• 제목/요약/키워드: Closed cycle system

검색결과 99건 처리시간 0.029초

저온열원의 특성에 따른 ORC 성능해석 최적화 연구 (Optimization Study on the Performance Analysis of Organic Rankine Cycle for Characteristics of Low Temperature Heat Sources)

  • 엄홍선;윤천석;김영민;신동길;김창기
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.51-60
    • /
    • 2012
  • Optimization procedures of performance analysis for ORC(Organic Rankine Cycle) system are established to the characteristics of low temperature heat sources such as open-type and closed-type. Effective heat recovery and heat extraction related to maximum power of the cycle as well as heat quality and thermal efficiency must be considered in the case of the open-type low temperature heat source. On the other hand, in the case of the closed-type low temperature heat source, only thermal efficiency is important due to constant heat input. In this study, thermal efficiency and exergy efficiency representing a level of close to Carnot cycle are studied, as useful index for the optimization of the ORC system. To validate the results of cycle analysis, those are compared with appropriate experimental data of ORC system as a thermal efficiency point of view.

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

물분사식 무공해 수소엔진 개발을 위한 열역학적 해석 (Thermodynamic Analysis to Develop a Pollution-Free Hydrogen Engine with Water Injection)

  • 오병수;마현식;박주호
    • 한국수소및신에너지학회논문집
    • /
    • 제5권2호
    • /
    • pp.91-98
    • /
    • 1994
  • In this study hydrogen gas and oxygen gas are used to make a pollution-free engine which is a closed system with the components such as a combustor, two turbines, a radiator and a compressor. One of the two turbines produces main power, and the other is used to drive a compressor to compress unburned gases and to return them to the combustor. Some of the water from the radiator is pumped to cool down the internal wall of the combustor and to be used as a working fluid which expands from liquid state to vapor state to get more expansion work. The possibility of operating the whole system is checked by the thermodynamic analysis to make the closed engine system. The calculations in the thermal analysis are based on the Brayton cycle and the Rankine cycle. The closed system in this study shows similar efficiency as usual internal combustion engines, but it produces water only without air pollution such as $NO_x$ and soot.

  • PDF

울진 원자력발전소 온배수를 이용한 재생식 해양온도차발전에 대한 연구 (A Study on Regenerative OTEC System using the Condenser Effluent of Uljin Nuclear Power Plant)

  • 강윤영;박성식;박윤범;김남진
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.591-597
    • /
    • 2012
  • For the past few years, the concern for clean energy has been greatly increased. Ocean thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this study, we examined the thermodynamic performance of the OTEC power system for the production of electric power. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regenerative cycle, Kalina cycle, open cycle, and hybrid cycle. The results show that the regenerative cycle showed the best system efficiency. And then we examined the thermodynamic performance of regenerative cycle OTEC power system using the condenser effluent from Uljin nuclear power plant instead of the surface water. The highest system efficiency of the condition was 4.55% and the highest net power was 181 MW.

로켓 프리버너 분사기의 성능특성 연구 (An Experimental Study of the Rocket Preburner Injector)

  • 양준호;소윤석;최현경;최성만;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.47-53
    • /
    • 2006
  • 산화제 과잉 예연소기는 고성능 closed cycle 액체추진로켓 시스템에 적용된다. 이러한 산화제 과잉 연소기는 산화제-연료 혼합비가 약 50이상에서 작동하므로, 예연소기에서 분무특성과 혼합성능이 연소 안정성에 큰 영향을 주게 된다 본 연구에서는 예연소기에 적용 가능한 분사기를 설계하고, 유량측정, 가시화 실험을 수행하여 예연소기 분사기의 분무특성을 연구하기로 한다.

  • PDF

복수정을 이용한 개방형 지열 시스템의 초기투자비 회수기간 분석 (Analysis of the Initial Cost Payback Period on the Open-loop Geothermal System Using Two Wells)

  • 조정흠;남유진
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.119-126
    • /
    • 2017
  • Recently, ground source heat pump systems are being used in buildings for cooling and heating to reduce greenhouse gas and save energy. However, ground source heat pump systems mainly use the vertical closed-loop geothermal system design rather than the open-loop geothermal system design. This is due to a lack of knowledge and few research feasibility studies. In this research, a dynamic thermal analysis numerical simulation based on a standard house model was conducted for an open-loop geothermal system. Based on heating load analysis results, the life cycle costs of a standard house using an open two-well geothermal system were analyzed and compared with a vertical closed-loop geothermal system, and a diesel boiler. As a result, it was found that using an open two-well geothermal system shows economic return on investment after three years.

