검색결과 63건 처리시간 0.024초

교통사고 조사 및 재현에서 신형 전자식운행기록계의 신뢰성에 관한 연구 (Study on Reliability of New Digital Tachograph for Traffic Accident Investigation and Reconstruction)

  • 박종진;조건우;박종찬
    • 한국자동차공학회논문집
    • /
    • 제23권6호
    • /
    • pp.615-622
    • /
    • 2015
  • Recently Digital-TachoGraph(DTG) was mounted mandatorily in commercial vehicles(Taxi, Bus, etc.). DTG records accurate and detailed information of the running state of vehicles related to traffic accident, such as Time, Distance, Velocity, RPM, Brake ON/OFF, GPS, Azimuth, Acceleration. Thus those standardized data can play an important role in traffic accident investigation and reconstruction. To develope the accurate and objective method using the DTG data for the reconstruction of traffic accident, we had conducted several tests such as driving test, high speed circuit test, braking test, slalom test at Korea Automobile Testing & Research Institute(KATRI), and collision test at Korea Automobile insurance repair Research and Training center(KART) with the vehicle equipped with several DTG. Development of the program which enables the reading and analysis of the DTG data was followed. In the experiments, we have found velocity error, RPM error, brake signal error and azimuth error in several products, and also non-continuous event data. The cause of these errors was deduced to be related to the correction factor, the durability of electronic parts and the algorithm.

부산도시철도 1호선 전동차 Low Pass Filter 개발연구 (A Study on the Development of Low Pass Filter for Chopper Gate Control Unit of Electric Rolling Stock)

  • 강현철;김해창;박희철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1445-1456
    • /
    • 2011
  • 부산도시철도 추진장치를 종합 제어하는 Chopper Gate Control Unit는 다수의 전자 전기부품, PCB, 전원공급기, 게이트회로증폭기, 프레온가스냉각기, 보호회로 등으로 구성되어 있는 주요장치로서 일본 미씨비시에서 생산된 제품을 사용하고 있다. 최근에는 초퍼장치의 고장 및 시험기 에러가 자주 발생하여 원인분석 결과 Chopper Gate Control Unit內 LPF(Lower Pass Filter)의 장기사용(약25년)으로 인한 노후화와 성능저하가 주요 원인이었음을 밝혀내고 물품구매를 위해 제작사에 문의 하였으나 이미 생산이 중단된 제품으로 별도 주문 제작시에는 고가의 비용이 발생한다. LPF는 몰딩처리가 되어있는 부품으로 수선이 불가하여 자체기술력으로 연구 개발하여 현재 부산도시철도 1호선 전동차에 13set를 적용하여 운영하고 있다. 본 논문에서는 연산 증폭기(OP Amp)와 저항, 콘덴서 등의 조합으로 자체개발한 능동필터인 Active LPF의 특성분석, 회로해석 및 설계, 다기능분석기, 스펙트럼분석기, 오실로스코프 등을 이용한 파형특성과 PS Pice 시뮬레이션 시험결과 등 개발에 관한 연구내용을 다루었다.

  • PDF

고효율 LED를 이용한 유도등의 원격제어에 관한 연구 (A Study on the Remote Control for Exit Sign Using High Efficiency LED)

  • 백동현;홍석표
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2002
  • 유도등은 일정한 조도를 가지고 상용전원에 의하여 항상 점등되어 있어야 함으로 전력소비 및 광원 교체등 경제적 손실과 관리상의 문제가 있게 된다. 본 논문은 이제까지 광원으로 사용하고 있던 형광등이나 백열전구 대신에 소비전력이 적은 고효율 발광다이오드를 사용하여 전력소비의 절감과, 점검시의 문제점을 개선하기 위해 원격제어가 가능한 새로운 유도등회로를 제안하고 실험한 것이다. 그 결과 원격제어 스위치에 의한 유도등 점검을 제어각의 범위에서 쉽게 제어할 수 있었으며 반응시간은 600〔$\mu$s〕로 매우 빠르게 동작하였다. 또한 출력 상승시간(Rise time)과 하강고시간(Fall time)은 최대 200〔ns〕로 예민하게 반응하였다. 광원으로 고효율 발광다이오드를 사용함으로 광원을 교체해야 하는등의 문제를 제거하였으며 전력소비를 감소시킬 수 있음을 확인하였다.

