• Title/Summary/Keyword: Coal dust

Search Result 142, Processing Time 0.027 seconds

Size-segregated Sources of Aerosol Estimated by Factor Analysis-For the Measurement using Drum Impactor at Gosan, Jeju Island in May 2002 (인자분석을 통한 대기 입자상 물질의 입경별 발생원 추정-Drum impactor를 이용한 2002년 5월 제주도 고산지역 측정을 중심으로)

  • Han, J.S.;Moon, K.J.;Kong, B.J.;Ryu, S.Y.;Kim, Y.J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.685-695
    • /
    • 2004
  • Size-segregated measurements of aerosol composition are used to estimate the transport of natural and anthropogenic aerosols at Gosan site during May 2002. The results of measurement show that not only soil dust but also anthropogenic aerosols, including sulfur and enriched trace metals such as Pb, Zn, Cu, are transported to Gosan. This study combines the size- and time-resolved aerosol composition measurements with factor analysis in order to identify some source materials. As a result, coarse particles (2.5${\mu}m$~12${\mu}m$) are influenced by soil, sea-salt, coal, coal combustion, and nonferrous sources. But fine particles have different sources. The fine particles, which the diameter is from 0.56${\mu}m$ to 2.5${\mu}m$, are more affected by road dust, oil combustion, industry. municipal incineration, and ferrous metal sources. The very fine particles, from 0.09${\mu}m$ to 0.56${\mu}m$, mainly supplied by biomass burning, oil combustion, nonferrous and ferrous metal sources.

Comparison of Mutagenic Activities of Various Ultra-Fine Particles

  • Park, Chang Gyun;Cho, Hyun Ki;Shin, Han Jae;Park, Ki Hong;Lim, Heung Bin
    • Toxicological Research
    • /
    • v.34 no.2
    • /
    • pp.163-172
    • /
    • 2018
  • Air pollution is increasing, along with consumption of fossil fuels such as coal and diesel gas. Air pollutants are known to be a major cause of respiratory-related illness and death, however, there are few reports on the genotoxic characterization of diverse air pollutants in Korea. In this study, we investigated the mutagenic activity of various particles such as diesel exhaust particles (DEP), combustion of rice straw (RSC), pine stem (PSC), and coal (CC), tunnel dust (TD), and road side dust (RD). Ultra-fine particles (UFPs) were collected by the glass fiber filter pad. Then, we performed a chemical analysis to see each of the component features of each particulate matter. The mutagenicity of various UFPs was determined by the Ames test with four Salmonella typhimurium strains with or without metabolic activation. The optimal concentrations of UFPs were selected based on result of a concentration decision test. Moreover, in order to compare relative mutagenicity among UFPs, we selected and tested DEP as mutation reference. DEP, RSC, and PSC induced concentration-dependent increases in revertant colony numbers with TA98, TA100, and TA1537 strains in the absence and presence of metabolic activation. DEP showed the highest specific activity among the particulate matters. In this study, we conclude that DEP, RSC, PSC, and TD displayed varying degrees of mutagenicity, and these results suggest that the mutagenicity of these air pollutants is associated with the presence of polycyclic aromatic hydrocarbons (PAHs) in these particulate matters.

A Study on the Development of Source Profiles for Fine Particles (PM2.5) (미세입자(PM2.5)의 배출원 구성물질 성분비 개발에 관한 연구)

