• Title/Summary/Keyword: Code Coverage

Search Result 103, Processing Time 0.025 seconds

Design Methodology of System-Level Simulators for Wideband CDMA Cellular Standards (광대역 CDMA 셀룰러 표준을 위한 시스템 수준 시뮬레이터의 설계 방법론)

  • Park, Sungkyung
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.1
    • /
    • pp.41-51
    • /
    • 2013
  • This tutorial paper presents the design methodology of system-level simulators targeted for code division multiple access (CDMA) cellular standards such as EV-DO (Evolution-Data Only) and broadcast multicast service (BCMCS). The basic structure and simulation flow of system-level simulators are delineated, following the procedure of cell layout, mobile drops, channel modeling, received power calculation, scheduling, packet error prediction, and traffic generation. Packet data transmissions on the forward link of CDMA systems and EV-DO BCMCS systems are considered for modeling simulators. System-level simulators for cellular standards are modeled and developed with high-level languages and utilized to evaluate and predict air interface performance metrics including capacity and coverage.

Experimental Evaluation on Effective Moment of Inertia of Reinforced Concrete Simple Beams and Continuos Beams Considering Tension Stiffening Effect (인장증강효과를 고려한 철근콘크리트 단순보와 연속보의 유효 단면2차모멘트에 대한 실험적 검증)

  • Lee, Seung-Bae;Yoon, Hyeong-Jae;Kim, Kang-Su;Kim, Sang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.285-288
    • /
    • 2008
  • A model for the effective moment of inertia $I_{\epsilon}$ as expressed in Branson's equation, in which reduction of the flexural rigidity of RC beams due to cracking are aptly taken into accoun,t is presented. However, KCI Code isn`t considered tension stiffening as it is in debonding of reinforcing bar. Therefore, this equation need to set up suitable to our design Code. The experimental work consisted of casting and testing a total of 6 simply supported reinforced concrete beams and a total of 4 continuos reinforced concrete beams under two point concentrated loads. Main parameters are concrete strength, coverage, bond between concrete and reinforcing bars, are known as have an effect on deflection and tension stiffening. Every test beams had the same $250{\times}350$mm rectangular section, with a simply supported clear span of 4,400 mm and a continuos clear span of 6,500 mm. Comparison of the test results with values obtained using the KCI Code equation of the effective moment of inertia showed a noticeable difference.

  • PDF

A Study on the Efficiency of Evacuation Exterior Stairs in High-rise Buildings (고층빌딩에서 옥외피난계단의 효용성에 관한 연구)

  • Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • Article 36 of the Building Code Enforcement Ordinance requires that an exterior evacuation stairs be installed for the buildings of three stories and over with cultural facilities or gathering places which have over $1,000\;m^2$ floor area of public performance halls or recreational facilities. The concentration of population together with the increase of high-rise buildings in cities call for various precautionary measures to be taken against human disasters. For the past ten years high-rise buildings showed 85% of increase, marking a steep rise. This increase of high-rise buildings may lead to human disasters in urban areas and, in case of fire breakout, may cause great loss of human lives and property damages. The most difficult fire-fighting activities in high-rise building fires are those of evacuation. Because smoke spreads through the upper floors, the securement of evacuation route in high-rise buildings may be the only way to minimize loss of lives. In high-rise buildings exterior escape stairs are necessary because it is difficult to secure evacuation route with only direct stairs or interior stairs. The Building Code now in force provides insignificant coverage on the exterior evacuation route installment and therefore becomes an inadequate means for evacuation route securement in high-rise building fires. To compensate for this inadequacy the Building Code should be revised to include a mandatory clause that an exterior evacuation stairs be established for the buildings of ten stories and over which can be categorized into high-rise building group.

A Study on Validation for Mapping of Gas Detectors at a BTX Plant (BTX 공정에서 Gas Detector Mapping 적정성 검토에 관한 연구)

  • Seo, Ji Hye;Han, Man Hyoeng;Kim, Il Kwon;Chon, Young Woo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.168-178
    • /
    • 2017
  • In order to prevent major and chemical accidents, some of the plants which would like to install and operate hazard chemicals handling facilities must submit Off-site Consequence Analysis due to recent arisen leak accidents since 2015. A lot of chemical industrials choose gas detectors as mitigation equipment to early detect gas vapor. The way of placement of gas detectors has two methods; Code-based Design(CBD) and Performance-based Design. The CBD has principles for gas detectors to be installed with consideration for the place that is expected to accumulate gas, and the leak locations according to legal standards and technical guidelines, and has a possibility to be unable to detect by these rules to locate gas detectors by vapor density information. The PBD has two methods; a Geographic Method and Scenario based Method. The Scenario-based Method has been suggested to make up for the Geographic Coverage Method. This Scenario-based Method draw the best optimum placement of gas detectors by considering leak locations, leak speed information, leak directions and etc. However, the domestic placement guidelines just refers to the CBD. Therefore, this study is to compare existing placement location of gas detectors by the domestic CBD with placement locations, coverages and the number of gas detectors in accordance with the Scenario-based Method. Also this study has measures for early detecting interest of Vapor Cloud and suitable placement of gas detectors to prevent chemical accidents. The Phast software was selected to simulate vapor cloud dispersion to predict the consequence. There are two cases; an accident hole size of leak(8 mm) from API which is the highst accident hole size less than 24.5 mm, and a normal leak hole size from KOSHA Guide (1.8 mm). Detect3D was also selected to locate gas detectors efficiently and compare CBD results and PBD results. Currently, domestic methods of gas detectors do not consider any risk, but just depend on domestic code methods which lead to placement of gas detectors not to make personnels recognize tolerable or intolerable risks. The results of the Scenario-based Method, however, analyze the leak estimated range by simulating leak dispersion, and then it is able to tell tolerable risks. Thus it is considered that individuals will be able to place gas detectors reasonably by making objectives and roles flexibly according to situations in a specific plant.

