• Title/Summary/Keyword: Cervix Cancer

Search Result 366, Processing Time 0.019 seconds

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

The Clinical Significance of Follow Up SCC Levels in Patients with Recurrent Squamous Cell Carcinoma of the Cervix (재발성 자궁경부 편평상피암 환자들에서 Squamous Cell Carcinoma 항원의 유용성)

  • Choi Young Min;Park Sung Kwang;Cho Heung Lae;Lee Kyoung Bok;Kim Ki Tae;Kim Juree;Sohn Seung Chang
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.353-358
    • /
    • 2002
  • Purpose : To investigate the clinical usefulness of a follow-up examination using serum squamous cell carcinoma antigen (SCC) for the early detection of recurrence in patients treated for conical squamous cell carcinoma. Materials and Methods : 20 patients who were treated for recurrent cervical squamous cell carcinoma between 1997 and 1998, who had experienced a complete remission after radiotherapy and who underwent an SCC test around the time when recurrence was detected, were included in this study. The levels of SCC were measured from the serum of the patients by immunoassay and values less than 2 ng/mL were regarded as normal. The sensitivity of the SCC test for use in the detection of recurrence, the association between the SCC values and the recurrence patterns and the tumor size and stage, and the temporal relation between the SCC increment and recurrence detection were evaluated. Results : The SCC values were above normal in 17 out of 20 patients, so the sensitivity of the SCC test for the detection of recurrence was $85\%$, and the mean and median of the SCC values were 15.2 and 9.5 ng/mL, respectively. No differences were observed in the SCC values according to the recurrence sites. For 11 patients, the SCC values were measured over a period of 6 months before recurrence was detected, and the mean and median values were 13.6 and 3.6 ng/mL, respectively. The SCC values of 7 patients were higher than the normal range, and the SCC values of the other 4 patients were normal but 3 among them were above 1.5 ng/mL. At the time of diagnosis, the SCC valuess were measured for 16 of the 20 recurrent patients, and the SCC values of the patients with a bulky tumor $(\geq4\;cm)$ or who were in stage IIb or III were higher than those of the patients with a non-bulky tumor or who were in stage Ib or IIa. Conclusion : The SCC test is thought to be useful for the early detection of recurrence during the follow up period in patients treated for cervical squamous cell carcinoma. When an effective salvage treatment is developed in the future, the benefit of this follow-up SCC test will be increased.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Morphological Changes of Mouse Ovary by X-Ray Irradiation (방사선 조사선량에 따른 생쥐 난소의 형태학적 변화)

  • Yoon, Chul-Ho;Choi, Jong-Woon;Yoon, Surk-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.140-156
    • /
    • 2007
  • This research was performed to investigate the morphological changes of folliculus ovary according to the radiation dose. The whole body radiation of 200 cGy, 400 cGy, and 600 cGy was given to the each groups of 5 months-aged female mouse. Various staining methods used in this research are: Hematosylin-Eosin method, and immunohistochemistrical methods using BrdU, TUNEL, p53, p21, PCNA and inhibin. The minute structural changes of folliculus ovary were observed through an electron microscope with high magnification. The morphological changes of growing folliculus ovary became distinct as the dose of X-rays increased. Especially, the nuclei of granular cells showed manifest condensation and the changes of the transparent zone were distinct. As a result of histochemical reaction according to Masson's trichrome method and reticular fiber method, the changed granular cells, the deformed basilar membrane of folliculus ovary and the abnormal arrangement of the reticular fiber were observed. In the reaction of BrdU, the granular cells of normal folliculus ovary with positive reaction rapidly decreased according to the increase of the dose of X-rays. In TUNEL study, granular cells showing positive reaction in retarded folliculus ovary were expanded to growing folliculus ovary and primordial folliculus ovary according to the increase of the dose of X-rays. In case of 600 cGy of X-rays, oocyte underwent apoptosis. In p53 immunohistochemistry, p53 manifested to be stronger as the dose of X-rays increased. p53 reactivity was manifested distinctively in all cells comprising folliculus ovary following irradiation of 600 cGy. p21 was manifested in granular cells of folliculus ovary and showed very positive reaction around follicular antrum according to the increase of the dose of X-rays. In PCNA, positive reaction was manifested in growing folliculus ovary, mature folliculus ovary and primordial folliculus ovary, but the extent of the reaction decreased as the dose of the X-rays decreased. The finding that the reaction of granular cells around folliculus ovary was stronger than that near follicular membrane indicates that what was damaged first by X-ray was the cells near folliculus ovary and follicular antrum. The reactivity of $inhibin-{\alpha}$ showed difference according to the growing stage of folliculus ovary: $inhibin-{\alpha}$ showed the most strong reaction in mature folliculus ovary with follicular antrum. There was strong reaction in granular cells around follicular membrane but $inhibin-{\alpha}$ did not occur at all in theca cells comprising follicular membrane. $Inhibin-{\alpha}$ in ovary tissue exposed to 400 cGy of X-rays was manifested more strongly than in ovary tissue exposed to 600 cGy of X-rays, which was related to the phenomenon that granular cells of mature folliculus ovary underwent necrosis or apoptosis increasingly due to X-rays. In an electron microscope with high magnification, nuclei and protoplasm of granular cells in growing folliculus ovary abruptly underwent minute structural changes according to the increase of dose of X-rays. Cell residue, by-product of cell decease, neutrophil and macrophage around follicular antrum were observed. The minute structural changes in granular cells showed typical characteristics of apoptosis: the increase of electronic density due to nuclear condensation, fragmentation of nuclei and atrophy of protoplasm. Necrosis of cells was identified but it was not so remarkable. Macrophage with apoptotic bodies was scattered. Proportional to the radiation dose, we found that the generation of heterogeneous substance of normal ovary texture's follicular fluid, the emergence of dyeing characteristic in the basilar membrane of folicle, the generation of apoptosis, and the transformation of macrophages, etc. From this results, we can infer the possible radiation hazard on the ovary of cervix cancer patient with radiation therapy.

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.