• 제목/요약/키워드: Chargeability

검색결과 23건 처리시간 0.025초

Evaluation of three-dimensional cole-cole parameters from spectral IP data

  • Yang Jeong-Seok;Kim Hee Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.383-389
    • /
    • 2003
  • Clay minerals show a distinct induced-polarization phenomenon, which is one of the most important factors for predicting groundwater flow and contaminant transport. This paper presents a step-by-step process to estimate Cole-Cole parameters from spectral induced-polarization (IP) data measured on the surface of three-dimensional earth. First, the inversion of low-frequency resistivity survey data is made to identify the dc resistivity ${\rho}_dc$ of a volume having IP effects. The other parameters, chargeability m, time constant $\tau$, and frequency dependence c, are sought for the polarizable volume. Next, using multi-frequency data, c can be obtained as high or low asymptotes of the slope of log phase vs. log frequency. Further, for low m, intrinsic $\tau$ is approximated by apparent one, ${\tau}_a$, which is derived from the relation ${{\omega}{\tau}}_a$=1 at an angular frequency $\omega$, where the imaginary component of spectral IP data has an extreme value. Finally, to obtain intrinsic m a two-step linearized procedure has been derived. For a body of given $\tau$ and c, forward modeling with a progression of m values yields a plot of observed vs. intrinsic imaginary components for a frequency. Since this plot is essentially linear, to extract the intrinsic imaginary component is quite simple with an observed value. Using the plot of intrinsic imaginary component vs. m, intrinsic m is determined. We present a synthetic example to illustrate that the Cole-Cole parameters can be recovered from spectral IP data.

  • PDF

폐광산의 토양오염영역 및 폐기된 광미의 탐지 (Geophysical Applications on the Soil-contamination Mapping and Detection of Buried Mine Tailings in the Abandoned Mine Area)

  • 이상규;황세호;이태섭
    • 자원환경지질
    • /
    • 제30권4호
    • /
    • pp.371-377
    • /
    • 1997
  • This paper presents the geophysical applications to the environmenml problem in an abandoned mine area. We would like to focus our attention on the mapping of the soil contamination and the detection of the buried mine tailings. For mapping the soil contamination. measurements of both in-situ magnetic susceptibility (k) and terrain conductivity were carried out. In-situ magnetic susceptibilities of the contaminated soil due to the acid mine drainage show higher values than those of the uncontaminated area. However. those data do not show the correlation with the degree of the soil contamination observed on the surface. The least-squares fitted formula obtained with the measured insitu magnetic susceptibilities is $k=4.8207{\times}W^{0.6332}$, where W is the $Fe^{+2}$ weight percentage. This weight gives most effect to magnetic susceptibility of the soil. Lateral variations of the soil contamination in the shallow subsurface can be detected by the electrical conductivity distributions from EM induction survey. TDIP (Time Domain Induced Polarization) and EM induction surveys were conducted to detect the buried mine tailings. From the results of TDIP, the spatial zone, which shows high chargeability-low resistivity, is interpreted as the buried mine tailings. Therefore, it is concluded that it is possible to discriminate the spatial zone from the uncontaminated ground.

  • PDF

3차원 IP 탐사의 모형 응답 계산 (Three Dimensional Induced Polarization Modeling)

  • 남명진;서정희
    • 지구물리와물리탐사
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2001
  • 지하 환경 오염 현황 조사 및 대규모 토목 구조물 현장의 지반 조사 시 대상 지역의 정밀 영상화 자료가 요구된다. 이를 위해서 다양한 물리 탐사 기법이 통합되어 적용될 필요가 있다. 본 연구에서는 현재 국내에서 가장 활발하게 활용되고 있는 물리탐사 방법인 전기비저항 탐사와 동시 탐사가 가능하다는 장점이 있는 유도 분극 탐사 자료에 대한 고찰한다. 이 논문에서는, 기존의 3차원 전기비저항 모형 반응 계산 알고리듬을 바탕으로 3차원 충전성 모형 반응 계산을 하고자한다. 본 연구에서의 3차원 모형 응답 반응 계산의 결과를 2차원 모형 반응 계산 결과와 비교하여 모형 반응 계산알고리듬의 타당함을 확인하였다. 본 연구는 앞으로 이루어질 유도 분극 탐사자료에 대한 연구의 기반이 되리라 기대된다.

  • PDF

고출력.고에너지 밀도의 아연금속-공기전지 (Rechargeable Zn-air Energy Storage Cells Providing High Power Density)

  • 박동원;김진원;이재광;이재영
    • 공업화학
    • /
    • 제23권4호
    • /
    • pp.359-366
    • /
    • 2012
  • 아연금속-공기전지는 기존의 이차전지보다 높은 중량당 에너지 밀도, 낮은 제조단가를 가짐과 동시에 소재적으로 친환경적이다. 소형 및 중대형 전력 저장 시스템, 전기자동차, 스마트 휴대기기의 상용화에 있어 최우선시 되고 있는 것은 배터리의 충 방전 능이다. 따라서 환원 촉매의 높은 과전압, 산화 전극의 불안정성 및 비가역성, 액체 전해질 사용에 따른 여러 문제점을 해결하여야 한다. 본 총설에서는 공기극 막의 손상 방지 기술, 아연금속 전극의 구조 개선을 통한 충전효율 저하 방지 기술, 부반응 및 부동태화를 막기 위한 하이브리드 전해질 도입 등의 최근 기술적 이슈와 연구동향을 소개하고자 한다.

