• Title/Summary/Keyword: Change a sample volume

Search Result 109, Processing Time 0.026 seconds

Influence of Sputtering Conditions on Structural and Electrochemical Properties of the Si Anode Film for Lithium Secondary Batteries (리튬 이차전지에서 Si 음극박막의 스퍼터링 증착조건에 따르는 구조적, 전기화학적 특성 연구)

  • Joo, Seung-Hyun;Lee, Seong-Rae;Cho, Won-Il;Cho, Byung-Won
    • Korean Journal of Materials Research
    • /
    • v.19 no.2
    • /
    • pp.73-78
    • /
    • 2009
  • This study investigated the dependence of the various sputtering conditions (Ar pressure: $2{\sim}10\;mTorr$, Power: $50{\sim}150\;W$) and thickness ($50{\sim}1200\;nm$) of Si thin film on the electrochemical properties, microstructural properties and the capacity fading of a Si thin film anode. A Si layer and a Ti buffer layer were deposited on Copper foil by RF-magnetron sputtering. At 10 mTorr, the 50 W sample showed the best capacity of 3323 mAh/g, while the 100 W sample showed the best capacity retention of 91.7%, also at 10 mTorr. The initial capacities and capacity retention in the samples apart from the 50W sample at 10 mTorr were enhanced as the Ar pressure and power increased. This was considered to be related to the change of the microstructure and the surface morphology by various sputtering conditions. In addition, thinner Si film anodes showed better cycling performance. This phenomenon is caused by the structural stress and peeling off of the Si layer by the high volume change of Si during the charge/discharge process.

The Market Effect of Additions or Deletions for KOSPI 200 Index : Comparison between Groups by Size and Market Condition (KOSPI 200지수종목의 변경에 따른 시장반응 : 규모와 시장요인에 따른 그룹간 비교분석)

  • Park, Young-S.;Lee, Jae-Hyun;Kim, Dae-Sik
    • The Korean Journal of Financial Management
    • /
    • v.26 no.1
    • /
    • pp.65-94
    • /
    • 2009
  • The event of change in KOSPI 200 Index composition is one of the main subjects for the test of EMH. According to EMH, when a certain event is not related with firm's fundamental value, stock price should not change after the announcement of news. This hypothesis leads us to the conclusion of horizontal demand curve of stock. This logic was questioned by Shleifer(1986) and argued that downward sloping demand curve hypothesis was supported. But Harris and Gruel(1986) found a different empirical evidence that price reversal occurs in the long run, which is called price pressure hypothesis. They argued that short term price effect by large block trading (price pressure) is offset in the long run because these event is unrelated to fundamental value. Therefor, they argued that EMH can not be rejected in the long run. Until now, there are two empirical studies with Korean market data in this area. Using a data with same time period of $1996{\sim}1999$, Kweon and Park(2000) and Ahn and Park(2005) showed that stock price or beta is not significantly affected by change in index composition. This study retested this event expanding sample period from 1996 to 2006, and analyzed why this event was considered an uninformative events in the preceding studies. We analyzed a market impact by separating samples according to firm size and market condition. In case of newly enlisted firm, we found the evidence supporting price pressure hypothesis on average. However, we found the long run price effect in the sample of large firms under bearish markets. At the same time, we know that the number of samples under the category of large firms under bearish markets is relatively small, which drives the same result of supporting the hypothesis that change in index composition is a non-informative event on average. Also, the long run price effect of large size firms under bearish markets was supported by the analyses using trading volumes. On the other hand, in case of delisting from the index, we found the long run price effect but that was not supported by trading volume analyses.

