• Title/Summary/Keyword: Coefficient Method

Search Result 8,958, Processing Time 0.049 seconds

Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition (전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Jongmin
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.15-27
    • /
    • 2020
  • Streamflow discharge as a fundamental riverine quantity plays a crucial role in water resources management, thereby requiring accurate in-situ measurement. Recent advances in instrumentations for the streamflow discharge measurement has complemented or substituted classical devices and methods. Among various potential methods, surface current meter using microwave has increasingly begun to be applied not only for flood but also normal flow discharge measurement, remotely and safely enabling practitioners to measure flow velocity postulating indirect contact. With minimized field preparedness, this method facilitated and eased flood discharge measurement in the difficult in-situ conditions such as extreme flood in active ways emitting 24.125 GHz microwave without relying on natural lights. In South Korea, a rectangular shaped instrument named with Microwave Water Surface Current Meter (MWSCM) has been developed and commercially released around 2010, in which domestic agencies charging on streamflow observation shed lights on this approach regarding it as a potential substitute. Considering this brand-new device highlighted for efficient flow measurement, however, there has been few noticeable efforts in systematic and comprehensive evaluation of its performance in various measurement and riverine conditions that lead to lack in imminent and widely spreading usages in practices. This study attempted to evaluate the MWSCM in terms of instrumen's monitoring configuration particularly regarding tilt and yaw angle. In the middle of pointing the measurement spot in a given cross-section, the observation campaign inevitably poses accuracy issues related with different tilt and yaw angles of the instrument, which can be a conventionally major source of errors for this type of instrument. Focusing on the perspective of instrument configuration, the instrument was tested in a controlled outdoor river channel located in KICT River Experiment Center with a fixed flow condition of around 1 m/s flow speed with steady flow supply, 6 m of channel width, and less than 1 m of shallow flow depth, where the detailed velocity measurements with SonTek micro-ADV was used for validation. As results, less than 15 degree in tilting angle generated much higher deviation, and higher yawing angle proportionally increased coefficient of variance. Yaw angles affected accuracy in terms of measurement area.

Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum (AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성)

  • Kim, Yong-Ryul;An, Hyung-Hwan;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.870-877
    • /
    • 1998
  • With impedance spectrum measurements, impedance was studied in the interface between sample solutions for $K^+-ion$ selective PVC membrane electrode containing neutral carriers [dibenzo-18-crown-6 (D18Cr6) and valinomycine (Val)]. Response characteristics of electrode were examined by measuring AC impedance spectra that were resulted from the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, doping of base electrolytes, and concentration variation of sample solution. Transport characteristics of PVC membrane electrode were also studied. It was found that the equivalent circuit for the membrane in $K^+$ solution could be expressed by a series combination of solution resistance and a parallel circuit consisting of the bulk resistance and geometric capacitance of the membrane system. But the charge transfer resistance and Warburg resistance were overlapped a little in the low concentration and low frequency ranges. The carrier, D18Cr6 was best for electrode and impedance characteristics, and ideal electrode characteristics were appeared especially in case of doping of the base electrolyte[potassium tetraphenylborate(TPB)]. The optimum carrier content was about 3.23 wt% in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the impedance characteristics was improved, but electrode characteristics were lowered for membrane thickness below the optimum. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

A Study on Qulity Perceptions and Satisfaction for Medical Service Marketing (의료서비스 마케팅을 위한 품질지각과 만족에 관한 연구)

