• 제목/요약/키워드: Changwon area

검색결과 507건 처리시간 0.025초

GIS 기반의 물순환 면적률을 활용한 창원시 도심지역의 물순환성 평가 (An Assessment of Urban Water Cycle in Changwon-si Using GIS-based Water Cycle Area Ratio)

  • 송봉근;박경훈;이택순
    • 환경영향평가
    • /
    • 제22권5호
    • /
    • pp.397-408
    • /
    • 2013
  • The purpose of this study is to analyze water cycle area ratio and spatial evaluation of water cycle in urban area of Changwon-si, Gyeongsangnam-do. Water cycle area ratio are analyzed by using spatial data of land-cover and land-use, and Hot spot analysis of GIS program was used for spatial evaluation of water cycle. The results are as below. Firstly, the high water cycle area ratio areas were forests, parks, and rivers, but urban areas covered asphalt and concrete were low under 40%. Public institutions and co-residential of urban areas were higher than others because of high area ratio of pervious land-cover. Spatial evaluation of water cycle was analyzed to vulnerable areas there are dense residential and commercial area. These areas are really occurring frequently flooding and immersion, therefore, is required water management facilities and improvement of land-cover from impervious to pervious. In the future, it will require additionally analysis of water cycle area ratio supplemented data of water management facility and ground water.

UHF RFID 태그 칩용 저전력, 저면적 256b EEPROM IP 설계 (Design of a Low-Power and Low-Area EEPROM IP of 256 Bits for an UHF RFID Tag Chip)

  • 강민철;이재형;김태훈;장지혜;하판봉;김영희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.671-674
    • /
    • 2009
  • 본 논문에서는 수동형 UHF RFID 태그 칩에 사용되는 저전력, 저면적 256b 비동기식 EEPROM을 설계 하였다. 먼저 EEPROM의 저전력 특성을 얻기 위해 1.8V의 공급전압을 사용하였고, 저전압 특성을 갖는 N-type Schottky Diode를 사용하여 Dickson Charge pump를 설계하였다. 그리고 주변회로에서의 저면적 설계를 위해 비동기식 인터페이스 방식과 Separate I/O 방식을 사용하였다. 그리고 DC-DC 변환기의 면적을 줄이기 위하여 Schottky Diode를 사용한 Dickson Charge Pump를 설계하였다. $0.18{\mu}m$ EEPROM 공정을 이용하여 설계된 16 행 ${\times}$ 16 열의 어레이를 갖는 256b EEPROM의 레이아웃 면적은 $311.66{\times}490.59{\mu}m^2$이다.

  • PDF

근대개혁기 창원지역과 공문서 (Changwon Area and Official Documents during the Modern Reform Period)

  • 최규명
    • 기록학연구
    • /
    • 제78호
    • /
    • pp.285-336
    • /
    • 2023
  • 이 연구는 근대개혁기에 제정된 공문서 제도와 지방관청에서 생산한 공문서를 분석하여 당시 지방관청에서 이루어진 공문서 관리 실상을 들여다보고, 그 특징을 정리해 보고자 하였다. 이를 위하여 근대개혁기에 존재했던 지방관청 중에서 근대관청으로서 기능을 하고, 그 관청에서 생산된 공문서가 비교적 온전히 남아 있는 창원감리서를 대상으로 연구를 진행하였다. 먼저 창원감리서가 설치된 창원지역의 역사를 개괄하였다. 지난한 역사에서 창원의 마산포가 개항되고 감리서가 설치된 지리적 특성과 역사적 배경을 살펴보았다. 이어서 창원감리서의 기능을 법적 관점에서 분류하고 그 업무활동에서 생산된 공문서의 주요 내용과 역사적 맥락을 검토하였다. 마지막으로 당시 제정된 공문서 제도와 생산된 공문서의 형식을 비교 분석하여 근대개혁기 지방관청에서 생산한 공문서와 지방관청에 관한 공문서 제도의 특징을 정리하였다.

