• Title/Summary/Keyword: Co-fired Power plant

Search Result 93, Processing Time 0.024 seconds

A Study On the Design Of Fuzzy Controller for the Steam Temperature Process in the Coal Fired Power Plant

  • Shin, Sang-Doo;Kim, Yi-Gon;Lee, Bong-Kuk
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.350-353
    • /
    • 2003
  • In this paper, we proposed the method to design fuzzy controller using the experience of the operating expert and experimental numeric data for the robust control about the noise and disturbance instead of the traditional PID controller for the main steam temperature control of the thermal power plant. The temperature of main steam temperature process has to be controlled uniformly for the stable electric power output. The process has the problem of the hunting for the cases of various disturbances. In that case, the manual action of the operator happened to be introduced in some cases. We adopted the TSK (Takagi-Sugeno-Kang) model as the fuzzy controller and designed the fuzzy rules using the informations extracted directly from the real plant and various operating condition to solve the above problems and to apply practically. We implemented the real fuzzy controller as the Function Block module in the DCS(Distributed Control System) and evaluated the feasibility through the experiment81 results of the simulation.

  • PDF

Concentration and Geochemical Phases of Heavy Metals in Marine Sediments in the Vicinity of the Coal-fired Power Plant of Korea (석탄화력발전소 주변해역 퇴적물 내의 중금속원소의 함량과 지화학적 존재형태)

  • Lee, Doo-Ho;Jeong, Yeon-Tae
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.4
    • /
    • pp.301-314
    • /
    • 2000
  • Marine surface sediments in the vicinity of Samcheonpo coal-fired power plant were analyzed by a total analysis($HF+HNO_3+HClO_4$) and sequential extraction procedure for heavy metals in order to investigate the total concentrations and geochemical phases of heavy metals. The result showed that the concentrations of Cr, Cu, Fe and Zn were within ranges typical for coastal areas, which reflected the mineralogical composition of the sediments in the studied area. However, the distributions of Cd, Co, Mn, Ni and Pb were rather different from the former, indicating that these heavy metals had a different origin, or that they were affected by a different geochemical mechanism. Chemical partitioning of heavy metals using sequential extraction procedure revealed that Cu, Fe, Pb, Zn were significantly bound to the residual phases of the sediments, whereas carbonate phases contained considerable amounts of Mn. The significant association of Pb with the exchangeable fraction also indicated that Pb was more mobile and bioavailable than Cu, Fe, Mn, Zn.

  • PDF

Experimental study on capture of carbon dioxide and production of sodium bicarbonate from sodium hydroxide

  • Shim, Jae-Goo;Lee, Dong Woog;Lee, Ji Hyun;Kwak, No-Sang
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.297-303
    • /
    • 2016
  • Global warming due to greenhouse gases is an issue of great concern today. Fossil fuel power plants, especially coal-fired thermal power plants, are a major source of carbon dioxide emission. In this work, carbon capture and utilization using sodium hydroxide was studied experimentally. Application for flue gas of a coal-fired power plant is considered. Carbon dioxide, reacting with an aqueous solution of sodium hydroxide, could be converted to sodium bicarbonate ($NaHCO_3$). A bench-scale unit of a reactor system was designed for this experiment. The capture scale of the reactor system was 2 kg of carbon dioxide per day. The detailed operational condition could be determined. The purity of produced sodium bicarbonate was above 97% and the absorption rate of $CO_2$ was above 95% through the experiment using this reactor system. The results obtained in this experiment contain useful information for the construction and operation of a commercial-scale plant. Through this experiment, the possibility of carbon capture for coal power plants using sodium hydroxide could be confirmed.