  • Yoo, Dong-Keun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.1
    • /
    • pp.97-114
    • /
    • 1996
  • INSTRODUCTION Service quality is, unlike goods quality, an abstract and elusive constuct. Service quality and its requirements are not easily understood by consumers, and also present some critical research problems. However, quality is very important to marketers and consumers in that it has many strategic benefits in contributing to profitability of marketing activities and consumers' problem-solving activities. Moreover, despite the phenomenal growth of medical service sector, few researchers have attempted to define and model medical service quality. Especially, little research has focused on the evaluation of medical service quality and patient satisfaction from the perspectives of both the provider and the patient. As competition intensifies and patients are demanding higher quality of medical service, medical service quality and patient satisfaction has emerged as a critical research topic. The major purpose of this article is to explore the concept of medical service quality and its evaluation from both nurse and patient perspectives. This article attempts to achieve its purpose by (1)classfying critical service attibutes into threecategories(satisfiers, hygiene factors, and performance factors). (2)measuring the relative importance of need criteria, (3)evaluating SERVPERF model and SERVQUAL model in medical service sector, and (4)identifying the relationship between perceived quality and overall patient satisfaction. METHOD Data were gathered from a sample of 217 patients and 179 nurses in Seoul-area general hospitals. From the review of previous literature, 50 survey items representing various facets of the medical service quality were developed to form a questionnaire. A five-point scale ranging from "Strongly Agree"(5) to "Strongly Disagree"(1) accompanied each statement(expectation statements, perception statements, and importance statements). To measure overall satisfaction, a seven-point scale was used, ranging from "Very Satisfied"(7) to "Very Dissatisfied"(1) with no verbal labels for scale points 2 through 6 RESULTS In explaining the relationship between perceived performance and overall satisfaction, only 31 variables out of original 50 survey items were proven to be statistically significant. Hence, a penalty-reward analysis was performed on theses 31 critical attributes to find out 17 satisfiers, 8 hygiene factors, and 4 performance factors in patient perspective. The role(category) of each service quality attribute in relation to patient satisfaction was com pared across two groups, that is, patients and nurses. They were little overlapped, suggesting that two groups had different sets of 'perceived quality' attributes. Principal components factor analyses of the patients' and nurses' responses were performed to identify the underlying dimensions for the set of performance(experience) statements. 28 variables were analyzed by using a varimax rotation after deleting three obscure variables. The number of factors to be extracted was determined by evaluating the eigenvalue scores. Six factors wereextracted, accounting for 57.1% of the total variance. Reliability analysis was performed to refine the factors further. Using coefficient alpha, scores of .84 to .65 were obtained. Individual-item analysis indicated that all statements in each of the factors should remain. On 26 attributes of 31 critical service quality attributes, there were gaps between actual patient's importance of need criteria and nurse perceptions of them. Those critical attributes could be classified into four categories based on the relative importance of need criteria and perceived performance from the perspective of patient. This analysis is useful in developing strategic plans for performance improvement. (1) top priorities(high importance and low performance) (in this study)- more health-related information -accuracy in billing - quality of food - appointments at my convenience - information about tests and treatments - prompt service of business office -adequacy of accommodations(elevators, etc) (2) current strengths(high importance and high performance) (3)unnecessary strengths(low importance and high performance) (4) low priorities(low importance and low performance) While 26 service quality attributes of SERPERF model were significantly related to patient satisfation, only 13 attributes of SERVQUAL model were significantly related. This result suggested that only experience-based norms(SERVPERF model) were more appropriate than expectations to serve as a benchmark against which service experiences were compared(SERVQUAL model). However, it must be noted that the degree of association to overall satisfaction was not consistent. There were some gaps between nurse percetions and patient perception of medical service performance. From the patient's viewpoint, "personal likability", "technical skill/trust", and "cares about me" were most significant positioning factors that contributed patient satisfaction. DISCUSSION This study shows that there are inconsistencies between nurse perceptions and patient perceptions of medical service attributes. Also, for service quality improvement, it is most important for nurses to understand what satisfiers, hygiene factors, and performance factors are through two-way communications. Patient satisfaction should be measured, and problems identified should be resolved for survival in intense competitive market conditions. Hence, patient satisfaction monitoring is now becoming a standard marketing tool for healthcare providers and its role is expected to increase.

