• Title/Summary/Keyword: Co/AC

Search Result 640, Processing Time 0.025 seconds

Asymmetric Supercapacitors Based on Co3O4@MnO2@PPy Porous Pattern Core-Shell Structure Cathode Materials

  • Wang, Zihan;Pan, Shuang;Wang, Bing;Qi, Jingang;Tang, Lidan;Liu, Liang
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.346-357
    • /
    • 2021
  • In recent years, supercapacitors have been developed rapidly as a rechargeable energy storage device. And the performance of supercapacitors is depending on electrode materials, the preparation method and performance of electrode materials have become the primary goal of scientific development. This study synthesizes Co3O4@MnO2@PPy cathode material with porous pattern core-shell structure by hydrothermal method and electrodeposition. The result samples are characterized by X-ray diffraction transmission/scanning electron microscope, and X-ray photoelectron spectroscopy. Electrochemical evaluation reveals that electrochemical performance is significantly enhanced by PPy depositing. The specific capacitance of Co3O4@MnO2@PPy is 977 F g-1 at 1 A g-1, the capacitance retention rate of 105%. Furthermore, the electrochemical performance of Co3O4@MnO2@PPy//AC asymmetric supercapacitor assembles with AC as the negative electrode material is significantly better than that of MnO2//AC and Co3O4@MnO2//AC. The capacity of Co3O4@MnO2@PPy//AC is 102.78 F g-1. The capacity retention rate is still 120% for 5000 charge-discharge cycles.

Development of Inter-link Converter for Power Transmission between Heterogeneous Systems (이종 계통 간의 전력전달을 위한 Inter-link 컨버터 개발)

  • Kim, Sun-Pil;Kim, Kuk-hyeon;Lee, Chang-ho;Le, Tuan-Vu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.111-119
    • /
    • 2022
  • This paper is about power transfer between heterogeneous systems in zero-energy buildings. Currently, electricity used in buildings, from renewable energy generation power in buildings, consists of alternating current networks. In order to use electricity, alternating current must be converted to direct current, which typically results in a loss of 10%. In order to solve this problem, research is needed to reduce power loss as much as possible by implementing both a DC network and an AC network in a zero-energy building. Therefore, in this paper, an inter-link converter capable of bidirectional power transfer between DC and AC networks applied to zero-energy buildings is developed. The structure of the inter-link converter to be developed was proposed and its feasibility was verified through simulations and experiments.

The development on Power supply for Pulsed $CO_2$ laser using half-rectified AC frequency control and leakage transformer (누설 변압기를 이용한 반파 AC 주파수 제어형 $CO_2$ 레이저의 전원장치 개발)

  • Chung, Hyun-Ju;Kim, Do-Wan;Lee, Dong-Hoon;Lee, Yu-Su;Kim, Hee-Je;Cho, Jung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.82-85
    • /
    • 2000
  • We introduce pulsed $CO_2$ laser power supply excited by half-wave rectified 60Hz AC discharge some advantage of cost and size compared to a typical pulsed power supply. AC frequency is adjusted from 10Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage AC discharge circuits is employed to avoid the HV sampling or switching. The control is achieved by using a ZCS circuit and a PIC one-chip microprocessor that control the gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to a high leakage inductance. The maximum laser output was obtained about 20W at the condition of total pressure, 18Torr and pulse repetition rate,60Hz.

  • PDF

$NH_3$ oxidation using Ag-Cu/$Al_2O_3$ composite catalyst at low temperature (Ag-Cu/$Al_2O_3$ 복합촉매를 이용한 저온에서의 $NH_3$ 산화)

