• 제목/요약/키워드: Charge-Transfer

검색결과 1,027건 처리시간 0.03초

응급환자이송업에 종사하는 응급의료종사자의 직무만족도와 이직의도 (The Job Satisfaction and Turnover Intention of Emergency Medical Technician in the Private Ambulance Service)

  • 김미숙;이경열
    • 한국응급구조학회지
    • /
    • 제16권1호
    • /
    • pp.65-80
    • /
    • 2012
  • Purpose: The objective of this study was to assess the job satisfaction and turnover intention of the emergency medical technicians (EMT) in the private ambulance service, to examine their job satisfaction and turnover intention, and to provide the solution for the management of the private ambulance service. Methods: The survey was conducted with 121 EMTs (73 paramedics, 36 basic EMTs and 12 nurses) in the private ambulance service in Korea from September 15 to October 14, 2011. In the reliability of the questionnaire, Cronbach's ${\alpha}$ was 0.790 for job satisfaction and 0.796 for turnover intention. Using SPSS 18.0, we obtained Cronbach's ${\alpha}$, frequencies, percentages, means, and standard deviations, and performed independent t-tests, ANOVA, and Pearson's correlation analysis. Results: 1) The mean score with regard to job satisfaction was 2.94 and that of their turnover intention was 4.23. In the area of job satisfaction, the mean score of the job demand area was 4.23; 3.97 for the job itself; 3.07 for the area of interaction; 2.98 for the area of autonomy: 2.67 for the organizational demand area; 2.67 for working conditions area; and 1.73 for the wage area. 2) Statistically significant difference was observed in job satisfaction according to age (F=3.819, p=.006), wages (t=-4.640, p=.000), terms of incumbency (F=3.868, p=.011), and in turnover intention it was according to sex (t=-1.995 p=.048), age (F=9.611, p=.000), education levels (F=6.974, p=.002), marital status (t=4.393, p=.000), wages (t=5.515, p=.000), license types (F=8.481, p=.001), and terms of incumbency ( F=14.115, p=.000). 3) The job satisfaction and the turnover intention had a negative correlation to each other (r=-.56, p<.000) in general, and in the sub-7 areas of job satisfaction, the correlation with turnover intention was high in order of the wage area (r=-.61, p=.000), working conditions area (r=-.52, p=.000), the area of autonomy (r=-.49, p=.000), the area of interaction (r=-.45, p=.000), the organizational demand area (r=-.40, p=.000), the job itself (r=-.24, p=.007) and the job demand area (r=-.24, p=.009). Conclusion: The government must take the charge of lowering the turnover intention among paramedics in the private ambulance service by providing the advantage in wages and fringe benefits. Ultimately, this would bring an improvement in the quality of medical emergency services to hospitals especially in the area of patient transfer and transportation.

CIS의 전달특성과 SGL 함수를 이용한 적응적인 영상의 Colorimetry 분석 기법 (An Adaptive Colorimetry Analysis Method of Image using a CIS Transfer Characteristic and SGL Functions)

  • 이성학;이종협;송규익
    • 한국멀티미디어학회논문지
    • /
    • 제13권5호
    • /
    • pp.641-650
    • /
    • 2010
  • 컬러 이미지 센서는 광전 변환을 일으키는 촬상 소자와 내부의 영상처리 과정을 거쳐서 컬러 이미지를 출력한다. 일반적으로 출력 영상은 원 피사체의 XYZ 3 자극치와 카메라 RGB 출력 신호 사이의 변환 관계인 카메라 전달 특성에 의해 결정된다. 본 논문에서는 컬러 이미지 센서의 내부 조정 항목인 노출-증폭-레벨(shutter-gain-level, SGL)의 특성함수와 자동 화이트 밸런스 상태를 이용한 카메라 전달 행렬을 이용하여 영상의 colorimetry(측색) 상태를 분석하는 기법을 제안한다. 제안 방법으로부터 실제 영상물의 색도와 휘도 등을 예측할 수 있다. 연구에 사용된 컬러 이미지 센서의 AE(auto exposure) 상태와 실제 휘도의 관계를 정량화하여 SGL 함수를 유도하여 영상의 휘도를 예측 한다. 그리고 영상의 색도는 최소 제곱 다항식 모델링 (polynomial modeling)을 이용하여 기준 환경에서 얻은 카메라 전달 행렬과 AWB(auto white balance) 상태를 통해 예측한다. 실험을 통해서 컬러 이미지 센서를 이용한 제안된 영상의 색도와 휘도 예측 기법의 성능이 우수함을 볼 수 있고, 예측된 결과는 실제 영상물 계측과 시청 환경 측정을 이용한 디스플레이 화질 설정 시스템, 보안 등의 다양한 분야에서 응용이 가능하다.

