• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.041 seconds

Design of CFD Structured Microstrip Line Bandpass Filter (CFD 구조의 마이크로스트립 라인 가변 대역통과필터 설계)

  • Yoon, Giwan;Chai, Dongkyu;Linh, Mai;Yim, Munhyuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1292-1296
    • /
    • 2002
  • In this paper, a 3-coupled microstrip line tunable bandpass filter has been designed on the basis of a tonductoriFerroelectricfDielectric (CFD) structure. This tunable filter basically exploits the fact that the increase in the bias voltage leads to the reduction of the effective dielectric constant (eon). This reduced $\varepsilon$eff shifts the center frequency (fc) to the higher value. The characteristics of designed filter are as follows; Return loss (RL) is larger than 10 dB; Insertion loss (IL) is les.i than 3.5 dB: 3-dB bandwidth (BW) is less than 1.18 GHz fc can be tuned from 25.4 GHz to 28.8 GHz over the variation of $\varepsilon$eff, from 10 to 13. Therefore, the tunability comes up to 3.4 GHz. The dimension of the filter designed is 7.0 mm ${\times}$ 5.0 nm ${\times}$ 0.5 mm.

Design of a Broad Band-pass Filter with Stubs for Harmonics Suppression using the FSCS (FSCS를 이용한 고조파가 억제된 광대역 스터브 대역통과 여파기의 설계)

  • Choi, Young-Gu;Kim, Bok-Ki
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.1
    • /
    • pp.103-109
    • /
    • 2008
  • In this papaer, a new type of ${\lambda}_g/4$ short stub band pass filter and ${\lambda}_g/2$ open stub band pass filter are purposed. Both are designed using FSCS technique for harmonic suppression. The proposed filters that used FSCS technique and a broadband stop filter is integrated to band pass filter to suppress the harmonics. The BSF are also placed between stubs so that the size is larger than prevent as compared to conventional one. The propose filters have center frequency of 5.8 GHz, bandwidth of 50% and harmonics suppressin is 120% has in bandwith. The measurement results in the case of ${\lambda}_g/4$ short stub filter, insertion loss of 0.5 dB, return loss of 14 dB are achieved and in the case of ${\lambda}_g/2$ open stub filter, loss of 0.8 dB, return loss of 14.4 dB are achieved. The simulation results and the measurement results are almost the same.

Improvement in Thermomechanical Reliability of Power Conversion Modules Using SiC Power Semiconductors: A Comparison of SiC and Si via FEM Simulation

  • Kim, Cheolgyu;Oh, Chulmin;Choi, Yunhwa;Jang, Kyung-Oun;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.21-30
    • /
    • 2018
  • Driven by the recent energy saving trend, conventional silicon based power conversion modules are being replaced by modules using silicon carbide. Previous papers have focused mainly on the electrical advantages of silicon carbide semiconductors that can be used to design switching devices with much lower losses than conventional silicon based devices. However, no systematic study of their thermomechanical reliability in power conversion modules using finite element method (FEM) simulation has been presented. In this paper, silicon and silicon carbide based power devices with three-phase switching were designed and compared from the viewpoint of thermomechanical reliability. The switching loss of power conversion module was measured by the switching loss evaluation system and measured switching loss data was used for the thermal FEM simulation. Temperature and stress/strain distributions were analyzed. Finally, a thermal fatigue simulation was conducted to analyze the creep phenomenon of the joining materials. It was shown that at the working frequency of 20 kHz, the maximum temperature and stress of the power conversion module with SiC chips were reduced by 56% and 47%, respectively, compared with Si chips. In addition, the creep equivalent strain of joining material in SiC chip was reduced by 53% after thermal cycle, compared with the joining material in Si chip.

Comparison of Carcass Characteristics and Meat Quality between Duroc and Crossbred Pigs

