Sterilizing and Deodorizing Effect of UV-Ray Air Cleaner for Refrigerator (자외선(紫外線) 공기(空氣) 청정기(淸淨機)의 냉장고(冷藏庫) 살균(殺菌) 탈취(脫臭) 효과(效果))

  • Chun, Jae-Kun;Lee, Yung-Jin;Kim, Kyung-Man;Lee, Hong-Won;Jang, Eu-Yung
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.174-177
    • /
    • 1993
  • Ultara violet ray air cleaner to use as the sterilization and deodorization device in refrigerator was designed and made of UV lamp and carbon block as the main components. The intensity of the lamp was $2.38\;mW/cm^2$ and reflector was installed to increase the radation. After running the device for 12 hours, 80% of the population of airborn bacteria was sterilized both at 48 and 480 liter refrigerator chambers. Ozone production caused by UV-ray reached 0.082 ppm at holding section within a few second when the device was operated at $25^{\circ}C$ and it showed 0.06 pm at $3^{\circ}C$. Deodorization effect was 2.5 times greater than that of a device made of electrical are principle at $25^{\circ}C$. New device 2 times more effectivly decreased trimethylamine and methyl mercaptan content applied as odor indicator substance in chamber at $3^{\circ}C$ than electrical arc type.

  • PDF

Characteristics of a Wet Air Cleaning System for Removal of Air Pollutants (습식 공기청정장치의 공기오염물질 제거 특성)

  • Bae, Gwi-Nam;Kim, Yong Pyo;Baik, Nam Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2000
  • Performance characteristics of a wet air cleaning system were investigated experimentally, and discussed in relation with physicochemical properties of the target pollutants. The system is composed of an air cleaner, a separator, and a medium filter. Removal efficiency of the system was measured for ambient particles and gaseous air pollutants: $SO_2$, NO, $NO_2$, HCHO, and $NH_3$. For particle removal test, particles were introduced into the system through a fan, and the particle size distribution was measured at three locations by using two laser particle counters. Particle removal efficiency for each system component was obtained from the particle size distribution. It was found that the separator primarily removed coarse particles greater than $5{\mu}m$ in diameter, and that the medium filter mainly removed fine particles less than $5{\mu}m$ in diameter. For gas removal test, air with gaseous air pollutant was injected into the outlet of the fan, and the concentration was measured both at the upstream of the air cleaner and at the downstream of the separator. It was found that the gaseous species with high Henry's law coefficients, such as $SO_2$, HCHO, and $NH_3$, showed high removal efficiency, but the gaseous species with low Henry's law coefficients, such as NO and $NO_2$, showed low removal efficiencies. It was also found that negative ions were generated from the air cleaner.

  • PDF

A Development of Home Mess-Cleanup Robot with Entertainment Function

  • Kim, Seung-Woo;Cha, Hyun-Koo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1444-1447
    • /
    • 2004
  • The vacuum-cleaner had made the burden of house chore lighten but the operation labour of a vacuum-cleaner had been so severe. Recently, the cleaning robot was producted to perfectly solve the cleaning labour of a house but it also was not successful because it still had a problem of mess-cleaning, which is the clean-up of big trash and the arrangement of newspapers, clothes, etc. The cleaning robot is to just vacuum dust and small trash and has no function to arrange and take away before the automatic vacuum-cleaning. For this reason, the market for the cleaning robot is not yet built up. So, we need a design method and technological algorithm of new automatic machine to solve the problem of mess-cleanup in house. In this paper, a Home Mess-Cleanup Robot(HMR), which has a practical function of the automatic mess-cleanup, is developed. It need functions of agile automatic navigation, novel manipulation system for mess-cleanup. The automatic navigation system has to be controlled for the full scanning of living room, to recognize the absolute position and orientation of the self, the precise tracking of the desired path, and to distinguish the mess object to clean-up from obstacle object to just avoid. The manipulation system, which is not needed in the vacuum-cleaning robot, must have the functions, how to distinguish big trash to clean from mess objects to arrange, how to grasp in according to the form of mess objects, how to move to the destination in according to mess objects and arrange them. Then, it should be an intelligent system so that the mess cleaning task can be autonomously performed in a wide variety of situations and environments. It need to also has the entertainment functions for the good communication between the human and HMR. Therefore, the Home Mess-cleanup Robot with Entertainmental Human Interface is developed in this paper. Finally, the good performance of the designed machine, HMR'4, is confirmed through the results of the mess clean-up and arrangement.

  • PDF

Numerical Study on the Internal Flow in the Cyclone Vacuum Cleaner (사이클론 청소기 내부 유동에 관한 수치해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.283-289
    • /
    • 2014
  • General household vacuum cleaners consist of dust collector, pre filter, motor and exhaust filter, and the filtered clean air is discharged to the atmosphere. By using the CFD methods, we estimated the internal flow in two types of commercial cyclone vacuum cleaners to evaluate the dust collection performance. From the analysis, it was known that the number of revolution had higher values in cyclone cone region. CFD analysis in a specific showed non-uniform velocity distribution at outlet, which results in the deterioration of particle collection performance. In order to improve flow condition, the installation of baffle was proposed and the values of velocity RMS were estimated.

