• 제목/요약/키워드: Center Loss

Search Result 3,752, Processing Time 0.034 seconds

A Study on the Oil Film Behaviors of Pin Bush Bearings for Diesel Engines with Various Engine Oil Viscosities (오일점도에 따른 디젤엔진용 핀부시 베어링의 유막거동에 관한 연구)

  • Kim, Chung-Kyun;Lee, Byoung-Kwan
    • Tribology and Lubricants
    • /
    • v.24 no.1
    • /
    • pp.21-26
    • /
    • 2008
  • A pin bush bearing is one of the most important element in the piston engine which is joined a piston to a connecting rod. A pin bush is suffered by heat and changeable repeat loads, which are come from the explosive gas heat and pressures during a reciprocating stroke. Therefore, a tribological behavior of pin bush bearings is very severe compared to other parts of a piston assembly. To keep a stable operation of pin bush bearings effectively, it would be satisfied with proper oil film strength for severe operating conditions and durability, which are strongly related to the oil film thickness, oil film pressure, and a friction loss power. The computed results show that the viscosity of engine oils slightly affects to the minimum oil film thickness and oil film pressure distribution, but is an influential parameter on a total friction loss power. Thus the low viscosity engine oils for an increased operation condition should select a high level of base oil and add a viscosity index improver as an oil film additive.

The Effect of Management Program of Oriental Medicine for Obesity Control on Overweight and Obese Pediatrics (과체중.비만 소아에 대한 한방비만치료프로그램 효과)

  • Lee, Yoon-Jae;Ryu, Eun-Kyung
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2009
  • Objectives The purpose of this study was to investigate the effect of oriental treatment on pediatric overweight and obesity. Methods From the December 2006 to the May 2008, 19 children were treated of obesity control in J Korean Hospital, electrolipolysis, auricular acupuncture was done 2 times per week for 4 weeks with the consulting of diet and exercise. Nine children were treated for 9 weeks. We checked the change of weight at treatment time and the body composition measured by bioelectrical impedance analysis(BIA) per 2 weeks. Results After 4 weeks treatment, the weight loss was 2.67${\pm}$1.75kg. And after 9 weeks treatment, the weight loss of 9 children was 5.91${\pm}$2.73kg. Total fat mass measured by BIA significantly decreased 2.38${\pm}$1.19kg after 4 weeks. BMI and the weight loss of children were significantly correlated. After 4 weeks treatment the BMI significantly decreased 1.43${\pm}$0.89kg/m$^2$. After 8 weeks treatment the BMI of 9 children significantly decreased 3.31${\pm}$1.47kg/m$^2$. Conclusions The pediatric obesity could be effective treated by herdal medicine and electroacupuncture.

  • PDF

A study on the Conversion Loss by the Thickness of the Bonding Medium in the Elastic Delay Lines. (탄성파지연선에서 접착제의 두께에 의한 변환손실에 관하여)

  • 김종상;이전영
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.6
    • /
    • pp.1-6
    • /
    • 1976
  • In this paper, the methode of calculating conversion loss is proposed by considering the thickness of bonding medium between electrode and delay material in the vibrator of Elastic delay lines. As the result of computations using digital computer, it is shown that the thickness of bonding medium must be less than about 1/100 of the thickness of vibrator and when the thickness of electrode is about 1110 of vibrator, the center fnequency is shifted. When the thickness of bonding medium is equal to or more than the thickness of vibrator, the 리uctuations in frequency Bandwidth become larger and larger.

  • PDF

Effects of Magnetic Powder Thickness on Electromagnetic Wave Absorption Characteristics in FeSiCr Flakes/Polymer Composite Sheets (FeSiCr 박편/폴리머 복합시트의 전자파 흡수 특성에 미치는 자성분말 두께의 영향)

  • Kim, Ju-Beom;Noh, Tae-Hwan
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.866-872
    • /
    • 2009
  • The effects of magnetic powder thickness on electromagnetic wave absorption characteristics in Fe-6.5Si-0.9Cr (wt%) alloy flakes/polymer composite sheets available for quasi-microwave band have been investigated. The atomized FeSiCr powders were milled by using attritor for 12, 24, and 36 h, powder thickness changed from $40{\mu}m$ to $3{\mu}m$ upon 36 h milling. The composite sheet, including thinned magnetic flakes, exhibited higher power loss in the GHz frequency range as compared with the sheets having thick flakes. Moreover, both the complex permeability and the loss factor increased with the decrease in thickness of the alloy flakes. Therefore, the enhanced power loss property of the sheets containing thin alloy flakes was attributed to the flakes of high complex permeability, especially their imaginary part. Additionally, the complex permittivity was also increased with the reduction of flake thickness, and this behavior was considered to be helpful for improvement of the electromagnetic wave absorption characteristics in the composite sheets, including thin alloy flakes.

