• 제목/요약/키워드: Chest Support

검색결과 268건 처리시간 0.024초

심폐소생술 시 아이젤의 고정 방법에 따른 환기량의 변화 비교: 시뮬레이션 마네킨을 이용한 연구 (Comparison of changes in ventilation volume according to fixation method of I-gel during cardiopulmonary resuscitation: a study using a simulated manikin)

  • 김선태;신상열;최정우
    • 한국응급구조학회지
    • /
    • 제25권3호
    • /
    • pp.7-16
    • /
    • 2021
  • Purpose: The I-gel device is Korea's most frequently used airway management method during pre-hospital cardiopulmonary resuscitation (CPR). This study aimed to compare changes in ventilation volume according to the fixation method with a simulated manikin. Methods: We placed I-gel into an advanced life support simulator and compared tape and band fixation conditions. CPR was performed according to the 2020 Korean CPR guidelines, using a mechanical chest compression device and an adult bag. The positional shift of I-gel and the ventilation volume of the simulated manikin were measured after performing CPR for 20 minutes. Five trials were carried out in each setting. Statistical analysis was carried out with SPSS 27.0. P < .05 was considered significant. Results: Positional shift after 20 minutes of CPR was as follows: tape fixation, 7.2 ± 0.2 mm; band fixation, no change, indicating a significant difference between the two groups (p=.003). The mean ventilation volume was tape fixation, 482.63 ± 30.84 mL; band fixation, 544.96 ± 22.98 mL, showing a significant difference (p=.002). Conclusion: When using the I-gel during pre-hospital CPR, using a band-type fixing device with elasticity rather than fixing the tape provides stable and appropriate ventilation by maintaining the fixed position.

Delayed Sternal Closure Using a Vacuum-Assisted Closure System in Adult Cardiac Surgery

  • Hyun Ah Lim;Jinwon Shin;Min Seop Jo;Yong Jin Chang;Deog Gon Cho;Hyung Tae Sim
    • Journal of Chest Surgery
    • /
    • 제56권3호
    • /
    • pp.206-212
    • /
    • 2023
  • Background: Delayed sternal closure (DSC) is a useful option for patients with intractable bleeding and hemodynamic instability due to prolonged cardiopulmonary bypass and a preoperative bleeding tendency. Vacuum-assisted closure (VAC) has been widely used for sternal wound problems, but only rarely for DSC, and its efficacy for mediastinal drainage immediately after cardiac surgery has not been well established. Therefore, we evaluated the usefulness of DSC using VAC in adult cardiac surgery. Methods: We analyzed 33 patients who underwent DSC using VAC from January 2017 to July 2022. After packing sterile gauze around the heart surface and great vessels, VAC was applied directly without sternal self-retaining retractors and mediastinal drain tubes. Results: Twenty-one patients (63.6%) underwent emergency surgery for conditions including type A acute aortic dissection (n=13), and 8 patients (24.2%) received postoperative extracorporeal membrane oxygenation support. Intractable bleeding (n=25) was the most common reason for an open sternum. The median duration of open sternum was 2 days (interquartile range [25th-75th pertentiles], 2-3.25 days) and 9 patients underwent VAC application more than once. The overall in-hospital mortality rate was 27.3%. Superficial wound problems occurred in 10 patients (30.3%), and there were no deep sternal wound infections. Conclusion: For patients with an open sternum, VAC alone, which is effective for mediastinal drainage and cardiac decompression, had an acceptable superficial wound infection rate and no deep sternal wound infections. In adult cardiac surgery, DSC using VAC may be useful in patients with intractable bleeding or unstable hemodynamics with myocardial edema.

Surgical Outcomes of Centrifugal Continuous-Flow Implantable Left Ventricular Assist Devices: Heartmate 3 versus Heartware Ventricular Assist Device