A Welding Characteristics of Large Caliber-Thick Plate Pressure Vessel Low Alloy Steel (Mn-Mo) (대구경-후판 압력용기용 저 합금강(Mn-Mo)의 용접특성)

  • Ahn, Jong-Seok;Park, Jin-Keun;Yoon, Jae-Yeon
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.10-14
    • /
    • 2012
  • Recently the low alloy steel plate made with manganese-molybdenum is used widely in steam drum and separator of the new coal-fired power plant boiler. This material is suitable for the vapor storage of high pressure and high temperature. The high temperature creep strength of Mn-Mo alloy is higher than the carbon plate(SA516) that used in the subcritical pressure boiler. It reduces the thickness of the pressure vessel and makes the lightweight possible. Recently in the power plant boiler operation and production process, the damage has happened frequently in the heat affected zone and base material according to the hydrogen crack and delayed crack. This paper describes the research result about the damage case experienced in the boiler steam drum production process and present the optimum manufacture method for the similar damage prevention of recurrence.

A Study on Competitiveness and GHG Mitigation Effect of IGCC and Carbon Capture Technology According to Carbon Tax Change (탄소세 변화에 따른 IGCC와 이산화탄소 저감기술 진입경쟁력 및 온실가스 저감효과 분석)

  • Jeon, Young-Shin;Kim, Young-Chang;Kim, Hyung-Taek
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.54-66
    • /
    • 2008
  • After the Kyoto Protocol has been ratified in Feb. 16 2005, the developed countries which is involved in Annex-1 have tried to mitigate GHG to the reduction objective. To accomplish this objective, EU developed EU-ETS, CDM project, and so on. Korea has faced pressure to be a member of Annex-1, because Korea and Mexico are only non-Annex-1 countries in the OECD nations. In this study, we simulated power plant expansion plan and calculated $CO_2$ emission with changing Carbon Tax. Especially, we focused on the competitiveness of IGCC and carbon capture technology. In our result, even though carbon tax rise, nuclear power plant does not always increase, it increase up to minimum load. LNG combined cycle power plants substitute the coal fired power plants. If there are many alternatives like IGCC, these substitute a coal fired power plant and we can reduce more $CO_2$ and save mitigation cost.

Performance Evaluation of an Oxy-coal-fired Power Generation System - Thermodynamic Evaluation of Power Cycle (순산소 석탄 연소 발전 시스템의 성능 평가 - 동력 사이클의 열역학적 해석)

  • Lee, Kwang-Jin;Choi, Sang-Min;Kim, Tae-Hyung;Seo, Sang-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • Power generation systems based on the oxy-coal combustion with carbon dioxide capture and storage (CCS) capability are being proposed and discussed lately. Although a large number of lab scale studies for oxy-coal power plant have been made, studies of pilot scale or commercial scale power plant are not enough. Only a few demonstration projects for oxy-coal power plant are publicized recently. The proposed systems are evolving and various alternatives are to be comparatively evaluated. This paper presents a proposed approach for performance evaluation of a commercial 100 MWe class power plant, which is currently being considered for 'retrofitting' for the demonstration of the concept. The system is configurated based on design and operating conditions with proper assumptions. System components to be included in the discussion are listed. Evaluation criteria in terms of performance are summarized based on the system heat and mass balance and simple performance parameters, such as the fuel to power efficiency and brief introduction of the second law analysis. Also, gas composition is identified for additional analysis to impurities in the system including the purity of oxygen and unwanted gaseous components of nitrogen, argon and oxygen in air separation unit and $CO_2$ processing unit.

CO2 dry-ice cleaning for the removal of air preheater plugging in coal-fired power plant. (석탄 화력발전소의 공기예열기 막힘 제거를 위한 CO2 드라이아이스 세정)

  • Ju, Saerom;Kim, Gyeong-Min;Kim, Do-Jung;Kim, Dong-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.204-206
    • /
    • 2014
  • 석탄 화력발전소에는 연소가스의 질소산화물(NOx) 저감을 위한 SCR(selective catalytic reduction)설비가 운전되고 있으며, SCR은 환원제인 암모니아($NH_3$)를 이용하여 연소가스 내에 질소산화물을 물과 질소로 분해하는 역할을 한다. 그러나, 연소가스 중의 일부 삼산화황($SO_3$)과 미반응 암모니아가 결합하여 황산암모늄염(Ammonium bisulfate; $NH_4HSO_4$)을 생성하며, 이는 후단 APH(air preheater)의 열소자에 점착된 후 분진들과 함께 성장하여 막힘을 야기한다. 막힘이 발생된 APH는 연소가스의 흐름을 방해하기 때문에 차압을 증가시키며, 이는 발전효율의 감소뿐만 아니라 급전정지를 초래한다. 이를 해결하기 위하여 $CO_2$ 드라이아이스 세정 방법을 적용하였으며, pilot-scale plant에서 실험을 수행하였다. 또한, 드라이아이스 공정변수인 분사압력과 분사시간을 제어하여 pilot-scale plant의 APH 열소자 표면에 생성되어있는 오염물질들의 제거효율을 관찰한 결과 95 %의 높은 제거효율을 보였다.