공기 중 톨루엔에 의한 고분자전해질연료전지의 성능감소 (Decrease of PEMFC Performance by Toluene in Air)

  • 이호;송진훈;김기중;김세훈;안병기;임태원;박권필
    • Korean Chemical Engineering Research
    • /
    • 제49권1호
    • /
    • pp.15-20
    • /
    • 2011
  • 고분자전해질 연료전지에 유입되는 공기가 톨루엔에 오염되었을 때 전지 성능에 미치는 영향을 여러 톨루엔 농도와 운전 조건에서 연구하였다. 그리고 청정한 공기에 의한 전지 성능 회복과 활성탄 흡착에 의한 공기 중 톨루엔의 제거에 대해서도 연구하였다. 본 연구에서 실험한 톨루엔의 농도 범위는 0.1~5.0 ppm이었고 전지 성능감소와 회복은 일정전류에서 전압변화 측정법과 전기화학적 임피던스 측정법(EIS)에 의해 측정하였다. KOH 첨착활성탄의 톨루엔 흡착용량은 등온흡착곡선으로 구했다. 톨루엔 농도가 증가할수록, 전류밀도가 증가할수록, 공기유량이 증가할수록 톨루엔 오염에 의한 성능감소가 심했다. 그러나 상대습도가 증가할수록 톨루엔 오염에 의한 성능감소는 작았다. 가습된 청정 공기 중의 산소와 수분에 의한 톨루엔의 산화에 의해 전지의 성능이 회복되었다. 톨루엔의 백금 표면 흡착에 의한 전하 전달 저항 증가가 전지 성능을 주로 감소시킴을 EIS가 보였다. 첨착활성탄의 톨루엔 흡착 용량은 KOH 첨착량이 증가할수록 감소하였다.

Octamethylenethiafulvalene과 염화오스뮴, 이리듐, 백금 및 금 화합물의 합성과 특성에 관한 연구 (Synthesis and Characterization of Octamethylenethiafulvalene Compounds with Osmium, Iridium, Platinium and Gold Chloride)

  • 정찬규;이홍우;김영진;최성낙;김영인
    • 대한화학회지
    • /
    • 제45권5호
    • /
    • pp.442-447
    • /
    • 2001
  • Octamethylenethiafulvalene(OMTTF)와 $HAuCl_4{\cdot}3H_2O$를 THF 용액 내에서 직접 반응시켜 $(OMTTF)AuCl_4$를 합성하였다. $(OMTTF)_2PtCl_4,\; (OMTTF)_2\;IrCl6{\cdot}2H_2O,\; (OMTTF)OsCl5{\cdot}THF$ 등은 각각 $H_2PtCl_6{\cdot}xH_2O,\;H_2IrCl_6{\cdot}xH_2O$$H_2OsCl_6$를 사용하여 유사한 방법으로 합성하였다. 합성된 화합물들은 자기적(EPR, 자화율 측정), 분광학적(IR, UV-Vis), 전기화학적(CV) 특성과 전기전도도를 측정하였다. 상온에서의 분말 전기전도도는 모두 ~$10^{-7}\; S{\cdot}cm^{-1}$ 이하의 낮은 전기전도도를 나타내었다. 합성 과정에서 OMTTF로부터 Au, Pt, Ir, Os 금속 화합물로 전하 이동이 이루어져 OMTTF는 완전히 이온화된 $OMTTF^+$ 양이온 라디칼로 존재하였다. $OMTTF^+$ 양이온 라디칼의 안정성은 산화·환원 전위 값에서 확인하였다. 자화율 결과로부터 $(OMTTF)_2IrCl_6{\cdot}2H_2O$$(OMTTF)OsCl5{\cdot}THF$에서는 $OMTTF^+$ 이온에 존재하는 홀전자와 중심 금속(Ir 및 Os)에 편재화된 홀전자들 사이에는 강한 반강자성 상호작용이 존재함을 알 수 있었다.

