• Title/Summary/Keyword: Channel Scan

Search Result 86, Processing Time 0.026 seconds

Generation of Sea Surface Temperature Products Considering Cloud Effects Using NOAA/AVHRR Data in the TeraScan System: Case Study for May Data (TeraScan시스템에서 NOAA/AVHRR 해수면온도 산출시 구름 영향에 따른 신뢰도 부여 기법: 5월 자료 적용)

  • Yang, Sung-Soo;Yang, Chan-Su;Park, Kwang-Soon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.165-173
    • /
    • 2010
  • A cloud detection method is introduced to improve the reliability of NOAA/AVHRR Sea Surface Temperature (SST) data processed during the daytime and nighttime in the TeraScan System. In daytime, the channels 2 and 4 are used to detect a cloud using the three tests, which are spatial uniformity tests of brightness temperature (infrared channel 4) and channel 2 albedo, and reflectivity threshold test for visible channel 2. Meanwhile, the nighttime cloud detection tests are performed by using the channels 3 and 4, because the channel 2 data are not available in nighttime. This process include the dual channel brightness temperature difference (ch3 - ch4) and infrared channel brightness temperature threshold tests. For a comparison of daytime and nighttime SST images, two data used here are obtained at 0:28 (UTC) and 21:00 (UTC) on May 13, 2009. 6 parameters was tested to understand the factors that affect a cloud masking in and around Korean Peninsula. In daytime, the thresholds for ch2_max cover a range 3 through 8, and ch4_delta and ch2_delta are fixed on 5 and 2, respectively. In nighttime, the threshold range of ch3_minus_ch4 is from -1 to 0, and ch4_delta and min_ch4_temp have the fixed thresholds with 3.5 and 0, respectively. It is acceptable that the resulted images represent a reliability of SST according to the change of cloud masking area by each level. In the future, the accuracy of SST will be verified, and an assimilation method for SST data should be tested for a reliability improvement considering an atmospheric characteristic of research area around Korean Peninsula.

Incremental Channel Scan Scheme based on Neighbor Channel Information in IEEE 802.11 Wireless LANs (IEEE 802.11 무선 랜에서 이웃 채널 정보에 기반한 점진적 채널 스캔 방법)

  • Huh, Nam Chul;Kim, Sunmyeng
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.5
    • /
    • pp.25-35
    • /
    • 2015
  • Handoff is a critical issue for seamless roaming in IEEE 802.11-based wireless networks. In order to provide real-time services, handoff mechanism must be provided. However, the IEEE 802.11 standard handoff is not appropriate to provide the services, because it is based on the full-scanning approach which spends too much time searching Access Point (AP). In this paper, we propose a new scheme, which can reduce the scanning latency. A station performs full-scanning operation for finding APs when it enters wireless networks for the first time. The station sends the scanned channel information to AP. AP maintains the neighbor channel table based on the information received from stations. A station performs the partial-scanning by using the table. Therefore, the proposed scheme can reduce the scanning latency.

An Efficient Secrete Key Protection Technique of Scan-designed AES Core (스캔 설계된 AES 코아의 효과적인 비밀 키 보호 기술)

  • Song, Jae-Hoon;Jung, Tae-Jin;Jeong, Hye-Ran;Kim, Hwa-Young;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.77-86
    • /
    • 2010
  • This paper presents an efficient secure scan design technique which is based on a fake key and IEEE 1149.1 instruction to protect secret key from scan-based side channel attack for an Advanced Encryption Standard (AES) core embedded on an System-on-a-Chip (SoC). Our proposed secure scan design technique can be applied to crypto IP core which is optimized for applications without the IP core modification. The IEEE 1149.1 standard is kept, and low area, low power consumption, very robust secret-key protection and high fault coverage can be achieved compared to the existing methods.

Fusion of 3D Cardiac SPECT and 64-Channel-CT Angiography Using Personal Computer in Functionally Relevant Coronary Artery Stenosis (개인용 컴퓨터를 이용한 기능 유관성 관상동맥 협착증의 삼차원 심장스펙트 사진과 64채널 전산화 단층 혈관촬영사진과의 융합)

  • Bahk, Yong-Whee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.252-254
    • /
    • 2007
  • Image fusion is fast catching attention as Wagner pointed out in his 2006 version of the recent progress and development presented at the annual meeting of Society of Nuclear Medicine. Prototypical fusion of bone scan and radiograph was already attempted at in 1961 when Fleming et al. published an article on strontium-85 bone scan. They simply superimposed dot scan on radiograph enabling simultaneous assessment of altered bone metabolism and local bone anatomy. Indeed the parallel reading of images of bone scan and radiography, CT, MRI or ultrasonography has been practiced in nuclear medicine long since. It is fortunate that recent development of computer science and technology along with the availability of refined CT and SPECT machines has permitted us to open a new avenue to digitally produce precise fusion image so that they can readily be read, exchanged and disseminated using internet. Ten years ago fusion was performed using Bresstrahlung SPECT/CT and it is now achievable by PET/CT and SPECT/CT software and SPECT/CT hardware. The merit of image fusion is its feasibility of reliable assessment of morphological and metabolic change. It is now applicable not only to stationary organs such as brain and skeleton but also to moving organs such as the heart, lung and stomach. Recently, we could create useful fusion image of cardiac SPECT and 64-channel CT angiograph. The former provided myocardial metabolic profile and the latter vascular narrowing in two patients with coronary artery stenosis and myocardial ischemia. Arterial stenosis was severe in Case 1 and mild in Case 2.

