• 제목/요약/키워드: Center cut

검색결과 941건 처리시간 0.023초

Application of Tumor Markers SCC-Ag, CEA, and TPA in Patients with Cervical Precancerous Lesions

  • Farzaneh, Farah;Shahghassempour, Shapour;Noshine, Bahram;Arab, Maliheh;Yaseri, Mehdi;Rafizadeh, Mitra;Alizadeh, Kamyab
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권9호
    • /
    • pp.3911-3914
    • /
    • 2014
  • Background: To determine the potential clinical utility of tumor markers CEA, TPA, and SCC-Ag for early detection of cervical precancerous lesions. Materials and Methods: A case-control study was carried out on 120 women (46 patients with histologically confirmed cervical precancerous lesions and 74 healthy controls). The significance of serum selected tumor markers in early detection of cervical intraepithelial neoplasia (CIN) were assessed. Results: Of the case group, the rates of CIN I, II, III, was 69.6%, 23.9%, and 6.5%, respectively. According to the manufacturer's cut-off values of 2ng/ml, 5ng/ml, and 70 U/ml for SCC-Ag, CEA and TPA tests, in that order, SCC-Ag test had a sensitivity of 13%, but CEA and TPA tests could not distinguish between case and control groups. The diagnostic sensitivities were highest at cut-off values of 0.55 ng/ml for SCC-Ag, 2.6ng/ml for CEA, and 25.5 U/ml for TPA which were 93%, 61%, and 50%, respectively. However, the area under the receiver operating characteristic curve was the largest for SCC-Ag (0.95 vs. 0.61 and 0.60 for CEA and TPA, respectively). Moreover, there was a highly significant direct correlation between SCC-Ag concentration and the degree of cervical precancerous lesions (r=0.847, p<0.001). Conclusions: The new cutoff of 0.5 for SCC-Ag test might be useful as a tumor marker in Iranian patients with CIN and it needs to be more evaluated by studies with larger populationa.

자동 분주기 Fixed Tip의 Carryover 방지를 위한 개선 방안 (The Prevention of Carryover in the Automated System With Fixed Tips)

  • 황보라;어두희;배진수;박종오;김지영;석재동
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.181-184
    • /
    • 2009
  • 목적 : 자동 분주기 (TECAN)의 fixed tip 사용 시 충분한 세척에도 불구하고 고농도 검체 뒤에 연이은 검체가 영향을 받는 carryover 현상이 발생되는 경우가 있다. 이는 검사결과가 위 양성으로 나타날 수 있는 위험성이 있으므로 이상유무 판단을 위해 잦은 재검을 실시해야 하는 번거로움이 있다. 따라서 본 연구는 경제성이 높은 fixed tip을 사용하면서 carryover를 방지할 수 있는 방법을 개선하고자 한다. 실험재료 및 방법 : 자동분주기(Tecan)를 이용하여 HBs Ag, HBs Ab, HBc Ab(IgG) 검사를 대상으로 실행하였으며, fixed tip 방식의 분주시스템으로 일반 환자의 검체 분주 후에 생리식염수를 분주 할 수 있도록 배치하였다. 세척 단계는 0.25mol/L NaOH용액을 이용하였으며, 생리식염수의 검사결과 cpm을 측정하여 carryover의 발생 유무를 확인하였다. 또한 3가지 검사를 0.25 mol/L NaOH 용액이 검사에 미치는 영향을 분석하였다. 결과 : 생리식염수 결과는 100% 음성결과를 보였으며, 0.25 mol/L NaOH를 세척액으로 사용한 fixed tip에서 검체분주 시 환자 혈청은 HBc Ab (IgG)검사에서 cut-off zone (cut-off${\pm}$10%)을 제외한 모든 결과에서 기존 외래보고 결과와 동일한 값을 얻었다. 결론 : 생리식염수 검사결과 100% 음성을 보인 것은 실험에서 사용한 세척액으로 fixed tip을 세척하는 방법이 carryover를 방지할 수 있고, 이로 인해 발생하는 위양성을 방지할 수 있었다. 또한, 환자 검체의 결과 값이 기존 보고 결과와 일치함으로 0.25 mol/L NaOH 용액이 간염 검사결과에 영향을 끼치지 않음을 확인하였다. 따라서 본 실험에서 실시한 방법이 disposable tip보다 상대적으로 경제적인 fixed tip을 사용하면서도 carryover가 없는 정확한 결과를 얻을 수 있는 효과적인 방안임을 알 수 있다.