  • Choi, Jung-Seok;Lee, Hyun-Jin;Jin, Sang-Keun;Choi, Yang-Il;Lee, Jae-Joon
    • Food Science of Animal Resources
    • /
    • v.34 no.2
    • /
    • pp.238-244
    • /
    • 2014
  • This study was conducted to compare the carcass characteristics and meat quality characteristics of Duroc breed and crossbred pigs (Landrace ${\times}$ Yorkshire ${\times}$ Duroc, LYD). Duroc and crossbred pigs did not show differences in carcass characteristics. Crossbred pigs had higher moisture and protein content than Duroc breeds. However, Duroc breeds had a higher fat content than the crossbred pigs. In meat quality characteristics, crossbred pigs showed higher values of drip loss and cooking loss over Duroc breeds, while Duroc breeds showed higher ultimate pH value compared to that of crossbred pigs. However, there were no differences in water holding capacity and shear force value. In myoglobin content, crossbred pigs had higher content compared to that in the Duroc population. In subjective evaluation and sensory characteristics, Duroc breeds showed significantly higher scores in all categories except for tenderness over the crossbred pigs. However, in storage characteristics, Duroc breeds showed reduced tendency relative to crossbred pigs. Crossbred pigs had higher unsaturated fatty acid content than Duroc breeds did. In these results, Duroc breeds showed excellent meat quality characteristics with its higher intramuscular fat content and pH value, lower drip loss and cooking loss and higher juiciness and flavor, compared to the crossbred pigs.

The Effect of Knee Strategy on Limits of Stability in Standing Balance (기립균형시 슬관절 전략이 안정성 한계에 미치는 영향)

  • Kwon, Hyuk-Cheol;Jeong, Dong-Hoon
    • Physical Therapy Korea
    • /
    • v.6 no.3
    • /
    • pp.11-21
    • /
    • 1999
  • Human balance is maintained through a complex process involving sensory detection of body motions, integration of sensorimotor information within the central nervous system, and execution of appropriate musculoskeletal responses. The basic task of balance is to position the body center of gravity (COG) over some portion of the support base. When the COG extends beyond the base of support, the person has exceeded the limits of stability (LOS). At this point, a step or stumble is required to prevent a fall. Automatic postural responses operate to keep the COG over the base of support. They are a set of functionally organized, long-loop responses that act to keep the body in a state of equilibrium. There are four commonly identified automatic postural responses, or strategies. These are ankle strategy, hip strategy, suspensory (knee) strategy, and stepping strategy. Thus, the purpose of this study was to evaluate the LOS using various knee strategies. Forty subjects participated in this study. The subjects were comprised of 20 males and 20 females who were without neurologic, orthopaedic or balance performance impairments. The LOS was measured with a Balance Performance Monitor (BPM) Dataprint Software Version 5.3. The results of this study were as follows: 1) Knee joint angle which is to increase stability of standing balance with using knee strategy was at mid-range. 2) There were statistically significant differences in anteroposterior LOSs according to the knee strategy. 3) There were no statistically significant differences in mediolateral LOSs according to the knee strategy. 4) There were statistically significant differences of anteroposterior LOSs with using knee strategy according to gender. 5) There were no statistically significant differences in mediolateral LOSs with using knee strategy according to gender.

  • PDF

Reduced sulfur gas loss in the bag sampling procedure - Comparison by calibration slope values (악취황 성분의 채취와 샘플백 내부의 시료 유실율 비교: 검량선의 기울기를 이용한 평가)

  • Kim, K.H.;Choi, Y.J.;Ahn, J.W.
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.338-343
    • /
    • 2005
  • In this work, sample loss of reduced sulfur compounds (RSC) was investigated with respect to bag sampling techniques. For comparison purpose, calibration slopes were obtained by analyzing standards prepared by 'within syringe dilution' (WSD) method against those made either by 'Tedlar bag dilution' (TBD) or by 'polyester aluminum bag dilution' (PBD) method. The results indicated that the recovery rate of TBD showed the mean values of about 87%, while those of PBD about 77%. Despite the fact that sample loss is inevitable, precise sampling of reduced sulfur compounds may still be possible, if one acknowledges and be prepared for such loss rates of bag sampling methods.

Convective Heat Loss from Solar Tower Receiver with Tilt Angles and Operating Conditions (Solar Tower용 흡수기의 설치 각도 및 작동 조건 변화에 따른 대류 열손실 분석)

  • Kang, Kyung-Mun;Lee, Ju-Han;Kim, Yong;Seo, Tae-Beom;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.121-128
    • /
    • 2007
  • Convective heat loss from solar tower receiver is experimentally investigated in wind tunnel with tilt angles and operating conditions. In order to simulate the receiver, an electric heater, which is made of aluminum (width : 100 mm, height : 100mm) is used and installed in the wind tunnel. The convective heat loss from the receiver is dependent on the direction and the velocity of the wind and the surface temperature of the receiver. The tilt angle and surface temperature of the receiver are varied from 0o (cavity facing straight down) and 90o(cavity aligned horizontally) and from $150^{\circ}C$ to $250^{\circ}C$, respectively. Also, the wind speed is changed from 0 to 4m/s. The convective heat loss is obtained by measuring consumed power to the heater to maintain the desired surface temperature. It is concluded that Nusselt number increases with increasing wind speed for all cases. Especially, it is showed that Nusselt number can be maximized when the tilt angle is 30o.

