• Title/Summary/Keyword: Clinical use

Search Result 5,942, Processing Time 0.038 seconds

Anti-obesity effect of radish leaf extracts on high fat diet-induced obesity in mice (고지방식이를 통해 비만이 유발된 마우스에서 무청 추출물의 항비만 효과)

  • Lee, Yun-Seong;Seo, Young Ho;Kim, Ji Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.3
    • /
    • pp.297-305
    • /
    • 2022
  • The goal of this study was to evaluate the anti-obesity effect of radish leaf extracts (MU-C) and radish leaf extracts with 3% citric acid (MU-CA) in a high-fat diet (HFD)-induced C57BL/6 mice. The effects of radish leaf extracts on adipogenesis were also investigated using 3T3-L1 adipocytes. As determined by Oil red O staining, MU-C inhibited adipogenesis in 3T3-L1 adipocytes. Four-week-old male C57BL/6 mice were fed an HFD for 6 weeks and then treated with radish leaf extracts (500 mg/kg, p.o.) for 6 weeks. Then, the serum levels of Aspartate aminotransferase, Alanine aminotransferase, Total cholesterol, Triglyceride and low-density lipoprotein cholesterol in the mice were measured using an automatic chemical analyzer and enzyme-linked immunosorbent assay. Administration of MU-C significantly reduced the fat weight when compared with HFD controls. As confirmed by histopathologic analysis, adipose tissue size markedly decreased in mice treated with MU-C. Therefore, this study could provide a basis for investigating the clinical use of MU-C as an agent for preventing obesity.

A Study of Test-Retest Reliability and Interrater Reliability of the Sensory Processing Scale for Children (SPS-C) (아동감각처리척도(Sensory Processing Scale for Children; SPS-C)의 검사-재검사 신뢰도와 검사자간 신뢰도 연구)

  • Kim, Kyeong-Mi;Kim, Ga-Yeon;Lee, Seung-Jin
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.20 no.2
    • /
    • pp.11-21
    • /
    • 2022
  • Objective : This study examined the test-retest reliability and interrater reliability of the Sensory Processing Scale for Children (SPS-C). Method : Senventy primary caregivers of children with sensory processing difficulties and 3 years old participated in the study. The subjects were recruited through child development centers, welfare centers, and acquaintances located in Seoul, Gyeonggi-do, Busan, and Gyeongsang-do. The test-retest reliability verification targeted 20 main caregivers of children with difficulty in sensory processing. Re-evaluation was performed within 7 to 14 days after the initial evaluation, and Pearson's correlation coefficient was used to confirm the relevance between the two time points, and the Intraclass correlation coefficient was used to confirm the degree of agreement. The interrater reliability verification was conducted with 18 primary caregivers and 18 subsidiary caregivers of children with sensory processing difficulties. Each caregiver evaluated the same child, and the Intraclass correlation coefficient was used to confirm the agreement between the two sets of caregivers. Results : The test-retest reliability was Pearson's correlation coefficient r=.914 and intraclass correlation coefficient ICC=.939, indicating a high level of relevance and agreement. The interrater reliability was an Intraclass correlation coefficient ICC=.727, which showed a moderate level of agreement, but the tactile area (ICC=.455) and proprioceptive area (ICC=.439) were not statistically significant and showed a low degree of agreement. Conclusion : Through this study, it was confirmed that the children's Sensory Processing Scale for Children (SPS-C) is a stable evaluation tool with test-retest reliability and interrater reliability verified, and it will be able to provide help in standardization studies for future clinical use.

Study on the Safety of Firefly Luciferase in Human as a Transient Reporter Gene of Oncolytic Virotherapy (항암 바이러스 치료제의 보고유전자로써 반딧불이 루시퍼레이즈의 인체 내 안전성에 대한 연구)

