• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.036 seconds

A New D-dimer Cutoff Value to Improve the Exclusion of Deep Vein Thrombosis in Cancer Patients

  • Chen, Chong;Li, Gang;Liu, Yun-De;Gu, Ya-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1655-1658
    • /
    • 2014
  • Objective: To find a more appropriate alternative to D-dimer cutoff value for the diagnosis of deep vein thrombosis (DVT) in cancer patients. Methods: A total of 711 cancer patients with symptoms suspicious of DVT were included in the study. D-dimer levels were assessed using ELISA. All patients were subjected to imaging procedures. Results: Among 711 patients with cancer, 466 (65.5%) were females and 245 (34.5%) were males, with an average age of $57.3{\pm}13.23$ years. The mean age in the DVT group was significantly higher than in the non-DVT group (P<0.05). The D-dimer levels of the DVT group were significantly higher than those of the non-DVT group (P<0.05). The incidence rate of DVT varied significantly according to cancer type (P<0.05). Increasing age and lung cancer were significantly correlated with D-dimer levels (P<0.05), and a one-year increase in age was associated with a 14.28 ng/ml increase in the D-dimer value. The optimal cutoff point for D-dimer was found to be 981 ng/ml, with a sensitivity of 86.4%, specificity of 79.4%, and accuracy of 82.6%. If the D-dimer cutoff point was set to 981ng/ml, the specificity would increase from 61.8% to 85.5% without loss of sensitivity in patients aged 40 years or younger. In patients aged more than 40 years, the new cutoff almost doubled the specificity with slightly reduced sensitivity. Conclusion: In cancer patients, a new cutoff value of 981 ng/ml effectively improved the exclusion of DVT, especially for patients aged more than 40 years.

Clinical Efficacy and Prognostic Factors of Chemoreduction Combined with Topical Treatment for Advanced Intraocular Retinoblastoma

  • Liu, Yan;Zhang, Xi;Liu, Fang;Wang, Ke-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7805-7809
    • /
    • 2014
  • Objective: To explore the clinical efficacy and prognostic factors of chemoreduction combined with topical treatment of advanced intraocular retinoblastoma (RB). Materials and Methods: A total of 22 eyes from 17 children with RB were selected for the study and treated with chemoreduction combined with topical cryotherapy, transpupillary thermotherapy (TTT) or episcleral plaque brachytherapy. Clinical and follow-up data were retrospectively analyzed. Results: All children received 2~6 courses of chemoreduction treatment, ($4.5{\pm}0.8$ courses on average); 17 eyes from 13 children were treated by chemoreduction combined with cryotherapy or TTT and 5 eyes from 4 children with chemoreduction combined with $^{125}I$ episcleral plaque brachytherapy. The eye retention rate was 81.8% (18/22), among which 38.9% (7/18) featured restored or maintained good vision. Postoperative follow-up period was 7 to 34 months, ($18.6{\pm}5.2$ months on average). The recurrence rate was 41.2% (7/17), among which 57.1% (4/7) were controlled by supplementing or appending cryotherapy or TTT treatment during the follow-up period. The tumor basal diameter and thickness were significantly reduced (P<0.05 or P<0.01) after treatment. All children demonstrated different degrees of hair loss, 70.6% (12/17) with different degrees of gastrointestinal reactions, 5.88% (1/17) with neutropenia and 11.8% (2/17) being seriously infected during the chemotherapeutic treatment. Univariate and logistic regression analysis showed that tumor basal diameter before treatment had a significant effect on the prognosis (P<0.01). Conclusions: Chemoreduction combined with topical therapy can effectively control RB in the short term, and tumor basal diameter before treatment is an independent risk factor for prognosis.

Design and Fabrication of Circularly Polarization Antenna for Electronic Toll Collection System (ETCS용 원형편파 안테나의 설계 및 제작)

  • Lee, Sang-Mok;Yoon, Joong-Han;Kim, Heung-Soo
    • Journal of IKEEE
    • /
    • v.6 no.1 s.10
    • /
    • pp.40-46
    • /
    • 2002
  • In this paper, a microstrip array antenna is designed, fabricated and measured for ETCS(Electronic Toll Collection System). To reduce effect of external propagation environment, we use edge-cuffed element and to obtain wider axial ratio and increased bandwidth, we use the sequential rotation array method. Also to fulfill ETCS, roadside equipment are designed to be provide a radiation pattern which can accurately pinpoint the designated communication area without interference of another lanes. And we make and apply an absorber to the array antenna to reduce SLL(Side Lobe Level). From the measurement, we get that return-loss at center frequency is -20.675dB, axial ratio is 0.35dB and the gain is 20.26dBi. And we found that SLL is reduced.

