• Title/Summary/Keyword: Charge-pump

Search Result 296, Processing Time 0.022 seconds

Dual Sampling-Based CMOS Active Pixel Sensor with a Novel Correlated Double Sampling Circuit

  • Jo, Sung-Hyun;Bae, Myung-Han;Jung, Joon-Taek;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • In this paper, we propose a 4-transistor active pixel sensor(APS) with a novel correlated double sampling(CDS) circuit for the purpose of extending dynamic range. Dual sampling techniques can overcome low-sensitivity and temporal disparity problems at low illumination. To accomplish this, two images are obtained at the same time using different sensitivities. The novel CDS circuit proposed in this paper contains MOS switches that make it possible for the capacitance of a conventional CDS circuit to function as a charge pump, so that the proposed APS exhibits an extended dynamic range as well as reduced noise. The designed circuit was fabricated by using $0.35{\mu}m$ 2-poly 4-metal standard CMOS technology and its characteristics have been evaluated.

A Study on the Improvement of Characteristics of Precharge PFD (Precharge형 PFD의 동작 특성 개선에 관한 연구)

  • Woo, Young-Shin;Kim, Du-Gon;Oh, Reum;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3088-3090
    • /
    • 2000
  • In this paper, we introduce a charge pump PLL architecture which employs precharge phase frequency detector(PFD) and sequential PFD to achieve high frequency operation and fast acquisition. Operation frequency is increased by using precharge PFD when the phase difference is within -${\pi}\;{\sim}\;{\pi}$ and acquisition time is shortened by using sequential PFD and increased charge pump current when the phase difference is larger than |${\pi}$|. SO error detection range of proposed PLL structure is not limited to -${\pi}\;{\sim}\;{\pi}$. By virtue of this multi-phase frequency detector structure, the maximum operating frequency of 423MHz at 2.5V and faster acquisition were achieved by simulation.

  • PDF

Fault Classification in Phase-Locked Loops Using Back Propagation Neural Networks

  • Ramesh, Jayabalan;Vanathi, Ponnusamy Thangapandian;Gunavathi, Kandasamy
    • ETRI Journal
    • /
    • v.30 no.4
    • /
    • pp.546-554
    • /
    • 2008
  • Phase-locked loops (PLLs) are among the most important mixed-signal building blocks of modern communication and control circuits, where they are used for frequency and phase synchronization, modulation, and demodulation as well as frequency synthesis. The growing popularity of PLLs has increased the need to test these devices during prototyping and production. The problem of distinguishing and classifying the responses of analog integrated circuits containing catastrophic faults has aroused recent interest. This is because most analog and mixed signal circuits are tested by their functionality, which is both time consuming and expensive. The problem is made more difficult when parametric variations are taken into account. Hence, statistical methods and techniques can be employed to automate fault classification. As a possible solution, we use the back propagation neural network (BPNN) to classify the faults in the designed charge-pump PLL. In order to classify the faults, the BPNN was trained with various training algorithms and their performance for the test structure was analyzed. The proposed method of fault classification gave fault coverage of 99.58%.

  • PDF

Design of CMOS Fractional-N Frequency Synthesizer for Bluetooth system (Bluetooth용 CMOS Fractional-N 주파수 합성기의 설계)

  • Lee, Sang-Jin;Lee, Ju-Sang;Yu, Sang-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.890-893
    • /
    • 2003
  • In this paper, we have designed the fractional-N frequency synthesizer for bluetooth system using 0.35-um CMOS technology and 3.3-V single power supply. The designed synthesizer consist of phase-frequency detector (PFD), charge pump, loop filter, voltage controlled oscillator (VCO), frequency divider, and sigma-delta modulator. A dead zone free PFD is used and a modified charge pump having active cascode transistors is used. A Multi-modulus prescaler having CML D flip-flop is used and VCO having a tuning range from 746 MHz to 2.632 GHz at 3.3 V power supply is used. Total power dissipation is 32 mW and phase noise is -118 dBc/Hz at 1 MHz offset.

  • PDF

The Characteristics of High Voltage Output Flux Pump for Superconducting Magnet (초전도 마그네트용 고출력 플럭스 펌프의 특성)

  • Choi, Kyeong-Dal;Hahn, Song-Yop;Tsukiji, Hiroshi;Hoshino, Tsutomu;Muta, Itsuya
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.86-88
    • /
    • 1996
  • Using superconducting magnetic flux pump, thick power leads for a superconducting magnet could be replaced with thin string leads for the excitation magnet to the superconducting flux pump. We have developed a new type flux pump with high voltage output to shorten the charge and discharge time of the load magnet. The test of four stacked disks as the excither for the load magnet has been carried out. This disk type flux pump yielded 70 mV of voltage across its terminal and 10 A of current through 85 mH load magnet which was the field winding of 20 kVA class fully superconducting generator within 12 seconds. This output voltage of the new superconducting flux pump is about 10 times larger than that of the previous work Moreover since it is easy to stack the disks for the superconduction flux pump, the high voltage exciter for the 1H class superconducting magnet would be expected to be made easily.