쉘터의 태양열 복사에 의한 열전달 특성에 관한 연구 (A Study on Heat-transfer Characteristics the Shelter by Solar-heat Radiant)

  • 심동혁;노경호;박진용;임영택
    • 한국시뮬레이션학회논문지
    • /
    • 제27권2호
    • /
    • pp.25-33
    • /
    • 2018
  • 군용 장비 개발 시 운용자가 안정적인 환경에서 운용할 수 있도록 온도조건을 고려하여 설계하여야 한다. 각종 군용 장비를 보관하는 쉘터는 다양한 환경에서 운용되고 있다. 시험장비 및 수리부속품의 저장온도 및 운용 요구조건은 $-32^{\circ}C{\sim}50^{\circ}C$로 쉘터 내부는 저장온도 및 운용 요구조건을 충족할 수 있도록 설계되어야 한다. 본 연구에서는 MIL-STD-810G의 기준을 고려하여 고온 및 태양열 조건에서 군에서 운용중인 2.5톤의 군용쉘터의 열해석을 수행하였다. 열해석은 열저항 및 열회로개념을 활용하여 적용하였으며 해석결과를 검증하기 위해 실제 제작된 군용쉘터에 대한 태양열 시험을 실시하여 결과를 비교하여 제시하였다.

고전압 착자기에서의 누전 사고 방지를 위한 광통신 제어시스템의 도입 방안과 경제성 분석 (Economic Analysis of Optical Communication Control System in High Voltage Magnetizer)

  • 배영우;김우주;홍준석
    • Journal of Information Technology Applications and Management
    • /
    • 제26권6호
    • /
    • pp.103-117
    • /
    • 2019
  • Demand for high power motors is rapidly increasing as the 4th industry and convergence technology has recently emerged. In order to produce high-strength permanent magnets, the magnets used for magnetization have been increased from DC 300V in the 1970s to DC 2.5kV in the 2010s, Up to DC 10kV in the 2030s, It is expected that higher voltage will be used to magnetize. However, in the case of a magnetizer using an existing electric signal control device, it is necessary to use a control device with a high-voltage insulation function in case a high voltage used for magnetization is leaked to the control device. If a short circuit accident occurs, the controller must be shut down and serious problems such as excessive repair costs arise. In this study, a control system adopting optical communication method instead of electric signal control method is proposed to prevent leakage currents in high-voltage magnetizer. We design a transmitter(Tx) and a receiver(Rx) device for the optical communication control device and implemented a prototype connecting the optical cable. In order to demonstrate the utility of high-voltage magnetizer using the optical communication control device, we analyzed the initial cost and the yearly cost for the years to analyze the net present value. As a result, In the case of the low-voltage magnetizer, the electric signal control method cost less, As the operating voltage of the magnetizer becomes higher. It is confirmed that it takes less cost when the optical communication control device is used.

해안매립 신도시의 재해 예방관리 네트워크 비젼 (Network vision of disaster prevention management for seashore reclaimed u-City)

  • 안상로
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.117-129
    • /
    • 2009
  • This paper studied the safety management network system of infrastructure which constructed smart sensors, closed-circuit television(CCTV) and monitoring system. This safety management of infrastructure applied to bridge, cut slop and tunnel, embankment etc. The system applied to technologies of standardization guidelines, data acquirement technologies, data analysis and judgment technologies, system integration setup technology, and IT technologies. It was constructed safety management network system of various infrastructure to improve efficient management and operation for many infrastructure. Integrated safety management network system of infrastructure consisted of the real-time structural health monitoring system of each infrastructure, integrated control center, measured data transmission using i of tet web-based, collecting data using sf ver, early alarm system which the dangerous event of infrastructure occurred. Integrated control center consisted of conference room, control room to manage and analysis the data, server room to present the measured data and to collect the raw data. Early alarm system proposed realization of warning and response within 5 minute or less through development of sensor-based progress report and propagation automation system using the media such as MMS, VMS, EMS, FMS, SMS and web services of report and propagation. Based on this, the most effective u-Infrastructure Safety Management System is expected to be stably established at a less cost, thus making people's life more comfortable. Information obtained from such systems could be useful for maintenance or structural safety evaluation of existing structures, rapid evaluation of conditions of damaged structures after an earthquake, estimation of residual life of structures, repair and retrofitting of structures, maintenance, management or rehabilitation of historical structures.

