비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징 (Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 정회원;김정민;정만희;임은경
    • 대한디지털의료영상학회논문지
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향 (The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography)

  • 권순무;박창희;박정규;송운흥;정재은
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.203-210
    • /
    • 2014
  • X선을 이용한 chest radiography는 일반적으로 180 cm의 SID에서 실시되고 있다. digital chest radiography에서 AEC를 적용하고 120 kVp, 320 mA에서 SID를 180 cm부터 340 cm까지 20 cm 단위로 증가시켜 가며 영상의 질과 환자선량의 관계를 알아보았다. chest phantom 영상의 정성적인 영상평가를 위해 VGA를, 정량적인 평가를 위해 SNR을 분석하였다. 선량은 ESAK로 측정하고 effective dose는 PCXMC를 이용하였다. 연구결과 일반적으로 시행되는 SID 180 cm를 기준으로 했을 때, ESAK의 경우 240 cm, 280 cm, 320 cm에서 각각 8.7%, 11.47%, 13.56%의 유의한 감소가 있었다. effective dose의 경우 전신에 대해 2.89%, 4.67%, 6.41%의 감소, 폐에서 5.08%, 6.98%, 9.6%의 감소가 관찰되었다. SNR의 경우 각각 9.04%, 8.24%, 11.46%의 감소가 관찰되었으며 특히, SID 260 cm ~ 300 cm 구간에서 8.03%의 작은 감소가 나타났고 SID 340 cm까지도 5.24로 5이하로 감소되지 않았다. VGA에서는 통계적으로 유의한 차이가 없는 진단적 가치가 높은 영상으로 평가되었다. 따라서 eigital chest radiography에서 SID를 300 cm까지 증가시킴으로 화질의 저하 없이 환자선량을 감소시킬 수 있을 것으로 기대된다.

표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가 (Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR)

  • 김상태;한범희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.173-178
    • /
    • 2010
  • 방사선 일반촬영은 크게 두 가지 유형으로 구분할 수 있는데 디지털 영상 시스템인 CR(Computed Radiography)과 DR(Digital Radiography)이 주로 활용되고 있다. 이 둘의 차이는 선량과 영상의 질 관점에서 정의할 수 있다. 본 연구에는 피부입사선량(Entrance Skin Dose, ESD)의 관점에서 환자에게 투여된 선량을 계산하고 비교하여 CR과 DR 간의 선량 차이를 연구하기 위해 8가지의 표준 영상의학적 검사(Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP)가 고려되었다. 영상화질에 대한 평가는 진단방사선학적 영상을 위한 화질 기준에 부합하는지를 보증하기 위해 영상의학과 전문의에 의해 시행되었다. DR의 ESD는 CR의 ESD보다 낮다는 것이 확인되었다. 방사선 촬영을 담당한 방사선사가 동일인 이었고 CR과 DR의 영상 화질이 유사하거나 DR에서 조금 더 우수했기 때문에 본 연구는 고려된 검사 내에서 DR이 CR보다 선량 절감 차원에서 볼 때 더 우수한 기기라는 것을 보여준다.

진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교 (A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography)

  • 이원정;고경선;박재성;김성진;추상덕;박소영;최병순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.85-91
    • /
    • 2010
  • 분진에 노출되었던 자가 진폐소견을 갖고 있으면서 합병증이 발생하면 진폐요양기관에서 입원 치료를 받을 수 있다. 본 연구에서는 전국 33개 진폐요양기관의 실태조사 결과로부터 흉부 디지털촬영기관과 아날로그촬영 기관의 정도관리를 비교 분석 하였다. 전체 진폐요양기관 중 24개 기관은 디지털촬영을 실시하고 있었고, 9개 기관은 아날로그촬영을 실시하고 있었다. 산업안전보건연구원 특수건강진단(진폐정도관리)기관 흉부 방사선분야 평가표를 이용하여 디지털촬영 기관과 아날로그촬영기관 사이에 촬영기술 및 화질, 판독환경평가 결과를 비교하였고, 화질은 진폐판독정도관리 교육을 수료하고 진폐 판독경험이 많은 2명의 흉부 영상의학과전문의가 각각 독립적으로 평가한 후, 평균값을 사용하여 비교 하였다. 디지털촬영기관과 아날로그촬영기관 사이에 촬영장치 및 관전류, 조사시간에서는 유의한 차이를 보이지 않았지만, 관전압, 격자비에서는 유의한 차이를 보였다. 디지털촬영기관이 아날로그촬영기관보다 촬영기술과 판독환경에서 통계학적으로 유의하게 높았고, 화질에서도 높았지만 유의하지는 않았다. 따라서, 진폐요양기관이 아날로그촬영에서 디지털촬영으로 전환하게 되면 정도관리의 향상을 가져올 수 있다.

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택 (The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 김정민;임은경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.273-277
    • /
    • 2005
  • 디지털 의료 영상의 빠른 발전은 새로운 기술-비정질 평판형 측정기-에 대한 최적의 기술이 동행되지 못했다. 이번 실험으로 비정질 평판형 측정기를 사용한 흉부 방사선 영상의 대한 환자선량과 영상의 화질에 대하여 비교하였다. 모든 실험은 비정질 평판형 측정기를 사용하였다. 흉부 팬텀을 사용한 흉부 방사선영상은 관전압 $60{\sim}150\;kVp$에서 획득하였다. 이번 실험을 통하여 획득된 비정질 평판형 측정기를 사용한 X-선 에너지에 대한 영상의 질과 환자선량에 관련된 정보들을 보고한다. 이 정보는 비정질 평판형 측정기를 사용한 시스템에서 최적의 관전압의 선정에 효과적인 정보를 제공하며, 특히 일반적인 흉부 검사에 적용될 수 있을 것이다.

