Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments (고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향)

  • Kwon, Hyuk-chul
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.

A Study on the Dyeing of PTT(polytrimethylene terephthalate)/Silk Mixture Fabrics with Disperse Dyes/Acid Dyes (분산염료/산성염료에 의한 PTT(polytrimethylene terephthalate)/견 교직물의 염색에 관한 연구)

  • Sung, Woo-Kyung
    • The Korean Fashion and Textile Research Journal
    • /
    • v.12 no.1
    • /
    • pp.94-102
    • /
    • 2010
  • The dyeing of poly(trimethylene terephthalate)(PTT)/silk mixture fabrics can be accomplished by a two bath dyeing method with separate application of the disperse dyes on the PTT, reduction cleaning of the stained silk and then dyeing the silk with the acid dyes, or by one bath dyeing method with mixed dye ranges, possibly followed by a cleaning treatment. The two bath dyeing method has the advantage of better results with respect to dry cleaning fastness properties thanks to the possibility of an intermediate reduction clear. On the other hand, as compared with the two bath dyeing method, one bath dyeing method with a mixed dye range permits rapid and more reproducible dyeing, without the risk of great difference with respect to the shade of the strike on both substrates as well as savings of time, energy and water usage. This study was carried out to investigate dyeing characteristics of PTT/silk mixture fabrics with disperse dyes/acid dyes by one bath dyeing method in comparison with two bath dyeing method in the interests for rationalization of the dyeing process.

A Study on Formulation of Surfactant-free Aqueous Cleaning agents and Evaluation of Their Physical Properties and Cleaning Ability (계면활성제 무첨가 세정제의 배합 및 물성/세정성 평가 연구)

  • Lee, Jae Ryoung;Yoon, Hee Keun;Lee, Min Jae;Bae, Jae Heum;Bae, Soo Jeong;Lee, Ho Yeoul;Kim, Jong Hee
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • Environment-friendly and surfactant-free aqueous cleaning agents have been developed in order to solve various problems generated by surfactants in the aqueous cleaning agents. Aqueous surfactant-free cleaning agents, S-1 and S-2 have been formulated with water-soluble solvents such as propylene glycol and propylene glycol ether on their main components and with some additives. These solvents were chosen because of their good solubility in water and excellent solubility of fluxes which are major contaminants of printed circuit board in the electronic industry. Physical properties of the formulated and the imported cleaning agents were measured to predict their cleaning performance, and their cleaning abilities of flux and solder contaminants were evaluated under the various ultrasonic frequencies by a gravimetric method. The measurement results show that the physical properties of cleaning agent V are generally similar with those of formulated cleaning agents S-1 and S-2. Both the cleaning agent V and the formulated cleaning agents S-1 and S-2 showed similar trends that their pH decrease in the beginning and then increases later on with the increase of their dilution in water. It is considered that the wetting indices of the cleaning agents calculated with experimental values do not not have any influence on their cleaning ability. In ultrasonic cleaning tests under three ultrasonic frequencies of 28, 45, and 100 kHz, their best performances of cleaning solder and flux were obtained at 45 kHz and 28 kHz, respectively, and the cleaning performance of the formulated cleaning agents S-1 and S-2 was better than that of the cleaning agent V. However, in the case of the recommended diluted concentration of 25 wt% cleaning solution, the cleaning performance of the cleaner V for solder and flux was better in the initial stage of cleaning compared to the formulated cleaners. And it may be concluded that the formulated cleaning agents S-1 and S-2 can be applied to cleaning of solder and flux in the industry, based on the experimental results in this study.

A study for the Conservation about the Armor of General Jung, Choong Sin and the Chinese Phoenix-Patterned Military uniform in $IHYUJ\breve{O}NG$ (정충신 장군 갑옷과 위산 이휴정 소장 봉황문단 직영포에 실시한 보존처리연구)

  • Bai, Sang Kyoung
    • Journal of Conservation Science
    • /
    • v.3 no.1 s.3
    • /
    • pp.23-30
    • /
    • 1994
  • This thesis researched for the conservation of a suit of armor that General Jung, Choong Sin had been worn in the 17th century, and of military uniform that was in perfect condition even though it had been underground for over 300years since 1676. As the armor was made with silk and cotton, it was treated by the dry cleaning method and the mild charge system. In the dry cleaning method, the used solvents were n-hexane and n-decane. And the percentage of the dry soap was 2 in the mild charge system. As the military uniform was made with only silk, it was treated by the dry cleaning method through the solvent of n-hexane and n-decane. Armor was repaired by scoured hemp partially, but military uniform became too deteriorated seriously to repair.

  • PDF

A Selection of the Optimal Working Condition for an Outer-hull Preprocessing Robot Using a Taguchi Method (다구찌 방법을 이용한 선체 외판 전처리 로봇의 최적 작업 조건 선정)

  • Chung Won-Jee;Kim Ki-Jung;Kim Hyo-Gon;Kim Jung-Hyun;Kim Ho-Kyung;Lee Hun-Dong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.4
    • /
    • pp.69-73
    • /
    • 2006
  • This paper present the optimal cleaning condition of the out-hull preprocessing robot by Taguchi method in design of experiments. A $L_8(2^4)$ orthogonal array is adopted to study the effect of adjustment parameters. The adjustment parameters consist of robot speed, motor torque, motor speed and tool angle. And the quality feature is selected as surface roughness of sheet metal. Taguchi analysis is performed in order to evaluate the effect of adjustment parameters of the quality feature of cleaning process by $Minitab^{(R)}$.

