could provide rotational actuation driven by a galvanometer. Because of its finite actuation range, our scanner module did not need a fiber rotary joint which might add undesirable complexity. The beam scan speed was 20 Hz and supported 20 frames per second at the maximum for endoscopic OCT imaging.

표면 추적 알고리즘을 적용한 공통경로 FD-OCT의 성능개선 (Enhancement of Common-path Fourier-domain Optical Coherence Tomography using Active Surface Tracking Algorithm)

  • 김민호;김거식;송철규
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.639-642
    • /
    • 2012
  • Optical coherence tomography(OCT) can provide real-time and non-invasive subsurface imaging with ultra-high resolution of micrometer scale. However, conventional OCT systems generally have a limited imaging depth range within a depth of only 1-2 mm. To overcome the limitation, we have proposed an active surface tracking algorithm used in common-path Fourier-domain OCT system in order to extend the imaging depth range. The surface tracking algorithm based on the threshold and Savitzky-Golay filter of A-scan data was applied to real-time tracking. The algorithm has controlled a moving stage according to the sample's surface variance in real time. An OCT image obtained by the algorithm clearly show an extended imaging depth range. Consequently, the proposed algorithm demonstrated the potential for improving the conventional OCT systems with limitary depth range.

광간섭 단층 영상기술을 이용한 생체 내 microneedle 삽입 구조 영상 (High-resolution imaging of microneedles in biological tissue with optical coherence tomography)

  • 김훈;허정;이강주;유수호;류원형;주철민
    • 정보저장시스템학회논문집
    • /
    • 제9권1호
    • /
    • pp.17-21
    • /
    • 2013
  • Optical coherence tomography (OCT) allows non-invasive, cross-sectional optical imaging of biological tissue with high spatial resolution and acquisition speed. In principle, it is analogous to ultrasound imaging, but uses near-infrared light instead of ultrasound, measuring the time-delay of back-scattered light from within biological tissue. Compared to ultrasound imaging, it exhibits superior spatial resolution (1~10 um) and high sensitivity. Therefore, OCT has been applied to a wide range of applications such as cellular imaging, ophthalmology and cardiology. Here, we describe a novel application of OCT technology in visualizing microneedles embedded in tissue that is developed to deliver drugs into the dermis without the injection mark in the human skin. Detailed three-dimensional structural images of microneedles and biological tissues were obtained. Examining structural modification of microneedles and tissues during insertion process would enable to evaluate performance of various types of microneedles in situ.

Optimized Working Distance of a Micro-optic OCT Imaging Probe

  • Kim, Da-Seul;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.330-335
    • /
    • 2020
  • We have investigated optimization of the working distance (WD) for a highly miniaturized imaging probe for endoscopic optical coherence tomography (OCT). The WD is the axial distance from the distal end of the imaging probe to its beam focus, which is demanded for dimensional margins of protective structures, operational safety, or full utilization of the axial imaging range of OCT. With an objective lens smaller than a few hundred micrometers in diameter, a micro-optic imaging probe naturally exhibits a very short WD due to the down-scaled optical structure. For a maximized WD careful design is required with the optical aperture of the objective lens optimally filled by the incident beam. The diffraction-involved effect was taken into account in our analysis of the apertured beam. In this study, we developed a simple design formula on the maximum achievable WD based on our diffraction simulation. It was found that the maximum WD is proportional to the aperture size squared. In experiment, we designed and fabricated very compact OCT probes with long WDs. Our 165-㎛-thick fiber-optic probes provided WDs of 3 mm or longer w ith reasonable OCT imaging performance.

치석 진단용 소형 프로브 기반 광간섭단층촬영 시스템 (A Handheld Probe Based Optical Coherence Tomography System for Diagnosis of Dental Calculus)

  • 이창호;우채경;정웅규;강현욱;오정환;김지현
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.217-222
    • /
    • 2012
  • Optical coherence tomography(OCT) is a noninvasive optical imaging tool for biomedical applications. OCT can provide depth resolved two/three dimensional morphological images on biological samples. In this paper, we integrated an OCT system that was composed of an SLED(Superluminescent Light Emitting Diode, ${\lambda}_0$=1305 nm bandwith= 141 nm), a reference arm adopting a rapid scanning optical delay line(RSOD) to get high speed imaging, and a sample arm that used a micro electro mechanical systems(MEMS) scanning mirror. The sample arm contained a compact probe for imaging dental structures. The performance of the system was evaluated by imaging in-vivo human teeth with dental calculus, and the results indicated distinct appearance of dental calculus from enamel, gum or decayed teeth. The developed probe and system could successfully confirm the presence of dental calculus with a very high spatial resolution($6{\mu}m$).

Optical Coherence Tomography Based on a Continuous-wave Supercontinuum Seeded by Erbium-doped Fiber's Amplified Spontaneous Emission

  • Lee, Ju-Han;Jung, Eun-Joo;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.49-54
    • /
    • 2010
  • In this study, the use of a continuous-wave (CW) supercontinuum (SC) seeded by an erbium-doped fiber's amplified spontaneous emission (ASE) for optical-coherence tomography imaging is experimentally demonstrated. It was shown, by taking an in-depth image of a human tooth sample, that due to the smooth, flat spectrum and long-term stability of the proposed CW SC, it can be readily applied to the spectral-domain optical-coherence tomography system. The relative-intensity noise level and spectral bandwidth of the CW SC are also experimentally analyzed as a function of the ASE beam power.

Applications of Optical Imaging System in Dentistry

  • Eom, Joo Beom;Park, Anjin
    • Medical Lasers
    • /
    • 제9권1호
    • /
    • pp.25-33
    • /
    • 2020
  • Optical-based imaging technology has high resolution and can assess images in real time. Numerous studies have been conducted for its application in the dental field. The current research introduces an oral camera that includes fluorescent imaging, a second study examining a 3D intraoral scanner applying a confocal method and a polarization structure that identifies the 3D image of a tooth, and finally, an optical coherence tomography technique. Using this technique, we introduce a new concept 3D oral scanner that simultaneously implements 3D structural imaging as well as images that diagnose the inside of teeth. With the development of light source technology and detector technology, various optical-based imaging technologies are expected to be applied in dentistry.