  • PDF

THE BEST TEETH COMBINATION TO PREDICT MESIODISTAL DIAMETERS OF THE UNERUPTED CANINE AND PREMOLARS OF KOREANS (한국인에서 미맹출 견치와 소구치의 근원심 폭경 예측을 위한 최적의 치아조합)

  • Kim, So-Hwa;Kim, Seong-Oh;Choi, Hyung-Jun;Choi, Byung-Jai;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.430-437
    • /
    • 2007
  • The probability table of Moyers and prediction equation of Tanaka and Johnston that have been the most frequently used, cannot produce accurate prediction when used in Korean because they are based on the Caucasian popularity of the Northern European race. The method of Moyers or Tanaka and Johnston predicts sizes of the unerupted canine and premolars on the basis of the sizes of mandibular incisors. However, some of the recent papers raise a question as to whether the mandibular incisors are the best combination to predict the sizes of the unerupted canine and premolars. The purpose of this study is to determine which sum or combination of sums of permanent tooth widths present the best prediction for the unerupted canine and premolars in a Korean sample, to calculate a specific linear regression equation for this population, and to evaluate the clinical significance. A new linear regression equation was calculated based on the data of 178 Korean young adults(70 women, 108 men, mean age 21.63 years) with complete permanent dentitions. Fifty three more children(28 girls, 25 boys, mean age 14.22 years) were used as a validation sample for the application of the multiple linear regression equation. The conclusions were as follows: 1. The combination of the sums of permanent upper central incisors, lower lateral incisors and upper first molars was the best predictor for the unerupted canine and premolars in this sample($r=0.65{\sim}0.80$). 2. The multiple linear regression equation was calculated including sex and arch as additional predictor variables. male, upper: $Y\;=\;0.332{\times}X_0\;+\;6.195$ male, lower: $Y\;=\;0.332{\times}X_0\;+\;5.269$ female, upper: $Y\;=\;0.332{\times}X_0\;+\;5.929$ female, lower: $Y\;=\;0.332{\times}X_0\;+\;5.003$. The determination coefficient of the equation was 64% and a standard error of the estimate was 0.71mm. 3. In about 97% of the validation sample, the estimation of the tooth width sums of unerupted canine and premolars using the new multiple linear regression equation was smaller than 1mm compaired with the actual values.

  • PDF

The Determinants of Health Promoting Behavior of Industrial Workers (산업장 근로자의 건강증진행위와 자아개념 및 건강의 중요성 인식에 관한 연구)

  • Kim, Chung Nam
    • Korean Journal of Occupational Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.5-19
    • /
    • 1998
  • This descriptive-correlational study was conducted to identify the major factors affecting health promoting behaviors. 344 workers who employed in four different manutacturing plants in Taegu and Kyungbuk area were selected by convenience sampling method. Data were collected from April let to April 18th, 1998 by ready structured questionaires. The purpose of this study was to offer the basic data for health promotion theory development and health promotion strategy planning. This study was based on Pender's Health Promotion Model and examined three variables health promoting behavior, self-concept and perceived importance of health. The Life Style and Health Habit Assessment scale(LHHA) developed by Pender(1982).The Self-concept scale developed by Choi(1972) and the Health Value scale developed by Wallston, Maides and Wallston(1980) were used for this study. Data was analyzed by percentage, mean. t-test. ANOVA, Pearson Correlation Coefficient, and Stepwise Multiple Regression. The major findings of this study are as follows ; 1. The average level of health promoting behavior practice was 63.2% and possible range was from 62 to 248 point. The mean score of respondent's positive self-concept was 75.8. 81.4% of respondents put a high priority on the importance of health. 2. There was a significant difference between the practice level in the category of general self care and less amount of working hours per day(P=0.000), less amount of working hours per week(P=0.000). There was a significant difference between the practice level in the category of nutrition and age(0.002), marital status(0.000), working hour per day(0.008), working hours per week(0.001), There was a significant difference between the practice level in the category of nutriton and sex(0.000), age(0.000), marital status(0.025), education level(0.000), working hours per day(0.002), working hours per week(0.006). There was a significant difference between the practice level in the category of sleep and rest and age(0.003), marital status(0.002), working hours per day(0.001), working hours per week(0.001). There was a significant difference between the practice level in the category of stress management and working hours per day(0.001), working hours per week(0.002). There was a significant difference between the practice level in the category of self-actualization and working hours per day(0.050). 3. General characteristics influencing the respodent's self-concept were level(P=0.009) and worksite(P=0.001). 4. The results of the hypothesis tests are as follows The first hypothesis, that "The respondent who have more positive self-concept will have higher scores in the practice of health promoting behavior." was supported(r=0.2973, P=0.0001). The second hypothesis that "The respondent who have higher perception level on importance of health will have higher scores in the practice health promoting behavior." was rejected(r=- 0665, P=0.2225). 5. The most important factor that affects health promoting behavior practice was working hours per week(6.0%). The combination of working hours per week, age, education level accounted for 10.0% of the variance in health promoting behavior. In conclusion, the results of this study on industrial workers supported Pender's health promotion model in partial and showed the relatedness between self concept and the practice of health promoting behavior. Further research is required to find factors influencing health promoting behaviors of industrial workers.