  • PDF

Diagnostic Values of Serum Levels of Pepsinogens and Gastrin-17 for Screening Gastritis and Gastric Cancer in a High Risk Area in Northern Iran

  • Nejadi-Kelarijani, Fatemeh;Roshandel, Gholamreza;Semnani, Shahryar;Ahmadi, Ali;Faghani, Behzad;Besharat, Sima;Akhavan-Tabib, Atefeh;Amiriani, Taghi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7433-7436
    • /
    • 2014
  • Background: Gastric cancer (GC) is the second cause of cancer related death in the world. It may develop by progression from its precancerous condition, called gastric atrophy (GA) due to gastritis. The aim of this study was to evaluate the accuracy of serum levels of pepsinogens (Pg) and gastrin-17 (G17) as non-invasive methods to discriminate GA or GC (GA/GC) patients. Materials and Methods: Subjects referred to gastrointestinal clinics of Golestan province of Iran during 2010 and 2011 were invited to participate. Serum levels of PgI, PgII and G17 were measured using a GastroPanel kit. Based on the pathological examination of endoscopic biopsy samples, subjects were classified into four groups: normal, non-atrophic gastritis, GA, and GC. Receiver operating curve (ROC) analysis was used to determine cut-off values. Indices of validity were calculated for serum markers. Results: Study groups were normal individuals (n=74), non-atrophic gastritis (n=90), GA (n=31) and GC patients (n=30). The best cut-off points for PgI, PgI/II ratio, G17 and HP were $80{\mu}g/L$, 10, 6 pmol/L, and 20 EIU, respectively. PgI could differentiate GA/GC with high accuracy (AUC=0.83; 95%CI: 0.76-0.89). The accuracy of a combination of PgI and PgI/II ratio for detecting GA/GC was also relatively high (AUC=0.78; 95%CI: 0.70-0.86). Conclusions: Our findings suggested PgI alone as well as a combination of PgI and PgI/II ratio are valid markers to differentiate GA/GC. Therefore, Pgs may be considered in conducting GC screening programs in high-risk areas.

Acidic Pelvic Drainage as a Predictive Factor For Anastomotic Leakage after Surgery for Patients with Rectal Cancer

  • Yang, Liu;Huang, Xin-En;Xu, Lin;Zhou, Xin;Zhou, Jian-Nong;Yu, Dong-Sheng;Li, Dong-Zheng;Guan, Xin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권9호
    • /
    • pp.5441-5447
    • /
    • 2013
  • Purpose: To demonstrate the value of sequential determinations of pelvic drainage in the identification of increased risk of anastomotic leakage (AL) after anterior resection for rectal cancer with a double stapling technique. Patients and Methods: Between January 2004 and December 2011, data for the daily postoperative pH of pelvic drainage fluid in 753 consecutive patients with rectal cancer who initially underwent anterior resection with a double stapling technique were reviewed. All patients experienced a total mesorectal excision. Patients with anastomotic leakage (Group AL, n=57) were compared to patients without leakage (Group nAL, n=696). Patients with perioperatively abdominopelvic implants that were likely to affect pH value (determined at $25^{\circ}C$) other than leakage were excluded. Mean postoperative values were compared. Results: Anastomotic leakage was noted in 57 (7.6%) of 753 patients with rectal cancer. The diagnosis of AL was made between the $6^{th}$ and $12^{th}$ postoperative day (POD; mean $8^{th}$ POD). There was no significance of the daily average values of pH on POD1 & 2 in group AL while a significantly sharp declining mean pH value reached its diagnostic point of AL (p<0.001) on POD3. A cut-off value of 6.978 on the $3^{rd}$ POD maximized the sensitivity (98.7.0%) and specificity (94.7%) in assessing the risk of leakage. Conclusion: According to these results, an early and persistent declining of pH value of pelvic drainage fluid after rectal surgery with anastomosis, is a marker of AL. A cut-off value of 6.798 determined at $25^{\circ}C$ on POD3 maximizes sensitivity and specificity.

