• 제목/요약/키워드: Cemented Stem

검색결과 16건 처리시간 0.016초

인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석 (Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods)

  • 조철형;조용균;최재봉;최귀원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

Biomechanical Finite Element Analysis of Bone Cemented Hip Crack Initiation According to Stem Design

  • Kim, Byeong-Soo;Moon, Byung-Young;Park, Jung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2168-2177
    • /
    • 2006
  • The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.

Periprosthetic Fracture around a Cemented Stem in Total Hip Arthroplasty

  • Jun-Young Heu;Ju-Yeong Kim;Se-Won Lee
    • Hip & pelvis
    • /
    • 제34권3호
    • /
    • pp.140-149
    • /
    • 2022
  • The increase in the number of primary total hip arthroplasties that will be performed over the next several decades will lead to an increase in the incidence of periprosthetic fractures around the femoral stem. A search of targeted articles was conducted using on-line databases of PubMed (National Library of Medicine) and articles were obtained from January 2008 to November 2021. Reliable prediction of treatment can be achieved using the Vancouver classification; internal fixation is indicated in fractures involving a stable implant and revision arthroplasty is indicated in those with unstable prostheses. To the best of our knowledge, relatively fewer studies regarding periprosthetic proximal femur fractures of cemented stems have been reported. The focus of this review is on the risk factors and strategies for treatment of these fractures for periprosthetic femoral fractures around a cemented hip arthroplasty.

Does humeral fixation technique affect long-term outcomes of total shoulder arthroplasty?

  • Troy Li;Kenneth H. Levy;Akiro H. Duey;Akshar V. Patel;Christopher A. White;Carl M. Cirino;Alexis Williams;Kathryn Whitelaw;Dave Shukla;Bradford O. Parsons;Evan L. Flatow;Paul J. Cagle
    • Clinics in Shoulder and Elbow
    • /
    • 제26권3호
    • /
    • pp.245-251
    • /
    • 2023
  • Background: For anatomic total arthroscopic repair, cementless humeral fixation has recently gained popularity. However, few studies have compared clinical, radiographic, and patient-reported outcomes between cemented and press-fit humeral fixation, and none have performed follow-up for longer than 5 years. In this study, we compared long-term postoperative outcomes in patients receiving a cemented versus press-fit humeral stem anatomic arthroscopic repair. Methods: This study retrospectively analyzed 169 shoulders that required primary anatomic total shoulder arthroplasty (aTSA). Shoulders were stratified by humeral stem fixation technique: cementation or press-fit. Data were collected pre- and postoperatively. Primary outcome measures included range of motion, patient reported outcomes, and radiographic measures. Results: One hundred thirty-eight cemented humeral stems and 31 press-fit stems were included. Significant improvements in range of motion were seen in all aTSA patients with no significant differences between final cemented and press-fit stems (forward elevation: P=0.12, external rotation: P=0.60, and internal rotation: P=0.77). Patient reported outcome metrics also exhibited sustained improvement through final follow-up. However, at final follow-up, the press-fit stem cohort had significantly better overall scores when compared to the cemented cohort (visual analog score: P=0.04, American Shoulder and Elbow Surgeon Score: P<0.01, Simple Shoulder Test score: P=0.03). Humeral radiolucency was noted in two cemented implants and one press-fit implant. No significant differences in implant survival were observed between the two cohorts (P=0.75). Conclusions: In this series, we found that irrespective of humeral fixation technique, aTSA significantly improves shoulder function. However, within this cohort, press-fit stems provided significantly better outcomes than cemented stems in terms of patient reported outcome scores. Level of evidence: III.