  • Hong, Young Mi;Yoon, Woong Hee;Lee, You Ra;Kim, Soo Ji;Ngabire, Daniel;Narayanasamy, Badrinath;Ornella, Mefotse Saha Cyrelle;Kim, Myunghee;Cho, Euna;Lee, Bora;Hwang, Tae-Ho
    • Journal of Life Science
    • /
    • v.31 no.11
    • /
    • pp.1028-1036
    • /
    • 2021
  • Firefly luciferase (FLuc) can function as an efficient marker in the gene and viral therapies. Nonetheless, its clinical translation has been unaccomplished with the concerns on its exogenous nature and the similarity with human fatty acyl-CoA synthetase. In this study, we aimed to show safety of FLuc by conducting a set of preclinical experiments and a human use. Initially, FLuc permeability across the plasma membrane was investigated by delivering the FLuc-carrying viral vector, OTS-412, or the FLuc recombinant protein. After in vitro infection of OTS-412 into different cancer cell lines, FLuc activity was detected only in the cell lysates, but not in culture media. In addition, recombinant FLuc protein further showed the impermeability against the plasma membrane. Similar result was also observed in the in vivo experiment. After being injected into the VX2 tumor-bearing rabbit, the FLuc exclusively resided within the tumor tissue without being detected in the blood plasma or other organs. Human cancer cell lines originated from various organs were lysed and treated to the FLuc, and none of the human substrates was reactive against the FLuc. As a final step, FLuc recombinant protein was intravenously injected into a human. The luciferase was degraded with the half-life of 20 to 30 minutes in blood, and was untraceable from 1.5 hr after the injection. In addition, the blood plasma was nonresponsive against the fatty acids. Hematological analysis was also comparable between the pre- and post-injection. Altogether, our study collectively demonstrates the safety of the firefly luciferase.

Atorvastatin and Fluvastatin Can Reduce IL-1β-induced Inflammatory Responses in Human Keratinocytes (Atorvastatin 그리고 fluvastatin 약물의 IL-1β-유도 염증반응 억제 효과)

  • Choe, Yeong-In;Moon, Kyoung Mi;Yoo, Jae Cheal;Byun, June-Ho;Hwang, Sun-Chul;Moon, Dong Kyu;Woo, Dong Kyun
    • Journal of Life Science
    • /
    • v.31 no.4
    • /
    • pp.418-424
    • /
    • 2021
  • Skin inflammation (dermatitis) is caused by varying skin damage due to ultraviolet radiation and microbial infection. Currently prescribed drugs for dermatitis include anti-histamine and steroid drug classes that soothe inflammation. However, incorrect or prolonged use of steroids can cause weakening of skin barriers as well as osteoporosis. Therefore, treating dermatitis with a drug that has minimal side effects is important. Statins, also known as 3-hydroxy-3-methylglutaryl-coenzyme A reductase inhibitors, are cholesterol-lowering drugs that have been widely treated for hyperlipidemia and cardiovascular diseases. Interestingly, recent studies have shown the anti-inflammatory effects of statins in both experimental and clinical models for of osteoarthritis. This study investigated the possible anti-inflammatory effects of atorvastatin and fluvastatin in human keratinocytes (HaCaT cells), which are crucial components of skin barriers. Stimulation of HaCaT cells with IL-1β increased the expression of the COX2 protein, a major player of inflammatory responses. However, this induction of the COX2 protein was downregulated by pretreatments with atorvastatin and fluvastatin. Treatment with IL-1ß-induced the upregulation of other inflammatory genes (such as iNOS and MMP-1) and these expressions were similarly lowered by these two statin drug treatments. Taken together, these results indicated that atorvastatin and fluvastatin can reduce IL-1β-induced inflammatory responses in HaCaT cells. In conclusion, the findings suggest that atorvastatin and fluvastatin can be potential modulators for ameliorating skin inflammation.

Analysis of Central Line-associated Bloodstream Infection among Infants in the Neonatal Intensive Care Unit: A Single Center Study

  • Kim, Minhye;Choi, Sujin;Jung, Young Hwa;Choi, Chang Won;Shin, Myoung-jin;Kim, Eu Suk;Lee, Hyunju
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.3
    • /
    • pp.133-143
    • /
    • 2021
  • Purpose: This study aimed to determine the incidence of central line-associated bloodstream infection (CLABSI) in the neonatal intensive care unit (NICU), evaluate the patients' clinical characteristics, and identify the etiologic agents for guidance in prevention and treatment. Methods: A retrospective chart review study of infants classified as having CLABSI was conducted at the NICU of Seoul National University Bundang Hospital from January 2016 to December 2020. Results: Of the 45 infants, 53 had CLABSIs within a follow-up period of 18,622 catheter days. The incidence of CLABSIs was 2.85 per 1,000 catheter days. The most common catheter type was a peripherally inserted central catheter (n=47, 81%). A total of 57 pathogens were isolated, of which 57.9% (n=33) were Gram-positive bacteria, 36.8% (n=21) were Gram-negative bacteria, and 5.3% (n=3) were Candida spp. The most common pathogens were Staphylococcus aureus (n=12, 21%) and coagulase-negative staphylococci (n=12, 21%), followed by Klebsiella aerogenes (n=8, 14%). The median duration of bacteremia was 2 days, and 19 episodes showed bacteremia for 3 days or more. The mortality rate of infants within 14 days of CLABSI was 13.3% (n=6). Conclusions: This study analyzed the incidence of CLABSI and the distribution of pathogens in the NICU. Continuous monitoring of CLABSI based on active surveillance serves as guidance for empiric antibiotic use and also serves as a tool to assess the necessity for implementation of prevention strategies and their impact.