  • 이학성;강충민;강병욱;이상권
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.317-330
    • /
    • 2004
  • The Purpose of this study was to develop the P $M_{2.5}$ source Profiles, which are mass abundances (fraction of total mass) of a chemical species in P $M_{2.5}$ source emissions. The source categories studied were soil, road dust, gasoline and diesel vehicles, industrial source, municipal incinerator, coal-fired power plant, biomass burning, and marine. The chemicals analyzed were ions. elements. and carbons. From this study, soil source had the crustal components such as Si, hi, and Fe. In the case of road dust. Si, OC, Ca, Fe had large abundances. The abundant species were S $O_4$$^{2-}$, C $l^{[-10]}$ , N $H_4$$^{+}$, and EC in the gasoline vehicle and EC, OC, C $l^{[-10]}$ , and S $O_4$$^{2-}$ in the diesel vehicle. The main components were S $O_4$$^{2-}$, S N $H_4$$^{+}$, and EC in the industrial source using bunker C oil as fuel, C $l^{[-10]}$ , N $H_4$$^{+}$, Fe, and OC in the municipal incinerator source, and Si, Al, S $O_4$$^{2-}$, and OC in the coal -fired power plant source. In the case of biomass burning, OC, EC, and C $l^{[-10]}$ were mainly emitted. The main components in marine were C $l^{[-10]}$ , N $a^{+}$, and S $O_4$$^{2-}$.EX> 2-/.

Study on Explosion Characteristics and Thermal Stability of Activated Carbon (활성탄의 폭발특성과 열안정성에 관한 연구)

  • Yi-Rac Choi;Dong-Hyun Seo;Ou-Sup Han;Hyo-Geun Cha
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.134-140
    • /
    • 2023
  • Activated carbon is a carbonaceous material mainly used as a gaseous or liquid adsorbent. As fire-related accidents occur consistently due to the accumulation of heat of adsorption and oxidation of volatile organic compounds, the explosive characteristics and thermal stability of powdered and granular activated carbon made from coal and coconut shells were evaluated. As a result of the particle size analysis, the powdered activated carbon was in the particle size range (0.4~3) ㎛, and thermal properties such as exothermic onset temperature and decomposition behavior were analyzed using a differential scanning calorimetry and a thermogravimetric analysis. As a result of the evaluation of the explosion hazards for dust, both coal-based and coconut-based powdered activated carbon are classified as St1 class with weak explosion, but this is a relative and does not mean that the explosion hazards is absolutely low. Therefore, it is necessary to establish countermeasures for reducing the damage.

Planting Structure and Ecological Characteristics of Green Spaces at the Dangjin Steam Power Plant (당진화력발전소 녹지공간의 식재현황 및 생태적 특성 분석)

  • Kang Hyun-Kyung;Lee Soo-Dong;Han Bong-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.78-89
    • /
    • 2006
  • This study was conducted to analyze the planting structure and ecological characteristics of greon spaces on the grounds of e Dangjin steam power plant. To achieve these goals, we surveyed existing vegetation, plant community structure, Plant volume and growth rate. Based on e vegetation analysis, existing vegetation was classified into six types: herbaceous species $(70.54\%)$, evergreen coniferous trees $(21.17\%)$, deciduous broad-leaved trees $(5.10\%)$, deciduous coniferous trees $(1.47\%)$, shrubs $(0.12\%)$, and other types $(1.59\%)$. The coal storage, office, and playground areas were community is the natural forest area where a Pinus thunbergii / Pinus densiflora community is distributed in terms of vegetation structure, species diversity, plant volume, and growth rate. The artificial green spaces(near the coal storage, office, playground areas) had a single-layer structure. Species diversity indices of the artificial green areas were $0.1655\~0.4807$ compared to 0.8628 in the natural forest, which presented a good growth environment. Also, the plant volume in the artificial green space was lower than that of the natural green space. Therefore, it would be desirable to develope a multi-layer structure similar to that of the vegetation in the natural green space in order to improve the amount of plant volume. The plant-damage ratio of Pinus thunbergii was $52.48\%$ in the coal storage area, and $8.48\~ 11.52\%$, in the other survey areas. Also, the vitality of Pinus thunbergii was $15.45k{\Omega}$ in the coal storage areas, which indicates bad growing conditions. This suggests that soil characteristics and dust have a bad impact on growth. The investigation into deciduous tres' growth status showed that appropriate plants would be Albizzia julibrissin, Acer palmatum var. sanguineum, Acer palmatum, Malus spp., Prunus sargentii.