  • PDF

Evaluation of the Charcoal Tube Sampling Method for Carbon Disulfide in Air (활성탄관법을 이용한 공기중 이황화탄소 농도 측정법에 관한 연구)

  • Lee, Na Roo;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.22-36
    • /
    • 1993
  • This study was conducted to evaluate the charcoal tube sampling method for carbon disulfide in the air. Breakthrough was investigated according to flow rate, sampling time and air volume. Also the storage stability by storage method and time was investigated. The results are summarized as follows. 1. The samples stored at room temperature($28.2^{\circ}C$), refrigerator($3.8^{\circ}C$) and freezer($-15.6^{\circ}C$) were analyzed every week to five weeks. At one week storage at room temperature, 3.5% of $CS_2$ in the front section of the charcoal tube migrated into the back section and 57.7% at five weeks. The amount of $CS_2$ in the back section of the charcoal increased continuously by storage time. Migration of $CS_2$ was slow at refrigerator, and stopped occur at freezer. Recovery rate $CS_2$ was 52-82% at room temperature and 92-101% at refrigerator, based on the amount at freezer as a reference value. Thus loss was observed at room temperature. 2. When 6-48 L of fresh air were passed through tubes with spiked amounts of 0.379 and 0.759mg sample, the amounts of $CS_2$ in the back section of charcoal were 5.7-132.4 and 0-92% of the amount in the front section, respectively. The total recovery rates of$CS_2$ from 0.379 and 0.759mg spiked sample were 35.7-101.0% and 9l.3-100.1%, respectively. $CS_2$ loss was observed in 0.379mg spiked sample, but not in 0.759mg spiked sample. In the spiked samples, the amount of $CS_2$ in the back section of charcoal was not affected by flow rate when the air volume was controlled. The amount of $CS_2$ in the back section of charcoal increased over sampling time. And the faster the flow rate, the more the migration amount when the sampling time was the same. 3. A known concentration, 10 ppm of $CS_2$, was produced in a 200 L Tedlar bag. When the air volume was 24, 36, 48 L, breakthrough was 5.8, 16.9, 47.4%, respectively. The sampling flow rate of 0.05, 0.1, 0.2 Lpm did not change the breakthrough rate. Breakthrough increased over sampling time. And the faster the flow rate, the more the breakthrough, when the sampling time was the same.

  • PDF

Study on the Effective Focal Volume Change due to Light Intensity Using Fluorescence Correlation Spectroscopy (형광상관분광법을 이용한 광세기에 따른 유효 초점 부피 변화에 대한 연구)

  • Jeong, Chanbae;Lee, Jaeran;Kim, Sok Won
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.71-76
    • /
    • 2013
  • Using fluorescence correlation spectroscopy, we analyzed the change of effective focal volume of a confocal system with light intensity. The fluorescence correlation spectroscopy system was home-built in accordance with the He-Ne laser with a wavelength of 632.8 nm, and two kinds of samples (AlexaFluor657 and Quantum dot655) suitable for the wavelength of the laser beam were used. For each sample, we analyzed and compared the correlation functions obtained while changing the intensity of the light source in a range of 1~50 ${\mu}W$. The result shows that the radius of the focal area increases linearly through the increase of particle number and diffusion time in response to an intensity change in weak light below 10 ${\mu}W$. In the higher intensity region (>10~15 ${\mu}W$), the increasing rate of particle number and diffusion time keep increasing but at a much slower rate. Through this result, it was also found that the radius increasing rate of the focal area was reduced however, the radius still increased slightly.

Study on the Electrical Conductivity and Catalytic Property by Structural Change of 70V2O5-10Fe2O3-13P2O5-7B2O3 Glass with Crystallization

  • Jeong, Hwa-Jin;Cha, Jae-Min;Ryu, Bong-Ki
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.5
    • /
    • pp.406-412
    • /
    • 2017
  • $70V_2O_5-10Fe_2O_3-13P_2O_5-7B_2O_3$ glasses were prepared to study the electrical conductivity and catalytic properties of the structural change with crystallization. The structural changes were analyzed by determining the molecular volume from the sample density; using X-Ray Diffraction (XRD) analysis, which indicated that $V_2O_5$, $VO_2$ and $B_2O_3$ crystals in heat-treated more than 1h samples. Especially a new crystalline phase of non-stoichiometric $Fe_{0.12}V_2O_5$ was formed after 6 h heat treatment. The V-O bonding change after crystallization was analyzed by Fourier Transform Infrared Spectroscopy (FTIR); V ion change from $V^{5+}$ to $V^{4+}$ was shown by XPS. Conductivity and catalytic properties were examined based on the polaronic hopping of V and Fe ions, which exhibited different valence states with crystallization.

