• Title/Summary/Keyword: Clinical torque

Search Result 84, Processing Time 0.025 seconds

Norm-referenced criteria for strength of the elbow joint for the korean high school baseball players using the isokinetic equipment: (Focusing on seoul and gyeonggi-do) (등속성 장비를 이용하여 한국고교야구선수 주관절 근력 평가기준치 설정: (서울 및 경기도 중심으로))

  • Kim, Su-Hyun;Lee, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.442-447
    • /
    • 2017
  • The purpose of this study was to establish norm-referenced criteria for the isokinetic strength of the elbow joint in Korean high school baseball players. Two hundred and one high school baseball players participated in this study, none of whom had any medical problem with their upper limbs. The elbow flexion/extension test was conducted four times at a speed of $60^{\circ}/sec$. The HUMAC NORM (CSMI, USA) system was used to obtain the values of the peak torque and peak torque per body weight. The results were presented as norm-referenced criterion valuesusing the 5-point scale of Cajori which consists of five stages (6.06%, 24.17%, 38.30%, 24.17%, and 6.06%). In the results of this study, the peak torques of the elbow (flexor and extensor?) at an angular velocity of $60^{\circ}/sec$ were $37.88{\pm}8.14Nm$ and $44.59{\pm}11.79Nm$, and the peak torque per body weight of the elbow (flexor and extensor?) were $50.06{\pm}8.66Nm$ and $58.28{\pm}12.84Nm$, respectively. The reference values of the peak torque and peak torque per body weight of the elbow flexor and extensor were setat an angular velocity of $60^{\circ}/sec$. On the basis of the results analyzed in this study, the following conclusions were drawn. There is a lack of proper studies on the elbow joint strength, even though the most common injury in baseball players occurs in the elbow joint. Therefore, we need to establish a standard muscle strength in order to prevent elbow joint injuries and improve their performance. The criteria for the peak torque and peak torque per body weight established here in will provide useful information for high school baseball players, baseball coaches, athletic trainers and sports injury rehabilitation specialists in injury recovery and return to rehabilitation, which can beutilized as objective clinical assessment data.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

Treatment of Deep Infection Following Repair of Achilles Tendon Rupture (아킬레스 건 파열의 봉합 후 발생한 심부 감염의 치료)

  • Lee, Woo-Chun;Kim, Yu-Mi;Ko, Han-Suk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.168-172
    • /
    • 2006
  • Purpose: Theaim of this study was to review the results of treatment for deep infection following repair of Achilles tendon rupture using reverse sural arterialized flap and/or flexor hallucis longus transfer. Materials and Methods: Five cases of Achilles tendon infection in five patients were treated using reverse sural arterialized flap and/or flexor hallucis longus transfer at our hospital with followed up of average 23.6 months (range, 13-43 months). Three patients were male and average age at surgery was 52.0 years (range, 42-59 years). Clinical results were evaluated by the method of Percy and Conochie, and the isokinetic peak torque value was interpreted according to the guideline of Sapega. Results: The clinical result was excellent in three cases, good in one case and fair in one case. The isometric peak torque value for $30^{\circ}$ per second was normal in two cases, possibly abnormal in one case, and probably abnormal in two cases, and for $120^{\circ}$, normal in one case, probably abnormal in four cases. Five cases in five patients were satisfied with the result of treatment. Conclusion: We can expect satisfactory results of treatment for deep infection following repair of Achilles tendon rupture using reverse sural arterialized flap and/or flexor hallucis longus transfer.

  • PDF

Effects of surface treatment on the osseointegration potential of orthodontic mini-implant (분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구)