  • PDF

펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정 (Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.111-116
    • /
    • 2022
  • 전동기 소손의 원인으로는 과부하, 결상, 구속, 층간단락, 권선의 지락, 순간과전압의 유입, 회전자가 고정자에 닿는 경우 등 절연파괴로 이어져 고장 또는 전기 사고로 이어지고 있다. 따라서 기기 고장은 기기의 보수/수리에 필요한 비용에 의한 손실뿐만 아니라, 전동기가 포함된 공정 자체를 멈추기 때문에 공정 정지에 따른 생산성 저하에 의한 막대한 경제적 손실을 초래한다. 전동기의 고장을 진단하기 위한 현재의 기술의 수준은 진동, 열, 전력분석 방식을 이용하고 있지만, 고장에 따른 상당 부분의 시간이 진행되어야 문제점을 분석할 수 있는 한계점을 가지고 있다. 따라서 본 논문에서는 이러한 문제점을 해결하고자 DC AMP 신호를 이용하여 절연저항을 측정하는 장치 및 알고리즘을 산업용 전동기에 적용하여 절연저항 상태값을 추종하여 기존방식에서 해결되지 못한 전동기의 열화 및 고장 진단을 제안한다.

스탠포드 A형 대동맥 박리증 수술 후 수술 사망과 뇌손상의 위험인자 분석 (Risk Factor Analysis for Operative Death and Brain Injury after Surgery of Stanford Type A Aortic Dissection)

  • 김재현;오삼세;이창하;백만종;황성욱;이철;임홍국;나찬영
    • Journal of Chest Surgery
    • /
    • 제39권4호
    • /
    • pp.289-297
    • /
    • 2006
  • 서론: 스탠포드 A형 대동맥 박리증은 수술 사망률과 술 후 뇌손상의 발병률이 높은 질환이다. 본 연구는 지난 10년간 본원에서 시행한 A형 대동맥 박리증 수술의 성적을 분석하여 수술 사망과 뇌손상에 대한 위험인자를 알아보고자 하였다. 대상 및 방법: 1995년 2월부터 2005년 1월까지 A형 대동맥 박리증으로 수술을 시행 받은 111명의 환자를 후향적으로 분석하였다. 급성 A형 대동맥 박리증은 99예였고 만성인 경우가 12예였다. 수술 사망과 뇌손상에 대한 위험인자를 알아내기 위해 수술 전 및 수술 중 변수들에 대한 단변량 및 다변량 분석을 시행하였다. 결과: 수술 사망은 6예(5.4%)가 발생하였다. 영구적 뇌손상은 8예(7.2%), 일시적 뇌손상은 4예(3.6%)가 발생하였다. 1년, 5년, 7년 생존율은 각각 94.4, 86.3, 81.5%였다. 