• Title/Summary/Keyword: Circulating water

Search Result 466, Processing Time 0.031 seconds

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

Differential Functions of Caffeine and Ascorbic Acid in $\gamma-Irradiated$ Male Mice

  • Kim Ji Hyang;Chun Ki-Jung;Yoon Yang Dal;Kim Jin Kyu
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.4
    • /
    • pp.398-404
    • /
    • 2005
  • Radioprotection is of practical importance for the normal tissues of tumor patients subject to radiotherapy, people with planned or accidental exposure to radiation, and the public and radiation workers. Since oxygen enhances radiation - induced biological damage, antioxidants should be related with the function as a radioprotectors. Ascorbic acid or caffeine is an essential component and antioxidant in the diet of humans and a small range of other mammals. The present study investigates functional radioprotection of caffeine and ascorbic acid against gamma radiation in irradiated C57BL/6N mice. Eight-week-old male C57BL/6N mice were irradiated with 6.5 Gy. A caffeine treated group was administered with $80mg\;kg^{-1}$ body weight by intraperitoneal injection, a single treatment 1 hr before irradiation. Ascorbic acid was administered $330\;mg\;L^{-1}$ in drinking water through all the experimental period. According to time schedules, animals were sacrificed by cervical dislocation. And the samples were collected 2 weeks after whole- body gamma irradiation. The caffeine treated group showed lower decrement of body and organ weights than the other experimental groups. The qualitative analysis of circulating testosterone in serum was performed by means of radioimmunoassay (RIA). The normal level of circulating testosterone was maintained by the treatment of caffeine and ascorbic acid. The change of weight of body and organ and the appearance of seminiferous tubules were improved by an effect of caffeine or ascorbic acid against irradiation. Taken together, caffeine and ascorbic acid protects impairment of spermatogenesis against gamma radiation and may act as a radio-protector.

Identification of Major Fungi and Bacterial Species in Solid Medium Drainage for Circulating Hydroponics System (수경재배 배액 재이용을 위한 주요 곰팡이 및 박테리아 종 파악)

  • Lee, Donggwan;Son, Jinkwan;Kang, Taegyeong;Jang, Jaekyung;Park, Minjung;Lee, Taeseok;Lim, Ryugap
    • Journal of Environmental Science International
    • /
    • v.29 no.11
    • /
    • pp.1109-1123
    • /
    • 2020
  • In this study, the amount of harmful fungi and bacteria contained in the drainage and culture medium from the paprika hydroponic facility is identified. In addition, by proposing the necessity of effective purification of discharged drainage, this study attempted to confirm the possibility of drainage reuse. Finally, this study provides basic data on the basis for calculating the need for purification facilities in the future, as well as improvements in horticulture facility for sustainable agriculture. As a result of the analysis, a total of 12 types of fungi were detected in paprika medium and 10 types of fungi were detected in the drainage, and their densities were 130 and 68, respectively. Among the fungi detected in the media and drainage of the paprika hydroponic facility, the fungi with the highest detection frequency are Fusarium, Phytophthora, and Pythium. In the case of bacteria, a total of 2 types of bacteria were detected in the paprika facilities, and the density was 28 and 23, respectively. Therefore, in order to reuse the drainage and settle the circulating hydroponic cultivation system, a water treatment process capable of appropriate treatment is required.

TiO2 Reuse and Recovery from the Photocatalytic Oxidation of Cu(II)-EDTA using TiO2/UV-A System (TiO2/UV-A 시스템을 이용한 Cu(II)-EDTA의 광촉매 산화반응에서 TiO2 재사용 및 회수)

  • Lee, Seung-Mok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.84-91
    • /
    • 2005
  • $TiO_2-catalyst$ suspensions work efficiently in Photocatalytic oxidation (PCO) for wastewater treatment. Nevertheless, once photocatalysis is completed, separation of the catalyst from solution becomes the main problem. The PCO of Cu(II)-EDTA was studied to determine the reusability of the titanium dioxide catalyst. Aqueous solutions of $10^{-4}M$ Cu(II)-EDTA were treated using illuminated $TiO_2$ particles at pH 6 in a circulating reactor. $TiO_2$ was reused in PCO system for treatment of Cu(II)-EDTA comparing two procedures: reuse of water and $TiO_2$ and reuse of the entire suspension after PCO of Cu(II)-EDTA. The results are as follows; (i) Photocatalytic efficiency worsens with successive runs when catalyst and water are reused without separation and filtration, whereas, when $TiO_2$ is separated from water, the reused $TiO_2$ is not deactivated. (ii) The $TiO_2$ mean recovery (%) with reused $TiO_2$ was 86.4%(1.73g/L). Although the mean initial degradation rate of Cu(II)-EDTA and Cu(II) was lower than that using fresh $TiO_2$, there was no significant change in the rate during the course of the three-trial experiment. It is suggested that Cu(II)-EDTA could be effectively treated using an recycling procedure of PCO and catalyst recovery. (iii) However, without $TiO_2$ separation, the loss of efficiency of the PCO in the use of water and $TiO_2$ due to Cu(II), DOC remained from previous degradation and Cu(II)-EDTA added to the same suspension was observed after 2 trials, and resulted in the inhibition of the Cu(II)-EDTA, Cu(II) and DOC destruction.