  • PDF

Process Technology of the Direct Separation and Recovery of Iron and Zinc Metals Contained in High Temperature EAF Exhaust Gas

  • Furukawa, Takeshi;Sasamoto, Hirohiko;Isozaki, Shinichi;Tanno, Fumio
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.393-397
    • /
    • 2001
  • The innovatory process, that is the direct separation and recovery of the iron and zinc metals contained in the high temperature exhaust gas generated from the electric arc furnace fer the inn scrap melting and/or the dust treatment, has been proposed. This proposed process consists of the moving coke bed filter that is directly connected to the electric furnace, and the following heavy metal condenser. The exhaust gas passes through the filter and the condenser right after exhausting from the electric furnace. The moving coke bed filter is being controlled at about 1000℃ and collects iron and slag components contained in the high temperature exhaust gas. Heavy metals such as zinc and lead pass through the filter as vapor. Based on the thermodynamic considerations, the iron oxide and the zinc oxide are reduced in the filter. The solution loss reaction rate is comparatively low at about 1000℃ in the coke bed filter by the analysis using the mathematical simulation model. The heavy metal condenser is installed in the position after the coke bed filter, and rapidly cools the gas from about 1000℃ to 450℃ by a full of the cooling medium like the solid ceramic ball in addition to the cooling from the wall. The zinc and lead vapor condense and separate f개m the gas in a liquid state. The investigation of the characteristics of the exhaust gas of the commercial electric arc furnace, the fundamental experiments of the laboratory scale and the bench scale ensured the formation of this proposed process. A small-scale pilot plant examination is carrying out at present to confirm the formation of the process. It is certain that the dust generation of the electric arc furnace is extremely decreased, and it can save the energy consumption of usual dust treatment processes by the realization of this process.

  • PDF

Design and Fabrication of the Dipole-Fed Planar Array Antenna at X-Band (X밴드용 다이폴 급전 평면배열 안테나 설계 및 제작)

  • Mun, Seong-Ik;Yang, Du-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.5
    • /
    • pp.251-258
    • /
    • 2002
  • In this paper, the dipole-fed planar array antenna applied Yagi-Uda antenna away theory to microstrip antenna is designed and fabricated at X-band. The design procedure of the dipole-fed planar array antenna with the wide bandwidth is presented to be easily practiced to a wireless communication system. The radiation pattern, return loss and bandwidth of the antenna are improved by the finite differential time domain(FDTD) numerical method. The propriety of analysis of planar dipole antenna is proved from the measured data. From the measured results, the antenna maximum gain is 4.9dBi at center frequency of 10GHz and frequency bandwidth is about 40%. Front-to-back ratio is 16dB, and half-power beam-width of E-plane and H-plane are 117$^{\circ}$and 156$^{\circ}$, respectively. When VSWR of antenna is less than 2, the measured results are agreed well with the theoretical values in the frequency range from 7.4GHz to 11.88GHz.

Comparison of Performance Analysis of the Ventilated and Non-­ventilated CIGS BIPV Units (환기 유무에 따른 CIGS BIPV 커튼월 유닛의 성능 비교 분석)

  • Kim, Sang-Myung;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.47-57
    • /
    • 2017
  • CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was $6.8^{\circ}C$ lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

Preparation and Properties of Polybenzoxazole Copolymers Bearing Pendants and Imide Ring in the Main Chain

  • Lee, Seul Bi;Lee, Eung Jae;Choi, Jae Kon
    • Elastomers and Composites
    • /
    • v.51 no.3
    • /
    • pp.195-205
    • /
    • 2016
  • A series of aromatic poly(hydroxyamide)s (PHAs) containing varying oligo(oxyethylene) substituents and 1,3-phenylene imide ring unit in the main chain were synthesized by the direct polycondensation reaction. The inherent viscosities of the PHAs exhibited in the range of 0.89~1.12 dL/g in DMAc or DMAc/LiCl solution. The PH-2~5 copolymers were easily soluble in strong aprotic solvents: DMAc, NMP, DMSO etc. and the PH-5 copolymer was soluble in less polar solvents such as m-creasol and pyridine with LiCl salt on heating. However, all PBOs were quite insoluble in other solvents, but only partially soluble in sulfuric acid. All copolymers (PH-2~5) could afford the flexible and tough films by solution casting. We identified that the PHAs were converted to the PBOs by the thermal cyclization reaction in the range of $200{\sim}380^{\circ}C$. The 10% weight loss temperatures and char yields of the PBOs were recorded in the range of $382{\sim}647^{\circ}C$ and 38.7~73.1% values at $900^{\circ}C$. The tensile strength and initial modulus of the PH-5 in the copolmers showed the highest values of 2.46 GPa and 49.55 MPa, respectively. The LOI values of the PHAs were in the range 26.6~29.0%, and increased with increasing 1,3-phenylene imide ring unit.