  • Kinam Shin;Won Chul Cho;Nara Shin;Hong Rae Kim;Min-Seok Kim;Cheol Hyun Chung;Sung-Ho Jung
    • Journal of Chest Surgery
    • /
    • 제57권2호
    • /
    • pp.184-194
    • /
    • 2024
  • Background: Left ventricular assist devices (LVADs) are widely employed as a therapeutic option for end-stage heart failure. We evaluated the outcomes associated with centrifugal-flow LVAD implantation, comparing 2 device models: the Heartmate 3 (HM3) and the Heartware Ventricular Assist Device (HVAD). Methods: Data were collected from patients who underwent LVAD implantation between June 1, 2015 and December 31, 2022. We analyzed overall survival, first rehospitalization, and early, late, and LVAD-related complications. Results: In total, 74 patients underwent LVAD implantation, with 42 receiving the HM3 and 32 the HVAD. A mild Interagency Registry for Mechanically Assisted Circulatory Support score was more common among HM3 than HVAD recipients (p=0.006), and patients receiving the HM3 exhibited lower rates of preoperative ventilator use (p=0.010) and extracorporeal membrane oxygenation (p=0.039). The overall early mortality rate was 5.4% (4 of 74 patients), with no significant difference between groups. Regarding early right ventricular (RV) failure, HM3 implantation was associated with a lower rate (13 of 42 [31.0%]) than HVAD implantation (18 of 32 [56.2%], p=0.051). The median rehospitalization-free period was longer for HM3 recipients (16.9 months) than HVAD recipients (5.3 months, p=0.013). Furthermore, HM3 recipients displayed a lower incidence of late hemorrhagic stroke (p=0.016). In the multivariable analysis, preoperative use of continuous renal replacement therapy (odds ratio, 22.31; p=0.002) was the only significant predictor of postoperative RV failure. Conclusion: The LVAD models (HM3 and HVAD) demonstrated comparable overall survival rates. However, the HM3 was associated with a lower risk of late hemorrhagic stroke.

Unexpected Restart Failure of Durable Left Ventricular Assist Devices: A Report of Two Cases

  • Hyo Won Seo;Ga Hee Jeong;Sung Min Kim;Minjung Bak;Darae Kim;Jin-Oh Choi;Kiick Sung;Yang Hyun Cho
    • Journal of Chest Surgery
    • /
    • 제57권3호
    • /
    • pp.315-318
    • /
    • 2024
  • The HeartWare Ventricular Assist Device (HVAD) was widely used for mechanical circulatory support in patients with end-stage heart failure. However, there have been reports of a critical issue with HVAD pumps failing to restart, or experiencing delays in restarting, after being stopped. This case report describes 2 instances of HVAD failure-to-restart during heart transplantation surgery and routine outpatient care. Despite multiple attempts to restart the pump using various controllers and extensions, the HVAD failed to restart, triggering a hazard alarm for pump stoppage. In one case, the patient survived after receiving a heart transplantation, while in the other, the patient died immediately following the controller exchange. These cases highlight the rare but life-threatening complication of HVAD failure-to-restart, underscoring the importance of awareness among clinicians, patients, and caregivers, and adherence to the manufacturer's guidelines and recommendations for HVAD management.

Evaluation of accuracies of genomic predictions for body conformation traits in Korean Holstein

  • Md Azizul Haque;Mohammad Zahangir Alam;Asif Iqbal;Yun Mi Lee;Chang Gwon Dang;Jong Joo Kim
    • Animal Bioscience
    • /
    • 제37권4호
    • /
    • pp.555-566
    • /
    • 2024
  • Objective: This study aimed to assess the genetic parameters and accuracy of genomic predictions for twenty-four linear body conformation traits and overall conformation scores in Korean Holstein dairy cows. Methods: A dataset of 2,206 Korean Holsteins was collected, and genotyping was performed using the Illumina Bovine 50K single nucleotide polymorphism (SNP) chip. The traits investigated included body traits (stature, height at front end, chest width, body depth, angularity, body condition score, and locomotion), rump traits (rump angle, rump width, and loin strength), feet and leg traits (rear leg set, rear leg rear view, foot angle, heel depth, and bone quality), udder traits (udder depth, udder texture, udder support, fore udder attachment, front teat placement, front teat length, rear udder height, rear udder width, and rear teat placement), and overall conformation score. Accuracy of genomic predictions was assessed using the single-trait animal model genomic best linear unbiased prediction method implemented in the ASReml-SA v4.2 software. Results: Heritability estimates ranged from 0.10 to 0.50 for body traits, 0.21 to 0.35 for rump traits, 0.13 to 0.29 for feet and leg traits, and 0.05 to 0.46 for udder traits. Rump traits exhibited the highest average heritability (0.29), while feet and leg traits had the lowest estimates (0.21). Accuracy of genomic predictions varied among the twenty-four linear body conformation traits, ranging from 0.26 to 0.49. The heritability and prediction accuracy of genomic estimated breeding value (GEBV) for the overall conformation score were 0.45 and 0.46, respectively. The GEBVs for body conformation traits in Korean Holstein cows had low accuracy, falling below the 50% threshold. Conclusion: The limited response to selection for body conformation traits in Korean Holsteins may be attributed to both the low heritability of these traits and the lower accuracy estimates for GEBVs. Further research is needed to enhance the accuracy of GEBVs and improve the selection response for these traits.