Performance of Natural Circulation Hot Water System with Flat-Plate Solar Collectors (평만형 태양열 집열기 를 설치한 자연 순환식 급탕시스템 의 성능 에 관한 연구)

  • 윤석범;전문헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.579-589
    • /
    • 1985
  • The storage tank of the natural-circulation-solar-hot-water system equipped with flat-plate solar collectors is located at higher elevation than the solar collectors. Therefore, the heat loss from the system due to a reversed flow during the night-time is an important factor as well as the day-time thermal performance of the system. The thermal performance of the natural-circulation-solar-hot-water system with flat-plate solar collectors during the day-time depends mainly on the heat collecting efficiency of the solar collectors, whereas its thermal performance during the night-time depends on the system configuration , such as the elevation of the water storage tank with respect to the solar collectors and the piping connections between the storage tank and the solar collectors, as well as thermo-physical properties of the circulating fluid. In the present work, a computer program has been developed to simulate a typical natural-circulation-solar-hot-water-system, and a series of simulation tests have been carried out with the computer program to examine the thermal performance of the system during the day-time as well as the hight-time. In addition , a series of experiment have been conducted under a real sun condition using a natural-circulation-solar-hot-water-system constructed and installed at the KAIST building to compare with the results obtained from computer simulations.

The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구)

  • Lee, Dong-Won;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.

On Flow Charactistics around Special Rudders by PIV Measurement; Flapped and Water-blowing Rudder (PIV 계측에 의한 특수타 주위의 유동특성에 대하여; 플랩러더와 물분사러더)

  • Gim, Oxoc
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.2
    • /
    • pp.200-207
    • /
    • 2017
  • The purpose in having a control surface on ships is to control the motion of the ship. The control surface may be composed entirely of a single movable surface or of a combination of fixed and movable portions. A control surface has one sole function to perform in meeting its purpose, and that is to develop a control force in consequence of its orientation and movement relative to the water. The forces and moments generated as a result of this rotation and angle of attack then determine the manoeuvring characteristics of the ship. In this paper, two-dimensional flow characteristics of a flapped rudder and a water-blowing control rudder were accomplished respectively by PIV method in a circulating water channel. Model test has been carried out with different angles of attack of main foil (NACA 0012) and flap's deflection angles to predict the performance of the flapped rudder and the water-blowing control rudder. The 2-frame particle tracking method has been used to obtain the velocity distribution in the flow field. $Re{\fallingdotseq}3.0{\times}10^4$ has been used during the whole experiments and measured results have been compared with each other.

Urban Streams' Water Quality and Odor Control Using Pure Oxygen and Vortex Aerator (순산소와 Vortex Aerator를 이용한 도심하천의 수질 및 악취 관리)

  • Yoon, Dain;Choi, Mijeong;Park, Sunghyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2021
  • The target site, Goejeongcheon flows through downtown of Saha-gu, Busan and it connects to the Nakdong-gang estuary. But non-point pollutants and sewage sludge are partially flowing into the stream and deposited. As a result, dissolved oxygen concentrations of the stream were observed close to the anaerobic condition. Multistage Vortex Aerator was applied for restoring this urban stream. It dissolves oxygen by repeatedly causing collisions between water and oxygen by vortex flow. The changes in water quality and odor were monitored for 2 months while circulating 1 m3/min of water with 22 ppm dissolved oxygen. As a result of the operation, the dissolved oxygen was improved from slightly Bad (4)~Bad (5) to Good (1b)~Normal (3) grade, and the total phosphorus concentration was decreased by 76 % on average. In the case of complex odor, a maximum reduction of 84.5 % was observed on the day the entire river was anaerobic. Through this study, we evaluated the feasibility of applying pure oxygen and Vortex Aerator for the the stream restoration. It is expected that the results of this study can be used for full-scale design.

Experimental Study on the Power Generation of a Thermoelectric Module with Temperature Difference and Load Resistance (온도차 및 부하 저항에 따른 열전모듈의 발전 특성 분석)

  • Lee, Kong-Hoon;Kim, Ook-Joong;Koh, Deuk-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1942-1947
    • /
    • 2007
  • A thermoelectric module can be used for cooling or power generation. The basic requirements to achieve a significant thermoelectric performance are the same for both generators and coolers. Thermoelectric modules with $Bi_2Te_3$ materials are usually employed in the cooling applications below room temperature but it can also be used for the power generation in the similar temperature range. In the present study, the power generation with a $Bi_2Te_3$ thermoelectric module has been investigated. The temperature difference between the hot and cold sides of the module is maintained with electric heater and cold water from the circulating water bath. The result shows that the electric current generated increases with temperature difference and decreases with the load resistance. However, the voltage increases with both the temperature difference and load resistance. The electric power increases with temperature difference and it has the maximum value when the load resistance is about 4 ${\Omega}$ for a given device.

  • PDF

A Study of Flow Pattern around the Two-Dimensional Dual Subsea Pipeline on Sea Bottom (해저면에 설치된 2차원 복합해저관로 주위의 유동특성에 관한 실험적 연구)

  • 나인삼;조철희;정우철;김두홍
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.122-127
    • /
    • 2001
  • As pipelines are often used to transport gas, oil, water and oil products, there are more than one pipeline installed in the offshore field. The size and space of pipelines are various depending on the design specifications. The pipelines are to be designed and installed to secure the stability to external loads during the installation and operation period. The flow patterns are very complex around the pipelines being dependent on incoming flow velocity, pipelines size and space. To investigate the flow patterns, number of experiment are conducted with visualization equipment in a circulating water channel. The flow motion and trajectory were recorded from the laser reflected particles by camera. From the experiment the flow patterns around spaced pipelines were obtained. Also pressure gradient was measured by mano-meter to estimate the hydrodynamic forces on the behind pipeline. The results show that the various sizes and spaces can be affected in the estimation of external load. The complex flow patterns and pressure gradients can be effectively used in the understanding of flow motion and pressure gradient.

  • PDF