GIS 기반 노인인구 분포지역의 공간적 특성과 폭염의 관계 분석 - 창원시를 대상으로 - (Analysis of Relationship between the Spatial Characteristics of the Elderly Population Distribution and Heat Wave based on GIS - focused on Changwon City -)

  • 송봉근;박경훈;김경아;김성현;박건웅;문한솔
    • 한국지리정보학회지
    • /
    • 제23권3호
    • /
    • pp.68-84
    • /
    • 2020
  • 본 연구에서는 경상남도 창원시를 대상으로 노인인구 분포지역의 공간적 특성과 폭염과의 관계를 분석하였다. 이를 위해 통계청의 인구센서스 자료와 환경부 토지피복도, Landsat 8 지표면온도, 기상청의 폭염일수 자료를 활용하였다. 노인인구 분포의 공간적 특성은 토지이용특성을 고려하여 K-mean 군집화 분석을 통해 총 5개 유형으로 분류하였다. 공간유형별 노인인구 특성은 도시화된 유형(cluster-3)에서 노인인구의 수가 많았으나, 농촌지역과 산림지역에 분포하는 유형(cluster-1, cluster-2)에서는 노인인구의 구성 비율이 높은 것으로 나타났다. 지표면온도와 폭염일수 특성에서는 도시지역에서 지표면온도가 가장 높았으나 폭염일수는 농촌지역이 가장 많았다. 노인인구 분포지역의 공간유형에 따른 폭염 특성을 분석한 결과, 농촌지역 면적이 많은 cluster-2가 15.95일로 가장 높았고, 도시화된 유형인 cluster-3은 9.41일로 가장 낮았다. 즉, 도시지역에 거주하는 노인인구보다 농촌지역에 거주하는 노인인구가 폭염에 더욱 노출되어 있으며, 피해가 가중될 것으로 예상된다. 본 연구의 결과는 여름철 폭염 취약지역의 효과적인 관리와 사전 예방을 위한 다양한 정책방안을 마련하는데 기초적인 자료로 활용될 수 있을 것이다.

부산 대도시권의 통근권 변화에 관한 연구 (A Study on the Changes of Commuting Areas in the Busan Metropolitan Area)

  • 구동회
    • 대한지리학회지
    • /
    • 제48권4호
    • /
    • pp.533-544
    • /
    • 2013
  • 이 연구의 목적은 2000~2010년 사이에 부산 대도시권의 통근권이 어떻게 변화해왔는지를 분석하는 것이다. 이를 위해 연계성 지표를 사용하여 부산 대도시권을 설정한 후, 요인분석을 사용하여 부산 대도시권의 통근권 변화를 분석하였다. 부산 대도시권의 통근권은 동부산권, 서부산권, 김해 창원권, 울산권 등 4개로 구분되었다. 서부산 지역의 통근권은 축소되고 있으며, 지리적으로 인접한 강서구 북구 사상구와 김해 창원 지역의 통근연계구조는 강화되고 있다. 이는 서부산을 출발지로, 김해 창원을 도착지로 하는 역통근 통행이 증가한 결과이다. 울산 지역은 부산 대도시권 내에서 독립된 통근권을 형성하고 있다.

  • PDF

창원공단 주요 악취 민원 발생지역 주변 악취발생 현황조사 및 저감방안에 관한 연구 (Measurement of Complex Odor from Industries and Regulated Odorous Substance in Public Complaint Areas of Changwon Industrial Complex, and Its Reduction Countermeasure)

  • 오일환;서정윤;김태형
    • 한국환경과학회지
    • /
    • 제17권5호
    • /
    • pp.525-535
    • /
    • 2008
  • 5 public complaint areas against odor in Changwon Industrial Complex were selected and investigated to clear up the cause of the complaint. 16 companies operated in public complaint areas were visited and had a grip of their situation about odor generation and treatment. Two samples at it's site boundary of each company were taken to measure complex odor unit. Complex odor unit at the site boundary of investigated companies in the public complaint areas, for the most part, exceeded standard(odor unit 20) in industrial area. It was due to that this area was not designated as odor control region and that there are also many problems in current laws of Odor Protection Act, Air Quality Act and regional legislation. Accordingly, It will be necessary to revise the related legislation, to organize governance, to financially support the improvement of environmental facilities and to enforce guidance and the regulation rigidly for the odor emission reduction in Changwon Industrial Complex.