A Study on Improving Environmental Characteristics of Cyclone Vacuum Cleaner using Life Cycle Assessment (LCA 평가를 이용한 싸이클론 진공청소기의 친환경성 개선방안에 관한 연구)

  • Hwang, Bo-Seok;Yoon, Yong-Han;Lee, Chanhyun;Yi, Hwa-Cho
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.241-250
    • /
    • 2014
  • In this study, performance and environmental characteristics of cyclone vacuum cleaners are analyzed and product improvement methods are investigated to minimize environmental effect of the cleaners using the result. A simplified LCA method is used to analyze environmental characteristics of the cyclone vacuum cleaners. Two cyclone vacuum cleaners with similar specifications are chosen for the experiment. Typical characteristics of cyclone vacuum cleaners such as energy consumption, suction force, noise and temperature are measured and compared. Most environmental effect was caused by the energy consumption in use phase of life cycle. Some ideas are created to reduce energy consumption of the vacuum cleaners in use phase like installing baffle, and methods to extend exchange period of filter. It is analyzed how recyclability rate of vacuum cleaners could be improved to reduce the environmental effect in whole life of the vacuum cleaners.

Automatic Feeding Bottle Washing Machine Usability Evaluation : Infant Product (자동 젖병 세척기 사용성평가 : 영유아 제품)

  • Park, Hye Jin;Kim, Jong Geun;Lee, Seok Jae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.507-514
    • /
    • 2022
  • This study is to compare and analyze the evaluation of cleaning cleanliness and usability according to the muscle activity and cleaning method in the wrist rotation motion when using a bottle washer for women with childbirth experience. To this end, when using an automatic bottle washer and a manual bottle washer, the muscle activity and cleaning cleanliness of the forearm muscles were quantitatively evaluated using equipment, and the effects of variables were analyzed and the following conclusions were obtained. First, it was found that the muscle activity was lower than that of the automatic baby bottle cleaner when using a manual bottle cleaner. Second, the cleanliness was judged to be the best in automatic washing (forward + reverse direction), followed by automatic washing (forward direction) and manual washing. Third, the usability evaluation of the use of the baby bottle washing machine showed higher satisfaction than that of the automatic baby bottle washing machine. Through these conclusions, this study can be used as basic data for product advancement in the future by proving the effectiveness of using an automatic bottle washer.

BLDC Motor Design for Vacuum Cleaner Using Soft Magnetic Composite (연자성 철심재질을 이용한 진공 청소기용 BLDC 전동기 설계)

  • Lee, Kyu-Seok;Cha, Hyun-Rok;Yun, Cheol-Ho;Jung, Tae-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.795-796
    • /
    • 2006
  • 본 논문은 청소기용 BLDC 전동기 모터에 기존의 전기강관이 아닌 SMC(Soft Magnetic Composite)를 적용하여 진공청소기용 BLDC 전동기 모터 설계를 하는데 있다. 본 논문에서 사용한 SMC는 순철 분말에 전기적 절연 코팅을 실시한 새로운 재질로 현재 많은 연구가 진행 되고 있는 분야이다. 그러나 재질의 특성에 적합한 모터 설계에 관한 연구는 미진 하였다. 따라서 본 연구는 진공청소기용으로 많이 사용되는 BLDC 모터에 SMC를 적용 하였을 때 BLDC 전동기의 특성을 알아 보고자 하였다. 본 연구에서 SMC재질을 사용 할 때는 어느 조건에서 사용함이 유리한지 알 수 있었다. 또한 고속 청소기에 적합한 설계를 실시한 결과 SMC 재질의 낮은 투자율로 말미암아 인덕턴스가 감소하고, 전류가 높아져, 출력 증대 되는 것으로 나타 났다. 향 후 본 연구는 SMC를 이용한 BLDC 모터 설계 시 설계 기준으로 이용 될 수 있을 것으로 사료된다.

  • PDF

Fabrication of Cores for the Injection Mould with a High Cooling Rate and Injection Molding Using the Fabricated Core (고속 냉각 특성을 가진 사출성형 금형 코어 제작 및 사출 성형)

  • Ahn, D.G,
    • Transactions of Materials Processing
    • /
    • v.16 no.7
    • /
    • pp.549-554
    • /
    • 2007
  • The objective of this paper is to investigate into the fabrication technology of cores for the injection mould with three-dimensional conformal cooling channels to reduce the cooling time. The location of the conformal cooling channels has been determined through the injection molding analysis. The mould has been manufactured from a hybrid rapid tooling technology, which is combined a direct metal rapid tooling with a machining process. Several injection molding experiments have been performed to examine the productivity and the validity of the designed mould. From the results of the experiments, it has been shown that the proposed mould can mold a final product within a cooling time of 3 seconds and a cycle time of 21 seconds, respectively.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer (무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석)

  • Oh, I.H.;Lee, J.H.;Lee, K.H.;Lee, J.H.;Lee, D.S.;Eo, S.M.;Lee, M.L.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.