Finite-element analysis of the shift in center of resistance of the maxillary dentition in relation to alveolar bone loss (치조골 상실에 따른 상악 치아군 저항중심의 변화에 관한 유한요소해석)

  • Sung, Sang-Jin;Kim, In-Tai;Kook, Yoon-Ah;Chun, Youn-Sic;Kim, Seong-Hun;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.278-288
    • /
    • 2009
  • Objective: The aim of this study was to investigate the changes in the center of resistance of the maxillary teeth in relation to alveolar bone loss. Methods: A finite element model, which included the upper dentition and periodontal ligament, was designed according to the amount of bone loss (0 mm, 2 mm, 4 mm). The teeth in each group were fixed with buccal and lingual arch wires and splint wires. Retraction and intrusion forces of 200 g for 4 and 6 anterior teeth groups and 400 g for the full dentition group were applied. Results: The centers of resistance were at 13.5 mm, 14.5 mm, 15 mm apical and 12 mm, 12 mm, 12.5 mm posterior in the 4 incisor group; 13.5 mm, 14.5 mm, 15 mm apical and 14 mm, 14 mm, 14.5 mm posterior in the 6 anterior teeth group; and 11 mm, 13 mm, 14.5 mm apical and 26.5 mm, 27 mm, 25.5 mm posterior in the full dentition group respectively according to 0 mm, 2 mm, 4 mm bone loss. Conclusions: The center of resistance shifted apically and posteriorly as alveolar bone loss increased in 4 and 6 anterior teeth groups. However, in the full dentition group, the center of resistance shifted apically and anteriorly in the 4 mm bone loss model.

Factors Affecting Research Participation of Bereaved Families of Terminal Cancer Patients: A Prospective Preliminary Study

  • Kim, Ye Won;Lee, Yuntaek;Hwang, In Cheol;Hwang, Sun Wook;Kim, Hyo Min;Shim, Jae Yong;Choi, Youn Seon;Lee, Yong Joo
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.3
    • /
    • pp.233-239
    • /
    • 2016
  • Purpose: Little is known regarding the factors associated with the willingness of family caregivers of terminal cancer patients to participate in a bereaved survey. This study aimed to ascertain the pre-loss factors that predict actual participation in a bereaved survey. Methods: We conducted a prospective observational study using data from two multi-center surveys at the end-of-life and after loss. In order to identify the pre-loss factors associated with participating in the bereaved survey, we used a step-wise multivariate logistic regression analysis. Results: Among 185 bereaved individuals, 30 responded to the survey (response rate: 16.2%). There were differences between the participation group and the non-participation group regarding religion, economic status, and perceived quality of care as assessed by the Quality Care Questionnaire-End of Life. A final multivariate model revealed that bereaved individuals who professed a religion (adjusted odds ratio [aOR]=5.01; P=0.008), had a high income (aOR=4.86, P=0.003), and satisfied with the care for familial relationship (aOR=4.49, P=0.003) were more likely to engage in the bereaved survey. Conclusion: Our finding suggests that improving the quality of end-of-life care may promote actual participation in a bereaved survey through easing post-loss distress. More attention should also be paid to those bereaved individuals who are hesitant to participate in a bereaved survey.

Electrical Loss Reduction in Crystalline Silicon Photovoltaic Module Assembly: A Review