철도노반재료의 동상 팽창압 특성에 관한 연구 (The Characteristics of Frost Heaving Pressure on the Railroadbed Materials)

  • 신은철;박정준;이창섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.264-270
    • /
    • 2002
  • The frost heaving pressure can be a problem for weakening of the railroadbed material. In this study, upon freezing a saturated soil in a closed-system from the top, a considerable pressure was developed. This pressure is induced as a result of a curved ice-water interface. This study was initiated to investigate the soils frost heaving expansion pressure and physical characteristics resulting from freezing and freezing-thawing cycle process. Weathered granite soils, sandy soil were used in the laboratory freezing test subjected to thermal gradients under closed-systems.

  • PDF

CMOS 기반의 집적 회로 및 시스템을 위한 극저온 측정 환경 구축 (Measurement set-up for CMOS-based integrated circuits and systems at cryogenic temperature)

  • 안현식;최윤석;한정환;남재원;조건희;김주성
    • 전기전자학회논문지
    • /
    • 제28권2호
    • /
    • pp.174-179
    • /
    • 2024
  • 본 논문에서는 극저온 냉동기를 사용하여 양자 컴퓨터 제어 및 read-out을 위한 CMOS 기반의 집적회로 측정 셋업을 제시한다. CMOS 회로는 큐비트 안정성과 잡음 감소를 위해 3~5 K의 극저온에서 작동해야한다. 기존의 극저온 측정 시스템은 액체 헬륨 담금질이며, 이는 소모성 자원을 장기간 사용하기에 비용이 많이 소모된다. 따라서 헬륨 가스를 장기간 사용해도 비용이 들지 않는 폐쇄 사이클 냉동기(Closed Cycle Refrigerator, CCR) 기반의 극저온 측정 시스템에 대해 설명한다. Gifford-Mcmahon(G-M) 방식의 극저온 냉각기를 이용하여 4.7 K에 도달할 수 있는 냉동기를 구축하였다. 이는 가격 경쟁력이 우수한 극저온 냉동기 셋업이 될 것으로 기대된다.

Uranium thermochemical cycle used for hydrogen production

  • Chen, Aimei;Liu, Chunxia;Liu, Yuxia;Zhang, Lan
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.214-220
    • /
    • 2019
  • Thermochemical cycles have been predominantly used for energy transformation from heat to stored chemical free energy in the form of hydrogen. The thermochemical cycle based on uranium (UTC), proposed by Oak Ridge National Laboratory, has been considered as a better alternative compared to other thermochemical cycles mainly due to its safety and high efficiency. UTC process includes three steps, in which only the first step is unique. Hydrogen production apparatus with hectogram reactants was designed in this study. The results showed that high yield hydrogen was obtained, which was determined by drainage method. The results also indicated that the chemical conversion rate of hydrogen production was in direct proportion to the mass of $Na_2CO_3$, while the solid product was $Na_2UO_4$, instead of $Na_2U_2O_7$. Nevertheless the thermochemical cycle used for hydrogen generation can be closed, and chemical compounds used in these processes can also be recycled. So the cycle with $Na_2UO_4$ as its first reaction product has an advantage over the proposed UTC process, attributed to the fast reaction rate and high hydrogen yield in the first reaction step.

철도노반재료의 동상팽창압 및 물리적 특성 평가 (Frost Heaving Pressure and Physical Characteristics of the Railway Roadbed Materials)

  • 신은철;박정준;김종인
    • 한국철도학회논문집
    • /
    • 제8권1호
    • /
    • pp.57-62
    • /
    • 2005
  • The frost heaving pressure can be a problem for weakening of the railway roadbed material. This study was initiated to investigate the soils frost heaving pressure and physical characteristics(Liquid limit, permeability, SEM analysis) resulting from freezing and freezing-thawing cycle process. Therefore, upon freezing a saturated soil in a closed-system from the top, a considerable pressure was developed. Weathered granite soils, sandy soil were used in the laboratory freezing test which sometimes subjected to thermal gradients under closed-systems. The frost heaving pressure arising within the soil samples and the temperature of the samples inside were monitored with elapsed time. The degree of saturation versus heaving pressure curve is also presented for weathered granite soil and the maximum pressure is closely related to this curve. Based on the laboratory test results, fine-grained soils with strong attractive forces between soil grains md water molecules, and additional water is attracted into the pores leading to further volume changes and ice segregation.