  • Lim, Yun-Hui;Lee, Ju-Yeol;Park, Byung-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.313-319
    • /
    • 2014
  • This study was performed to obtain high conversion efficiency of $NH_3$ and minimize generation of nitrogen oxides using metal-supported catalyst with Ag : Cu ratio. Through structural analysis of the prepared catalyst with Ag : Cu ratio ((10-x)Ag-xCu ($0{\leq}x{\leq}6$)), it was confirmed that the specific surface area was decrease with increasing metal content. A prepared catalysts showed Type II adsorption isotherms regardless of the ratio Ag : Cu of metal content, and crystalline phase of $Ag_2O$, CuO and $CuAl_2O$ was observed by XRD analysis. In the low temperature($150{\sim}200^{\circ}C$), a conversion efficiency of AC_10 recorded the highest(98%), whereas AC_5 (Ag : Cu = 5 : 5) also showed good conversion efficiency(93.8%). However, in the high temperature range, the amounts of by-products(NO, $NO_2$) formed with AC_5 was lower than that of AC_10. From these results, It is concluded that AC_5 is more environmentally and economically suitable.

Soluble Production of CMP-Neu5Ac Synthetase by Co-expression of Chaperone Proteins in Escherichia coli (샤페론 단백질 동시 발현기술을 이용한 수용성 CMP-Neu5Ac Synthetase 생산)

  • Choi, Hwa Young;Li, Ling;Cho, Seung Kee;Lee, Won-Heong;Seo, Jin-Ho;Han, Nam Soo
    • Microbiology and Biotechnology Letters
    • /
    • v.42 no.2
    • /
    • pp.190-193
    • /
    • 2014
  • CMP-Neu5Ac synthetase is a key enzyme for the synthesis of CMP-Neu5Ac, which is an essential precursor of sialylated glycoconjugates. For the soluble expression of the CMP-Neu5Ac synthetase gene (neuA) from Escherichia coli K1, various heat shock proteins were co-expressed in E. coli BL21 (DE3) Star. In order to do this, a pG-KJE8 plasmid, encoding genes for GroEL-ES and DnaK-DnaJ-GrpE, was co-transformed with neuA and was expressed at $20^{\circ}C$ by the addition of 0.01 mM IPTG and 0.005 mg/ml L-arabinose. The co-expression of a variety of heat shock proteins resulted in the remarkably improved production of soluble CMP-Neu5Ac synthetase in E. coli.

Ethanol Fermentation of the Enzymatic Hydrolysates from the Products Pretreated using [EMIM]Ac and Its Co-Solvents with DMF

  • Han, Song-Yi;Park, Chan-Woo;Park, Jae-Bum;Ha, Suk-Jin;Kim, Nam-Hun;Lee, Seung-Hwan
    • Journal of Forest and Environmental Science
    • /
    • v.36 no.1
    • /
    • pp.62-66
    • /
    • 2020
  • Ethanol fermentation of the enzymatic hydrolysates from the products pretreated using 1-ethyl-3-methyl-imidazolium acetate ([EMIM]Ac) and its co-solvents with dimethylformamide (DMF) was conducted using Saccharomyces cerevisiae (D452-2). The optical density change due to the yeast cell growth, the consumption amount of monosugars (glucose, xylose), the concentration of acetate, and ethanol production yield were investigated. The co-solvent system lowered inhibition of the growth of the cells. The highest concentration of glucose (7.8 g/L) and xylose (3.6 g/L) was obtained from the enzymatic hydrolysates of the pretreated product by pure [EMIM]Ac. The initial concentration of both monosugars in the enzymatic hydrolysates was decreased with increasing fermentation time. Ethanol of Approximately 3 g/L was produced from the enzymatic hydrolysates by pure [EMIM]Ac and co-solvent with less than 50% DMF.

The transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment used for electrical durability test for magnetic switch (IEC60947-4에 따른 전자개폐기 전기적 수명시험설비의 과도현상을 고려한 SCR최적 정격선정에 대한 연구)

  • Ryu Haeng Soo;Kim Kab Dong;Han Gyu Hwan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.354-356
    • /
    • 2004
  • This paper is the transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment(AC3 TE) used for electrical durability test for magnetic switch according to IEC60947-4 Annex B by utilizing EMTP -ATPDraw. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. The key cost of AC3 TE is the SCR ratings. The more decreases SCR ratings, the more decreased the cost is, but it is impossible to ensure the reliability. On the other hand, the more increases SCR ratings, the more increased the cost is. Thereupon, in this paper after the testing circuit is simulated by using EMTP-ATPDraw the SCR ratings will be applied in order to guarantee the testing reliability of PT&T(Power Testing and Technology institute in LG Industrial Systems Co.,Ltd.).

  • PDF

Study on AC creepage discharge characteristics on polluted solid dielectrics (오염된 고체절연물의 AC 연면 절연파괴특성 분석)

  • Kim, J.T.;Seo, C.W.;Park, H.S.;Kim, B.D.;Jang, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1169-1170
    • /
    • 2015
  • 공기를 주 절연매질로 사용하는 전력기기의 소형화 추세속에서 제품의 절연성능을 확보하기 위해 '절연배리어'인 고체절연물이 사용된다. 고체절연물의 연면 절연성능은 운전 환경에서 발생된 수분 및 오염원 등에 영향을 받기 쉽기 때문에, 다양한 오염도 조건에서 고체절연물의 연면 절연파괴특성 분석이 필요하다. 본 논문에서는 전력기기에 폭넓게 적용되는 있는 고체절연물에 대하여 평등전계가 모의된 평판 - 평판 전극 실험 조건에서 연면거리 및 오염도를 정량화한 전기전도도에 따른 AC 연면 절연파괴특성을 분석하였다. 그 결과, AC 연면 절연파괴전계는 고체절연물 재질에 관계없이 단(短) 갭에서 연면거리에 대한 의존성을 거의 보이지 않았다. 또한, PC 연면 절연파괴전계는 BMC 및 에폭시 대비 높았으며, 이것은 재질에 따른 연면 절연파괴 형태 및 표면의 소수성 차이와 관련이 있는 것으로 사료된다.

  • PDF

Effects of Elevated CO2 and Temperate on the Growth of Endangered Species, Cicuta virosa L. in Korea (CO2농도와 온도 상승이 한국멸종위기식물 독미나리의 생장에 주는 영향)

  • Park, Jae Hoon;Hong, Yong Sik;Kim, Hae Ran;Jeong, Jung Kyu;Jeong, Heon Mo;You, Young Han
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • The effect of elevated $CO_2$ and temperature on ecological characteristics of Cicuta virosa L., the endangered plant were examined under ambient $CO_2$+ambient temperature(AC-AT), ambient $CO_2$+elevated temperature(AC-ET) and elevated $CO_2$+elevated temperature for two years. Shoot length and the number of umbels were not different in three environmental gradients. The number of tillers was high in the order of EC-ET, AC-ET and AC-AT. The number of compound umbel was the lowest in the EC-ET. Fruit set rate was the highest in the AC-AT. These results mean that unsexual propagation of C. virosa may increase by promoting growth of tillers, rather than seed production under future global warming. This population growth study will be used as the important data for the research of Korean endangered species.

Three phase AC output voltage control using three modules of the single phase quasi Z-source AC-AC converter (단상 quasi Z-소스 AC-AC 컨버터 3개 모듈을 이용한 3상 교류 출력 전압 제어)

  • Eom, Jun-Hyun;Jung, Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.43-44
    • /
    • 2014
  • 본 논문에서는 단상 Quasi Z-소스 AC-AC 컨버터 3대를 이용하여 3상 교류 출력전압 제어를 제안하였다. 제안된 시스템은 3대의 단상 Quasi Z-소스 AC-AC 컨버터에 종전의 간단한 듀티비 제어를 통하여 입력에 대하여 동상의 벅-부스트 출력모드와 역상의 벅-부스트 출력모드를 모두 출력하는 4상한 출력 3상 교류 전압 제어를 하였다. PSIM시뮬레이션을 통하여 종전의 듀티비 제어를 통한 동상의 부스트 모드와 역상의 벅-부스트 모드 출력 전압과 제안한 듀티비 제어에 의해 동상의 벅 모드가 출력됨으로써 단상 Quasi Z-소스 AC-AC 컨버터의 간단한 듀티비 제어만을 통하여 3상 4상한 교류 출력전압 제어가 되는 것을 확인하였다.

  • PDF