Acute and Chronic Isolated Splenic Torsion in Two Dogs (개에서 단독으로 발생한 급성 비장 염전과 만성 비장 염전의 비교)

  • Jung, Joo-Hyun;Chae, Woong-Joo;Chang, Jin-Hwa;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.52-57
    • /
    • 2008
  • An intact male, 3-year old, Sapsari, weighing 29 kg with a history of respiratory distress, anorexia, abdominal distension, and depression for 1 day was referred. Radiographic findings included a C-shaped soft tissue mass in the mid-abdominal cavity and loss of serosal detail. Ultrasonographs showed splenomegaly with hypoechoic coarse parenchyma, loss of venous flow in the dilated splenic veins, and thrombi. Based on image findings, acute isolated splenic torsion was diagnosed. Splenectomy and prophylactic gastropexy was performed. Another case was a spayed female, 8-year old, Shih-tzu, weighing 3.7 kg with a history of intermittent abdominal pain and a palpable abdominal mass for 1 year. Radiographic findings showed splenomegaly characterized by a soft tissue round mass. Ultrasonographs revealed displaced splenic hilum and absence of venous flow in the dilated splenic vein. Chronic isolated splenic torsion was diagnosed and also splenectomy and gastropexy was performed. Two dogs were recovered normally after surgery without any complications. Acute form of isolated splenic torsion showed acute systemic clinical signs, severe C-shaped splenomegaly on radiographs, and loss of all of splenic venous flow, perivenous hyperechoic triangle sign, and thrombi on ultrasonographs. Chronic form of isolated splenic torsion showed chronic obscure clinical signs, moderate splenomegaly on radiographs, and partial loss of splenic venous flow on ultrasonographs.

Design of a 5.8 GHz Narrow Band-pass Filter with Harmonics Suppression (고조파가 억제된 5.8 GHz 협대역 대역통과 여파기)

  • Yoon, Ki-Cheol;Lee, Jong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2A
    • /
    • pp.167-173
    • /
    • 2008
  • In this paper, the flexible narrow bandpass filters (BPFs) with ${\lambda}$g/4 short and ${\lambda}$g/2 open stubs by microstrip line on duroid substrate are suggested. These BPFs with narrow bandwidth show flexible bandwidth with variation of the position of the stubs using the Qe (external quality factor) without changing the impedance value at microwave range. On the other hand, by replacing the series quarter-wavelength connecting lines with the equivalent T-shaped line of bandstop filter(BSF), the compact stub bandpass filter with harmonics suppression can be realized. The BPF with ${\lambda}$g/4 short stubs shows the insertion loss of 2.1 dB and the return loss of 18 dB and BPF with ${\lambda}$g/2 open stubs shows the insertion loss of 1.2 dB and the return loss of 21.9 dB at the center frequency of 5.8 GHz and the bandwidth of 10 %.

Logistic Regression and GIS based Urban Ground Sink Susceptibility Assessment Considering Soil Particle Loss (토립자 유실을 고려한 로지스틱 회귀분석 및 GIS 기반 도시 지반함몰 취약성 평가)

  • Suh, Jangwon;Ryu, Dong-Woo;Yum, Byoung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.2
    • /
    • pp.149-163
    • /
    • 2020
  • This paper presents a logistic regression and GIS based urban ground sink susceptibility assessment using underground facility information considering soil particle loss. In the underground environment, the particle loss due to water flow or groundwater level change leads to the occurrence and expansion of cavities, which directly affect the ground sink. Four different contributory factors were selected according to the two underground facility domains (water pipeline area, sewer pipeline area) and subway line area. The logistic regression method was used to analyze the correlation and to derive the regression equation between the ground sink inventory and the contributory factors. Based on these results, three ground sink susceptibility maps were generated. The results obtained from this study are expected to provide basic data on the area susceptible to ground sink and needed to safety monitoring.