  • PDF

응급환자의 방사선영상검사 분포 및 Patient Care (The Distribution and Patient Care in Radiography for Emergency Outpatients)

  • 이환형;강원한
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.55-74
    • /
    • 1996
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distribution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 761 emergency outpatients who visit during JAN, 1994 at ER of the general hospital in Pusan city. The results is as follows: Emergency radiography rate of simple radiography was 61.1 %, special radiography 2.5 %, CT 12.6 %, and ultrasonography 6.7 %. In simple radiography rate, a high rate was distributed on male(63.6 %), thoracicsurgery part(90.0%), admission patient(74.9 %), and long stayed patient at ER. In special raiography rate, a high rate was observed in urologic part(28.6%), and in CT rate, observed neurosurgery part(49.2 %) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8 %) and internal medicine part(15.9 %). There are distributed regional radiography rate in radiographic type that chest(55.3 %) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0 %) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neurosurgery, chest(90.0%) in thoracic-surgery, abdomen(58.0%) in general-surgery, spine (40.0% ) in neuro-surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic-surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiographic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transfered patient(2.7) in patient type, and on neurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional part was highly distributed on chest(499 case number). Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, radiographer should know well about dealing with contrastmedia administration and related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography, Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always silted with CT room and monitoring-patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiography should be established in ER area, and the radiographer of this room should be stationed radiologic technician who is career and can implement emergency patient care.

  • PDF

CaMoO4:RE3+ (RE=Eu, Dy) 형광체의 제조와 광학 특성 (Synthesis and Optical Properties of CaMoO4:RE3+ (RE=Eu, Dy) Phosphors)

  • 조신호
    • 한국진공학회지
    • /
    • 제22권2호
    • /
    • pp.79-85
    • /
    • 2013
  • 희토류 이온 $Eu^{3+}$$Dy^{3+}$가 각각 도핑된 $CaMoO_4$ 광체 분말을 고상반응법으로 합성하였다. 모든 형광체 분말의 결정 구조는 활성제 이온의 종류와 농도비에 관계없이 주 회절 피크(112)를 갖는 정방 정계이었다. $Eu^{3+}$ 이온이 도핑된 형광체의 경우에, $Eu^{3+}$ 이온의 농도가 0.01~0.10 mol 영역에서 결정 입자의 크기는 전반적으로 증가하였고, 비교적 균일한 크기 분포를 가지면서 조약돌 형태를 나타내었으며, 흡광 스펙트럼은 311 nm를 정점으로 넓게 퍼져있는 전하 전달 밴드와 파장 영역 360~470nm에서 약한 피크를 갖는 다수의 흡수선이 관측되었으며, 주 발광 스펙트럼은 $Eu^{3+}$ 이온의 $^5D_0{\rightarrow}^7F_2$ 전이에 의한 618 nm에 피크를 갖는 강한 적색 발광이었다. $Dy^{3+}$ 이온이 도핑된 분말의 경우에, 흡광 스펙트럼은 303 nm에 피크를 갖는 전하 전달 밴드와 상대적으로 세기가 약한 다수의 $Dy^{3+}$ 이온의 전이 신호가 발생하였으며, 주 발광 스펙트럼은 $^4F_{9/2}{\rightarrow}^7H_{13/2}$ 전이에 의한 578 nm에 피크를 갖는 황색 발광 스펙트럼이 관측되었다.