철로 주변의 지하굴착 영향권에 관한 연구 (A Study on the Influence Area of Excavation around Railroads)

  • 박종수;장정욱;박춘식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1032-1037
    • /
    • 2006
  • This thesis studied effects of the excavation around railroads on the deformation of the lateral ground and neighboring railroads. The conclusions of the study are as follows. 1. When the depth of excavationis 10m, the influential area should be 35m for soft clay, 20m for normal clay, 15m for hard clay, 15m for loose sand, 12m for slightly dense sand, and 8m for dense sand. 2. When the influential area is 10m, the allowable excavation depth should be 2.5m for soft clay, 4.8m for normal clay, 7.5m for hard clay, 7.2m for loose sand, 8.8m for slightly dense sand, and 10m for dense sand. 3. When the influential area is 20m, the allowable excavation depth should be 4.5m for soft clay, and up to 10m for the other five kinds of soil. 4. When the influential area is 30m, the allowable excavation depth should be 7.5m for soft clay, and up to 10m for the other five kinds of soil. 5. When the influential area is 35m, the allowable excavation depth should be up to 10m for all kinds of soil.

  • PDF

도시 열환경 개선을 위한 취약지역 선정 및 바람길 조성 방안: 창원시를 대상으로 (A Study on the Effectiveness of Wind Corridor Construction forImproving Urban Thermal Environment: A Case study of Changwon, South Korea)

  • 김종성;강정은
    • 환경영향평가
    • /
    • 제30권4호
    • /
    • pp.187-202
    • /
    • 2021
  • 본 연구는 경상남도 창원시의 열환경 개선을 위해 열환경, 찬공기의 생성·유동성 및 지리적 특성을 분석하여, 지역 맞춤형 바람길 조성 방안을 검토하였다. 공간분석(spatial analysis), 원격탐사(remote sensing) 기법을 활용하여 창원시의 지표면온도, 토지피복 및 토지이용, 바람장, 경사도를 측정하고 이를 통해 바람길 분석모형을 구성하였다. 2020년도를 기준으로 분석한 결과, 창원시는 전반적으로 찬공기 생성에 유리한 토지피복 특성을 가지고 있으나, 대부분의 도심지 지역의 기온이 가장 높게 나타났다. 북창원 생활권, 진북면, 웅동, 웅천동 등 지역의 기온이 비교적 높으며, 산지지역에서 평균 풍속이 높고, 시가지에서 평균 풍속이 낮은 전형적인 경향을 보였다. 이에 따라 북창원 생활권, 구 창원 도심지, 호계리·평성리 지역, 창포만 지역을 열환경 개선지역으로 도출하고 각 지역의 특성을 고려한 지역 내 찬공기 유입 및 주변 산지, 저수지, 공원 지역 등과의 바람 유동성 확보를 통해 기온저감 및 대기질을 개선할 수 있는 다양한 방안들을 제안하였다.

Avenue를 이용한 첨두홍수량 산정에 관한 연구 (A Study on the Peak Discharge using Avenue)

  • 박정우;최지혜;배덕효
    • 한국습지학회지
    • /
    • 제2권2호
    • /
    • pp.147-157
    • /
    • 2000
  • The objective of this study is to develop a NGIS-GUI (National Geographic Information System-Graphic User Interface) system for the computation of peak discharge at drainage basin outlet. The developed system is composed of GIS data extraction module, peak flow computation module and output display module. The selected study area is the Sungjun reservoir area near the Milyang, Kyungnam province and the peak flows depending on various recurrence intervals are computed and graphically displayed. The developed system will be useful for the scientific water flow management in the study area.

  • PDF