  • Chowdhury, Sanchari;Kumar, Mallem;Ju, Minkyu;Kim, Youngkuk;Han, Chang-Soon;Park, Jinshu;Kim, Jaimin;Cho, Young Hyun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.7 no.4
    • /
    • pp.111-120
    • /
    • 2019
  • The output power of a crystalline silicon (c-Si) photovoltaic (PV) module is not directly the sum of the powers of its unit cells. There are several losses and gain mechanisms that reduce the total output power when solar cells are encapsulated into solar modules. Theses factors are getting high attention as the high cell efficiency achievement become more complex and expensive. More research works are involved to minimize the "cell-to-module" (CTM) loss. Our paper is aimed to focus on electrical losses due to interconnection and mismatch loss at PV modules. Research study shows that among all reasons of PV module failure 40.7% fails at interconnection. The mismatch loss in modern PV modules is very low (nearly 0.1%) but still lacks in the approach that determines all the contributing factors in mismatch loss. This review paper is related to study of interconnection loss technologies and key factors contributing to mismatch loss during module fabrication. Also, the improved interconnection technologies, understanding the approaches to mitigate the mismatch loss factors are precisely described here. This research study will give the approach of mitigating the loss and enable improvement in reliability of PV modules.

Utilization of Electrical Conductivity to Improve Prediction Accuracy of Cooking Loss of Pork Loin

  • Kyung Jo;Seonmin Lee;Hyun Gyung Jeong;Dae-Hyun Lee;Sangwon Yoon;Yoonji Chung;Samooel Jung
    • Food Science of Animal Resources
    • /
    • v.43 no.1
    • /
    • pp.113-123
    • /
    • 2023
  • This study investigated the predictability of cooking loss of pork loin through relatively easy and quick measurable quality properties. The pH, color, moisture, protein content, and cooking loss of 100 pork loins were measured. The explanatory variables included in all linear regression models with an adjust-r2 value of ≥0.5 were pH and the protein content. In the linear regression model predicting cooking loss, the highest adjust-r2 value was 0.7, with pH, CIE L*, CIE b*, moisture, and protein content as the explanatory variables. In 30 pork loins, electrical conductivity was additionally measured, and as a result of linear regression analysis for predicting cooking loss, the highest adjust-r2 value was 0.646 with electrical conductivity measured at 40 Hz, with pH and color as the explanatory variables. Ordinal logistic regression analysis was performed to predict the three grades (low, middle, and high) of loin cooking loss using pH, color, and 40 Hz electrical conductivity as the explanatory variables, and the percent concordance was 93.8%. In conclusion, the addition of electrical conductivity as an explanatory variable did not increase the prediction accuracy of the linear regression model for predicting cooking loss; however, it was demonstrated that it is possible to predict and classify the cooking loss grade of pork loin through quality properties that can be measured quickly and easily.

Effect of tranexamic acid on blood loss reduction in patients undergoing orthognathic surgery under hypotensive anesthesia: a single-center, retrospective, observational study

  • Keisuke Harada;Noritaka Imamachi;Yuhei Matsuda;Masato Hirabayashi;Yoji Saito;Takahiro Kanno
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.2
    • /
    • pp.86-93
    • /
    • 2024
  • Objectives: Orthognathic surgery is a surgical procedure performed by intraoral approach with established and safe techniques; however, excessive blood loss has been reported in rare cases. In response, investigative efforts to identify methods to reduce the amount of blood loss have been made. Among such methods, the administration of tranexamic acid was reported to reduce the amount of intraoperative blood loss. However, few studies to date have reported the effect of tranexamic acid in orthognathic surgery under hypotensive anesthesia. The present study aimed to investigate the effect of the administration of tranexamic acid on intraoperative blood loss in patients undergoing bimaxillary (maxillary and mandibular) orthognathic surgery under hypotensive anesthesia. Patients and Methods: A total of 156 patients (mean age, 27.0±10.8 years) who underwent bimaxillary orthognathic surgery under hypotensive anesthesia performed by the same surgeon between June 2013 and February 2022 were included in this study. The following data were collected from the medical records of each patient: background factors (age, sex, and body mass index), use of tranexamic acid, surgical procedures, previous medical history, duration of surgery, American Society of Anesthesiology physical status findings before surgery, intraoperative blood loss as a primary outcome, in-out balance, and blood test results. Descriptive statistics were calculated for statistical analysis, and a t-test and the chi-squared test were used for between-group comparisons. Group comparisons were performed after 1:1 propensity score matching to adjust for confounding factors. Statistical significance was set at P<0.05. Results: Comparison between the groups based on the use of tranexamic acid revealed a significant difference in operation time. Propensity score matching analysis revealed that intraoperative blood loss was significantly lower in the tranexamic acid group. Conclusion: The administration of tranexamic acid was effective in reducing intraoperative blood loss in patients undergoing bimaxillary orthognathic surgery under hypotensive anesthesia.