Feasibility Study on Integration of SSR Correction into Network RTK to Provide More Robust Service

  • Lim, Cheol-Soon;Park, Byungwoon;Kim, Dong-Uk;Kee, Chang-Don;Park, Kwan-Dong;Seo, Seungwoo;So, Hyoungmin;Park, Junpyo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.4
    • /
    • pp.295-305
    • /
    • 2018
  • Network RTK is a highly practical technology that can provide high positioning accuracy at levels between cm~dm regardless of user location in the network by extending the available range of RTK using reference station network. In particular, unlike other carrier-based positioning techniques such as PPP, users are able to acquire high-accuracy positions within a short initialization time of a few or tens of seconds, which increases its value as a future navigation system. However, corrections must be continuously received to maintain a high level of positioning accuracy, and when a time delay of more than 30 seconds occurs, the accuracy may be reduced to the code-based positioning level of meters. In case of SSR, which is currently in the process of standardization for PPP service, the corrections by each error source are transmitted in different transmission intervals, and the rate of change of each correction is transmitted together to compensate the time delay. Using these features of SSR correction is expected to reduce the performance degradation even if users do not receive the network RTK corrections for more than 30 seconds. In this paper, the simulation data were generated from 5 domestic reference stations in Gunwi, Yeongdoek, Daegu, Gimcheon, and Yecheon, and the network RTK and SSR corrections were generated for the corresponding data and applied to the simulation data from Cheongsong reference station, assumed as the user. As a result of the experiment assuming 30 seconds of missing data, the positioning performance compensating for time delay by SSR was analyzed to be horizontal RMS (about 5 cm) and vertical RMS (about 8 cm), and the 95% error was 8.7 cm horizontal and 1cm vertical. This is a significant amount when compared to the horizontal and vertical RMS of 0.3 cm and 0.6 cm, respectively, for Network RTK without time delay for the same data, but is considerably smaller compared to the 0.5 ~ 1 m accuracy level of DGPS or SBAS. Therefore, maintaining Network RTK mode using SSR rather than switching to code-based DGPS or SBAS mode due to failure to receive the network RTK corrections for 30 seconds is considered to be favorable in terms of maintaining position accuracy and recovering performance by quickly resolving the integer ambiguity when the communication channel is recovered.

Design and Performance of Low Complexity Multiple Antenna Relay Transmission Based on STBC-OFDM (시공간 부호화 직교 주파수분할 다중화 기반 저 복잡도 다중 안테나 릴레이 전송 방식 설계 및 성능)

  • Lee, Ji-Hye;Park, Jae-Cheol;Wang, Jin-Soo;Lee, Seong-Ro;Kim, Yun-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.11C
    • /
    • pp.673-681
    • /
    • 2011
  • In this paper, we design multiple antenna relay transmission schemes of low complexity to enhance the spatial diversity in orthogonal frequency division multiplexing (OFDM) systems. The relay scheme underlined, can provide space time block coding (STBC) of OFDM signals in the time domain without IFFT and FFT operations with much reduced complexity. In this paper, we modify the conventional low-complexity STBC-OFDM relaying scheme to be compatible to the existing OFDM systems. In addition, we extend the proposed scheme for multiple antenna relays and provide performance enhancement strategies according to the channel quality information available at the relay. The proposed scheme is shown to improve the diversity and thereby to reduce the outage probability and coded bit error rate. Therefore, the proposed scheme will be promising for service quality improvement or coverage extension based on OFDM like wireless LANs and maritime communications.

Performance Evaluation of a Pilot Interference Cancellation Scheme in a WCDMA Wireless Repeater (WCDMA 무선 중계기에서 파일럿 간섭제거 기법의 성능평가)

  • Kim, Sun-Ho;Shim, Hee-Sung;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.6
    • /
    • pp.111-117
    • /
    • 2009
  • In the wideband code division access (WCDMA) systems, a pilot channel is used to determine WCDMA network coverage, cell identification, synchronization, timing acquisition and tracking, user-set handoff, channel estimation, and so on. A wireless repeater, which is deployed in the urban area for the WCDMA system to meet the growing demand on wireless communication services, has the possibility to receive several pilot signals from a large number of base stations, however, cannot distinguish its service base station's signal among them. This pilot interference results in frequent handoffs in the user equipment, which degrades the radio reception, transmission efficiency, quality of service, and channel capacity and increases the unwanted power consumption. In this paper, thus, we propose a pilot pollution interference cancellation scheme using one of the adaptive estimation algorithms, normalized least mean square (NLMS), which is applicable to a wireless repeater. We carried out link-level and network-level computer simulations to evaluate the performance of the proposed scheme in a wireless repeater. The simulation results verify the bit error rate (BER) improvement in the link level and the call drop probability improvement in the network level.