  • Jeon, Mi-Sun;Kang, Yoon-Goo;Mo, Sung-Seo;Lee, Keun-Bye;Kook, Yoon-Ah;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • Objective: The purpose of this study was to compare the torque resistance to removal of sandblasted large grit and acid etched (SLA) surface treated orthodontic mini-implants and smooth surface orthodontic mini-implants as well as performing histologic observations. Methods: Two groups of custom screw shaped orthodontic mini-implants (C-implant, 1.8 mm outer diameter $\times$ 9.5 mm length, Cimplant, Seoul, Korea) were designated. 22 SLA treated C-implants (SLA group) and 22 machined surface C-implants (machined group) were placed in the tibia metaphysis of 11 adult New Zealand white rabbits. Following a 6-week healing period, the rabbits were sacrificed. Subsequently, the C-implants were removed under reverse torque rotation with a digital torque measuring device and independent t-test was performed. Selected tissues were prepared for histologic observation. Results: The SLA group presented a higher mean removal torque value (6.286 Ncm) than the machined group (4.491 Ncm) which was statistically significant (p < 0.005). Histologic observation revealed a trend of more new bone formation in contact with the screw surface in the SLA group than the smooth group. Conclusions: The results of this study suggested that SLA surface treatment can enhance the osseintegration potential for C-orthodontic mini-implants.

Effect of Implant Designs on Insertion Torque and Stress : Three-Dimensional Finite Element Analysis (임플란트 디자인이 식립 회전력과 응력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Kim, Jang-Eung;Choi, Yu-Sung;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.205-220
    • /
    • 2010
  • Purpose : To analyze the effect of implant designs on insertion torque and stress by performing a comparative study on von Mises stress, torque and normal force through a three-dimensional finite element analysis. Materials and methods : Models of the screw type implant were used to model the implant as a form placed in the mandibular premolar region applying a three-dimensional finite element method. Screw type implant designs were classified into 4 types of parallel ones and 7 types of tapered ones. Other factors were simulated to represent clinical environment. Results : In parallel implant designs, higher and wider threads resulted in higher insertion torques and higher stress distributions. In tapered implant designs, changes in the taper led to remarkable differences in the insertion torques. It was difficult to determine a certain tendency of stress distribution around the implants since the stress level was too high around them. In tapered implant designs, smaller implants demonstrated lower insertion torques than the original type and were relatively less dependent on the degree of taper. Tapered implants showed higher insertion torques and higher stress distributions than parallel implants. Conclusion : According to this study, although the tapered implant demonstrated a higher insertion torque than the parallel implant, stress tended to be concentrated in the entire fixture of the tapered implant due to the inefficient stress distribution.

THE STUDY ON THE REMOVAL TORQUE OF THE DIAMOND LIKE CARBON COATED TITANIUM ABUTMENT SCREWS (DLC 표면 처리에 따른 임플랜트 지대주 나사의 풀림 현상에 관한 연구)

  • Koak Jai-Young;Heo Seong-Joo;Chang Ik-Tae;Yim Soon-Ho;Lee Jong-Yeop;Lee Kwang-Ryeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.128-135
    • /
    • 2003
  • Statement of problem : Implant screw loosening remains a problem in implant prosthodontics. Some abutment screws with treated surfaces were introduced to prevent screw loosening and to increase preload. DLC(Diamond Like Carbon) film has similar properties on hardness, wear resistance, chemical stability, biocompatibility as real diamond materials. Purpose : The purpose of this study was to investigate the effect of lubricant layer on abutment screw and to discriminate more effective method between soft lubricant and hard lubricant to prevent screw loosening. Material and method : In this study, $1{\mu}m$ thickness DLC was used as protective, lubricating layer of titanium screws and 3 times removal torque was measured on the abutment screws to investigate the difference in 10 coated and 10 non-coated abutment screws. Results : The results indicated that the implants with DLC coating group were not more resistant to the applied force in screw loosening. At 32Ncm, the 3 times removal torque in DLC group were $27.75{\pm}2.89,\;25.85{\pm}2.35$ and $26.2{\pm}2.57$. The removal torque in no-coated abutment screws were $27.85{\pm}4.23,\;27.35{\pm}2.81$ and $27.9{\pm}2.31$, respectively. Conclusion : The lubricant layer used in this study was Diamond Like Carbon(DLC) and it have a properties of hard and stable layer. The DLC coating layer was hard enough to prevent distortion of screws in the repeated unscrewing procedure in clinical situation. The reduced friction coefficient in hard DLC layer was not effective to prevent screw loosening.

