• 제목/요약/키워드: Circuit Breaker

검색결과 689건 처리시간 0.024초

Analysis of a Gas Circuit Breaker Using the Fast Moving Least Square Reproducing Kernel Method

  • Lee, Chany;Kim, Do-Wan;Park, Sang-Hun;Kim, Hong-Kyu;Jung, Hyun-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.272-276
    • /
    • 2009
  • In this paper, the arc region of a gas circuit breaker (GCB) is analyzed using the fast moving least square reproducing kernel method (FMLSRKM) which can simultaneously calculate an approximated solution and its derivatives. For this problem, an axisymmetric and inhomogeneous formulation of the FMLSRKM is used and applied. The field distribution obtained by the FMLSRKM is compared to that of the finite element method. Then, a whole breaking period of a GCB is simulated, including analysis of the arc gas flow by finite volume fluid in the cell, and the electric field of the arc region using the FMLSRKM.

마이크로그리드를 위한 Thyristor Circuit Breaker의 구현 (Implementation of Thyristor Circuit Breaker for Microgird Applications)

  • 김진영;김슬기;김인동;노의철;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.516-517
    • /
    • 2011
  • 마이크로그리드는 분산전원 또는 계통의 Sag/Swell 및 단락사고, 지락사고 등으로 인한 정전 발생 시에 사고 지점을 제외한 독립운전이 가능해야 한다. 따라서 사고 발생지점을 신속하게 분리할 수 있는 기술이 필요하다. 이러한 배경으로 본 연구에서는 신속하게 사고지점을 차단하는 고속차단 시스템(TCB :Thyristor Circuit Breaker)을 제안한다. 도통손실이 작고 경제적인 Thyristor를 이용하여 25 [kVA]급 TCB 시스템을 제작하고 사고를 모의하여 사고 발생 시의 TCB 시스템 동작특성에 대해 연구한다.

  • PDF

차단기와 리클로져의 통신을 이용한 루프 배전계통의 보호협조 적용시 신뢰도 비교에 관한 연구 (A Study on the Comparison of Reliability for Protective Coordination of Loop Power Distributions using Communication of Circuit Breaker and Recloser)

  • 이희태;문종필
    • 전기학회논문지P
    • /
    • 제60권3호
    • /
    • pp.133-137
    • /
    • 2011
  • The purpose of smart grid is the low $CO_2$ through expansion of renewable energy. To achieve the purpose of smart grid, typical radial power distribution system will be changed to loop power distribution system. The loop power distribution system have many advantages such as low power loss, low voltage drop, and increase of connection of renewable energy. In this paper, the algorithm for minimization of interrupted section of power distribution system is proposed through communication between circuit breaker and recloser in loop power distribution system. The proposed algorithm is proved through case studies about reliability evaluation

전기화재에 따른 진공차단기의 건전성 평가 (A Study on the Evaluation of Reliability of the Vacuum Circuit Breaker for the Electrical Fire)

  • 최홍규;박준열
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.24-28
    • /
    • 2013
  • Fire-hited electrical equipment has possibility of deterioration. So its replacement is essential in terms of safety. However, the economic burden is increased. Therefore, the replacement or re-use of it is to be determined by tests. But the research of Integrity Assessment on Fire-hited electrical equipments is very rare. In this paper, we tested to determine the replacement or re-use of Fire-hited vacuum circuit breaker. And provided the data for the integrity assessment through the analysis of its deterioration.

단거리송전선에서 투입저항이 없는 차단기적용에 관한 연구 (The Study on Application of Circuit Breaker without Closing Resistor in Short Transmission Line)

  • 김정배;정영환;송원표
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권1호
    • /
    • pp.31-37
    • /
    • 2004
  • In this paper, the analysis result of the switching surge in substation including GIS(Gas Insulated Switchgear) has been described using the EMTP(Electro Magnetic Transient Program) program. After performing the modeling of the input data, we have reviewed the energization overvoltages of GCB(Gas Circuit Breaker) without closing resistor in 345kV network, according to the conditions of simultaneously operating switch and statistically operating switch. Firstly, it can be known that the energization overvoltage of single line is higher than that of parallel energized line. Secondly, the maximum energization overvoltage obtained in statistics switch is higher than one in simultaneous switch. From these results, it can be known that the phase-to-earth energization overvoltages of $\alpha$-$\beta$ section are less than 2.2 p.u when closing resistor is eliminated. Therefore, it is possible to consider the circuit breaker eliminated the closing resistor in $\alpha$-$\beta$ section.