Evaluation of Setting Time, Solubility, and Compressive Strength of Four Calcium Silicate-Based Cements (네 가지 규산 칼슘계 시멘트의 경화시간, 용해도, 압축강도 평가)

  • Yuji Jang;Yujin Kim;Junghwan Lee;Jongsoo Kim;Joonhaeng Lee;Mi Ran Han;Jongbin Kim;Jisun Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.217-228
    • /
    • 2023
  • This study aimed to compare the physical properties of 4 kinds of calcium silicate-based cements (CSCs): 2 kinds of powder-liquid mix type (RetroMTA® [RTMX] and Endocem® MTA Zr [EZMX]) and 2 kinds of premixed type (Well-RootTMPT [WRPR] and Endocem® MTA premixed [ECPR]) CSCs, respectively. Further, we assessed the setting times, solubility values, and compressive strengths of the cements. The shortest setting time was observed for EZMX (123.33 ± 5.77 seconds), followed by RTMX (146.67 ± 5.77 seconds), ECPR (260.00 ± 17.32 seconds), and WRPR (460.00 ± 17.32 seconds), respectively. The highest solubility was observed for WRPR (9.01 ± 0.55%), followed by RTMX (2.17 ± 0.07%), EZMX (0.55 ± 0.03%), and ECPR (0.17 ± 0.03%). Furthermore, the highest compressive strength was observed for ECPR (76.67 ± 25.67 Mpa), followed by WRPR (38.39 ± 7.25 Mpa), RTMX (35.07 ± 5.34 Mpa), and EZMX (4.07 ± 0.60 Mpa). In conclusion, the premixed type CSCs (WRPR and ECPR) exhibited longer setting times compared to the powder-liquid mix type CSCs (EZMX and RTMX). The solubility test showed that ECPR had the lowest solubility while WRPR had the highest solubility, with a statistically significant difference between them (p < 0.0083). Additionally, the compressive strength test showed that ECPR had the highest compressive strength, while EZMX had the lowest compressive strength, also with a statistically significant difference between them (p < 0.0083). ECPR is a promising material as it is premixed, eliminating the need for mixing time, and it has also demonstrated improved solubility and compressive strength, making it a potentially favorable option for clinical use.

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

A Study on the Distribution of Mycoplasma pneumoniae Infectious Disease in Children from 2016 to 2018 According to Age (2016년에서 2018년의 소아 마이코플라즈마폐렴균 감염질환의 연령별 발생분포에 대한 연구)

  • Junhyung Choi;Ki Hwan Kim
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.3
    • /
    • pp.121-128
    • /
    • 2023
  • Purpose: This study aimed to investigate the recent age distribution of Mycoplasma pneumoniae in patients with respiratory infections and the differences in diagnostic usefulness according to the methods used in these patients. Methods: We retrospectively reviewed the medical records of patients aged ≤18 years with respiratory infectious diseases who underwent polymerase chain reaction (PCR) or a specific immunoglobulin M (IgM) test between July 2016 and February 2019. The diagnosis of M. pneumoniae infection was confirmed by a positive result in the PCR or IgM test. Results: Of the 2,721 patients tested for M. pneumoniae, 2,197 underwent IgM, and 1,144 underwent PCR, with positivity rates of 17% and 20%, respectively. Among the 620 patients tested for both IgM and PCR tests simultaneously, 35% had M. pneumoniae infection, with 14% under 1 year old and 13% under 1-2 years old. The positive rate increased with age in both tests. Higher positive rates were observed in the IgM test before 3 years of age and in the PCR test after 3 years of age. The agreement rate between the two tests was 77.9% (Cohen's kappa 0.402). Conclusions: As age increased, the rates of M. pneumoniae infection also increased. In patients under 2 years of age, 4¬-14% of infections were confirmed depending on the method used. The moderate agreement between the PCR and IgM tests suggests that the simultaneous use of PCR and the IgM test for the early diagnosis should be approached with caution.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.