대퇴골 근위부 골흡수가 인공 고관절 대퇴 stem에 미치는 응력에 관한 연구-FEM을 이용한 분석 (A Finite Element Analysis of Stress on the Femoral Stem with Resorption of Proximal Medial Femur after Total Hip Replacement)

  • 김성곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.183-188
    • /
    • 1994
  • In clinical orthopaedics, bone resoption in the cortex is often seen post operatively on X-rays or bone densitometry after total hip replacement (THR) in the form of cortical osteoporosis or atropy. Stress shielding of bone occurs, when a load, normally carried by the bone alone, is shared with an implant as a result, the bone stresses are abnormal and with remodelling analysis this may cause extensive proximal bone resoption, possibly weakening the bone bed to the point of failure. The author made finite element models of the cemented and non-cemented type implanted femoral stem with bone resorption of the proximal medial femur and studied the feed back effect of the various degree of bone resoption to THR system by parametric analysis on the stress of the femoral stem and interface. The results of the present finite element analysis implied that the extent of proximal bone resorption has the effect of more increasing stress on the distal stem tip, cement mantle and interface in both type of femoral stem and this high distal stress possibly can cause the mechanical failure of loosening or failure after THR.

  • PDF

시멘트-대퇴Stem 경계면 해리가 골-시멘트 경계면에 미치는 응력 분석 -3차원 비선형 Finite Element Analysis- (Stress analysis of the effect of debonding of cement-femoral stem interface to the bone-cement interface -A three-dimensional Finite Element Analysis-)

  • 김성곤
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.337-346
    • /
    • 1996
  • Debonding of cement-femoral stem interface has been suggested as a initial focus of loosening mechanism in many previous studies of cemented total hip replacement. The purpose of this study was to investigate the effect of debonding of cement-femoral stem interface to the bone-cement interface by using three-dimensional non-liner finite element analysis. Three cases of partial debonded, full debonded, full bonded cement-bone interface were modelled with partial bonding of distal 70mm from the tip of femoral stem. Each situation was studied under loading stimulating one-leg stanced gait of 68kg patient. The results showed that under partial and full debonded cement-stem interface condition the peak von Mises stress(3.1 MPa) were observed at the cement of bone-cement interface just under the calcar of proximal medial of femur, and sudden high peak stresses(3.5MPa) were developed at the distal tip of femoral stem at the lateral bone-cement interface in all 3 cases of bonding. The stresses were transfered very little to the cement of upper lateral bone-cement interface in partial and full debonded cases. Thus, once partial or full debonded cement-femoral stem interface occured, 3 times higher stress concentration were developed on the cement of proximal medial bone-cement interface than full bonded interface, and these could cause loosening of cemented total hip replacement. Clinically, preservation of more rigid cement-femoral stem interface may be important factor to prevent loosening of femoral stem.

  • PDF

Comparison between Cementless and Cemented Bipolar Hemiarthroplasty for Treatment of Unstable Intertrochanteric Fractures: Systematic Review and Meta-analysis

  • Yoo, Jun-Il;Cha, Yong-Han;Kim, Kap-Jung;Kim, Ha-Yong;Choy, Won-Sik;Hwang, Sun-Chul
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.241-253
    • /
    • 2018
  • Purpose: This study was conducted to compare cemented and cementless bipolar hemiarthroplasty in elderly patients with unstable intertrochanteric fractures via meta-analysis and systematic review of relevant studies. Materials and Methods: Systematic review and meta-analysis were performed on 31 available clinical studies; 19 of these studies used cemented stems, 12 used cementless stems, one used both types of stems, and two studies involved a comparative analysis of both stem types. Results: There were statistically significant differences in rates of leg length discrepancy (LLD) greater than 1 cm between the cemented (event rate, 0.089) and cementless groups (event rate, 0.015 and 0.047; P=0.03). Conclusion: Cemented bipolar hemiarthroplasty and cementless bipolar hemiarthroplasty performed on elderly patients with unstable intertrochanteric fracture revealed similar mortality and complication rates; however, the rate of LLD greater than 1 cm was significantly higher in the cemented group compared with the cementless group.