입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터 (General Radiography Imaging Usage and Effective Dose of Inpatients: Based on Data from Inpatients in 2018)

  • 길종원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.107-116
    • /
    • 2024
  • In this study, we analyzed the use of general radiography imaging and effective dose in inpatients. Our aim is to help reduce national medical radiation exposure doses and develop rational health-care financial policies. The effective dose for each general radiography was calculated using the ALARA-GR program for 53 types (total: 260 codes) general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2018 inpatient patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was analyzed. 89.00% of inpatients undergo general radiography imaging at least once, with an average of 12.63 scans per person and an effective dose of 1.00 mSv. Those who received support from Medical Aid showed a higher value compared to those who were insured by National Health Insurance, with 17.39 cases and 1.43 mSv (p<.001). Chest had the highest usage rate at 23.12% for general radiography imaging, while L-spine had the highest effective dose at 24.53%. It is estimated that 420 inpatients patients undergo 121 to 820 general radiography imaging procedures per year, and 233 inpatients are estimated to have an annual effective dose of >20.00~58.25 mSv. Rational use of health-care finances and the practice of medical radiation safety management are essential for the well-being of individuals, the enhancement of quality of life, and the improvement of health-care quality.

Inter-Facility Transport on Extracorporeal Life Support: Clinical Outcomes and Comparative Analysis with In-house Patients

  • Hong, Tae Hee;Lee, Heemoon;Jung, Jae Jun;Cho, Yang Hyun;Sung, Kiick;Yang, Ji-Hyuk;Lee, Young-Tak;Cho, Su Hyun
    • Journal of Chest Surgery
    • /
    • 제50권5호
    • /
    • pp.363-370
    • /
    • 2017
  • Background: Extracorporeal life support (ECLS) is widely used in refractory heart or lung failure, and the demand for inter-facility transportation on ECLS is expanding. However, little is known about post-transportation outcomes, the clinical safety of such transportation, or the characteristics of the transported patients. Methods: This was a retrospective review of a 3-year, single-institution experience with inter-facility ECLS transport, as well as a comparative analysis of clinical outcomes with those of in-house patients. We also analyzed the risk factors for hospital mortality in the entire ECLS population using univariate and multivariate analyses to investigate the effects of transport. Results: All 44 patients were safely transported without adverse events. The average travel distance was 178.7 km, with an average travel time of 74.0 minutes. Early survival of the transported group seemed to be better than that of the in-house group, but the difference was not statistically significant (70.5% vs. 56.6%, p=0.096). The incidence of complications was similar between the 2 groups, except for critical limb ischemia, which was significantly more common in the transported group than in the in-house group (25.0% vs. 8.1%, p=0.017). After adjusting for confounders, being part of the transported group was not a predictor of early death (adjusted odds ratio, 0.689; p=0.397). Conclusion: Transportation of patients on ECLS is relatively safe, and the clinical outcomes of transported patients are comparable to those of in-house ECLS patients. Although matched studies are required, our study demonstrates that transporting patients on ECLS did not increase their risk of hospital mortality after adjustment for other factors.

선원유관단체의 선원 보건의료실태 인식도 조사 (A Research on the Perception Level of Seafarer Related Organizations in Seafarer's Actual Health Care Conditions)

  • 김재호;전영우
    • 한국항해항만학회지
    • /
    • 제39권3호
    • /
    • pp.193-198
    • /
    • 2015
  • 이 연구는 선내의료 및 선원 건강관리 여건 개선 방안을 마련하기 위하여 선원 건강관리 정책에 영향을 미치는 정부를 비롯한 선원 유관단체 종사자 139명을 대상으로 선원들의 건강과 질병관리에 대한 보건의료실태에 대한 인식도 조사를 실시하였다. 조사결과 선원들의 건강관리여건(p<0.01)과 건강관리 능력(p<0.01), 현행의 무선응급의료 정책(p<0.01), 선내 의료함 및 의료장비의 도움(p<0.05) 및 선박 의료관리자 제도에 대해 유관기관 간에 인식도 차이는 있었으나 대체적으로 부정적인 응답률이 높았으며, 선원 건강관리를 위한 선내의료 지원제도 개선을 위해서는 간이 건강측정장비 비치, 정기적 건강검진 강화, 원격의료 및 건강관리를 위한 선원건강증진센터의 설치(p<0.01)가 시급히 필요하다고 조사되었다.