  • PDF

CO2 sequestration and heavy metal stabilization by carbonation process in bottom ash samples from coal power plant

  • Ramakrishna., CH;Thriveni., T;Nam, Seong Young;kim, Chunsik;Ahn, Ji Whan
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.74-83
    • /
    • 2017
  • Coal-fired power plants supply roughly 50 percent of the nation's electricity but produce a disproportionate share of electric utility-related air pollution. Coal combustion technology can facilitate volume reduction of up to 90%, with the inorganic contaminants being captured in furnace bottom ash and fly ash residues. These disposal coal ash residues are however governed by the potential release of constituent contaminants into the environment. Accelerated carbonation process has been shown to have a potential for improving the chemical stability and leaching behavior of bottom ash residues. The aim of this work was to quantify the volume of $CO_2$ that could be sequestrated with a view to reducing greenhouse gas emissions and stabilize the contaminated heavy metals from bottom ash samples. In this study, we used PC boiler bottom ash, Kanvera reactor (KR) slag and calcined waste lime for measuring chemical analysis and heavy metals leaching tests were performed and also the formation of calcite resulting from accelerated carbonation process was investigated by thermo gravimetric and differential thermal analysis (TG/DTA).

Modeling and Parameter Identification of Coal Mill

  • Shin, Hwi-Beom;Li, Xin-Lan;Jeong, In-Young;Park, Jong-Man;Lee, Soon-Young
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.700-707
    • /
    • 2009
  • The coal mill used in the coal-fired power plants is modeled in view of the controller design rather than the educational simulator. The coal mass flow and the outlet temperature are modeled by reinvestigating the mass balance and heat balance models physically. The archived data from a plant database are utilized to identify the model parameters. It can be seen that the simulated model outputs are well matched with the measured ones. It is also expected that the proposed model is useful for the controller design.

Development of Emission Factors for Greenhouse Gas (CO2) from Bituminous coal Fired Power Plants (에너지사용시설의 온실가스 배출 특성 연구 -유연탄 화력발전소의 이산화탄소를 중심으로-)

  • Jeon Eui Chan;Sal Jae Whan;Lee Seong Ho;Jeong Jae Hak;Kim Ki Hyun;Bae Wi Sup
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.107-116
    • /
    • 2006
  • The main purpose of this study is to develop the greenhouse gas emission factor for power plant using bituminous coal. The power plant is a major source of greenhouse gases among the sectors of fossil fuel combustion, thus information of its emission factors is very essential to the establishment of control strategies for the greenhouse gas emissions. These emission factors derived in this study were compared with those of U. S. EPA, AGO and CCL. The $CO_{2}$ concentrations in the flue gas were measured using NDIR analyser and the GC-FID with a methanizer. The amount of carbon (C) and hydrogen (H) in fuel was measured using an elemental analyzer. Calorific values of fuel were also measured using a calorimeter. Caloric value of bituminous coal used in the power plants were 5,957 (as received basis), 6,591 (air-dried basis) and 6,960 kcal/kg (dry basis). Our estimates of carbon emission factors were lower than those of IPCC. The CO2 emission factors for the power plants using bituminous coal were estimated to be 0.791 Mg/MWh (by carbon contents and caloric value of the fuel) and 0.771 Mg/MWh (by $CO_{2}$ concentration of the flue gas). The $CO_{2}$ emission factors estimated in this study were $3.4\sim 5.4\%$ and $4.4\sim 6.7\%$ lower than those of CCL (2003) and U. S. EPA (2002).