수술 사망에 대한 위험인자로는 III형 대동맥 박리 과거력, 응급 수술, 내막파열점이 대동맥궁에 위치한 경우, 완전 순환정지 시간 45분 이상인 경우가 단변량 분석에서 의미있게 나타났으며 다변량 분석에서는 III형 대동맥 박리 과거력(대응비 52.2), 완전 순환정지 시간 45분 이상(대응비 12.6)이 A형 대동맥 박리증의 수술 사망에 대한 위험인자였다. 뇌손상에 대한 위험인자는 병적 비만(대응비 12.9)과 대동맥궁 완전치환술(대응비 8.5)이 다변량 분석에서 통계적으로 의미있게 나타났다. 결론: A형 대동맥 박리증 수술의 성적은 수술 사망률, 뇌손상 발생률, 만기 생존율 등을 고려할 때 양호하였다. 수술 사망의 위험이 높은 것으로 나타난 III형 대동맥 박리 과거력이 있는 환자는 수술시 각별한 주의를 요하며 완전 순환정지 시간을 줄이기 위한 노력이 필요하다. 병적 비만 환자나 대동맥궁 완전치환술을 시행해야 하는 경우는 뇌손상의 발생 가능성에 특히 유념해야 한다.침착이 관찰되었고, 3개월 이후에는 글루타르알데하이드로 처치한 이식편의 내피세포층이 더 조밀하게 잘 배열되어 있었다. 결론: 글루타르알데하이드로 처리한 자가심낭을 이용한 소구경 동맥이식편이 신선한 자가심낭으로 만든 이식편보다 혈액접촉면에 내피세포 형성이 잘 되고, 콜라젠층이 더 늦게 분절됨을 발견하였다. 그러나 이러한 차이가 개통성에 영향을 줄 정도로 유의한 것인가에 대해서는 향후 추가의 연구가 필요하리라 사료된다. 오염균의 증식이나 교차오염 예방을 위한 철저한 관리는 필요한 것으로 판단되었다.시 포함하여야 한다. 이를 통해 수많은 EPID 영상들을 자동화 처리하고 오차분석을 시행함으로써 각 병원의 임상적용 방법 및 환경에 따라 상이하게 나타날 수 있는 오차의 크기를 감안한 적절한 PTV마진을 구하는데 도움을 얻을 수 있다. 이러한 장치들은 또한 최소의 노력으로 환자 치료를 관찰할 수 있는 귀중한 정보를 제공해 준다.옆핵과 중격핵은 변연계통회로(limbic circuit)에 속할 것으로 판정했다. 이마앞겉질은 생리적, 약리적, 신경학적 및 형태학적 근거들로 보아 바닥핵들을 통해 변연계통과 대뇌겉질 전체에 영향을 미칠 것으로 여겨지는데, 본 실험에서는 네 종류의 바닥핵들, 즉 꼬리핵, 줄무늬체바닥핵, 중격옆핵 및 중격핵과 관련된 신경연접들을 관찰하였으며, 그 결과를 문헌 고찰한 결과 변연계통과 줄무늬체계통이 앞뇌의 바닥에 있는 신경핵들에서 형태학적 교차연결을 통해 정서와 마음의 상태를 행동과 대응으로 표현하는 중요한 신경회로가 존재함을 제안하였다.腎臟組織)에서 더많이 발생되었다. 틸라피아의 신사구체(腎絲球體)는 담수(淡水)에서 10%o의 해수(海水)로 이주된지 14일(日) 이후에 신장(腎臟)에서 수축된 것으로 나타났다. 30%o의 해수(海水)에 적응(適應)된 틸라피아의 평균 신사구체(腎絲球體)의 면적은 담수(淡水)에 적응된 개체의