  • PDF

Numerical analysis of the electromagnetic force for design optimization of a rectangular direct current electromagnetic pump

  • Lee, Geun Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.869-876
    • /
    • 2018
  • The force of a direct current (DC) electromagnetic pump used to transport liquid lithium was analyzed to optimize its geometrical and electrical parameters by numerical simulation. In a heavy-ion accelerator, which is being developed in Korea, a liquid lithium film is utilized for its high charge-stripping efficiency for heavy ions of uranium. A DC electromagnetic pump with a flow rate of $6cm^3/s$ and a developed pressure of 1.5 MPa at a temperature of $200^{\circ}C$ was required to circulate the liquid lithium to form liquid lithium films. The current and magnetic flux densities in the flow gap, where a $Sm_2Co_{17}$ permanent magnet was used to generate a magnetic field, were analyzed for the electromagnetic force distribution generated in the pump. The pressure developed by the Lorentz force on the electromagnetic force was calculated by considering the electromotive force and hydraulic pressure drop in the narrow flow channel. The opposite force at the end part due to the magnetic flux density in the opposite direction depended on the pump geometrical parameters such as the pump duct length and width that defines the rectangular channels in the nonhomogeneous distributions of the current and magnetic fields.

Experimental Study on the Heating Performance of a Variable Speed CO2 Heat Pump with a Variation of Operating Conditions (가변속 이산화탄소 열펌프의 난방성능 특성에 관한 실험적 연구)

  • Cho, Hong-Hyun;Lee, Ho-Sung;Jang, Yong-Hee;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.8
    • /
    • pp.694-701
    • /
    • 2007
  • The applications of a transcritical $CO_2$ cycle into water heaters show advantages over conventional systems in the respect of power consumption and heating efficiency because the $CO_2$ cycle has a high compressor discharge temperature. Besides, the heating performance of the transcritical $CO_2$ cycle can be improved by optimizing operating conditions. In this study, the heating performance of a variable speed $CO_2$ heat pump was measured and analyzed by varying refrigerant charge amount, EEV opening, compressor frequency and outdoor temperature. As a result, the optimum normalized charge for heating was 0.226. The COPs at the compressor frequencies of 40, 50 and 60 Hz were 2.94, 2.75 and 2.25, respectively. The heating performance of the $CO_2$ cycle with charge amount was more sensitive than the cooling performance. Moreover, the heating performance was improved significantly by optimizing of compressor frequency and EEV opening.

Passive Power Factor Correction Circuits for Electronic Ballasts using Voltage-Fed and Current-Fed Resonant Inverters (전압원 및 전류원 구동 공진형 인버터로 구성된 형광등용 전자식 안정기의 역률개선에 적합한 수동 역률 개선 회로에 관한 연구)

  • Chae, Gyun;Ryu, Tae-Ha;Cho, Gyu-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.266-269
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both voltage-fed and current-fed electronic ballast. The proposed PFC circuits use valley-fill(VF) type DC-link stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant capacitors. In current-fed type, the charge pump capacitors are connected with the additional secondary-side of the power transformer. The measured PF and THD are higher than 0.99 and 15% for all proposed PFC circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF

Effects on Performance of an Internal Heat Exchanger According to Charge Amount and Operating Condition in $CO_2$ Cooling Mode (이산화탄소 냉방운전 시 냉매충전량 및 운전조건에 따라 내부열교환기가 성능에 미치는 영향)

  • Kwak, Myoung-Seok;Cho, Hong-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • This is an experimental study on the performance characteristics of effective heat pump in the cooling mode using a single-stage compression $CO_2$ cycle with an IHX(internal heat exchanger). The performance of a single-stage compression with IHX was investigated according to charge amount and operating condition. Moreover, the performance characteristic of cooling operating was analyzed with the length of IHX. As a result, the optimum refrigerant charge amount was 2.2 kg. The optimal system COP for compressor frequency of 30, 40, 50, and 60 Hz was 3.493, 3.228, 2.978, and 2.659, respectively. Since the system with IHX can maintain large cooling capacity regardless of operating condition, the system performance doesn't reduce considerably under unfavorable condition. When the compressor frequency was 40 Hz, the COP for a system with IHX length of 3 m and 5 m was 3.361 and 3.51, respectively. By using the IHX into a $CO_2$ cooling system, the performance and reliability improves simultaneously.

Passive Power Factor Correnction Circuits for Electronic Ballasts using Voltage-Fed and Current-Fed Reconant Inverters (전압원 및 전류원 구동 공진형 인버터로 구성된 형광등용 전자식 안정기의 역률개선에 적합한 수동 역률개선 회로에 관한 연구)

  • Chae, Gyun;Ryoo, Tae-Ha;Cho, Gyu-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.515-522
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both v voltage-fed and current-f,어 ek'Ctronic ballast. The proposed PFC circuits use valley-fil[(VF) type DClink s stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations d during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant c capaCltor In current-fed type, the charge pump capacitors are connc'Ctc'Cl with the additional second따y-side of t the power transformer. The measured PF is higher than 0.99 and THD is about 10% for all proposed PFC c circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for i implementing cost longrightarroweffective electronic ballast.

  • PDF