• Title/Summary/Keyword: Co-exposure

Search Result 1,004, Processing Time 0.029 seconds

Endoplasmic Reticulum Stress Response and Apoptosis via the CoCl2-Induced Hypoxia in Neuronal Cells (CoCl2 처리로 유도된 hypoxia상태에서 세포자살과 ER stress에 관련된 인자의 발현)

  • Kim, Seon-Hwan;Kwon, Hyon-Jo;Koh, Hyeon-Song;Song, Shi-Hun;Kwon, Ki-Sang;Kwon, O-Yu;Choi, Seung-Won
    • Journal of Life Science
    • /
    • v.20 no.12
    • /
    • pp.1820-1828
    • /
    • 2010
  • Cobalt(II) chloride, a chemical compound with the formula$CoCl_2$, has been widely used in the treatment of anemia, as a chemical agent for the induction of hypoxia in cell cultures, and is known to activate hypoxic signaling. However, excessive exposure to cobalt is associated with several clinical conditions, including asthma, pneumonia, and hematological abnormalities, and can lead to tissue and cellular toxicity. It is also known to induce apoptosis. One of the questions was that of whether $CoCl_2$ might induce apoptosis via endoplasmic reticulum (ER) stress in neurons. To address this question, first, the level of DNA fragmentation was measured for assay of apoptotic rates using $CoCl_2$ with neuron PC12 cells. After confirmation of apoptosis inductions, under the same conditions, the expression levels of ER stress associated factors [ER chaperones Bip, calnexin, ERp72, ERp29, PDI, and ER membrane kinases (IRE1, ATF6, PERK)] were examined by RT-PCR and Western blotting. These results indicated that apoptosis is induced through activation of ER membrane kinases via ER stress. In conclusion, during induction of apoptosis through $CoCl_2$-induced hypoxia in neuron PC12 cells, ER membrane kinase of IRE1 was dominantly up-expressed, and, consecutively, TRAF2, which has been suggested to be one of the links connecting apoptosis and ER stress, was strongly up-expressed.

Hemodynamics Effects of $CO_2$ Insufflation During Thoracoscopy (흉강경시 $CO_2$에 의한 혈역학적 영향)

  • 손동섭;원경준
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.723-727
    • /
    • 1996
  • An adequate exposure is important in thoracoscopic procedures. The insufflation of $CO_2$has been demonstrated to aid in compressing lung parenchyma, and act as a retractor when combined with changes in patient's position. However, a recent study demonstrated that $CO_2$insufflation during thoracoscopy in the pig has adverse hemodynamic consequences. We prospectively studied 12 patients undergoing thoracoscopy to evaluate the effect of $CO_2$insufflation in the clinical setting. The mean arterial pressure, heart rate, central venous pressure, arterial oxygen saturation, and end-tidal $CO_2$pressure were monitored. Measurements were determined at baseline, at the initiation of one-lung ventilation, and at intrapleural pressure of 5, 10, 15 mmHg and following results were obtained. 1) The insufflation of 5 to 15 mmHg of $CO_2$had no significant effect on the mean arterial pressure, heart rate, arterial oxygen saturation. 2) The end-tidal $CO_2$pressure rose from 31.00$\pm$1.67 mmHg to 38.49$\pm$1.82 mmHg at an intrapleural pressure of 15 mmHg(p<0.05). 3) The central venous pressure rose from 7.75$\pm$0.76 mmHg to 12.83$\pm$1.64 mmHg and 16.16$\pm$l.97mmHg at an intrapleural pressure of 10 and 15 mmHg(p<0.05). 4) The low pressure (<10 mmHg) insufflation is a safe adjunct to the conduct of thoracoscopic surgical procedures.

  • PDF

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

An Experimental Research on Uniform Corrosion of Inconel 600 and 690 Tubing Material (Inconel 600 및 690 튜브 재질의 일반 부식에 관한 실험적 연구)

  • Yeom Yu-Sun;Hwang Jung-Lae;Jun In-Sub;Kim Soong-Pyung;Yoon Jang-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.103-116
    • /
    • 2006
  • By executing corrosion experiment on Inconel 600, 690 used to material of S/G tube in domestic NPP, this paper show estimation of amount of product such as Co-58, Co-60, Cr-51, Mn-54, Fe-59 which are main exposure cause to the workers in NPP. Therefore, Making the 12 samples consisted of Inconel 600, 690, whole corrosion experiment was carried out for 60 days(each pH by 20 days). The conditions of those tests were similar or more harsh than actual conditions of domestic NPP. The Glow Discharge Spectrometer(GDS) was used for quantitative analysis of results. The results of using GDS, the Inconel 600 corrodes more than Inconel 690 at pH 7 and pH 9. However, it is observed that Inconel 690 corrodes more than Inconel 600 at pH 4. Those results is estimated that test sections had the effect of transient. The long terms of experiment is required to minimize and solve the problem.