Serum Levels of Interleukin-8 and Tumor Necrosis Factor-alpha in Coal Workers' Pneumoconiosis: One-year Follow-up Study

  • Lee, Jong-Seong;Shin, Jae-Hoon;Lee, Joung-Oh;Lee, Kyung-Myung;Kim, Ji-Hong;Choi, Byung-Soon
    • Safety and Health at Work
    • /
    • v.1 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • Objectives: Various cytokines induced by inhalation of coal dust may mediate inflammation and lead to tissue damage or fibrosis, such as coal workers' pneumoconiosis (CWP). Methods: To investigate the relevance of serum cytokines in CWP, the levels of serum interleukin-8 (IL-8) and tumor necrosis factor-alpha (TNF-${\alpha}$) as CWP biomarkers in 110 retired coal miners (22 controls and 88 CWP subjects) were related to cross sectional findings and 1-year progressive changes of the pneumoconiosis. Progressive changes of CWP were evaluated by paired comparison of chest radiographs. Analysis by a receiver operating characteristic curve assessed the biomarker potential of each cytokine. Results: The mean serum IL-8 level was significantly higher in CWP compared to controls and IL-8 levels correlated with the degree of CWP. The median serum TNF-${\alpha}$ level was significantly higher in subjects with progressive CWP compared to subjects without CWP progression. The area under the ROC curve for IL-8 (0.70) and TNF-${\alpha}$ (0.72) for CWP identification and progression, respectively, indicated the biomarker potential of the two cytokines. Serum cutoff values of IL-8 and TNF-${\alpha}$ were 11.63 pg/mL(sensitivity, 69%; specificity, 64%) and 4.52 pg/mL (sensitivity, 67%; specificity, 79%), respectively. Conclusion: The results suggest that high levels of serum IL-8 are associated with the presence of CWP and those of serum TNF-${\alpha}$ are associated with the progression of CWP.

A Study on the Power Generation Compared to the Capacity of Power Generation Facilities by Energy Sources in Summer Season (하절기의 에너지원별 발전설비용량 대비 발전량에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.36-40
    • /
    • 2019
  • In this study, we compared the operational rates of natural gas, coal, nuclear power and renewable energy based on the data of power generation and power generation facilities produced in summer season(from June to August) during the last four years(2015~2018). Nuclear power and coal power, which are responsible for basic power generation, were guaranteed to be economical as the actual generation capacity remained 60% higher than the cost of power generation. On the other hand, natural gas generation and new renewable energy generation have a very low actual operation rate of 29.5% and 27.3% compared to investments in power generation facilities, making it difficult to lower the cost of power generation. However, coal generation has structural problems in terms of greenhouse gas, fine dust. On the other hand, natural gas generation is relatively low and even though it is safe, it is difficult to secure economic feasibility as it is bound by a peak power system. Therefore, it is only possible to achieve balanced development of energy sources when there is a change in the development policy.

A Study on Properties of Domestic Fly Ash and Utilization as an Insulation material (국산 Fly Ash의 특성 및 단열재로의 이용에 관한 연구)