이온 교환막에서 이온의 비 평형 정상상태 이동을 이용한 단일 전해액의 배출만을 가지는 pH 조절용 연속식 전해 반응기 개발 (Development of a Continuous Electrolytic System for pH-control with Only One Discharge of Electrolytic Solution by Using Non-equilibrium Steady State Transfer of Ions across Ion Exchange Membranes)

  • 김광욱;유제욱;김인태;박근일;이일희
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.101-109
    • /
    • 2005
  • 본 논문에서는 불필요한 용액의 발생이 없이 전해 반응계로 주입되는 용액을 오직 pH 만을 조절시켜 배출시키기 위한 연속식 이온 교환막 전해 시스템을 개발하였다. 여기서는 전해 반응기 앞에 한 pH-조정조를 두고 대상 용액을 pH-조정조로 주입하면서 pH-조정조의 용액의 일부를 이온 교환막에 따라 음극방 또는 양극방으로 거처 다시 pH-조정조로 순환하게 하고. 또한 pH-조정조의 용액의 일부는 상대극방을 통과시킴으로써 pH가 산성 또는 알카리로 조절되어 배출되게 하였다. 이러한 전해반응기에서 pH 조절 과정은 음극과 양극 사이에 전압 차가 형성될 시, 이온 교환막을 통한 용액에 존재하는 이온의 전기이동 현상에 의해 유발되는 음극방과 양극방에서 용액의 전하 비 평형 현상과 이에 따른 물의 전해 분해 과정에 의해 설명되었다.

  • PDF

활성제 이온의 농도 변화에 따른 La2MoO6:RE3+ (RE = Eu, Sm) 형광체의 발광 특성 (Luminescence Properties of La2MoO6:RE3+ (RE = Eu, Sm) Phosphors Subjected to the Different Concentrations of Activator Ions)

  • 김가연;신종언;조신호
    • 한국표면공학회지
    • /
    • 제50권4호
    • /
    • pp.282-288
    • /
    • 2017
  • $Eu^{3+}$- or $Sm^{3+}$-doped $La_2MoO_6$ phosphors were synthesized with different concentrations of activator ions via a solid-state reaction. The X-ray diffraction patterns exhibited that crystalline structures of all the phosphors were tetragonal systems with the dominant peak occurring at (103) plane, irrespective of the concentration and the type of activator ions. The crystallites showed the pebble-like crystalline shapes and the average crystallite size increased with a tendency to agglomerate as the concentration of $Eu^{3+}$ ions increased. The excitation spectra of $Eu^{3+}$-doped $La_2MoO_6$ phosphors contained an intense charge transfer band centered at 331 nm in the range of 250-370 nm and three weak peaks at 381, 394, and 415 nm, respectively, due to the $^7F_0{\rightarrow}^5L_7$, $^7F_0{\rightarrow}^5L_6$, and $^7F_0{\rightarrow}^5D_3$ transitions of $Eu^{3+}$ ions. The emission spectra under excitation at 331 nm exhibited a strong red band centered at 620 nm and two weak bands at 593 and 704 nm. As the concentration of $Eu^{3+}$ increased from 1 to 20 mol%, the intensities of all the emission bands gradually increased. For the $Sm^{3+}$-doped $La_2MoO_6$ phosphors, the emission spectra consisted of an intense emission band at 607 nm arising from the $^4G_{5/2}{\rightarrow}^6H_{7/2}$ transition and three relatively small bands at 565, 648, and 707 nm originating from the $^4G_{5/2}{\rightarrow}^6H_{5/2}$, $^4G_{5/2}{\rightarrow}^6H_{9/2}$, and $^4G_{5/2}{\rightarrow}^6H_{11/2}$ transitions of $Sm^{3+}$, respectively. The intensities of all the emission bands approached maxima when concentration of $Sm^{3+}$ ions was 5 mol%. These results indicate that the optimum concentrations for highly-luminescent red and orange emission are 20 mol% of $Eu^{3+}$ and 5 mol% of $Sm^{3+}$ ions, respectively.

