• Title/Summary/Keyword: Circular Arc

Search Result 164, Processing Time 0.028 seconds

Design of UWB Antenna with Fork-type structure and circular patch (원형 패치와 포크형 구조가 결합된 UWB 안테나)

  • Ha, Yun-Sang;Kim, Gi-Rae;Choi, Young-Kyu;Yun, Joong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1837-1844
    • /
    • 2016
  • This paper proposes an antenna of the fork type structure that operates in the UWB (Ultra Wide Band) frequency band (3.1 ~ 10.6 GHz). The proposed antenna is attached a circular patch in order to obtain the UWB band characteristics to the fork-type patch antenna. The ground plane is implemented in a arc-shape configuration. The effect of various parameters of the modified fork type radiating patch and partial arc ground plane for UWB operation is investigated. The proposed antenna is made of $34.0{\times}50.0{\times}1.0mm^3$ and is fabricated on the permittivity 4.4 FR-4 substrate. The experiment results shown that the proposed antenna obtained the -10 dB impedance bandwidth 8200 MHz (2.7 ~ 10.9 GHz) covering the UWB bands. This result satisfied the characteristics of ultra-wideband and the proposed antenna will be applicable to an ultra wideband system.

Defect Detection Using Focused Lamb Waves Generated by Laser (집속형 레이저 유도초음파에 의한 결함검출)

  • Kim, Hong-Joon;Jung, Ji-Hong;Ha, Job;Jhang, Kyung-Young
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.774-779
    • /
    • 2003
  • Arc-shaped line array slits have been used for the laser generation of focused Lamb waves. The spatially expanded Nd:YAG pulse laser was illuminated through the arc-shaped line array slit on the surface of a sample plate to generate the Lamb waves of the same pattern as the slit. Then the generated Lamb waves were focused at the point of which distance from the slit position is dependent on the curvature of slit arc. The proposed method showed better spatial resolution than the conventional linear array slit in the detection of laser machined linear defect and drill machined circular defect on aluminum plates of 1mm thickness.

  • PDF

Fluid Flow in a Circular Cylinder Subject to Circulatory Oscillation-Theoretical Analysis (회전요동하는 원통내의 유동특성 - 이론적 해석)

  • Seo,Yong-Gwon;Kim, Hyeon-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.3960-3969
    • /
    • 1996
  • A fluid flow inside a circular cylinder subject to horizontal and circular oscillation is analyzed theoretically. Under the assumption of small-amplitude oscillation, the governing equations take linear forms. The velocity field is obtained in terms of the first kind of Bessel function of order 1. It was found that a particle describes an orbit close to a circle in the central region and an arc near the side wall. We also obtained the Stokes' drift velocity induced by the traveling wave along the circumferential direction. The Eulerian streaming velocities at the edge of the bottom and side boundary layers were also obtained. It was shown that the vertical component of the steady streaming velocity on the side wall is almost proportional to the amplitude of the free surface motion.

NC 공작기계 컨투어 운동 정도의 해석

  • 박준호
    • Journal of the KSME
    • /
    • v.32 no.5
    • /
    • pp.441-455
    • /
    • 1992
  • NC 공작기계의 운동정밀도는 키네마틱 트랜스듀서 링크 컨투어 측정시스템(Kinematic transducer link contour measuring system), BDD 측정시스템, Circular Test 등에 의해 측정될 수 있으며, 오차 발생원인을 규명할 수 있다. 이 글에서는 NC 공작기계의 오차가 컨투어 시험 결과에 미치는 영향을 평가하기 위하여, 공칭원(nominal circle) 혹은 공칭호(nominal arc)로부 터의 반경방향 편위를 포함하는 컨투어 운동결과를 이론적으로 해석하였다.

  • PDF

DISCRETE CURVATURE BASED ON AREA

  • Park, Kyeong-Su
    • Honam Mathematical Journal
    • /
    • v.32 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • The concept of discrete curvature is a discretization of the curvature. Many literatures introduce discrete curvatures derived from arc length of circular arcs. We propose a new concept of discrete curvature of a polygon at each vertex, which is derived from area of fan shapes. We estimate the error of the discrete curvature and compare the discrete curvature with old one.

Pulsatile Flow Analyses of Newtonian Fluid and Non-Newtonian Pluid in Circular Tube (원관내 뉴턴유체와 비뉴턴유체의 맥동유동특성)

  • Cho, Min-Tae;Roh, Hyung-Woon;Suh, Sang-Ho;Kim, Jae-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1585-1596
    • /
    • 2002
  • The objectives of the present study are to numerically and experimentally investigate the steady and pulsatile flow phenomena in the circular tubes, to quantitatively compare the flow characteristics of Newtonian and non-Newtonian fluids, and to find meaningful hemodynamic information through the flow analysis in the human blood vessels. The particle image velocimetry is adopted to visualize the flow fields in the circular tube. and the results from the particle image velocimetry are used to validate the results of the numerical analysis. In order to investigate the blood flow phenomena in the circular tube. constitutive equations, which are suitable to describe the rheological properties of the non-Newtonian fluids. are determined, and the steady and pulsatile momentum equations are solved by the finite volume prediction. The velocity vectors of the steady and pulsatile flow in the circular tube obtained by the particle image velocimetry arc in good agreement with those by the numerical analysis. For the given mass flow rate. the axial velocity profiles of the Newtonian and the non-Newtonian fluids appear differently. The pulsatile flow phenomena of the Newtonian and the non-Newtonian fluids are quite different from those of the steady flow.

Separation of Isochromatics and Isoclinics from Photoelastic Fringes in a Circular Disk by Phase Measuring Technique

  • Baek, Tae-Hyun;Kim, Myung-Soo;Yoshihau Morimoto;Motoharu Fujigaki
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.175-181
    • /
    • 2002
  • A new polariscope system involving two rotating optical elements and a digital camera for whole field fringe analysis allows automated data to be acquired quickly and efficiently. The developed phase measuring technique that uses eight images through a circular polariscope is presented for the digital measurement of isochromatics and isoclinics, respectively, from photoelastic fringes in a circular disk under diametric compression. Isochromatics can directly be obtained using wrapped isoclinic phases calculated by the arc tangent operator which is the four-quadrant operator from -$\pi$ to $\pi$. It is not required to unwrap isoclinic phases for the calculations of isochromatics. Unwrapped isoclinics are directly determined from isochromatic parameters. Distributions of digitally determined isoclinics are in close agreement to manual measurements. The errors which would appear in unwrapping process of isoclinics can be avoided in the determination of isochromatics.

Reconfigurable Circularly Polarized Microstrip Antenna on a Slotted Ground

  • Yoon, Won-Sang;Han, Sang-Min;Pyo, Seong-Min;Lee, Jae-Hoon;Shin, In-Chul;Kim, Young-Sik
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.468-471
    • /
    • 2010
  • A compact square patch antenna with reconfigurable circular polarization (CP) at 2.4 GHz is proposed. Circular polarization is generated by an arc-shaped slot on the ground plane. In order to switch the CP orientation, the current flow direction of the patch is reconfigured via the PIN diodes mounted on the slot. As the slot and bias circuit are not placed on the patch side, the proposed antenna radiates a CP wave without alteration in the main beam direction. From the experimental results, the impedance and CP bandwidths of the proposed antenna have been demonstrated for up to 80 MHz and 25 MHz, respectively.