A Study on Development of Village Wetlands Inventory Using GIS and Establishment of Management Methods in Asan City, Korea (GIS를 이용한 아산시 마을습지 인벤토리 구축 및 관리 방안 연구)

  • Park, Mi Ok;Yang, Seung Bin;Koo, Bon Hak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.6
    • /
    • pp.167-177
    • /
    • 2015
  • This study was conducted to establish an inventory and propose conservation strategies for 'village wetlands' in Asan city, Korea, using GIS. As results, the village wetlands are defined as such places as 'palustrine' wetland, village embankment, agricultural reservoir or small reservoirs located in or near the village and related to everyday life or farming. Firstly 807 provisional village wetlands(draft) were identified in Asan by using Arc-GIS 10.1, then 196 wetlands(final) were defined finally as village wetlands and listed the inventory of Asan Village Wetlands after being validated through office works and field survey. The office works analyzed minimum area(greater than $625m^2$), satellite images, the Korea Land Information System, land use map and land coverage map. To evaluate the function and conservation values, the 37 wetlands were selected for detailed surveying and function assessment based on the following criteria : 1) doubled code both wetland and reservoir at digital map, 2) located less than 100m from village and 3) ecologically connected to such ecological resources as seaside mudflats, mountains and green area and ecological passages for small size wildlifes. As the result of the wetland function assessments by the RAM method, 7 wetlands were found to have 'high' wetland function (conservation) 18 wetlands were 'medium' (enhancement) and 12 wetlands were 'low' (restoration or enhancement). Enhancing biodiversity and ecosystem services through ecological management of wetlands in Asan and connecting with the Ecological Natural Degree were proposed.

NEP-AKARI: EVOLUTION WITH REDSHIFT OF DUST ATTENUATION IN 8 ㎛ SELECTED GALAXIES

  • Buat, V.;Oi, N.;Burgarella, D.;Malek, K.;Matsuhara, H.;Murata, K.;Serjeant, S.;Takeuchi, T.T.;Malkan, M.;Pearson, C.;Wada, T.
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.257-261
    • /
    • 2017
  • We built a $8{\mu}m$ selected sample of galaxies in the NEP-AKARI field by defining 4 redshift bins with the four AKARI bands at 11, 15, 18 and 24 microns (0.15 < z < 0.49, 0.75 < z < 1.34, 1.34 < z < 1.7 and 1.7 < z < 2.05). Our sample contains 4079 sources, 599 are securely detected with Herschel/PACS. Also adding ultraviolet (UV) data from GALEX, we fit the spectral energy distributions using the physically motivated code CIGALE to extract the star formation rate, stellar mass, dust attenuation and the AGN contribution to the total infrared luminosity ($L_{IR}$). We discuss the impact of the adopted attenuation curve and that of the wavelength coverage to estimate these physical parameters. We focus on galaxies with a luminosity close the characteristic $L^*_{IR}$ in the different redshift bins to study the evolution with redshift of the dust attenuation in these galaxies.

Development of Human Indices to Determine Both Returning Point of Residents and Damage Restoration after the Chemical Accident (화학사고 후 주민복귀 및 피해복구 시점 결정을 위한 인체지표 개발)

  • Yang, JunYong;Heo, JeongMoo;Lee, HyunSeok;Lee, JunSang;Cho, YongSung;Kim, HoHyun;Park, SangHee
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.588-598
    • /
    • 2020
  • Objectives: Human indices were developed to determine returning point of residents and damage restoration after the chemical accident Methods: To determine the returning point of residents after the chemical accident, a new concept, the standard man model was introduced as a human index, in which both H-code and its acute effects were main idea. To evaluate the applicability, a hydrogen fluoride leakage accident in Gumi was applied. The returning point were suggested as the conservative remission period of acute effects among relevant hazard effects and compared with actual returning point. The coverage of each age group were considered with reflecting average daily dose expected for actual residents. In addition, a relief-index as a social-scientific approach was reflected as well to apply the damage restoration Results: Actual returning point of residents in Gumi was 88 days; and that of standard man model suggested was 84 days. The expected amount of exposure at aged 12 or under was at least 2.35 times greater than that of this model, 40s, theoretically. However, their population ratio was less than 1%, so 99% of residents could be applied when the standard man model was applied. The relief-index was as an objective and quantitative methodology to apply the qualitative aspect. Conclusions: Although evaluated as a relatively positive result, there was a limitation such as the number of accident applied to the verification of standard man model. The relief index was also considered, but further research should be carried out to find threshold level for the relief.