절화용 진한 주황색 아시아틱나리 신품종 '포인트' 육성 (Breeding of Lilium Asiatic Hybrids 'Point' for Cut Flower with Orange Red Colored Petals)

  • 서종택;유동림;남춘우;김수정;홍수영;류승열
    • 한국자원식물학회지
    • /
    • 제25권2호
    • /
    • pp.293-297
    • /
    • 2012
  • 절화용 아시아틱나리 신품종 '포인트(Point)' 품종은 2000년에 자생 하늘나리를 모본으로 하고 교잡계통중 주황색계통인 97-5계통을 부본으로 하여 교배하였다. 2005년~2008년까지 대관령에서 여름 시설재배를 통하여 생육 및 개화특성을 검정한 후 최종적으로 선발하여 '포인트(Point)'로 명명하였다. '포인트(Point)' 품종은 화색이 적색의 꽃봉오리를 지닌 오랜지 적색(O-R N30C)의 꽃이며 중심부로 반점이 있다. 암술은 갈색이고 수술은 진갈색이다. 개화기는 7월 8일이며 초장은 88.2 cm, 절화당 꽃수는 5.4개로 많다. 내화피장은 6.3 cm, 내화피폭이 3.2 cm로 대조품종 플라토보다 작은 꽃이다. 엽수는 12.2개이며 잎의 크기는 엽장이 9.2 cm, 엽폭이 1.1 cm로 좁고 짧았다. 구근무게는 24.6 g, 구주는 11.6 cm이다. 병에 대한 저항성은 강하며 개화기간은 16.1일로 길었고 기호도에 있어서도 4.1로 좋은 반응을 보였다.

The Validity and Reliability of a Screening Questionnaire for Parkinson's Disease in a Community

  • Kim, Jong-Hun;Cheong, Hae-Kwan;Lee, Chong-Sik;Yi, Sung-Eun;Park, Kun-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • 제43권1호
    • /
    • pp.9-17
    • /
    • 2010
  • Objectives: Parkinson's disease is one of the most common neurodegenerative diseases in the elderly population. In order to estimate the prevalence of Parkinson's disease in the community, the application of a good screening tool is essential. We evaluated the validity and reliability of a Parkinson's disease screening questionnaire and propose an alternative measure to improve its validity for use in community surveys. Methods: We designed the study in a three-phase approach consisting of a screening questionnaire, neurologic examination, and confirmatory examination. A repeated survey was administered to patients with disease detected in the community and on 150 subjects. We examined internal consistency using Cronbach's alpha test, test-retest reliability using the kappa statistic, and validity using sensitivity, specificity, and ROC curves. Unadjusted odds ratios were utilized for the estimation of weights for each questionnaire item. Results: The Cronbach's alpha of the questionnaire was 0.708. The kappa statistic for test-retest reliability was good to generally fair in most of the items. When newly proposed weighting scores were used, the optimum cut-off value was 7/8. When cut-off value was 5/6 for surveying prevalence in a community, the sensitivity was 0.98, and the specificity was 0.61, with simultaneous improvement in reliability. Conclusions: We recommend 5/6 as the ideal cut-off value for the survey of PD prevalence in community. This questionnaire designed for the Korean community could help future epidemiologic studies of PD.

개착사면의 구조적 특성과 파괴양상을 고려한 계측 해석 (Monitoring of Cut-Slope Behavior with Consideration of Rock Structure and Failure Mode)

  • 조태진;박소영;이상배;이근호;원경식
    • 터널과지하공간
    • /
    • 제16권6호
    • /
    • pp.451-466
    • /
    • 2006
  • DOM 시추코어에서 측정된 불연속면의 위치 및 방향성 자료를 이용하여 현장암반의 구조적 특성을 고려한 사면거동 해석이 가능하였다. 3차원 공간에서 설정된 절리들의 위치에 의거하여 붕락 현상이 발생된 개착사면의 추가적인 파괴양상을 예측하였으며, 개별 절리면의 붕락위해 가능성과 개착면 상에서의 trace 위치를 파악하여 세부적인 사면거동 양상을 파악하였다. 개착사면 횡단면에서 개별절리들의 파괴거동 양상과 사면체 블록형성을 대수학적으로 산출하여 사면 붕락심도를 규명하였다. 현장사면에 자동화 계측시스템을 설치하여 사면 거동에 대한 계측자료를 수집하였으며, DOM 시추공 내에 지중경사계를 설치하여 사면거동 양상을 횡단면 해석 결과와 대비시켜 분석하였다. 지중경사계를 이용하여 측정된 개착면의 표면변위 자료에 의거하여 사면 파괴시기를 예측할 수 있는 방법론을 고찰하였으며, 강우가 사면거동에 끼치는 영향성을 분석하였다.