Improved Yaw-angle Estimation Filter as a Function of the Actual Maneuvers for a Cleaning Robot (주행조건 식별을 이용한 로봇청소기의 진행각 추정을 위한 향상된 필터설계)

  • Cho, Yoon Hee;Lee, Sang Cheol;Hong, Sung Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.6
    • /
    • pp.470-476
    • /
    • 2016
  • This paper proposes a practical algorithm for the reduction of measurement errors due to drift in a micro-electromechanical system (MEMS) gyros that are used for a mobile robot. Any drift in a MEMS gyro will cause an unbounded growth of errors in the estimation of heading, which makes it nearly useless in applications that require high accuracy over a long operating time. In proposed method, maneuvers of a cleaning robot are observed through encoders' measurement process and a decision to correct bias drift will be made if necessary. The method used in this paper is called the "heading estimation filter". To evaluate the accuracy of the proposed method, a comparison was made between the estimation of the heading of the cleaning robot and one from a motion capture system.

Synthesis and Evaluation of Ecofriendly Nontoxic Cleaning Agents (무독성 친환경 세정제의 합성 및 평가에 관한 연구)

  • Kim, Jong Cheon;Ryu, Young;Hong, Yeon Heui;Kim, Seok Chan
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.548-551
    • /
    • 2014
  • In order to reduce toxicity on the human body, four new cleaning agents (1-4) containing ester and ether functionalities have been invented. The synthesized cleaning agents's physical properties, biodegradabilities, and $LD_{50}$ values, which were conducted by Korea Testing Certification Institute by using standard method, showed excellent values. A specimen for cleaning ability was prepared by cutting in $60{\times}40mm$ size of stainless steel plate. The surface of the above specimens was treated with four different kinds of contaminants, such as cutting oil, anti-rust oil, drawing oil, and lubricating oil. Contaminated specimens were then immersed in compounds (1-4) for 1 to 5 minutes to dissolve oil in the cleaning agent. The data indicate that all compounds (1-4) exhibit good cleaning ability toward four contaminant oils. It is also confirmed that these compounds can be applicable to various industrial cleaning fields as nontoxic and biodegradable cleaning agents because of their excellent biodegradabilities and $LD_{50}$ values.

Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes (상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구)

  • Seo, Jeewon;Lee, Gyusang;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.

A Study on the Antibacteria Effect and the Properties Change by Treatment of Chrome-Tanned Garment Leathers. -On the Changes by Dry Cleaning- (의류용 크롬유혁의 가공처리에 따른 항미생물효과 및 특성변화에 관한 연구 -드라이클리닝에 의한 변화를 중심으로-)

  • Cho, Seung-Shick;Sim, Mi-Sook;Kim, Un-Bae
    • Textile Coloration and Finishing
    • /
    • v.3 no.2
    • /
    • pp.10-15
    • /
    • 1991
  • This study was to examine the anti-bacteria effect and the changes of chemical properties of chrome-tanned garment leathers on the preservative treatment. Various test methods, such as investigation of preservative treatment process, resistance test and chemical analysis by cleaning, antbbacterial test by shake flask method are carried out in this study. The results can be obtained as follows: 1. Bacterial reduction percentage of chrome-tanned garment leathers on the preservative treatment was 28.6%. 2. In the antbbacterial effect by dry cleaning, preservative treated leathers has no resistance. 3. Fats content has been removed by dry cleaning using perchloroethylene, so garment leathers properties were altered. 4. PH value was changed by dry cleaning. But once after fats removing, it was changed the little by dry cleaning numbers.

  • PDF

Comparison of Filtration Resistances according to Membrane Cleaning Methods (막표면의 케이크층 세정 방법에 따른 여과 저항값 비교)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.817-827
    • /
    • 2016
  • The resistance in series model has been frequently used for determination of various filtration resistance to correctly understand the membrane fouling behaviour in MBR (membrane bio-reactor) for wastewater treatment. The cake layer resistance ($R_c$) which is commonly determined by calculation of flux dataset that are obtained empirically before and after removing the cake layer on membrane surface. However, the calculated Rc values are very dependent on the cleaning methods adapted for removal of cake layer. This study investigated how the various cleaning options affect $R_c$. Seven different cleaning methods were employed: i) ultrasonication (100 W, 10 min), ii) ultrasonication (200 W, 60 min), iii) ultrasonication (400 W, 120 min), iv) water rinsing in a shaker (100 rpm, 10 min), v) water rinsing in a shaker (300 rpm, 60 min), vi) water rinsing, vii) sponge scrubbing. For the hydrophilic PES membrane, the cake layer removal efficiencies ranged from 64% to 10%, indicating that the removal of cake layer was highly dependent on the cleaning options. For the hydrophobic PVDF membrane, the cake layer removal efficiencies ranged from 79% to 97%. Consequently, a standardized method for cake layer removal to determine cake resistance ($R_c$) is needed for correct interpretation of the fouling phenomena.