Survival Rate and Hematological Responses with Temperature Changes of Red Spotted Grouper, Epinephelus akaara in South Korea

  • Park, Jong Youn;Han, Kyeong Ho;Cho, Jae Kwon;Kim, Kyong Min;Son, Maeng Hyun;Park, Jae Min;Kang, Hee Woong
    • Development and Reproduction
    • /
    • v.20 no.2
    • /
    • pp.81-90
    • /
    • 2016
  • The effect of sudden changes of water temperature (WT) on the survival rate and physiological responses of the red spotted grouper (Epinephelus akaara) were examined by manipulating WT control system for 9 days. Experimental condition was divided in two different regimes at low (from $10^{\circ}C$ to $4^{\circ}C$, decreased $1^{\circ}C/d$) and high (from $28^{\circ}C$ to $34^{\circ}C$, increased $1^{\circ}C/d$) WT. Survival rate of experimental fishes were observed, and determined the changes of hematological characteristics by analyzing plasma levels of cortisol, glucose, total protein, and electrolytes ($Na^+$, $Cl^-$, $K^+$). No mortality was observed until low WT $6^{\circ}C$ (144 h) and high WT $32^{\circ}C$ (96 h), and 100% mortality was observed at low WT $4^{\circ}C$ (216 h) and high WT $35^{\circ}C$ (171 h). Plasma levels of cortisol and glucose increased rapidly as decreasing WT, and the loss of swimming ability and respiration response was observed at low WT $7^{\circ}C$ and high WT $34^{\circ}C$ conditions.

The Anconeus Muscle Free Flap: Clinical Application to Lesions on the Hand

  • Jeon, Byung-Joon;Jwa, Seung Jun;Lee, Dong Chul;Roh, Si Young;Kim, Jin Soo
    • Archives of Plastic Surgery
    • /
    • v.44 no.5
    • /
    • pp.420-427
    • /
    • 2017
  • Background It can be difficult to select an appropriate flap for various defects on the hand. Although defects of the hand usually must be covered with a skin flap, some defects require a flap with rich blood supply and adequate additive soft tissue volume. The authors present their experience with the anconeus muscle free flap in the reconstruction of various defects and the release of scar contractures of the hand. Methods Ten patients underwent reconstruction of the finger or release of the first web space using the anconeus muscle free flap from May 1998 to October 2013. Adequate bed preparations with thorough debridement or contracture release were performed. The entire anconeus muscle, located at the elbow superficially, was harvested, with the posterior recurrent interosseous artery as a pedicle. The defects were covered with a uniformly trimmed anconeus muscle free flap. Additional debulking of the flap and skin coverage using a split-thickness skin graft were performed 3 weeks after the first operation. Results The average flap size was $18.7cm^2$ (range, $13.5-30cm^2$). All flaps survived without significant complications. Vein grafts for overcoming a short pedicle were necessary in 4 cases. Conclusions The anconeus muscle free flap can be considered a reliable reconstructive option for small defects on the hand or contracture release of the web space, because it has relatively consistent anatomy, provides robust blood supply within the same operative field, and leads to no functional loss at the donor site.

Viscoelastic behavior of aqueous surfactant micellar solutions

  • Toshiyuki Shikata;Mamoru Shiokawa;Shyuji Itatani;Imai, Shin-ichiro
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.3
    • /
    • pp.129-138
    • /
    • 2002
  • A cationic surfactant, cetyltrimethylammonium $\rho$-toluenesufonate (CTA$\rho$TS), forms long threadlike micelles in aqueous solution. The threadlike micelles make concentrated entanglement networks, so that the solution shows pronounced viscoelastic behavior as concentrated polymer systems do. However, a mechanism for a process responsible for the longest relaxation time of the threadlike micellar system is different from that of semi-dilute to concentrated polymer systems. The threadlike micellar system exhibits unique viscoelasticity described by a Maxwell model. The longest relaxation time of the threadlike micellar system is not a function of the concentration of CTA$\rho$TS, but changes with that of $\rho$-toluenesufonate ($\rho$$TS^{-}$) ions in the bulk aqueous phase supplied by adding sodium $\rho$-toluenesulfonate (NapTS). The rates of molecular motions in the threadlike micelles are not influenced by the concentration of $\rho$$TS^{-}$ anions, therefore, molecular motions in the threadlike micelles (micro-dynamics) are independent of the longest relaxation mechanism (macro-dynamics). A nonionic surfactant, oleyldimethylamineoxide (ODAO), forms long threadlike micelles in aqueous solution without any additives. The aqueous threadlike micellar system of ODAO also shows Maxwell type viscoelastic behavior. However, the relaxation mechanism for the longest relaxation process in the system should be different from that in the threadlike micellar systems of CTA$\rho$TS, since the system of ODAO does not contain additive anions. Because increase in the average degree of protonation of head groups of ODAO molecules in micelles due to adding hydrogen bromide causes the relaxation time remarkably longer, changes in micro-structure and micro-dynamics in the threadlike micelle are closely related to macro-dynamics in contrast with the threadlike micellar system of CTA$\rho$TS.