Study on the Accuracy of Vessel Measurement According to Table Object Distance Changes (혈관조영장비의 테이블-피사체간 거리 변화에 따른 혈관측정 정확도 연구)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.435-440
    • /
    • 2019
  • This is to study the accuracy of the actual size according to the TOD(table object distance; TOD) change when measuring blood vessels using angiography equipment, and to help the optimal selection of the device used accordingly. Balls similar to the size of common vessels were calibrated with TOD using 30 mm, 20 mm, 10 mm, 5 mm and acrylic phantoms, catheter calibration from 0 cm to 10 cm, 20 cm and 30 cm, respectively. It was measured whether there was a change in the measured value according to the change. The equipment used was GE Innova 3131 IQ equipment, and the image reconstruction method was GE AW4.7 post processing program. Two radiotechnologists were scanned three times by catheter calibration method and 3DRA(3dimension rotational angiography; 3DRA) volume rendering method. The independent sample T-test showed 0.981 (p> 0.05) to verify the significance between the two observers. As a result, in case of catheter calibration, the error rate at TOD 0 mm and 10 mm is within ± 10%, but when the TOD is changed to 20 mm and 50 mm respectively, the tolerance is ± 10% except for 30 mm ball exceeded. On the other hand, 3DRA was included within the tolerance range of ± 10% overall even when the TOD was changed from 0 mm to 50 mm. In the catheter calibration method, the larger the TOD, the larger the error range, and the 3DRA method was able to measure vascular vessels accurately close to the actual measurement without any consideration of the TOD.

Explosive mass-removal processes during high power nanosecond Nd-YAG laser ablation of silicon (나노초 야그 레이저 어블레이션에 의한 실리콘의 폭발적 제거 현상)

  • Jeong, S.H.;Yoo, J.H.;Grief, R.;Russo, R.E.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.736-742
    • /
    • 2000
  • Mass removed from crystalline silicon samples during high power single-pulse laser ablation was studied by measuring the resulting crater morphology with a white light interferometric microscope. The volume and depth of the craters show a strong nonlinear change as the laser irradiance increases across a threshold value, that is, approximately $2.2{\times}10^{10}\;W/cm^2$. Time-resolved shadowgraph images of the ablation plume show the ejection of large particulates from the sample for laser irradiance above the threshold, with a time delay of about 300-400 nsec. The thickness of superheated liquid layer near the critical temperature was numerically estimated, considering the transformation of liquid metal into liquid dielectric near the critical state (i.e., induced transparency). The estimated thickness of the superheated layer at a delay time of 200 nsec agreed with the measured crater depths, suggesting that induced transparency promotes the formation of a deep superheated liquid layer which leads to an explosive boiling responsible for the sudden increase of crater volume and depth.

  • PDF

Investigation of Fiber Distribution in Concrete Batches Discharged from Ready-Mix Truck