노즐용삭을 고려한 SF6 가스차단기 노즐의 열적회복특성 해석 (Analysis of Thermal Recovery Characteristics for Nozzle of SF6 GCB Considering Nozzle Ablation)

  • 이병윤;송기동;정진교;박경엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.76-82
    • /
    • 2005
  • In this paper, a method for analyzing the thermal recovery characteristics of the nozzle of gas circuit breaker was described. In order to obtain thermal recovery characteristics, the transient simulation of SF6 arc plasma within the nozzle was carried out. In particular, the nozzle ablation was taken into account by simultaneously solving the PTFE concentration equation with the governing equations such as continuity, momentum and energy equation. After that, post arc current calculation was performed with the rate of rise of recovery voltage changed. From the calculated post arc current, it was possible to suggest the thermal recovery characteristics of the nozzle of gas circuit breaker.

Optimal Design of a Permanent Magnetic Actuator for Vacuum Circuit Breaker using FEM

  • Yoo Yong-Min;Kim Dae-Kyong;Kwon Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.92-97
    • /
    • 2006
  • This paper presents the characteristic analysis and the optimal design of a permanent magnetic actuator (PMA) for a vacuum circuit breaker (VCB) using a two-dimensional finite element analysis. The purpose of this research about a PMA is to minimize the breaking time and the volume of the permanent magnet within the limits of the holding force and maximum current in the coil. The conjugate gradient method is used as an optimization algorithm. The node moving technique is iteratively implemented until the design variables of the PMA are optimized. In this paper, the optimal design of a PMA is accomplished to improve the conventional design methods.

스프링구동 링크를 가진 기중 회로차단기의 동적 분석 (Dynamic Analysis of Air Circuit Breaker with Spring-Actuated Linkage)

  • 안길영;권병희;오일성;윤영관;최종웅
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.812-815
    • /
    • 1997
  • A dynamic model of air circuit breaker with a spring-actuated linkage is derived, and its validation for analysis and design, particularly appropriateness for an analysis of high-speed motion behavior are checked through experiments. The dynamic model is developed through the modeling process based on ADAMS and Pro/Engineer. The simulation results of derived dynamic models for the rapid closing and opening operations are compared with actual responses using a high-speed camera and investigated to validate their usefulness.

  • PDF

고속 개폐 시뮬레이션을 위한 진공 회로차단기의 동적 모델 및 해석 (Dynamic Model and Analysis of a Vacuum Circuit Breaker Mechanism for High-Speed Closing and Opening Simulations)

  • 안길영;김수현
    • 한국정밀공학회지
    • /
    • 제19권10호
    • /
    • pp.163-170
    • /
    • 2002
  • The dynamic model of a high-speed vacuum circuit breaker mechanism with spring-actuated cam and linkage is derived to simulate the high-speed closing and opening operations. Its validation for an analysis of high-speed motion behavior is checked through experiments. The characteristics of the friction on the camshaft are investigated using the nonlinear pendulum experiment. The parameters of the friction model are estimated using the optimization technique. The analysis exhibits that the friction of the pendulum depends on stick-slip, Stribeck effect and viscous damping. Comparing simulation results with actual responses using a high-speed camera, the appropriateness of derived dynamic models for the rapid closing and opening operations is shown. The spring motion, which has much influence on the closing responses, is observed.

수변전설비에서 접점 불량에 따른 열 및 전계 분포 해석 (The Analysis of Temperature and Electric Field due to Contact Failure in Power Substation)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.307-311
    • /
    • 2016
  • Although there are existing Residual Current Protective Device (RCD) including detect electric leakage and elements such as short circuit and surge, the occurrence of incidents caused by electric faults, including fire, are still constant. The purpose of this study is to analyze the causes of accidents through the electric field distribution in the interpretation of the fault contact breaker. Simulation results by the arc fault has shown the convergence of temperature and electric field to the defect. Through their simulation results, the main cause of erosion phenomena in circuit breaker bar is the electric arc by concentration of electric field not due to dissolve by temperature.