적색 대륜 반겹꽃 절화용 다수성 거베라 신품종 "레드라인" (A New Gerbera Variety "Red Line"; High-yielding Cultivar with Red and Semi-double for Cut-flower)

  • 박상근;임진희;신학기;김미선;정향영;조해룡;이혜경
    • 한국육종학회지
    • /
    • 제41권4호
    • /
    • pp.591-594
    • /
    • 2009
  • 농촌진흥청 국립원예특작과학원에서는 2005년에 주황색 겹꽃 "Mirage"와 적색 반겹꽃 "Rose"를 교배하여 얻은 실생계통으로부터 2005년부터 2008년까지 4년 동안의 생육특성검정을 거쳐 화색이 밝고 선명한 흑심의 적색(RHS R44B) 반겹꽃을 선발하여 초세 강건한 절화용 거베라 신품종 "Red Line"을 품종육성하였다. 꽃의 직경은 12.7 cm, 외부설상화의 길이와 폭은 각각 5.83 cm와 1.27 cm인 대륜계통이며, 내화경과 화심장이 각각 8.10 cm와 2.80 cm 정도이다. 화형이 안정되고 화색과 화심색이 잘 조화되어 있으며, 화경이 튼튼하고 절화수량이 많아 재배농가 기호도가 높은 품종이다.

Silver thiosulfate 전처리와 에틸렌 처리가 절화 아이리스 '블루매직'의 수명에 미치는 영향 (Effect of Silver Thiosulfate Pretreatment and Ethylene Exposure on Vase Life of Cut 'Blue Magic' Iris Flowers)

  • 김영아;이종석
    • 화훼연구
    • /
    • 제18권3호
    • /
    • pp.151-156
    • /
    • 2010
  • 본 연구는 절화 아이리스의 노화와 절화수명에 미치는 에틸렌의 영향과 이러한 에틸렌의 작용을 억제할 수 있는 STS 전처리의 효과에 대하여 알아보고자 수행하였다. 아이리스는 1 mM STS 용액에 30분간 전처리한 후 0, $3mL{\cdot}L^{-1}$ 의 에틸렌에 24시간 노출시켰다. 봉오리 상태에서 절화 아이리스의 절화수명은 STS 전처리후 에틸렌에 노출된 것은 4.2일, 에틸렌에 노출되지 않았던 꽃은 4.6일 이었다. 반개화 상태에 수확한 아이리스의 절화수명은 STS 전처리에서 길었다. 그러나 에틸렌 노출에 의해서는 수명이 영향을 받지 않았다. 그러므로 절화 아이리스는 외생 에틸렌에 민감하지 않음을 알 수 있었다. 봉오리 상태에서 수확한 절화는 완전한 개화가 유도되지 않고 노화가 일어나는 경우가 많으므로 어느 정도 개화가 진전된 꽃을 수확하는 것이 필요한 것으로 판단되었다.

가시가 적은 분홍색 장미 '노블아이' 육성 (Breeding of a Pink Rose Cultivar 'Noble Eye' with Few Prickles for Cut Flower)

  • 기광연;황인택;조경철;윤봉기;최경주;이재신;한태호
    • 화훼연구
    • /
    • 제18권4호
    • /
    • pp.299-302
    • /
    • 2010
  • 절화장미 '노블아이' 품종은 전라남도농업기술원에서 육성한 분홍색 스탠다드 품종으로 수세가 강하고 화형이 예쁜 분홍색 '노블레스'를 모본으로, 분홍색이며 다수성인 '프리티우먼'을 부본으로 하여 2003년에 인공교배 하였다. 2006년부터 2009년까지 3회의 특성조사와 생산력검정을 실시하여 화형이 예쁘고 수량성이 우수한 '노블아이' 품종을 육성하였다. 스탠다드 대형계 품종으로 화색이 분홍색이며 가시가 적고 꽃잎수는 40.5매로 절화수명이 9.4일이었다. 또한 절화수량은 125.7본/$m^2$/년으로 대비품종 '노블레스' (110.4본/$m^2$/년)에 비해 14% 증수되었다. '노블아이' 품종은 묘번식이 잘되며 소비자 기호도 평가에서 대비품종에 비해 좋은 평가를 받았다.