• 제목/요약/키워드: Characteristic parameters

검색결과 2,071건 처리시간 0.035초

다결정 실리콘 박막 트랜지스터에서 공정 파라미터에 따른 전기적 특성의 모델링 (Modeling of Electrical Characteristics in Poly Silicon Thin Film Transistor with Process Parameter)

  • 정은식;최영식;이용재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.201-204
    • /
    • 2001
  • In this paper, for modeling of electrical characteristics in Poly Silicon Thin Film Transistors with process parameters set up optimum values, So, the I-V characteristics of poly silicon TFT parameters are examined and simulated in terms of the variations in process parameter. And these results compared and analyzed simulation values with examination value. The simulation program for characteristic analysis used SUPREM IV for processing, Matlab for modeling by mathematics, and SPICE for electric characteristic of devices. Input parameter for simulation characteristics is like condition of device process sequence, these electric characteristic of $I_D-V_D$ $I_D-V_G$, variations of grain size. The Gate oxide thickness of poly silicon are showed similar results between real device characteristics and simulation characteristics.

  • PDF

특성치 중요도를 고려한 다중특성치 파라미터 설계에 관한 연구 (A Study on the Parameter Design of Multiple Characteristics Considering Characteristical Importance)

  • 김용범;조용욱;김우열
    • 한국국방경영분석학회지
    • /
    • 제25권2호
    • /
    • pp.62-72
    • /
    • 1999
  • Taguchi´s parameter design is to determine the optimal settings of design parameters of a product or a process such that the characteristics of a product exhibit small variabilities around their targer values. His analysis of the problem has focused only on a single characteristic or response. However the quality of most products is seldom defined by a characteristic, and is rather the composite of a great number of characteristics which are often interrelated and nearly always measured in a variety of units. The critical problem in dealing with multiple characteristics is how to compromise the conflict among the selected levels of the design parameters for each individual characteristic. In this paper, Methodology using SN ratio optimized by unvariate technique is proposed and a parameter design procedure to achieve the optimal compromise among several different response variables is developed. One existing case study is solved by the proposed method and the results are compared with ones by the sum of SN ratios, the expected weighted loss, the desirability functions, and EXTOPSIS model.

  • PDF

단상 유도형 동기 전동기의 Cost 저감 설계 (Cost Reduction Design in Single-phase Line-start Permanent Magnet Motor)

  • 이병화;남혁;이정종;방량;홍정표;하승형
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2208-2212
    • /
    • 2008
  • This paper deals with the cost reduction design of a single-phase line-start permanent magnet(LSPM) motor. Due to high cost of the permanent magnet(PM), cost reduction can be effectively achieved by reducing PM volume. Therefore, motor characteristics according to the PM volume are calculated by using d-q axis equivalent circuit analysis, and the characteristic map is made. In the characteristic map, maximum torque and efficiency are shown according to motor parameters such as back electromotive force(back emf) and inductances; back emf represents the PM volume. Minimum back emf and inductances satisfying output performance are determined in the characteristic map. Then, motor geometry based on the prototype motor is optimized to get the determined parameters using response surface methodology(RSM) and finite element method(FEM). Through the presented cost reduction design, total PM volume is reduced to 32% of prototype model.

고 토크형 Hybrid PM 스텝모터의 최적설계를 위한 특성해석 (Characteristic Analysis of Hi9h Torque Hybrid PM Step Motor for the Optimum Design)

  • 이태화;공정식;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.870-872
    • /
    • 2000
  • This paper deals with the effect of rotor thickness variation and winding method in high torque hybrid Permanent Magnet(PM) step motor. As these parameters vary. The flux distribution in airgap and torque characteristics are influenced, which is related to output power. efficiency and cost. These parameters and characteristic variations were evaluated by using Finite Element Method (FEM) and experiment method. From these results. Characteristic analysis for the optimum design was studied and prototype motor was made to test performance analysis.

  • PDF

다결정 실리콘 박막 트랜지스터에서 공정 파라미터에 따른 전기적 특성의 모델링 (Modeling of Electrical Characteristics in Poly Silicon Thin Film Transistor with Process Parameter)

  • 정은식;최영식;이용재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.201-204
    • /
    • 2001
  • In this paper, for modeling of electrical characteristics in Poly Silicon Thin Film Transistors with process parameters set up optimum values. So, the I-V characteristics of poly silicon TFT parameters are examined and simulated in terms of the variations in process parameter. And these results compared and analyzed simulation values with examination value. The simulation program for characteristic analysis used SUPREM IV for processing, Matlab for modeling by mathematics, and SPICE for electric characteristic of devices. Input parameter for simulation characteristics is like condition of device process sequence, these electric characteristic of I$_{D}$-V$_{D}$, I$_{D}$-V$_{G}$, variations of grain size. The Gate oxide thickness of poly silicon are showed similar results between real device characteristics and simulation characteristics.ristics.

  • PDF

The Characteristic Calulation of Carboxylic Ion Exchanger.

