References
- de Bruijn JD, Klein CP, de Groot K, van Blitterswijk CA. The ultrastructure of the bone-hydroxyapatite interface in vitro. J Biomed Mater Res. 1992; 26: 1365-82. https://doi.org/10.1002/jbm.820261008
- Kay JF. Calcium phosphate coatings for dental implants. Current status and future potential. Dent Clin North Am. 1992; 36: 1-18.
- Dubruille JH, Viguier E, Le Naour G, Dubruille MT, Auriol M, Le Charpentier Y. Evaluation of combinations of titanium, zirconia, and alumina implants with 2 bone fillers in the dog. Int J Oral Maxillofac Implants. 1999; 14: 271-7.
- Schultze-Mosgau S, Schliephake H, Radespiel- Tröger M, Neukam FW. Osseointegration of endodontic endosseous cones: zirconium oxide vs titanium. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000; 89: 91-8. https://doi.org/10.1016/S1079-2104(00)80022-0
- Scarano A, Di Carlo F, Quaranta M, Piattelli A. Bone response to zirconia ceramic implants: an experimental study in rabbits. J Oral Implantol. 2003; 29: 8-12. https://doi.org/10.1563/1548-1336(2003)029<0008:BRTZCI>2.3.CO;2
- Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modifi ed zirconia implants: a histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res. 2005; 7(suppl 1): S13-20. https://doi.org/10.1111/j.1708-8208.2005.tb00070.x
- Akagawa Y, Ichikawa Y, Nikai H, Tsuru H. Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. J Prosthet Dent. 1993; 69: 599- 604. https://doi.org/10.1016/0022-3913(93)90289-Z
- Akagawa Y, Hosokawa R, Sato Y, Kamayama K. Comparison between freestanding and toothconnected partially stabilized zirconia implants after two years' function in monkeys: a clinical and histologic study. J Prosthet Dent. 1998; 80: 551-8. https://doi.org/10.1016/S0022-3913(98)70031-9
- Kohal RJ, Weng D, Bächle M, Strub JR. Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment. J Periodontol. 2004; 75: 1262-8. https://doi.org/10.1902/jop.2004.75.9.1262
- Albrektsson T, Eriksson AR, Friberg B, Lekholm U, Lindahl L, Nevins M, Oikarinen V, Roos J, Sennerby L, Astrand P. Histologic investigations on 33 retrieved Nobelpharma implants. Clin Mater. 1993; 12: 1-9. https://doi.org/10.1016/0267-6605(93)90021-X
- Davies JE. Mechanisms of endosseous integration. Int J Prosthodont. 1998; 11: 391-401.
- Albrektsson T, Wennerberg A. Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont. 2004; 17: 536-43.
- Albrektsson T, Wennerberg A. Oral implant surfaces: Part 2--review focusing on clinical knowledge of different surfaces. Int J Prosthodont. 2004; 17: 544-64.
- Hao L, Lawrence J, Chian KS. Osteoblast cell adhesion on a laser modified zirconia based bioceramic. J Mater Sci Mater Med. 2005; 16: 719- 26. https://doi.org/10.1007/s10856-005-2608-3
- Hanawa T, Kamiura Y, Yamamoto S, Kohgo T, Amemiya A, Ukai H, Murakami K, Asaoka K. Early bone formation around calcium-ionimplanted titanium inserted into rat tibia. J Biomed Mater Res. 1997; 36: 131-6. https://doi.org/10.1002/(SICI)1097-4636(199707)36:1<131::AID-JBM16>3.0.CO;2-L
- Aldini NN, Fini M, Giavaresi G, Martini L, Dubini B, Ponzi Bossi MG, Rustichelli F, Krajewski A, Ravaglioli A, Mazzocchi M, Giardino R. Osteointegration of bioactive glass-coated and uncoated zirconia in osteopenic bone: an in vivo experimental study. J Biomed Mater Res A. 2004; 68: 264-72.
- Blaschke C, Volz U. Soft and hard tissue response to zirconium dioxide dental implants--a clinical study in man. Neuro Endocrinol Lett. 2006; 27 (suppl 1): 69-72.
- Luthardt RG, Holzhüter MS, Rudolph H, Herold V, Walter MH. CAD/CAM-machining effects on Y-TZP zirconia. Dent Mater. 2004; 20: 655-62. https://doi.org/10.1016/j.dental.2003.08.007
- Luthardt RG, Holzhüter M, Sandkuhl O, Herold V, Schnapp JD, Kuhlisch E, Walter M. Reliability and properties of ground Y-TZP-zirconia ceramics. J Dent Res. 2002; 81: 487-91. https://doi.org/10.1177/154405910208100711
- Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater. 1999; 15: 426-33. https://doi.org/10.1016/S0109-5641(99)00070-6
- Chevalier J. What future for zirconia as a biomaterial? Biomaterials. 2006; 27: 535-43. https://doi.org/10.1016/j.biomaterials.2005.07.034
- Tinschert J, Natt G, Mohrbotter N, Spiekermann H, Schulze KA. Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations. J Biomed Mater Res B Appl Biomater. 2007; 80: 317- 21.