Limitations of 99mTc-DMSA scan in diagnosing acute pyelonephritis in children (이해관계 선언)

  • Kim, Byung Gee;Kwak, Jae Ryoung;Park, Ji Min;Pai, Ki Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.408-413
    • /
    • 2010
  • Purpose : We aimed to prove the relative limitation of $^{99m}Tc-DMSA$ scintigraphy (DMSA) compared to computed tomography (CT) in diagnosing acute pyelonephritis (APN) in children. Methods : Since September 2006, after a 64-channel CT was imported, 10 DMSA false-negative patients have been identified: these patients underwent a CT scan for acute abdomen or acute febrile symptoms and were diagnosed as having APN; however, their DMSA scans were clear. We focused on these 10 DMSA false-negative patients and analyzed their clinical findings and CT results. We used Philips Brilliance Power 64-channel CT scanner for the CT scan and Siemens Orbitor Nuclear Camera 60 Hz for the DMSA scan. Results : The 10 DMSA false-negative patients were mostly males (80%) and infants (80%). They had fever for a mean of 1.1-day duration before admission and showed increase in acute reactants: leukocyte, erythrocyte sedimentation rate, and C-reactive protein. The CT findings of renal lesions were focal in 6 (60%) cases and diffuse in 4 (40%) cases, and most of the lesions were unilateral in 80% of patients. CT proved that 22 renal lesions were neglected by DMSA. Differential renal function test by DMSA was also of no use in the evaluation of renal lesions. Conclusion : In this study, DMSA scan showed limitation in finding renal cortical lesions of CT-proven APN patients. DMSA false-negative results seem to occur at early-phase disease of infantile age, but more prospective studies are needed to determine the reasons and their prevalence.

A Multi-channel CMOS Feedforward Transimpedance Amplifier Array for LADAR Systems (라이다 시스템용 멀티채널 CMOS 피드포워드 트랜스임피던스 증폭기 어레이)

  • Kim, Seung-Hoon;Park, Sung Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1737-1741
    • /
    • 2015
  • A multi-channel CMOS transimpedance amplifier(TIA) array is realized in a $0.18-{\mu}m$ CMOS technology for the applications of panoramic scan LADAR systems. Each channel consists of a PIN photodiode and a feed-forward TIA that exploits an inverter input stage followed by a feed-forward common-source amplifier so as to achieve lower noise and higher gain than a conventional voltage-mode inverter TIA. Measured results demonstrate that each channel achieves $76-dB{\Omega}$ transimpedance gain, 720-MHz bandwidth, and -20.5-dBm sensitivity for $10^{-9}$ BER. Also, a single channel dissipates the power dissipation of 30 mW from a single 1.8-V supply, and shows less than -33-dB crosstalk between adjacent channels.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Cargo Inspection System Design and Boundary-Scan Test (화물 검색시스템 구현 및 Boundary_Scan Test)

  • Kim, Bong-Su;Kim, In-Su;Yoo, Sun-Won;Kim, Sung-Won;Lee, Sun-Wha;Yi, Yun;Han, Bum-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.197-200
    • /
    • 2002
  • We newly developed the procedures of X-ray Cargo inspection system with acquisition of multi-channel data, analog to digital converter and post logic circuit which is controlled by the FPGA. The IEEE1149.1 standard defines a four-wire serial interface(a fifth wire is optional)to access complex integrated circuits(ICs) such as PLD. This paper describes that Boundary_Scan test method applied to our home made cargo inspection system.

  • PDF

The design of an ASIC chip for synchronization between main and sub pictures in the multi channel TV system (멀티채널 TV 시스템에서 주화면과 부화면간의 동기화를 위한 ASIC 칩 설계)

  • 백승웅;선우명훈
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.2
    • /
    • pp.19-28
    • /
    • 1997
  • This paper presents the design of an SSIC chip for synchronization between main and sub pictures in the multi channel TV system (MUCTS). This chip can resolve problems in MUCTS, such as passing through and vertical jolt phenomena. In addition, this chip rpvivides compatibility for normal/doulble scan, interlace/progressive and normal (4:3)/wide (16:9) systems and has high hjorizontal and vertical resolutions (340) dots and 150 lines). In each mode there are 1 channel, 3 channel, and 4 position display functions. This MUCTS chip including three A/D coverters, a D/A converter and seven line memories was fabricated with one chip by using the $0.8\mu\textrm{m}$ CMOS technology. The application areas of this MUCTS ASIC chip include the wide TV, projection TV and te next generation TV for the DBS (direct broadcast system).

  • PDF

PCISS Scheme for Minimize Prove Delay in Wireless Mesh Networks (무선 메쉬 네트워크 환경에서 프로브 지연을 최소화한 PCISS 기법)

  • Cho, Young-Bok;Lee, Sang-Ho
    • Journal of Convergence Society for SMB
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Recently Wireless Communication technologies are widely used in Small And Medium Business fields. Wireless mesh networks have been studied as the next generation technology to solve problem of conventional wireless networks. Wireless mesh network uses a 802.11 when make up of network. mesh clients occurs Hard handover moving between ones. This increases the handover latency of the network mobility is a very great issues. Consequently, this paper propose a channel information previously methods to reduce the handover latency selective channels. Proposed scheme accounts for more than 90% of the probe delay to minimize the client had to move the mesh based on the old channel to retrieve information. Through simulation, the proposed scheme had shorter handover delay time than transitional full scan and selective scan. Through results of evaluation, the suggest PCISS scheme more fast 6.5% than transitional scheme.

  • PDF