인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구 (A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact)

  • 조용균;조철형;최재봉;이태수;최귀원
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권5호
    • /
    • pp.503-511
    • /
    • 1998
  • 본 연구에서는 동적충격하중 하에서 다양한 tibial component system의 하중전달현상 및 발생 가능한 실패기전을 관찰하기 위해 서로 다른 tibial component들에 대한 수치해석을 통한 응력분포를 관찰하고 또한 접합 상태에 따른 임플란트 시스템이 받는 영향을 비교 분석하였다. 따라서, 해석에 고려되는 모델은 정상 경골과 현재 가장 많이 적용되는 시스템인 시멘트형과 무시멘트형 metal-backed tibial component, 폴리에틸렌으로 된 시멘트형 tibial component, 그리고 골과 slew사이의 비접합상태를 가정한 metal-backed tibial component을 포함한다. 해석 결과 metal-backed tibial component의 stem 끝 부분에서는 시멘트형이 무시멘트형 보다 약간 더 놀은 최대 응력을 보였다. 반면, 폴리에틸렌으로 된 tibial component의 경우 stem 글 부분에서의 최대 응력은 metal-backed tibial component에 비해 차 반 정도로 줄었고, 전체적으로 정상 경골에 유사한 응답 특성을 보여주었다. 골과 stem 사이의 비접합을 가정한 경우 금속 tray 밑 부된에서의 응력은 완전히 접합된 경우 보다 3배 더 높았고, stem 끝부분에서는 시간에 따른 불안정한 응력이 관찰되어 이 현상은 임플란트 해리현상과 불완전한 골접합을 가중시키는 원인으로 사료된다. 따라서, 수직충격하중을 고려한 경우 골에 안정하게 고정되는 폴리에틸렌 tibial component가 가장 바람직하다.

  • PDF

FEM 3차원 모델을 이용한 인공관절 대퇴 Stem 경계면의 미세운동 분석 (A Three-Dimensional Finite Element Study of Interface Micromotion in a Non-Cement Total Hip stem)

  • 김성곤;최형연;채수원
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.61-70
    • /
    • 1996
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony inyowth and secondary long term fixation. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone stem interface. An accurate evaluation of interf'ace micromotion and stress/strain fields in the bone-implant system may be relevant for better understanding of clinical situations and improving THA design. Recently finite element method(FEM) was introduced in'orthopaedic research field due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional finite element model of proximal femur with $Multilock^{TM}$ stem of 1179 blick elements to analyse the micromotions and mechanical behaviors at the bone-stem inteface in early post-operative period for the load simulating single leg stance. The results indicates that the values of relative motion for this well fit stem were $150{\mu}m$ in maximum $82{\mu}m$ in minimum and the largest relative motion was developed in medial region of Proximal femur and in anterior-posterior direction. The motion in the proximal bone was much greater than in the distal bone and the stress pattern showed high stress concentration on the cortex near the tip of the stem. These findings indicate that the loading on the hip joint in the early postoperative situation before achieving bony ingrowth could produce large micromotion of $150{\mu}m$ and clinicaly non-cemented THA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF

Stress Analysis of Femoral Stems on Non-Cemented Total Hip Replacement - A Three-Dimensional Finite Element Analysis -

  • Kim, Sung-Kon;Chae, Soo-Won;Jeong, Jung-Hwan
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.263-266
    • /
    • 1997
  • Three dimensional numerical model based on the finite element method(FEM) were developed to predict the mechanical behavior of hip implants. The purpose of this study is to investigate the stress distribution of two types of cementless total hip replacement femoral component -a straight stem and a curved stem, and to compare their effect on the stress shielding between two types by three dimensional finite element method. The authors analyzed von Mises stress in the cortex & stem and compared the stress between the straight and the curved stem. In comparison of stresses between two different design of femoral stem, there was 25% more decrease of stress in straight stem than curved stem in the medial cortex at proximal region. The straight stem had consistently much lower stresses than the curved stem throughout the whole medial cortex with maximum 70% reduction of stress. However, there was little change in stress between nature and 2 implanted femur throughout the lateral cortex. Stress of femoral stem was much higher in the straight stem than the curved stem up to 60%. The straight stem had more chance of stress shielding and a risk of fatigue fracture of the stem compared with the curved stem in noncement hip arthroplasty. In design of femoral stem still we have to consider to develop design to distribute more even stress on the proximal medial cortex.

  • PDF