선천적 심질환아의 수술동의서 작성과 관련된 부모의 요구 (Needs of Parents Who have the Child with Congenital Heart Disease Related to the Informed Consent)

  • 최미영
    • 부모자녀건강학회지
    • /
    • 제6권1호
    • /
    • pp.18-30
    • /
    • 2003
  • Congenital heart disease is the most frequently shown congenital disease among children, most of them can be corrected with operation. However, Patients and their parents need nursing intervention when they face this risky incident of operation. Therefore, parents' experiences are absolutely needed to plan nursing intervention to give practical help to the patients and their parents. The purpose of this study is to provide basic resources to develop a feasible intervention program for the parents by understanding the experiences related to the informed consent of cardiac surgery of their child. From January to June 2003, 10 parents of children patients with congenital heart disease were interviewed who filled out Operation Agreement before the primary operation after they are diagnosed as congenital heart disease in pediatric chest surgery of A hospital in Seoul. They were asked to give opinion regarding pre-operation needs and the interviewed information was analyzed. The results of this study are as follows : Firstly, they were asked what they felt before they were told about the operation of their children from the doctor before filling out the informed consent of operation. They felt 1) vague, 2) confusion of choose, 3) risky, 4) resented, 5) uneasy, 6) guilty, and 7) the burden of operation. Secondly, they were asked what they felt after they filled out the informed consent of operation and the doctor gave them detailed information on the operation of their children. They felt 1) confused, 2) responsible, 3) rejected, 4) angry, 5) plain, 6) to have hope, 7) trying to trust medical people, 8) that consolation is needed, and 9) conditional reduction of the burden of operation. Thirdly, followings are the categories of congenital parents' demand before operation based on the analysis of experiences related to the preparation of the informed consent of operation. 1) Information Demand (1) Anticipatory information (2) Concrete and precise information (3) Individual information 2) Support (1) Empathy (2) Parental supporting (3) Support of parents in the same situation 3) Education and consulting (1) Children-oriented Education (2) Consultation Considering the results of this study, parents of the child with congenital heart disease seem to have various emotional experiences related to filling out the informed consent and they need concrete and practical helps before cardiac surgery. This study proposes that systematic nursing intervention is needed according to the needs of the parents who have the child with congenital heart disease before operation in the field of child health nursing.

  • PDF

Prediction Models for Solitary Pulmonary Nodules Based on Curvelet Textural Features and Clinical Parameters

  • Wang, Jing-Jing;Wu, Hai-Feng;Sun, Tao;Li, Xia;Wang, Wei;Tao, Li-Xin;Huo, Da;Lv, Ping-Xin;He, Wen;Guo, Xiu-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권10호
    • /
    • pp.6019-6023
    • /
    • 2013
  • Lung cancer, one of the leading causes of cancer-related deaths, usually appears as solitary pulmonary nodules (SPNs) which are hard to diagnose using the naked eye. In this paper, curvelet-based textural features and clinical parameters are used with three prediction models [a multilevel model, a least absolute shrinkage and selection operator (LASSO) regression method, and a support vector machine (SVM)] to improve the diagnosis of benign and malignant SPNs. Dimensionality reduction of the original curvelet-based textural features was achieved using principal component analysis. In addition, non-conditional logistical regression was used to find clinical predictors among demographic parameters and morphological features. The results showed that, combined with 11 clinical predictors, the accuracy rates using 12 principal components were higher than those using the original curvelet-based textural features. To evaluate the models, 10-fold cross validation and back substitution were applied. The results obtained, respectively, were 0.8549 and 0.9221 for the LASSO method, 0.9443 and 0.9831 for SVM, and 0.8722 and 0.9722 for the multilevel model. All in all, it was found that using curvelet-based textural features after dimensionality reduction and using clinical predictors, the highest accuracy rate was achieved with SVM. The method may be used as an auxiliary tool to differentiate between benign and malignant SPNs in CT images.