Contribution of Geophysics to the Study of Barite Mineralization in the Paleozoic Formations of Asdaf Tinejdad (Eastern Anti Atlas Morocco)

  • Ibrahim, Dakir;Ahmed, Benamara;Habiba, Aassoumi;Abdessalam, Ouallali;Youssef, Ait Bahammou
    • 자원환경지질
    • /
    • 제53권3호
    • /
    • pp.259-269
    • /
    • 2020
  • The use of the geophysical method in mining prospecting has been studied in the Asdaf region (South-East of Morocco). The objective of the study is to examine the aptitude of the electrical technique, in this case induced polarization (IP) and electric tomography, combined with the electromagnetic method (VLF), in the exploration of barite . The result obtained by the pseudo-sections of electrical tomography and that of KH filtration highlighted anomalies of resistant contact (greater than 400Ω.m) and of high charge chargeability (5mV / V). These contacts are hosted in less resistant Devonian age shale and sandstone. The resistivity response obtained at their level is characteristic of the venous structures associated with barite mineralization. The direction of the mineralized veins is parallel to the direction of the fractured zones (NE-SW), which indicates that the mineralization in place is due to the tectonic movements of the Hercynian orogeny (from Devonian to Permian). These veins are aligned with the locations of abandoned mine shafts and with surface mining areas. Geophysical technique therefore seems to play a key role in barite mining exploration.

시간영역 유도분극 자료로부터 Cole-Cole 변수 산출 (Extraction of Cole-Cole Parameters from Time-domain Induced Polarization Data)

  • 김연정;조인기
    • 지구물리와물리탐사
    • /
    • 제24권4호
    • /
    • pp.164-170
    • /
    • 2021
  • 주파수 및 시간영역 유도분극 탐사는 지하 매질의 분광 정보를 포함하고 있다. 분광 특성의 분석은 주로 주파수영역 유도분극 탐사에서 연구되어 왔으나, 근래에 시간영역 유도분극에서도 연구가 활발하게 이루어지고 있다. 이 연구에서는 반무한 균질 공간을 가정하고 측정된 2차 전위 및 전기비저항으로부터 Cole-Cole 변수를 추정하는 역산법을 개발하였다. 충전성, 완화시간 및 주파수 승수로 구성되는 Cole-Cole 변수들은 비독립적이기 때문에 통상적인 비선형 역산을 적용할 경우 느린 수렴속도, 적정 초기 모델 설정의 어려움, 지역 극소점, 발산 위험 등의 다양한 문제점이 발생한다. 이 연구에서는 격자 탐색법을 도입하여 참 모델에 근접한 초기 모델을 설정하는 효과적인 역산법을 개발하였다. 마지막으로 다양한 역산 실험을 통하여 개발된 역산법의 타당성을 검증하였다.

가곡 스카른광상 암석의 물리적 특성 (Physical Properties of Rocks at the Gagok Skarn Deposit)

  • 신승욱;박삼규;김형래
    • 지구물리와물리탐사
    • /
    • 제16권3호
    • /
    • pp.180-189
    • /
    • 2013
  • 물리탐사는 금속광상에서 광화대를 탐사하는데 효율적인 방법으로 국내 외에서 전략광물자원을 개발하기 위하여 널리 이용되고 있다. 물리탐사 결과로부터 광화대를 정확하게 해석하기 위하여 암석의 물리적 특성을 이해하는 것이 매우 중요하다. 따라서 이 연구는 국내 대표적 스카른 광상인 가곡광산의 광석 및 모암을 대상으로 실내에서 다양한 물성을 측정하였으며, 그 결과로부터 가곡 스카른 광상을 구성하는 지층의 물리적 특성을 파악하고자 하였다. 암석시료는 시추코어 및 노두에서 채취하였으며, 시료의 물성은 실내 암석물성 측정시스템을 이용하여 밀도, 대자율, 전기비저항, 광대역 유도분극을 측정하였다. 그 결과 광석은 모암에 비하여 낮은 전기비저항과 높은 대자율 및 밀도를 보였으며, 광대역 유도분극에서 큰 위상과 특정한 임계주파수가 나타났다. 광석의 광대역 유도분극 측정 자료를 Cole-Cole 역산을 통하여 얻은 충전성과 시간상수로부터 황화광물의 함량과 입자의 크기를 추정할 수 있어 스카른 광상 탐사에서 유용할 것으로 기대된다.

