• Title/Summary/Keyword: Channel Parameter

Search Result 665, Processing Time 0.028 seconds

Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates (고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성)

  • Lee, Jae-In;Woo, Sang-Hee;Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

Parameter Sensitivity Analysis of VfloTM Model In Jungnang basin (중랑천 유역에서의 VfloTM 모형의 매개변수 민감도 분석)

  • Kim, Byung Sik;Kim, Bo Kyung;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6B
    • /
    • pp.503-512
    • /
    • 2009
  • Watershed models, which are a tool for water cycle mechanism, are classified as the distributed model and the lumped model. Currently, the distributed models have been more widely used than lumped model for many researches and applications. The lumped model estimates the parameters in the conceptual and empirical sense, on the other hand, in the case of distributed model the first-guess value is estimated from the grid-based watershed characteristics and rainfall data. Therefore, the distributed model needs more detailed parameter adjustment in its calibration and also one should precisely understand the model parameters' characteristics and sensitivity. This study uses Jungnang basin as a study area and $Vflo^{TM}$ model, which is a physics-based distributed hydrologic model, is used to analyze its parameters' sensitivity. To begin with, 100 years frequency-design rainfall is derived from Huff's method for rainfall duration of 6 hours, then the discharge is simulated using the calibrated parameters of $Vflo^{TM}$ model. As a result, hydraulic conductivity and overland's roughness have an effect on runoff depth and peak discharge, respectively, while channel's roughness have influence on travel time and peak discharge.

The Flexible Design of 0.96 Tbps WDM System over 1,000km NZ-DSF by Using Optimal Parameters of Optical Phase Conjugator (광 위상 공액기의 최적 파라미터를 이용한 1,000km NZ-DSF를 갖는 0.96 Tbps WDM 시스템의 유연한 설계)

  • Lee, Seong-Real;Doh, Kyu-Bong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7A
    • /
    • pp.657-665
    • /
    • 2007
  • In this paper, it is investigated that the limitation due to the asymmetry of optical power and chromatic dispersion with respect to optical phase conjugator (OPC) for compensating optical signal distortion of WDM channels in mid-span spectral inversion (MSSI) technique is overcame by using OPC position offset and optimal dispersion coefficients of fiber sections, which depend on OPC position offset. It is confirmed that overall WDM channels are efficiently compensated by applying the optimal parameter values obtained from the proposed method into 24 channels ${\times}\;40\;Gbps$ WDM system with non zero - dispersion shifted fiber (NZ-DSF) of 1,000 km, such as power penalties of inter-channel are reduce to almost 3.5 dB from the infinite value. It is also confirmed that the flexible design of WDM system with OPC is possible by using the optimal parameters, in which OPC is placed at ${\pm}15\;km$ from 500 km for efficiently compensating overall channels.

Influence of Extinction Ratio on Optimal Parameters of OPC for Improving BER of WDM Signals (WDM 신호의 BER 개선을 위한 OPC의 최적 파라미터에 대한 소광비의 영향)

  • Lee, Seong-Real;Kweon, Soon-Nyu
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.4
    • /
    • pp.437-446
    • /
    • 2007
  • In this paper, we numerically induced the optimal values of optical phase conjugator (OPC) position and dispersion coefficients of fiber sections, which can improve the bit error rate (BER) and design the adaptive WDM transmission system, as a function of the extinction ratio (ER) of 10 dB and 20 dB in $16{\times}40$ Gb/s WDM transmission system. It is confirmed that these optimal parameter values for effectively compensating overall WDM channels are dependence on the extinction ratio of signals as well as modulation format, transmitted channel numbers, which were investigated in previous researches. It is also confirmed that ER of 20 dB has the advantage of designing flexible WDM systems using optimal parameters than ER of 10 dB.

  • PDF

Evaluation of Bubble Size Models for the Prediction of Bubbly Flow with CFD Code (CFD 코드의 기포류 유동 예측을 위한 기포크기모델 평가)

  • Bak, Jin-yeong;Yun, Byong-jo
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • Bubble size is a key parameter for an accurate prediction of bubble behaviours in the multi-dimensional two-phase flow. In the current STAR CCM+ CFD code, a mechanistic bubble size model $S{\gamma}$ is available for the prediction of bubble size in the flow channel. As another model, Yun model is developed based on DEBORA that is subcooled boiling data in high pressure. In this study, numerical simulation for the gas-liquid two-phase flow was conducted to validate and confirm the performance of $S{\gamma}$ model and Yun model, using the commercial CFD code STAR CCM+ ver. 10.02. For this, local bubble models was evaluated against the air-water data from DEDALE experiments (1995) and Hibiki et al. (2001) in the vertical pipe. All numerical results of $S{\gamma}$ model predicted reasonably the two-phase flow parameters and Yun model is needed to be improved for the prediction of air-water flow under low pressure condition.

