• 제목/요약/키워드: Characteristic Determination

검색결과 335건 처리시간 0.032초

2항근사 볼츠만 방정식을 이용한 Ne의 전자수송재수 연구 (The study on the electron transport coefficients in Neon gas by 2-tenn approximation of the Boltzmann Equation)

  • 전병훈;하성철;송병두
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.236-238
    • /
    • 2003
  • The electron transport coefficients, the electron drift velocity W, the longitudinal diffusion coefficient $ND_L$ and $D_L/\mu$, in pure Ne were calculated over the wide E/N range from 0.01 to 800 Td at 1 Torr by two-term approximation of the Boltzmann equation for determination of electron collision cross sections set and for quantitative characteristic analysis of Ne molecular gas.

  • PDF

폐아세포종;1례 보고 (Pulmonary Blastoma - A Case Report)

  • 김영삼
    • Journal of Chest Surgery
    • /
    • 제25권9호
    • /
    • pp.900-904
    • /
    • 1992
  • Pulmonary blastoma is a very rare, primary, malignant neoplasm of the lung. The tumor typically is large, well-defined mass and arises in the periphery of the lung. Histologically, it resembles fetal lung tissue evoking the concept that these tumors are drived from the primitive pluripotential pulmonary blastema, but controversy also exit about the nature of this tumor. Clinical evaluation is inconsistant and unreliable as to the diagnostic determination of the tumor type and degree of malignancy. Therefore, diagnosis is usually based on histologic findings. The prognosis after adequate resection appears to be better than for other malignant tumors of the lungs. We experienced a case of pulmonary blastoma occurring in 56-year-old female. She was hospitalized for evaluation of an abnormal shadow in the left lower lung field which found incidentally on chest roentgenogram. We approached the lesion though left posterolateral thoracotomy and performed the left lower lobectomy. The microscopic findings of resected specimen revealed characteristic appearance of pulmonary blastoma. The postoperative course was uneventful without complication.

  • PDF

Analysis and prediction of ultimate strength of high-strength SFRC plates under in-plane and transverse loads

  • Perumal, Ramadoss;Palanivel, S.
    • Structural Engineering and Mechanics
    • /
    • 제52권6호
    • /
    • pp.1273-1287
    • /
    • 2014
  • Plates are most widely used in the hulls of floating concrete structures, bridge decks, walls of off-shore structures and liquid storage tanks. A method of analysis is presented for the determination of load-deflection response and ultimate strength of high-strength steel fiber reinforced concrete (HSSFRC) plates simply supported on all four edges and subjected to combined action of external compressive in-plane and transverse loads. The behavior of HSSFRC plate specimens subjected to combined uniaxial in-plane and transverse loads was investigated. The proposed analytical method is compared to the physical test results, and shows good agreement. To predict the constitutive behavior of HSSFRC in compression, a non-dimensional characteristic equation was proposed and found to give reasonable accuracy.

Solution State Structure of pA1, the Mimotopic Peptide of Apolipoprotein A-I, by NMR Spectroscopy

  • Kim, Hyo-Joon;Won, Ho-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권9호
    • /
    • pp.3425-3428
    • /
    • 2011
  • Apolipoprotein A-I (Apo A-I) is a major component for high density lipoproteins (HDL). A number of mimetic peptides of Apo A-I were screened from the phase-displayed random peptide library by utilizing monoclonal antibodies (A12). Mimetic peptide for A12 epitope against Apo A-I was selected as CPFARLPVEHHDVVGL (pA1). From the BLAST search, the mimetic peptide pA1 had 40% homology with Apo A-I. As a result of the structural determination of this mimotope using homo/hetero nuclear 2D-NMR techniques and NMR-based distance geometry (DG)/molecular dynamic (MD) computations, DG structure had low penalty value of 0.3-0.7 ${\AA}^2$ and the total RMSD was 0.6-1.6 ${\AA}$. The mimotope pA1 exhibited characteristic conformation including a ${\beta}$-turn from Pro[7] to His[11].

NMR Spectroscopy에 의한 Sulfonamide의 정량(定量) (Determination of Sulfonamides by NMR Spectroscopy)

  • 박만기;김성경;이숙연
    • 약학회지
    • /
    • 제28권5호
    • /
    • pp.287-291
    • /
    • 1984
  • A rapid and accurate NMR procedure for the analysis of a mixture of sulfametrol, sulfalene and sulfameter in $CDCl_3$ and $dimethylsulfoxide-d_6$ was developed. Thioacetamide was used as an internal standard. The signals chosen for the analysis were a singlet of 4.03ppm due to the methoxyl group of sulfametrol, a singlet of 3.98ppm due to the methoxyl group of sulfalene and a singlet of 3.83ppm due to the methoxyl group of sulfameter. The quantification of the characteristic peak was done by the integration method and the peak height method. The variation coefficient of sulfametrol, sulfalene and sulfameter were 1.7(n=6), 1.7(n=6) and 1.4%(n=6), respectively in the peak height method and 8.9(n=6), 9.4(n=6) and 7.0(n=6), respectively in the integration method.