  • PDF

흉부 X-Ray 영상개선을 위한 신경망 적용에 관한 연구 (A Study to Apply the Neural Networks for Improvement of X-Ray Chest Image)

  • 이주원;이한욱;이종회;신태민;김영일;이건기
    • 전자공학회논문지SC
    • /
    • 제37권1호
    • /
    • pp.49-55
    • /
    • 2000
  • 흉부의 병변을 진단하기 위해 주로 사용되고 있는 흉부 X-선 촬영은 최근 컴퓨터 기술의 발달에 힘입어 디지털화 되고 있다. 디지털화된 흉부 영상을 방사선과 전문의가 모니터 상에서 관찰할 때 흉부 영상의 품질이 고르지 못하여 병변을 검출하기가 어려울 뿐만 아니라 이로 인하여 많은 진단 시간이 소요된다. 따라서 본 연구에서는 디지털 흉부 영상을 개선하기 위해 신경망을 이용하여 흉부 X-선 영상의 등화 방법을 제안하고 그 결과를 히스토그램 등화 방법과 비교하여 제시하였다.

  • PDF

흉부 디지털토모영상의 기본모드 및 부가여과사용 시 환자선량과 화질비교 (Digital Tomosynthesis Imaging of the Chest : Comparison of Patient Exposure Dose and Image Quality between Default Setting and Use Additional Filter)

  • 김계선;안성민;김성철
    • 한국콘텐츠학회논문지
    • /
    • 제13권9호
    • /
    • pp.288-294
    • /
    • 2013
  • 흉부 디지털토모장치는 가장 발달한 촬영방법중의 하나이지만 일반 흉부촬영방법에 비해 환자의 피폭선량이 높다는 단점이 있다. 이런 이유 때문에 본 연구는 흉부 디지털토모영상에서 부가여과를 사용하여 환자선량을 저감시키는 방법을 검토하여 보았으며, 화질의 변화도 실험하였다. 그 결과 부가여과가 없는 장치의 기본상태에서 피부입사선량, 면적선량, 실효선량은 1.95 mGy, 17.66 $dGycm^2$, 0.133 mSv로, 부가여과사용시는 0.312 mGy, 2.27 $dGy.cm^2$, 0.052 mSv로 나타나 선량이 각 각 66.2%, 73.6%, 57.4%로 감소하였다. 화질에서 병소의 검출율은 중심부 미소병소 검출율(p < .001)을 제외한 나머지 주변부, 중심부병변 및 주변부 미소병소에서는 두 방법에서 큰 차이를 보이지 않았으며, 환자의 선량감소에는 큰 효과를 볼 수 있었다.

Automatic Anatomically Adaptive Image Enhancement in Digital Chest Radiography

  • Kim, Sung-Hyun;Lee, Hyoung-Koo;Ho, Dong-Su;Kim, Do-Il;Choe, Bo-Young;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.442-445
    • /
    • 2002
  • We present an algorithm for automatic anatomically adaptive image enhancement of digital chest radiographs. Chest images were exposed using digital radiography system with a 0.143 mm pixel pitch, l4-bit gray levels, and 3121 ${\times}$ 3121 matrix size. A chest radiograph was automatically divided into two classes (lung field and mediastinum) by using a maximum likelihood method. Each pixel in an image was processed using fuzzy domain transformation and enhancement of both the dynamic range and local gray level variations. The lung fields were enhanced appropriately to visualize effectively vascular tissue, the bronchus, and lung tissue, etc as well as pneumothorax and other lung diseases at the same time with the desired mediastinum enhancement. A prototype implementation of the algorithm is undergoing trials in the clinical routine of radiology department of major Korean hospital.

  • PDF

X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가 (A comparative study for resolution and density of chest imaging using film/screen, CR and DR)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제4권1호
    • /
    • pp.25-30
    • /
    • 2010
  • 이 연구 목적은 흉부영상의 진단에 적절한 해상력과 음영에 대한 적절한 평가를 위해서다. 해상력을 비교하기 위해서, linear 해상력 팬텀을 사용하여 film/screen(선생님이 원하시는 conventional radiography : film/screen), CR, DR, 촬영했다. 해상력을 비교하기 위해 2명의 영상의학과 전문의와 3명의 방사선사가 블라인드 테스트를 통하여 평가했다. DR 은 3.95 필름/ 스크린은 3.58, CR은 3.48의 평가가 나왔다. 음영에 대해 분석은, CR, DR의 film/screen의 정상적인 흉부영상 50장을 선택했다. 이 흉부영상에서 7부위(폐야, 폐야 윤곽, 종격동 I, 종격동 II, 심장 음영 I, 심장음영 II, 횡격막)을 정하여 덴시토미터(농도계)을 사용하여 음영을 평가했다. 우리의 분석 방법은 낮은 영상(음영)을 0에서부터 가장 우수한 영상(음영) 2를 정한 일본의 흉부 x-ray 평가 방법을 적용했다. DR의 경우 종격동 1, 종격동2, 심장 1, 심장2, 횡격막에서 2점을 기록하여 우수했다. 이와 반대로 CR에서는 폐부위와 폐음영 부위에서 2점으로 우수했다. 결론적으로, 해상력과 음영에 비교하면 후처리 알고리즘과 작은 픽셀 사이즈에 의한 DR은 CR과 film/screen 보다 우수하다고 도출하였다.