Reproducibility of the Isokinetic Joint Torque as a Rotator Cuff Weakness Test Protocol in Patients With Rotator Cuff Tendinitis

  • Kim, Soo-yong;Oh, Jae-seop
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.21-29
    • /
    • 2017
  • Background: The measurement of the strength of the shoulder muscles is an important element of the overall assessment of patients with various shoulder disorders. However, the clinical utilization of this measurement is dependent on its reproducibility. Objects: To explore the reproducibility of the measurements derived from testing of the isokinetic strength of shoulder muscles in patients with tendinitis of the rotator cuff. Methods: A total of 20 patients with tendinitis of the rotator cuff participated in this study and were assessed twice in 1 week. Isokinetic testing was performed concentrically for shoulder flexors, abductors, and external rotators and eccentrically for the shoulder extensors, adductors, and internal rotators. The relative and absolute reproducibility of the peak torque (PT) and ratios were assessed using intra-class correlation coefficients (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID), respectively. Results: Overall, high to excellent ICC, clinically acceptable SEM and MCID values were obtained for the PT (ICC: .83-.95, SEM: 1.2%-9%, MCID: 3.4%-25%) and ratios (ICC: .85-.93, SEM: 5.1%-10%, MCID: 14.2%-27.6%). Conclusion: These findings suggest that isokinetic tests may be effectively utilized for the determination of shoulder strength profiles and appropriate position are recommended to perform test without pain in patients with tendinitis of the rotator cuff.

Biologic stability of plasma ion-implanted miniscrews

  • Cho, Young-Chae;Cha, Jung-Yul;Hwang, Chung-Ju;Park, Young-Chel;Jung, Han-Sung;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.43 no.3
    • /
    • pp.120-126
    • /
    • 2013
  • Objective: To gain basic information regarding the biologic stability of plasma ion-implanted miniscrews and their potential clinical applications. Methods: Sixteen plasma ion-implanted and 16 sandblasted and acid-etched (SLA) miniscrews were bilaterally inserted in the mandibles of 4 beagles (2 miniscrews of each type per quadrant). Then, 250 - 300 gm of force from Ni-Ti coil springs was applied for 2 different periods: 12 weeks on one side and 3 weeks contralaterally. Thereafter, the animals were sacrificed and mandibular specimens including the miniscrews were collected. The insertion torque and mobility were compared between the groups. The bone-implant contact and bone volume ratio were calculated within 800 mm of the miniscrews and compared between the loading periods. The number of osteoblasts was also quantified. The measurements were expressed as percentages and analyzed by independent t-tests (p < 0.05). Results: No significant differences in any of the analyzed parameters were noted between the groups. Conclusions: The preliminary findings indicate that plasma ion-implanted miniscrews have similar biologic characteristics to SLA miniscrews in terms of insertion torque, mobility, bone-implant contact rate, and bone volume rate.

Stability of implant screw joint (임플란트 나사의 안정성)

  • Chung, Chae-Heon;Kwak, Jong-Ha;Jang, Doo-IK
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

Comparative Analysis between Zirconia Implant and Titanium Implant

  • Hwang, Ho-Jeong;Kim, Seong-Kyun;Lee, Joo-Hee;Heo, Seong-Joo;Koak, Jai-Young;Yoo, Soo-Yeon
    • Journal of Korean Dental Science
    • /
    • v.5 no.2
    • /
    • pp.48-53
    • /
    • 2012
  • Various ceramic implant systems made of yttria-stabilized tetragonal zirconia polycystal (Y-TZP) have become commercially available in recent years. A search of the literature was performed to assess the clinical success of dental Y-TZP implants and whether the osseointegration of Y-TZP is comparable to that of titanium, the standard implant material. No controlled clinical studies in humans regarding clinical outcomes or osseointegration could be identified. Clinical data were restricted to case studies and case series. Only 7 animal studies were found. Osseointegration was evaluated at 4 weeks to 24 months after placement in different animal models, sites and under different loading conditions. The mean bone-implant contact percentage was above 60% in almost all experimental groups. In studies that used titanium implants as a control, Y-TZP implants were comparable to or even better than titanium implants. Surface modifications may further improve initial bone healing and resistance to removal torque. Y-TZP implants may have the potential to become an alternative to titanium implants but cannot currently be recommended for routine clinical use, as no long-term clinical data are available.