TOF 완전교정술후 발생한 심실빈맥의 외과적 절제술 -치험1례보고- (Surgical Treatment of Ventricular Tachycardia After Total Correction of Tetralogy of Fallot- Report of a case)

  • 장병철;김정택
    • Journal of Chest Surgery
    • /
    • 제29권6호
    • /
    • pp.639-645
    • /
    • 1996
  • 14세 남자환자로 최근 3년간 반복된 심계항진을 주소로 내원하였다. 환자는 8년전에 TOF로 진단받고 완전교정수술을 받았다. 수술 전 심도자 검사에서 우폐동맥폐쇄와 그에 따른 우심실압력상승을 보였고 전기 생 리학검사에서는 우심실유출로의 중격부위 에서 기 원하는 회귀성 심실빈맥으로 진단되 었다 한 개의 양극성 전극을 이용한 심실외막전기도검사에서 심실빈맥의 회귀성회로는 첩포 원위부 좌측 의 심실중격쪽 심근에서 가장 빨리 나타나 시계방향으로 청포주위를 돌아 우심실유출로 우측 심근을 활 성화시키는 것으로 나타났다. 또한 64채널 심장전기도시스템을 이용한 심실심외막전기도 검사에서는 우심실유출로의 첩 포주위를 )20 msec 주기로 시계반대방향으로 회귀하는 심실빈맥을 관찰할 수도 있었 다. 수술은 우심실유출로의 첩포와 섬유화된 조직을 제거하고 우심실유출로 상연에서 폐동맥 판막륜까지 절개를 하여 회귀성 회로가 차단되도록 하였다. 폐동맥 판막륜과 심실중격사이 에는 회귀성 회로가 완전히 차단되도록 냉동병소를 만들었다. 우폐동맥이 발달되지 않아 우폐동맥재건술은 하지 못하였다. 수술후 전기생리학 검사에서는 더 이상심 퓟窄팀\ulcorner유발되지 않았다. 본 증례에서는 TOF완전교정수술후 우심실유출로 첩포와 일부 우심실 심근주위에 slow conduction지 대가 형성되고 이것에 의한 macro-reentry심실빈맥이 발생한 것으로 생각된다. 약물로서 치료되지 않을 때는 catheter ablation이나 외과적 절제를 고려해야 한다. 외과적 절제를 할 때에는 우심실유출로와 폐동 맥 판막륜사이의 심근조직손상을 최소화하면서 우심실유출로재건을 하는것이 중요하다.성 거부반응 1례, 크기불일치 에 의한 만성 이식부전증이 1례, 천식 발작에 의한 호흡부전이 1례, 지주막하출혈 1례, 체액 성 거부반응이 의심되는 경우가 1례 였다. 이상의 단기간성적을 통해 심장이식분야에서 더욱 발전을 요하며, 특히 이식공여자 및 수혜자의 선택 이나 술후 감염관리 및 체 액성거부반응치료 등에서 더욱 진전이 있어야 하겠다.07m', 동맥 혈 산소포화도는 83.0$\pm$3.8 % 이었다. 우폐동맥의 지름은 9.0$\pm$ 1.5 mm, 좌폐동맥의 지름은 7.7 $\pm$2.Omm, 폐동맥 지수는 197.3$\pm$57.1 mm2/m2, McGoon 비는 1.76$\pm$0.32 였다 수술후 전 환자에서 폐동맥 압력을 측정하였으며 평균 폐동맥 압은 12.8 $\pm$3.6mmHg이 었다. 환자의 성장에 따라 폐동맥의 지름도 증가하였으나 폐동맥 지수나 McGoon비는 증가하지 않았다. 또한 환자의 나이, 술후 동맥혈내 산소포화도의 증가 정도, 혈관 성형술 여부, 수술후 심도자 및 혈큰조 영술까지의 기간 등은 수술후의 폐동맥 지수의 증가에 영향을미치지 못하였으며 단지 수술전의 폐동맥 의 크기가 매우 작을 경우(McGoon 비 1.2 미만)에는 폐동맥 지수가 유의한 증가를 보였는데 이는 수술 \ulcorner 동반된 폐동맥 성형술등의 영향이 있었음을 감안하여야 할 것으로 생각되었다. 한편 수술전 폐동맥 크기에 대한 지표로서 폐동맥 지수(PAI)와 McGoon 비(MGR)와는 다음과 같은 유의한 상관관계가 있 음을 알 수 있었다

  • PDF

절연저항 측정 장치에 의한 지락사고 전류의 비변화 (Nonchange of Grounding Current due to Equipment Measuring Insulation Resistance)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.175-180
    • /
    • 2015
  • 산업화의 추세에 따라 수요가 급증하고 있는 고전력을 생산하기 위하여 시설장비 및 부하의 대용량화가 수반되고 있다. 전기설비의 규모는 점차 복잡해 지고, 대규모화 됨으로써 고도 정보화 사회로의 발전에 크게 기여하고 있다. 그러나, 발전 설비에서 불의의 사고가 발생하여 전기의 생산이 중단된다면, 전기에 의존하여 작동 중인 수 많은 장비가 지장을 받게 되고, 산업사회에 막대한 경제적 손실 및 장애를 초래하게 된다. 사고가 발생한 발전설비를 복구하기 위해서는 많은 시간과 비용이 소요되어 국가 산업 활동에 막대한 경제적 피해를 끼치게 된다. 사고를 미연에 방지하기 위하여 케이블의 동작 상태를 정기적으로 감시 확인하여야 하며, 우리는 절연 저항를 측정하기 위한 장비를 개발하여 (주)서부발전의 현장에 설치하여 운용 중인 바, 장비의 설치로 인한 지락 전류의 변동이 없으므로, 정확한 측정 결과를 확인할 수가 있었다. 이를 체계적 응용하여 열화 상태를 구체화하여 구현할 수 있는 사전 예방감시 기술을 연구 중에 있다.