  • Sorensen, Christian;Berge, Egil;Nikolaisen, Eirik B.
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.4
    • /
    • pp.279-287
    • /
    • 2014
  • This paper presents the findings of an investigation of the fiber content variations in concrete being discharged from a ready-mix truck at the construction site. Concrete samples were extracted from the truck drums at the beginning, middle and end of discharge. Subsequently, fibers in each sample were separated from the concrete, and weighed. Presumably, synthetic macro fibers will float towards the top, i.e. towards the drum opening, of the inclined, revolving truck-drum, while, on the other hand, steel fibers will tend to gravitate towards the lower parts of the mixer drum. Accordingly, the discharge batch, containing synthetic macro fibers, will contain a higher amount of synthetic fibers per unit volume at the start of discharge than the average unit volume fiber content of the mix, and the content will gradually decrease further down the batch. The discharge batch of steel fiber concrete will contain fewer fibers per unit volume at the start of discharge than the average unit volume fiber content of the mix, and the content should gradually increase further down the batch. The correctness of the foregoing is partly confirmed. A certain percentage of the truck loads did not comply with the proposed requirements, mainly steel fiber reinforced batches, indicating the necessity of a code or guideline amendment. A change in the Norwegian shotcrete directive was made in 2011, based upon experimental research work (2010), which, in combination with the subsequent University of Life Sciences report (2012), constitutes the foundation of this article.

Preparation and Electrochemical Characterization of Si/C/CNF Anode Material for Lithium ion Battery Using Rotary Kiln Reactor (회전킬른반응기를 이용한 리튬이온전지용 Si/C/CNF 음극활물질의 제조 및 전기화학적 특성 조사)

  • Jeon, Do-Man;Na, Byung-Ki;Rhee, Young-Woo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.901-908
    • /
    • 2018
  • Graphite is used as a sample anode active material. However, since the maximum theoretical capacity is limited to $372mA\;h\;g^{-1}$, a new anode active material is required for the development of a high capacity lithium ion battery. The maximum theoretical capacity of Si is $4200mA\;h\;g^{-1}$, which is higher than that of graphite. However, it is not suitable for direct application to the anode active material because it has a volume expansion of 400%. In order to minimize the decrease of the discharge capacity due to the volume expansion, the Si was pulverized by the dry method to reduce the mechanical stress and the volume change of the reaction phase, and the change of the volume was suppressed by coating the carbon layers to the particle size controlled Si particles. And carbon fiber is grown like a thread on the particle surface to control secondary volume expansion and improve electrical conductivity. The physical and chemical properties of the materials were measured by XRD, SEM and TEM, and their electrochemical properties were evaluated. In this study, we have investigated the synthesis method that can be used as anode active material by improving cycle characteristics of Si.

Cryogenic Thermal Cycling Test on IGRINS cross-disperser VPH Grating

  • Jeong, Hyeon-Ju;Lim, Ju-Hee;Lee, Sung-Hoo;Deen, Casey;Pak, Soo-Jong;Yuk, In-Soo;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.156-156
    • /
    • 2011
  • VPH (Volume Phase Hologram) grating is one of the transmission gratings and is known as its remarkable efficiency (>90%). It has two different densities of gelatins causing interference patterns. The VPH grating is favored in many astronomical instruments these days and also IGRINS, which is up coming near infrared high-resolution spectroscope expected to see the first light next year, uses the VPH grating as its cross-disperser. The infrared astronomical instruments operate at cryogenic temperature (~100K) in order to cut down thermal noise and the optical components of IGIRNS will be operated at 130K. The VPH grating is sandwiched in between fused silica or glass and glued together using optical adhesive. IGRINS is expected to go through 50 times of thermal cycling in 10 years including the performance test and this research is to check whether the physical characteristic such as the adhesion or dichromatic gelatin does not break and change from the several cryogenic thermal cycling. The two identical test gratings provided from Kaiser Optical System, Inc. are used in this test. One VPH grating is cooled down to 100K for 2 hours with maximum dT/dt = 5 and warmed up to the room temperature and another grating is kept stored in the room temperature and used as a control sample. In order to check the change, we inspected the grating with eyes and checked its efficiency and transmission at the room temperature every 10 cycling. From the 40 times of cryogenic temperature cool down cycling, the VPH grating showed no signs of change within the error compared to the control sample. We concluded the VPH grating is durable through several cryogenic thermal cycling.

  • PDF