Correlation of the Rates of Solvolyses of Cinnamyl Bromide

  • Koo, In-Sun;Cho, Jun-Mi;An, Sun-Kyoung;Yang, Ki-Yull;Lee, Jong-Pal;Lee, I.
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.4
    • /
    • pp.431-436
    • /
    • 2003
  • Solvolytic rate constants at 25℃ are reported for solvolyses of cinnamyl bromide (1) in binary mixtures of water with acetone, ethanol, methanol, methanol-d, and 2,2,2-trifluoroethanol. Product selectivities are reported for solvolyses of 1 in aqueous ethanol and methanol. Rate ratios in solvents of the same $Y_{Br}$ value and different nucleophilicity provide measures of the minimum extent of nucleophilic solvent assistance (e.g. $[k_{40EW}/k_{97TFE}]$Y = 2.88, EW = ethanol-water). With use of the extended Grunwald-Winstein equation, the l and m values are similar to the values of 0.43 and 0.88 obtained for the solvolyses of 1 using the equation (see below) which includes a parameter (I) for solvation of aromatic rings. The magnitude of l and m values associated with a change of solvent composition predicts the $S_{N1}$ reaction mechanism rather than an $S_{N2}$ channel. Product selectivities (S), defined by S = [ether product]/[alcohol product]×[water]/[alcohol solvent] are related to four rate constants for reactions involving one molecule of solvent as nucleophile and another molecule of solvent as general base catalyst. A linear relationship between 1/S and molar ratio of solvent is derived theoretically and validated experimentally for solvolyses of the above substrates from water up 75% 1/S = $(k_{wa}/k_{aw})$([alcohol solvent]/[water]) + $k_{ww}/k_{aw}$ alcohol-water. The results are best explained by product formation from a “free” carbocation intermediate rather than from a solvent-separated ion pair.

The Design of the Ternary Sequential Logic Circuit Using Ternary Logic Gates (3치 논리 게이트를 이용한 3치 순차 논리 회로 설계)

  • 윤병희;최영희;이철우;김흥수
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.10
    • /
    • pp.52-62
    • /
    • 2003
  • This paper discusses ternary logic gate, ternary D flip-flop, and ternary four-digit parallel input/output register. The ternary logic gates consist of n-channel pass transistors and neuron MOS(νMOS) threshold inverters on voltage mode. They are designed with a transmission function using threshold inverter that are in turn, designed using Down Literal Circuit(DLC) that has various threshold voltages. The νMOS pass transistor is very suitable gate to the multiple-valued logic(MVL) and has the input signal of the multi-level νMOS threshold inverter. The ternary D flip-flop uses the storage element of the ternary data. The ternary four-digit parallel input/output register consists of four ternary D flip-flops which can temporarily store four-digit ternary data. In this paper, these circuits use 3.3V low power supply voltage and 0.35m process parameter, and also represent HSPICE simulation result.

Fading channel modeling for non-geostationary orbit mobile satellite communication systems (비정지궤도 이동위성통신시스템에서의 페이딩 채널 모델링)

  • You, Moon-Hee;Park, Se-Kyoung;Lee, Soo-In
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.11
    • /
    • pp.12-18
    • /
    • 1998
  • In non-geostationary orbit(NGSO) satellite communication links, satellite's elevation angle at terminal is changed continuously because of the satellite movement relative to earth surface. Therefore the characteristics of the fade-effected signal received by a terminal from a NGSO satellite is also varied continuously even if the terminal is operated at fixed location. In this paper, we determine a general statistic model for the fading characteristics over NGSO satellite communication links and set up the parameters of the fading model in terms of the elevation angle according to various propagation environment and find the parameter values using the data of fading margin for commercial NGSO mobile satellite communication systems. And the fading charateristics for each environment are analyzed using this model. These results can be applied to develop the compensation algorithm and to analyze the performance of the transmission schemes for NGSO mobile satellite communication systems.

  • PDF

Preliminary Analysis of Data Quality and Cloud Statistics from Ka-Band Cloud Radar (Ka-밴드 구름레이더 자료품질 및 구름통계 기초연구)

  • Ye, Bo-Young;Lee, GyuWon;Kwon, Soohyun;Lee, Ho-Woo;Ha, Jong-Chul;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2015
  • The Ka-band cloud radar (KCR) has been operated by the National Institute of Meteorological Research (NIMR) of Korea Meteorological Administration (KMA) at Boseong National Center for Intensive Observation of severe weather since 2013. Evaluation of data quality is an essential process to further analyze cloud information. In this study, we estimate the measurement error and the sampling uncertainty to evaluate data quality. By using vertically pointing data, the statistical uncertainty is obtained by calculating the standard deviation of each radar parameter. The statistical uncertainties decrease as functions of sampling number. The statistical uncertainties of horizontal and vertical reflectivities are identical (0.28 dB). On the other hand, the statistical uncertainties of Doppler velocity (spectrum width) are 2.2 times (1.6 times) larger at the vertical channel. The reflectivity calibration of KCR is also performed using X-band vertically pointing radar (VertiX) and 2-dimensional video disdrometer (2DVD). Since the monitoring of calibration values is useful to evaluate radar condition, the variation of calibration is monitored for five rain events. The average of calibration bias is 10.77 dBZ and standard deviation is 3.69 dB. Finally, the statistical characteristics of cloud properties have been investigated during two months in autumn using calibrated reflectivity. The percentage of clouds is about 26% and 16% on September to October. However, further analyses are required to derive general characteristics of autumn cloud in Korea.

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.193-201
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.