전기비저항과 유도분극을 활용한 TBM 터널 굴착면 전방 복합지반 예측 기법 (Forward probing utilizing electrical resistivity and induced polarization for predicting mixed-ground ahead of TBM tunnel face)

  • 류진우;박진호;이성원;이인모;김병규
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.55-72
    • /
    • 2018
  • 본 연구에서는 시공 중 TBM 터널에서 전기비저항과 유도분극(induced polarization, IP) 탐사를 활용하여 굴착면 전방의 복합지반(mixed-ground)을 예측하기 위한 방안을 제시하였다. TBM이 토사를 굴진하며, 굴착면 전방에서 상부 토사지반과 하부 암반으로 이루어진 복합지반을 조우하는 과정과 동시에 전기비저항과 유도분극에 의한 충전성(chargeability)을 측정하며 굴진하는 과정을 실내실험으로 모사하였다. 전기비저항과 충전성의 측정은 4전극을 이용하였으며, 복합지반을 효과적으로 예측하기 위하여 2개의 전극은 굴착면에, 나머지 2개의 전극은 조립된 세그먼트에 설치됨을 가정하였다. 실험 결과, TBM이 토사 굴진 중 토사-암반의 복합지반으로 진입할 경우 전기비저항과 충전성이 모두 증가하였다. 또한, TBM이 굴착면 전방에서 복합지반을 조우할 것임을 예측하기 위하여 굴착면의 전극 2개, 세그먼트의 전극 2개를 활용한 탐사와 동시에 굴착면 4전극 탐사를 수행하면 더욱 효과적인 예측이 가능함을 확인하였다.

최대 밀도 이론을 이용한 고성능콘크리트의 배합 설계 (Mix Design of High Performance Concrete Using Maximum Density Theory)

  • 이승한;정용욱
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.377-383
    • /
    • 2007
  • 최근 콘크리트의 품질과 구조물의 신뢰성을 향상시키기 위해서 고성능콘크리트의 현장 적용이 늘고 있다. 이러한 고성능콘크리트의 배합 설계 방법으로는 모르타르-굵은골재 2상계 배합 이론과 페이스트-골재 2상계 배합 이론이 있다. 이 중 모르타르-굵은골재 2상계 배합이론은 모르타르의 레올로지 특성을 부여함에 있어 반복적인 실험을 통해서 그 값을 결정해야 하는 문제점을 가지고 있다. 페이스트-골재 2상계 배합 이론은 최적 잔골재율과 단위결합재량과의 관계 및 콘크리트의 충전성을 확보할 수 있는 한계 골재 용적비 등이 고려되어 있지 않아 고성능콘크리트에의 적용 예가 없는 실정이다. 또한 이들 고성능콘크리트의 배합 설계 이론은 일반콘크리트와는 달리 유동성 및 충전성에 중점을 두고 있어 배합 설계에서 강도 특성을 고려하지 않고 있으며, 사용 재료의 단위량은 일반콘크리트와 같이 시행착오법으로 결정하고 있다. 이에 본 연구에서는 고성능콘크리트의 배합 설계에 최대 밀도 이론을 도입하여 사용 골재의 공극이 최소가 되는 최적 잔골재율 산정으로 배합 설계 시 시행착오를 줄이고, 강도를 고려한 최소 단위 결합재량의 결정으로 강도와 유동성을 동시에 만족할 수 있는 합리적이며 간편한 고성능콘크리트의 배합 설계법을 제안하고자 하였다. 연구 결과 본 연구에서 제안된 배합 설계법은 최소 공극을 갖는 최적 잔골재율 사용과 최소 단위 결합재량 이상의 결합재를 사용함으로써 시행착오를 줄일 수 있어 자기충전성을 갖는 고성능콘크리트를 간편하게 제조할 수 있다.

유도분극 탐사의 원리 및 활용 (The Principles and Practice of Induced Polarization Method)

  • 김빛나래;남명진;장한누리;장한길로;손정술;김희준
    • 지구물리와물리탐사
    • /
    • 제20권2호
    • /
    • pp.100-113
    • /
    • 2017
  • 유도분극(induced polarization; IP) 탐사는 분극 현상으로 인해 매질에서 발생하는 과전압을 측정하는 전기전자 탐사법으로 주로 금속 광상을 찾을 때 사용되었으나 장비의 발전에 힘입어 최근에는 지하수, 환경 오염, 지반 등 여러 분야에서 다양하게 활용되고 있다. IP 탐사에는 충전율을 측정하는 시간영역 IP 탐사, 진동수 효과를 측정하는 진동수영역 IP 탐사, 그리고 복소수 전기비저항을 측정하는 복소 전기비저항 탐사와 광대역 IP (spectral IP; SIP) 탐사 등이 있다. 또한, 최근에는 전극 형태의 측정 방법의 단점을 보완하기 위해 전자기 유도에 기초한 IP 법도 개발되어 지속적으로 연구가 진행되고 있다. 다양한 IP 탐사법에 대한 체계적인 이해를 돕기 위해 이 논문에서는 1) 송신원 형태와 측정 자료를 기준으로 IP 탐사법을 분류하고 이들에 대한 개념 정리와 함께 2) 각 탐사법의 수치 모델링 및 역산 알고리듬 발전 과정을 자세히 기술하고 3) 마지막으로 IP 탐사의 다양한 현장 활용 사례를 소개하고자 한다.