  • PDF

Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering (3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Rhim, Jae-Dong;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.208-215
    • /
    • 2009
  • This study is to compare the accuracy of evaluation regarding the volume of the prostate, which three-dimensional volume rendering was produced the shape of protrusion, by measuring two kinds of craniocaudal length from the top of the protrusion and from the exclusion of the protrusion as the starting points. For the imaginary protrusion prostate models, total of 10 models were roughly made by using devils-tongue jelly and changing each of the 10 ml of capacity from 10 ml to 100 ml. For the protrusion prostate models aimed at estimating the real volume, through 64 cannel computed tomography (CT) and 3.0 tesla magnetic resonance image (MRI) were conducted by planimetry technique from three-dimensional volume rendering. And then we performed to evaluate on significance of these volumes by wilcoxon signed rank test. Also the obtained volumes data by ellipsoid volume formula were measured the volume of protrusion prostate models two times with each method using the two kinds of craniocaudal length from top of the protrusion and from exclusion of the protrusion as the starting points. Finally, the significance of differences using wilcoxon signed rank test was evaluated between the real volume by planimetry technique and the measured volume by ellipsoid volume formula from three-dimensional volume rendering. The average of the protrusion length on the models was $0.90{\pm}0.18\;mm$ in CT and was $0.75{\pm}0.11\;mm$ in MRI. There were not statistically significant difference between MRI and CT from the volume of protrusion prostate models (p=0.414). In MRI (p=0.139) and CT (p=0.057), there were not statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from exclusion of the protrusion as the starting points. While, there were statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from top of the protrusion as the starting points in MRI (p=0.005) and CT (p=0.005). For the accurate measurement of the protrusion prostate models, the craniocaudal length of the prostate should be measured from the exclusion of the protrusion as the starting points.

  • PDF

The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI (뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교)

  • Kim, Tae;Choe, Bo-Young;Kim, Euy-Neyng;Suh, Tae-Suk;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Purpose : The purpose of this study was to find the optimum TE value for enhancing $T_2^{*}$ weighting effect and minimizing the SNR degradation and to compare the BOLD effects according to the changes of TE in 1.5T and 3.0T MRI systems. Materials and Methods : Healthy normal volunteers (eight males and two females with 24-38 years old) participated in this study. Each volunteer was asked to perform a simple finger-tapping task (sequential opposition of thumb to each of the other four fingers) with right hand with a mean frequency of about 2Hz. The stimulus was initially off for 3 images and was then alternatively switched on and off for 2 cycles of 6 images. Images were acquired on the 1.5T and 3.0T MRI with the FLASH (fast low angle shot) pulse sequence (TR : 100ms, FA : $20^{\circ}$, FOV : 230mm) that was used with 26, 36, 46, 56, 66, 76ms of TE times in 1.5T and 16, 26, 36, 46, 56, 66ms of TE in 3.0T MRI system. After the completion of scan, MR images were transferred into a PC and processed with a home-made analysis program based on the correlation coefficient method with the threshold value of 0.45. To search for the optimum TE value in fMRI, the difference between the activation and the rest by the susceptibility change for each TE was used in 1.5T and 3.0T respectively. In addition, the functional $T_2^{*}$ map was calculated to quantify susceptibility change. Results : The calculated optimum TE for fMRI was $61.89{\pm}2.68$ at 1.5T and $47.64{\pm}13.34$ at 3.0T. The maximum percentage of signal intensity change due to the susceptibility effect inactivation region was 3.36% at TE 66ms in 1.5T 10.05% at TE 46ms in 3.0T, respectively. The signal intensity change of 3.0T was about 3 times bigger than of 1.5T. The calculated optimum TE value was consistent with TE values which were obtained from the maximum signal change for each TE. Conclusion : In this study, the 3.0T MRI was clearly more sensitive, about three times bigger than the 1.5T in detecting the susceptibility due to the deoxyhemoglobin level change in the functional MR imaging. So the 3.0T fMRI I ore useful than 1.5T.