창어 3호 개요 및 임무궤적 추정결과 분석 (Introduction to Chang'e-3 and Analysis of Estimated Mission Trajectory)

  • 최수진;이동헌;배종희;류동영;주광혁;심은섭
    • 한국항공우주학회지
    • /
    • 제43권11호
    • /
    • pp.984-997
    • /
    • 2015
  • 달 착륙선과 탐사 로버로 구성된 창어 3호는 2013년 12월 1일 시창 위성 발사 센터에서 장정 3B 발사체를 이용하여 발사되었다. 약 5일의 직접 전이궤적을 지나 달 궤도에 진입한 창어 3호는 달의 공전궤도에서 약 8일간 머무르다가 달 표면에 성공적으로 착륙하였다. 창어 3호의 성공적인 착륙은 한국의 달 탐사선 개발이 예정된 상황에서 향후 필요한 서브시스템의 기술 등을 분석하고, 발사에서 달 착륙까지의 궤적 및 운영 시퀀스 등을 도출하는데 많은 도움이 된다. 따라서 해외 언론에서 공지된 발사 현황을 바탕으로 창어 3호의 형상 및 전반적인 임무내용을 분석하고 시뮬레이션을 수행하였다. 그 결과 경계조건을 이용하여 제어변수를 추정 및 수렴값을 도출하여 착륙선의 전반적인 궤적을 생성하였다. 또한 이를 기반으로 교신 현황 및 식 현상을 분석하여 교신 및 전력충전이 양호함을 확인하였으며, 속도증분(${\Delta}V$)을 이용하여 비추력에 따른 착륙선의 여유 질량을 도출하였다.

전기방사법에 의해 제조된 폴리에틸렌옥사이드/폴리아닐린 섬유의 열적 및 전기적 거동 (Thermal and Electrical Behaviors of Polyethylene Oxide/Polyaniline Fibers Prepared by Electrospinning Method)

  • 김석;조미화;박수진
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.16-21
    • /
    • 2006
  • 본 연구에서는 폴리아닐린(PANI)을 제조하여 큰 분자량의 유기산인 10-camphor sulfonic acid (CSA) 또는 dodecylbenzene sulfonic acid (DBSA)로 도핑시키고, polyethylene oxide (PEO)와 함께 블렌딩하여 전기방사 용액을 제조하였다. 제조된 용액을 전기방사하여 섬유형태로 만든 후, TGA와 전기화학 장치(cyclic voltammetry; CV)로 열적, 전기적 성질을 CSA 또는 DBSA로 도핑된 PANI의 함량에 따라 비교, 분석하였다. 본 실험 결과, PANI-CSA와 PANI-DBSA의 함량이 증가함에 따라 열분해 개시온도는 감소하지만 열안정성 지수와 적분 열분해 진행온도가 증가하는 것으로 보아 열안정성은 증가하는 것으로 판단된다. 또한, 전기전도도는 PANI-CSA와 PANI-DBSA의 함량이 증가함에 따라 증가하였으나 30% 이상이 되면 전도도가 일정해지는 것으로 나타났다. 순환전류젼압 곡선 결과, PANI/CSA는 PANI-DBSA 보다 피크가 좀 더 명확해지며, 전류밀도가 크게 나타났다. 이는 PANI/CSA가 약간 더 높은 전기전도도와 전하가 이동하기 쉬운 모폴로지를 가지고 있기 때문인 것으로 판단된다.