  • PDF

자가용 발전기 모델 정수 결정 (Determination of Co-generator Model Parameters)

  • 김동준;김학만;전영환;김지원;전진홍;국경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.236-240
    • /
    • 2001
  • This paper presents the derivation of model parameters against a comparatively small industrial power plant, and validates its model parameters using the stored data measured at the time of on-site generator characteristic testing. Dynamic models such as generator, excitation system, and turbine/governor are mainly dealt in this paper. For the purpose of validation of derived model parameters, the measured results are compared with simulation results. Those of the comparisons between measured results and simulation results show good match.

  • PDF

TMCP 강의 부식열화 및 부식피로강도 평가 (Evaluation of Corrosion Fatigue Strength and Corrosion Degradation of TMCP Steel)

  • 박진형;배동호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.241-246
    • /
    • 2003
  • In order to develop a method of corrosion fatigue design and estimate reliability of TMCP steel using as the material of heavy industries and plants, its corrosion susceptibilities, corrosion fatigue strength, and determination of fatigue design criterion considering corrosion degradation were investigated. From the results, the corrosion characteristic of TMCP steel is very susceptible in 3.5wt.% NaCl solution. Its susceptibility was linearly increased with the solution temperature increase. The corrosion fatigue strength in $25${\circ}$, 3.5wt.% NaCl solution is very lower than that of in air. And also, it was decreased with the frequency decrease in the same environment. It is expected that the developed corrosion fatigue design method for TMCP steel is useful. However, it is necessary to verify its reliability for actual application.

  • PDF

다물체계 해석 방법을 이용한 동력 전달계의 특성 해석 (Analysis on Dynamic Characteristics of Power Transmission System Using Multibody Dynamics)

  • 우민수;공진형;한형석;임원식;박영일;이장무
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.476-480
    • /
    • 2003
  • This paper presents an effective method to analyze the dynamic characteristics for the shilling transients of power transmission system using the multibody dynamics, which is composed of subsystem equation, subsystem assemble, and the self-determining technique for the system degree of freedom. Using the advantages of multibody dynamics, the proposed method can be used easily for mathematical models of mechanical systems, such as a power transmission, compared with newtonian method. With this theory, dynamic simulation program was developed. The program can be used to verify system performances, transient phenomena, and other dynamic problems. The simulation of a target system was presented, and its validity was attained by being compared with the previous analysis using newtonian method.

  • PDF

공정혁신과 조직선별: 혁신경쟁의 모헝화와 시뮬레이션 분석 (Process Innovation and Selection of Organizational Structure : Modeling and Simulation of Innovation Competition Process)

  • 김창욱
    • 한국시스템다이내믹스연구
    • /
    • 제5권1호
    • /
    • pp.73-97
    • /
    • 2004
  • This paper explores the relationship between technological characteristics within process innovation and selection of the firms of different organizational forms in the evolution of an industry. For this purpose, this paper develops a simulation model for industrial change that replicates dynamic competition for process innovation. The simulation analysis found the following causal relationship. First, the stronger innovation impact in terms of productivity jump tends to enlarge the productivity difference among the incumbent firms and increase the speed of productivity catch-up by the large diversified firms, Second, the possibility of entry, and eventual dominance by the large diversified firms increase when the innovation-productivity linkage is stronger and there is less cumulativeness in productivity determination. These results imply that technological characteristics are important factors that have influence on whether or not the large diversified firms can enter and succeed in an industry.

  • PDF

반복제어기를 이용한 하드디스크의 주기적인 외란 보상 (Compensation of the Repeatable Run Out Using Repetitive Controller in HDD)

  • 신호철;박성원;박태욱;양현석;박영필
    • 한국소음진동공학회논문집
    • /
    • 제14권2호
    • /
    • pp.136-143
    • /
    • 2004
  • This paper presents three algorithms of repetitive controller for compensation of the repeatable runout in hard disk drive. The basic theory of the repetitive controller and the analysis of the disturbance in hard disk drive are introduced. The tracking controller is designed in order to design the "plug-in type" repetitive controller. Design of the repetitive controller is considered as the design of the filter, determination of gain and design of additional compensation for the various types. Specially, trade-off relationship between stability and performance is important for the design. The three kinds of "plug-in type" repetitive controllers are designed, simulated and experimented. Performance and characteristic of them are compared with the analysis of the experimental results.