  • 손원근;김태일;김상헌;박수길;정장훈
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권6호
    • /
    • pp.559-564
    • /
    • 2001
  • A method for calculating the main characteristics of a potentiometric titration curve in a carboxylic ion exchanger has been investigated. The potentiometric titration curves of simple electrolyte and ion exchangers (polyelectrolytes) showed a great difference between them. The acidity parameters of the ion exchangers, the thermodynamic constant (pK0), apparent equilibrium constant (K), and correction for the apparent equilibrium constant (b), were introduced and used to express the characteristics of the carboxylic ion exchanger. A characteristic equation related to the acidity parameters of the ion exchangers systems was derived. A fibrous carboxylic cation exchanger was used and potentiometric titration curves at different concentrations of the supporting electrolyte were obtained . To prove the validity of the characteristic equation, the concentration of the supporting electroyte was varied. In the present study, good agreement between the data points and the fitted curves was found in all the cases. The g (number of moles of alkali to 1 g of ion exchanger) of carboxylic ion exchanger was calculated from the concentration of supporting electrolyte (C), pH of the solution, and degree of neutralization of ion exchanger (x).

Examination of Efficiency Based on Air Gap and Characteristic Impedance Variations for Magnetic Resonance Coupling Wireless Energy Transfer

  • Agcal, Ali;Bekiroglu, Nur;Ozcira, Selin
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.57-61
    • /
    • 2015
  • In this paper wireless power transmission system based on magnetic resonance coupling circuit was carried out. With the research objectives based on the mutual coupling model, mathematical expressions of optimal coupling coefficients are examined. Equivalent circuit parameters are calculated by Maxwell software, and the equivalent circuit was solved by Matlab software. The power transfer efficiency of the system was derived by using the electrical parameters of the equivalent circuit. System efficiency was analyzed depending on the different air gap values for various characteristic impedances. Hence, magnetic resonance coupling involves creating a resonance and transferring the power without radiating electromagnetic waves. As the air gap between the coils increased the coupling between the coils were weakened. The impedance of circuit varied as the air gap changed, affecting the power transfer efficiency.

구조물의 소형화가 볼트 결합부의 동특성 파라미터에 미치는 영향 분석 (Effect of Scale-down of Structure on Dynamic Characteristic Parameters in Bolted-Joint Beams)

  • 김봉석;이성민;송준엽;이창우;이수훈
    • 한국정밀공학회지
    • /
    • 제24권3호
    • /
    • pp.108-116
    • /
    • 2007
  • To overcome many defects such as the high product cost, large energy consumption, and big space capacity in conventional mechanical machining, the miniaturization of machine tool and micro factory systems has been envisioned recently. The object of this paper is to research the effect of dynamic characteristic parameters in bolted-joint beams, which is widely applied to the joining of mechanical structures in order to identify structural system characteristics and to predict dynamic behavior according to scale-down from macro to micro system as the development of micro/meso-scale machine tool and micro factories. Modal parameters such as the natural frequency, damping ratio, and mode shape from modal testing and dynamic characteristics from finite element analysis are extracted with all 12 test beam models by materials, by size, and by joining condition, and then the results obtained by both methods are compared.

실리콘에 기초한 새로운 크로스바 구조의 손실있는 대칭 결합선로에 대한 유한차분법을 이용한 해석 (Analysis of Symmetric Coupled Line with New Crossbar Embedded on Si-based Lossy Structure using the FDTD Method)

  • Kim, Yoonsuk
    • 한국군사과학기술학회지
    • /
    • 제4권2호
    • /
    • pp.122-129
    • /
    • 2001
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite- Difference Time-Domain(FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency- dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

  • PDF

Is Transcranial Doppler Ultrasonography Old-fashioned?: One Institutional Validity Study

  • Han, Pan-Yeal;Kim, Jae-Hoon;Kang, Hee-In;Moon, Byung-Gwan;Lee, Seung-Jin;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권2호
    • /
    • pp.63-66
    • /
    • 2008
  • Objective : The purpose of this study is to investigate the correlation between various transcranial Doppler (TCD) ultrasonography parameters and clinical vasospasm after aneurysmal subarachnoid hemorrhage (SAH). Methods : This study enrolled 40 patients presented with aneurysmal SAH between September 2006 and August 2007. We measured differences of mean blood flow velocity (BFVm), highest systolic blood flow velocity (BFVh), and Lindegaard ratio (LR) in the middle cerebral artery on TCD examination. These parameters were evaluated for correlation with clinical vasospasm by univariate analysis and the receiver operating characteristic analysis. Results : Twelve patients (30%) developed clinical vasospasm. The best TCD parameters for the detection of clinical vasospasm were revealed to be differences of BFVm, BFVh, and LR values between $1^{st}$ TCD test and $3^{rd}$ TCD (7 cm/s. 11.5 cm/s, 0.45 respectively). The positive predictive value of anyone of three parameters was 60% and the negative predictive value was 100%. Conclusion : TCD is still considered a useful tool for screening clinical vasospasm. To confirm the predictive value of the above parameters. further prospective study will be needed.