  • PDF

Studies on Simultaneous Determination of Chlorophyll a and b, Pheophorbide a, and $\beta-Carotene$ in Chlorella and Spirulina Products (클로렐라 및 스피루리나제품에 함유된 엽록소 a, b, 페오포르바이드 a 및 $\beta$-카로틴의 동시분석법에 관한 연구)

  • Lee Young Ja;Kim So Hee;Kim Jin-Sook;Han Jeong A;Seo Hae Jeom;Lim Hyo Jeong;Choi Soo Young
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.3
    • /
    • pp.141-146
    • /
    • 2005
  • A simple and sensitive analysis method based on reverse phase (RP) HPLC with UV detector was developed for simultaneous determination of chlorophyll a and b, pheophorbide a and $\beta-Carotene$ in Chlorella and Spirulina products. For added concentration $(50\;\mug/ml)$ of chlorophyll a and b, pheophorbide a and $\beta-Carotene$, recoveries of those were 70.3, 71.6, 60.1 and $90.5\%$, respectively, with relative standard deviations of 2.8,6.0, 10.6 and $10.4\%$. Limit of detection and quantification had ranges of $0.1\sim1.0\;\mug/ml$ and $0.2\sim2.0\;\mug/ml$, respectively. Calibration curve was linear with correlation coefficient of 0.995 for chlorophyll a and b, pheophorbide a and $\beta-Carotene$. Results of simultaneous determination in Chlorella and Spirulina products were showed ranges of $121.g\sim543.0\;\mug/ml$ for chlorophyll a,$0.6\sim160.0\;\mug/ml$ for chlorophyll b, $19.2\sim60.3\;\mug/ml$ for pheophorbide a and $383.6\sim1713.7\;\mug/ml$ for $\beta-Carotene$, respectively. Chlorophyll b contents in Chlorella products were detected above 30 times level to those in Spirulina products. $\beta-Carotene$ contents in Spirulina products were detected 2.7 times level to those in Chlorella products.

Correlation of Effective Dose and BMI in Radioiodine($^{131}I$) Therapy (방사성옥소($^{131}I$) 치료 시 유효선량과 체질량지수의 상관관계)

  • Shin, Gyoo-Seul;Kim, Gun-Jae;Dong, Kyung-Rae;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Purpose : The aim of this study was to predict radiation dose at 1 meter with BMI(body mass index) in thyroid cancer patients treated with radio-iodine and provide the efficient guideline in the management of patients. Methods : 140 patients from thyroidectomy for thyroid cancer were enrolled. All subjects under went 150 mCi radio-iodine therapy and performed whole body scan 1 week later. BMI(weight divided by square of height) was calculated to evaluate the amount of fatty tissue indirectly. The radiation dose at 1 meter was measured initially and on 2nd days. the relation of values with BMI were analyzed statically. As for the method of statistical analysis, using Med calc Version 9,2,2,0 Program. Results : (1) The initial effective dose was inversely correlated with the BMI. Significance level was 0.0004. (2) We obtained the following formula from the data of initial effective dose and BMI: Y = -30.91X + 350.4(${\mu}Sv/h$)(Y: initial radiation dose, x: Group). (3) After 21.55 hours, than radiation dose was less than those recommended by ICRP or NRC in 53% of the population. Conclusion : Using BMI, the initial radiation dose and 2nd days dose can be predicted in thyroid cancer patients before radio-iodine therapy. It may be used for predicting the time of discharge and control the isolation room. We were able to predict the radiation exposure after discharge using this calculated value.

  • PDF

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF