• 제목/요약/키워드: Closed-loop characteristics

검색결과 252건 처리시간 0.029초

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

간단한 정기구학을 갖는 평면운동용 병렬 매니플레이터의 구동영역 및 기구학적 특성 (Workspace and Kinematical Characteristics of Planar Parallel Manipulator with Simple)

  • 최기봉
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.97-104
    • /
    • 2003
  • This paper proposes a new parallel manipulator fur plane motion, and then discusses on the workspace and kinematical characteristics of the manipulator. The conventional planar parallel manipulators have some disadvantages which are complex non-closed type direct kinematics, workspaces containing useless voids, and concave type border tines of workspaces. The proposed planar parallel manipulator overcomes the above disadvantages, that is, the manipulator has simple closed type direct kinematics, a void-free workspace, and a convex type borderline of a workspace. This paper shows the simulation result of the workspace as well as performances indices using a homogeneous inverse Jacobian.

ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계 (Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter)

  • 이득기;윤길문;차영길;김흥근
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.231-239
    • /
    • 1998
  • 본 논문에서는 대용량에 적합한 영전압 스위칭 전브리지 PWM 직류/직류 변한기의 동특성 해석과 제어 루프의 설계에 대해 논하였다. 전압을 제어하기 위한 위상전이제어의 효과와 영전압 스위칭을 위한 변압기의 누설인덕턴스, FET의 적합 커패시턴스의 이용효과를 고려한 소신호 모델을 유도하였다. 이 소신호 모델은 PWM 벅 변환기의 등가모델에 시비율 변조에 대한 두 개의 종속 전원을 추가함으로써 모델링할 수 있다. 소신호 해석 결과를 근거로 하여 2-극점, 1-영점 보상회로를 사용한 전압제어기를 설계하였다. 설계된 제어기의 타당성을 검증하기 위해서 개루프 시스템과 폐루프 시스템의 소신호 해석결과를 비교하였으며, 2kW급 부하실험으로 설계한 전압제어기의 동특성이 우수함을 실험적으로 입증하였다.

  • PDF

The Effects of Secondary Fuel Injection on Combustion Oscillation

  • Shigeru Tachibana;Laurent Zimmer;Park, Gyung-Min;Takeshi Yamamoto;Ufosawa, Yoji-K;Seiji Yoshida;Kazuo Suzuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.376-379
    • /
    • 2004
  • The purpose of this work is to develop an effective active control system for combustion instabilities of premixed combustors. For the first step, the natural modes of combustion oscillation were investigated for a methane-air premixed combustor and the controls by secondary fuel injection were examined. The main premixed flame is stabilized by a swirler with orifices for secondary injection installed on the central hub. For sensing purposes, a pressure transducer and a chemiluminescence sensor were placed on the appropriate positions. The acoustic characteristics and the source of the oscillation were analyzed by those signals. To test the controllability, two methods of actuations by secondary fuel injection were examined. One is the open loop control and the other is the closed loop control. The comparison of the reduction levels of p $_{rms}$ shows that the closed loop control with a phase-shift injection performs best in this condition.ition.n.

  • PDF

HSDPA 모뎀용 동기추적회로의 설계 및 성능분석 (Design and Performance Analysis of Non-coherent Code Tracking Loops for HSDPA MODEM)

  • 양연실;박형래
    • 한국항행학회논문지
    • /
    • 제7권1호
    • /
    • pp.6-13
    • /
    • 2003
  • 본 논문에서는 3GPP HSDPA 모뎀용 비동기식 동기추적회로를 설계하고, 설계된 동기추적회로에 대하여 정상상태 지터 분산과 타이밍 에러의 과도응답 특성을 이론적으로 분석하였다. 우선 AWGN 환경에서의 지터 분산을 펄스성형 필터, 타이밍 오프셋, 신호 대 잡음비, 루프 대역폭에 대한 식으로 유도하였으며, 과도응답 특성 또한 이론적으로 해석하였다. 끝으로 설계된 동기추적회로의 성능을 컴퓨터 시뮬레이션을 통하여 확인하였다.

  • PDF

격자 지지구조체에 묶여있는 실린더 형 봉의 삽입위치에 따른 진동특성 (Vibration Characteristic of a Cylindrical Rod according to the Mounting Locations on the Grid Support Structure)

  • 이강희;윤경호;송기남;김재용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.515-518
    • /
    • 2006
  • A vibration test for a cylindrical rod inserted on the grid support structure was tested using the sine sweep excitation method with closed loop force control. The effect of the mounting location of a test rod on the vibration characteristics of a rod continuously supported by the full size($16{\times}16$) grid support was identified. An electromagnetic vibration shaker, non-contact displacement sensor and HP/VXI data acquisition device were used and TDAS software was also used as a data sampling and processing tools. The natural frequencies and mode shape of the test rod were consistent with the previous works of a rod vibration test with partial grids($3{\times}3,\;5{\times}5\;and\;7{\times}7$). The frequency characteristics of the rod according to the mounting location were shown clear discrepancies, but mode shapes were nearly same. As the test rod closes to the bottom clamping region of the spacer grid, peak vibration amplitudes of the rod become smaller.

  • PDF

태양광 전력설비를 위한 오차 보상기 사용의 전력변환기기에 대한 응답특성의 효과 검증 (Response Characteristics Effectiveness of Power Converter According to Using of Error Compensator for PV Power System)

  • 김동은;이현재;손진근
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1388-1394
    • /
    • 2018
  • In this paper, the improvement of the control response by using the error compensator to improve the stability of the control in the power conversion system is verified. Typically a closed loop control method is used to improve the control response characteristics in a traditional power conversion system and this is accomplished by generating a PWM waveform. In this paper, the newly constructed Type3 compensator to overcome the existing such as PI controller or Type2 compensator has been developed to improve the control stability of these closed loop control systems and the effectiveness of the use of error compensation devices was verified by presenting technique to improve stability and select its parameters by expanding the range of phase gains. Stability improvements are shown by the extension of the phase gain range and parameter selection techniques and the effects of using the error compensation device are verified accordingly.