  • PDF

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

Effects of Elevated Carbon Dioxide on the Fruiting Initiation and Development of Grifola frondosa (이산화탄소가 잎새버섯의 자실체 발생 및 생육에 미치는 영향)

  • Chi, Jeong-Hyun;Kim, Jeong-Han;Ju, Young-Cheoul;Seo, Geon-Sik;Kang, Hee-Wan
    • The Korean Journal of Mycology
    • /
    • v.37 no.1
    • /
    • pp.60-64
    • /
    • 2009
  • Effects of $CO_2$ concentration (500, 800, 1,000 and 1,500 ppm) on the initiation and development of fruit body of Grifola frondosa on sawdust cultivation were studied. Optimum concentrations of carbon dioxide for the initiation and development of the fruit body showed the ranges from 500 to 800 ppm. Fruit body initiation was accelerated at lower than 800 ppm $CO_2$ exposure but the maturing of the fruit body was not influenced by above treated $CO_2$ concentrations. The higher ratio of primordial formation, faster fruit body initiation and higher yield were obtained at below 800 ppm of $CO_2$ level, whereas over 1,000 ppm of $CO_2$ levels showed abnormal and lower quality of fruiting bodies. Based on the above results, it is concluded that the favorable $CO_2$ level for bag culture of G. frondosa was below 800 ppm.

A Test to Compare the Water Resistance Sun Protection Factor of General Water, Artificial Seawater, and Natural Seawater of Sunscreen (자외선 차단제의 일반 물, 인공 해수, 자연 해수의 내수성 차단지수를 비교하기 위한 시험)

  • Hyoung Hoon Hwang;Eun Young Kang;Su Yeong Kim;Hui Jeong Jung;Jun Seong Yang;Won Kyu Hong;Hong Suk Kim
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.349-354
    • /
    • 2023
  • Sunscreen is a product that protects against ultraviolet rays by blocking and scattering ultraviolet rays, and has now become a daily necessity beyond cosmetics. Applying sunscreen is a common and easy way to prevent skin damage caused by ultraviolet rays. Due to its significance, the evaluation of sunscreen has evolved since its regulation by the FDA in 1978, progressing to standardized methods established by ISO. Additionally, to assess the loss of sunscreen due to activities such as water exposure or sweating, the Ministry of Food and Drug Safety in Korea and ISO have established protocols for evaluating the water-resistant sun protection factor (SPF). However, existing evaluations of water resistance have been mainly confined to test methods involving plain water, and methods accounting for the impact of seawater during activities like beach leisure, sports, and recreation are yet to be established. Based on the existing guidelines for testing the water-resistant UV protection index, this study compared the water-resistant UV protection index in water, artificial seawater (salt water) and natural seawater (sea water) to evaluate the UV protection index in real-world situations such as marine leisure, sports, and leisure activities. Through these results, we were able to compare the differences between water resistance sun protection index tests in ordinary water, artificial seawater, and natural seawater, and suggest a method for water resistance sun protection index tests using natural seawater.

Electroactive Polymer Composites as a Tactile Sensor for Biomedical Applications

  • Kim GeunHyung
    • Macromolecular Research
    • /
    • v.12 no.6
    • /
    • pp.564-572
    • /
    • 2004
  • Modem applications could benefit from multifunctional materials having anisotropic optical, electrical, thermal, or mechanical properties, especially when coupled with locally controlled distribution of the directional response. Such materials are difficult to engineer by conventional methods, but the electric field-aided technology presented herein is able to locally tailor electroactive composites. Applying an electric field to a polymer in its liquid state allows the orientation of chain- or fiber-like inclusions or phases from what was originally an isotropic material. Such composites can be formed from liquid solutions, melts, or mixtures of pre-polymers and cross-linking agents. Upon curing, a 'created composite' results; it consists of these 'pseudofibers' embedded in a matrix. One can also create oriented composites from embedded spheres, flakes, or fiber-like shapes in a liquid plastic. Orientation of the externally applied electric field defines the orientation of the field-aided self-assembled composites. The strength and duration of exposure of the electric field control the degree of anisotropy created. Results of electromechanical testing of these modified materials, which are relevant to sensing and actuation applications, are presented. The materials' micro/nanostructures were analyzed using microscopy and X-ray diffraction techniques.

Experimental Study on CO2 Diffusivity in Cementitious Materials

  • Jung, Sang-Hwa;Lee, Myung-Kue;Kim, Jee-Sang
    • Corrosion Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • The carbonation of concrete is one of the major factors that cause durability problems in concrete structures. The rate of carbonation depends largely upon the diffusivity of carbon dioxide in concrete. The purpose of this study is to identify the diffusion coefficients of carbon dioxide for various concrete mixtures. To this end, several series of tests have been planned and conducted. The test results indicate that the diffusion coefficient increases with the increase of water-cement ratio. The diffusion coefficient decreases with the increase of relative humidity at the same water-cement ratio. The diffusion of carbon dioxide reached the steady state within about five hours after exposure. The content of aggregates also influences the diffusivity of carbon dioxide in concrete. It was found that the diffusion coefficient of cement paste is larger then that of concrete or mortar. The quantitative values of diffusivity of carbon dioxide in this study will allow more realistic assessment of carbonation depth in concrete structures.