  • 박금철;임태영
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.2
    • /
    • pp.135-146
    • /
    • 1983
  • This study is to investigate the properties of domestic fly ash for utilization as data in regard to fly ash which is by-product of domestic coal powder plants and the possibility of utilization as insulation material of domestic fly ash. Composition refractoriness size distribution density contents of hollow particles and crystalline phase were examined as the properties of domestic fly ash. As to the fired test pieces of fly ash by itself that varied contents of hollow particles with four kinds and of the fly ash-clay-saw dust system linear shrinkage bulk density app. porosity compressive strength thermal conductivity and structures were investigated for the possibility of utilization as an insulation material. The results are as follows : 1. The properties of the fly ash I) The constituent particle of the fly ash is spherical and it contains not a few hollow particles (floats by water 0.30-0.50 floats by $ZnCl_2$ aq.(SpG=1.71) 6.97-16.72%). ii) The chemical compositions of fly ash are $SiO_243.9-54.1%$ , $Al_2O_321.0-30.7%$ Ig loss is 7.4-24.1% and the principal of Ig loss is unburned carbon. iii) Fly ash was not suitable to use for mortar and concrete mixture because Ig. loss value is higher than 5% 2. Utilization as insulation material I) The test pieces of original fly ash floats by water floats by ZnCl2 aq(SpG=1.71) p, p t by ZnCl2 aq.(SpG=1.71) that were fired at 110$0^{\circ}C$ represented 0.11-0.18 kcal/mh$^{\circ}$ C as thermal conductivity value. ii) The test pieces which (76.5-85.5) wt% fly ash-(8.5, 9.5) wt% clay-(5.0-15.0) wt% saw dust system(68.0-72.0) wt% fly ash -(17.0-18.0)wt% clay-(10.0-15.0) wt% saw dust system and 59.5 wt% fly ash-25.5 wt% clay-15.0wt% saw dust system were fired at 110$0^{\circ}C$ the thermal conductivity was less than 0.1Kcal/mh$^{\circ}$ C. iii) In view of thermal conductivity and economic aspect insulation materials which added saw dust as blowing agent and clay as inorganic binder are better than that of fly ash as it is or separated hollow fly ash particles. iv) When the saw dust contents increased in the (59.5-90.0) wt% saw dust system and when amount of clay de-creased and firing temperature decreased under the condition of equal addition of saw dust app. porosity increased but bulk density compressive strength and thermal conductivity decreased.

  • PDF

Evaluation of Fine Dust Diffusion and Contamination Degree : Focused on the Operation Status of Donghae Port (항만 인근 미세먼지 노출 영향권 및 오염도 분석 :동해항 운영현황을 중심으로)

  • Hwang, Je-Ho;Kim, Si-Hyun;Kang, Dal-Won
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.251-258
    • /
    • 2022
  • Donghae Port is adjacently located to a residential area wherein 26,933 generations are creating a living environment. The areas comprise Song-jeong village (5,754 generations) and Bukp-yeong village (21,179 generations). Major cargoes handled in Donghae Port are dusty limestone, cement, anthracite, and bituminous coal, etc. In the process of handling such cargoes, air pollutants including oxide dust and fine dust which adversely impact the living conditions and health of residents are generated, causing air pollution in the vicinity of the port. Currently, Donghae Port is making an effort to improve the operation environment of the infrastructure and equipment in stages, for the purpose of reducing air pollutant emissions caused by the port industries in a long-term perspective. In this study, the sphere of influence of fine dust exposure and the degree of air pollution in the surrounding area were analyzed such as the state of fine dust concentration and diffusion in the vicinity of Donghae Port, fine dust diffusion pattern and spatial distribution of high-concentration considering wind direction and speed characteristics during the day and seasonal cycles. A more effective plan to reduce the concentration of fine dust in nearby areas by combining reduction plan, is being developed in terms of improvement regarding port infrastructure and equipment, and reduction measures considering the characteristics of the atmosphere environment according to the daytime, nighttime and season.

Fine particulate Judgment based on Fuzzy Inference System (FUZZY 추론 시스템 기반 미세먼지 판단)

  • Hong, You-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.127-133
    • /
    • 2020
  • The international cancer research institute under the WHO designated fine dust as a first-class carcinogen. Particular matter refers to dust that is small enough to be invisible and floating in the air. Particular matter is mainly emitted from the combustion process of fossil fuels such as coal and oil, and is a risk factor that can cause lung disease, pneumonia, and heart disease. The Ministry of Environment recently analyzed the output data of 10 fine dust measuring stations and, as a result, announced that about 60% had an error that the existing atmospheric measurement concentration was higher. In order to accurately predict fine dust, the wind direction and measurement position must be corrected. In this paper, in order to solve these problems, fuzzy rules are used to solve these problems. In addition, in order to calculate the fine particulate sensation index actually felt by pedestrians on the street, a computer simulation experiment was conducted to calculate the fine particulate sensation index in consideration of weather conditions, temperature conditions, humidity conditions, and wind conditions.