• 제목/요약/키워드: Cell-chip

검색결과 464건 처리시간 0.025초

Quantitative and Rapid Analysis of Transglutaminase Activity Using Protein Arrays in Mammalian Cells

  • Kwon, Mi-Hye;Jung, Jae-Wan;Jung, Se-Hui;Park, Jin-Young;Kim, Young-Myeong;Ha, Kwon-Soo
    • Molecules and Cells
    • /
    • 제27권3호
    • /
    • pp.337-343
    • /
    • 2009
  • We developed a novel on-chip activity assay using protein arrays for quantitative and rapid analysis of transglutaminase activity in mammalian cells. Transglutaminases are a family of $Ca^{2+}$-dependent enzymes involved in cell regulation as well as human diseases such as neurodegenerative disorders, inflammatory diseases and tumor progression. We fabricated the protein arrays by immobilizing N,N'-dimethylcasein (a substrate) on the amine surface of the arrays. We initiated transamidating reaction on the protein arrays and determined the transglutaminase activity by analyzing the fluorescence intensity of biotinylated casein. The on-chip transglutaminase activity assay was proved to be much more sensitive than the $[^3H]putrescine$-incorporation assay. We successfully applied the on-chip assay to a rapid and quantitative analysis of the transglutaminase activity in all-trans retinoic acid-treated NIH 3T3 and SH-SY5Y cells. In addition, the on-chip transglutaminase activity assay was sufficiently sensitive to determine the transglutaminase activity in eleven mammalian cell lines. Thus, this novel on-chip transglutaminase activity assay was confirmed to be a sensitive and high-throughput approach to investigating the roles of transglutaminase in cellular signaling, and, moreover, it is likely to have a strong potential for monitoring human diseases.

바이오소자 기술 (Biodevice Technology)

  • 최정우;이범환
    • Korean Chemical Engineering Research
    • /
    • 제44권1호
    • /
    • pp.1-9
    • /
    • 2006
  • 생물체를 구성하는 세포의 기능과 구성요소 간 상호작용 메커니즘을 인공적으로 모방하여 바이오물질 박막으로 구성된 바이오소자는 의료 진단, 신약 스크리닝, 전자소자, 생물공정, 환경오염 물질 측정 등 다양한 산업 분야에 응용되고 있다. 단백질, DNA, 바이오색소, 세포 등의 생체물질을 칩 상에 고집적으로 배열하여 구성된 바이오 소자로서 바이오 전자소자(생물분자 광다이오드, 바이오 정보저장소자, 바이오 전기발광 소자), DNA칩, 단백질칩, 및 세포칩 등이 개발되어 오고 있다. 생체물질 고정화 기술, 마이크로 및 나노수준의 패터닝기술, 소자 구성 기술, 바이오 멤스 기술의 융합을 통해 바이오소자는 구현되며, 최근에는 나노기술의 적용에 의하여 나노바이오소자도 구현이 가능하다. 본 논문에서는 현재까지 개발된 다양한 바이오소자의 제작 기술과 응용에 대하여 소개하고 향후의 발전 방향에 대하여 다룬다.

CATV 망용 고속 비대칭 기저대역 모뎀 ASIC 칩 설계 (Design of a High Speed Asymmetric Baseband MODEM ASIC Chip for CATV Network)

  • 박기혁
    • 한국통신학회논문지
    • /
    • 제25권9A호
    • /
    • pp.1332-1339
    • /
    • 2000
  • 본 논문에서는 MCNS(Multimedia Cable N$\xi$twork System)의 DOCSIS(Data Over Cable Service Interface S Specification) 표준안의 물리계층을 지원하는 비대칭형 기저대역 모댐 ASIC 칩의 아키텍쳐와 설계에 대해 기술한다. 구현한 모뎀 칩은 크게 QPSK/16-QAM 방식의 상향 스트림용 송신부와 64/256-QAM 방식의 하향 스트림용 수신부로 구성되어 있으며, 심볼 타이밍 복구회로, 반송파 복구회로. MMA(Multi Modulus Algorithm)와 LMS(Least Mean Square) 알고리즘을 적용한 결정 궤환 구조의 블라인드 등화기를 포함한다. 구현한 모뎀 칩은 64/256-QAM 변복조 방식에서 각각 48Mbps, 64Mbps의 데이터 전송률을 지원하고, 심볼 전송률은 기존의 QAM 수신기들보다 빠른 8MBaud를 갖는다. 구현한 칩은 $0.35\mu\textrm{m}$ 표준 셀(Standard Cell) 라이브러리를 사용하여 논리합성을 수행하였으며, 총 게이트 수는 약 29만 게이트이며, 현재 ASIC 칩으후 제작중이다.

  • PDF

Effect of Shield Line on Noise Margin and Refresh Time of Planar DRAM Cell for Embedded Application

  • Lee, Jung-Hwan;Jeon, Seong-Do;Chang, Sung-Keun
    • ETRI Journal
    • /
    • 제26권6호
    • /
    • pp.583-588
    • /
    • 2004
  • In this paper we investigate the effect of a shield metal line inserted between adjacent bit lines on the refresh time and noise margin in a planar DRAM cell. The DRAM cell consists of an access transistor, which is biased to 2.5V during operation, and an NMOS capacitor having the capacitance of 10fF per unit cell and a cell size of $3.63{\mu}m^2$. We designed a 1Mb DRAM with an open bit-line structure. It appears that the refresh time is increased from 4.5 ms to 12 ms when the shield metal line is inserted. Also, it appears that no failure occurs when $V_{cc}$ is increased from 2.2 V to 3 V during a bump up test, while it fails at 2.8 V without a shield metal line. Raphael simulation reveals that the coupling noise between adjacent bit lines is reduced to 1/24 when a shield metal line is inserted, while total capacitance per bit line is increased only by 10%.

  • PDF

표준 셀 라이브러리 P&R 포팅과 테스트 칩의 설계 (P&R Porting & Test-chip implementation Using Standard Cell Libraries)

  • 임호민;김남섭;김진상;조원경
    • 한국항행학회논문지
    • /
    • 제7권2호
    • /
    • pp.206-210
    • /
    • 2003
  • 본 논문에서는 최신의 미세공정인 0.18um CMOS 공정을 이용한 표준 셀 라이브러리를 설계하고, 이를 P&R(Placement and Routing) CAD 툴에 사용할 수 있도록 포팅한다. 제작결과를 검증하기 위하여 간단한 테스트칩을 제작하였으며 설계에 사용된 표준 셀 라이브러리는 0.18um 아남반도체의 공정이다. 이러한 설계 및 제작과정을 통하여 최신의 미세공정을 이용하여 디지털 시스템의 자동설계가 가능함을 확인하였다.

  • PDF

Detection of Bacillus Cereus Using Bioluminescence Assay with Cell Wall-binding Domain Conjugated Magnetic Nanoparticles

  • Park, Chanyong;Kong, Minsuk;Lee, Ju-Hoon;Ryu, Sangryeol;Park, Sungsu
    • BioChip Journal
    • /
    • 제12권4호
    • /
    • pp.287-293
    • /
    • 2018
  • Bacillus cereus can cause blood infections (i.e., sepsis). Its early detection is very important for treating patients. However, an antibody with high binding affinity to B. cereus is not currently available. Bacteriophage cell wall-binding domain (CBD) has strong and specific binding affinity to B. cereus. Here, we report the improvement in the sensitivity of an ATP bioluminescence assay for B. cereus detection using CBD-conjugated magnetic nanoparticles (CBD-MNPs). The assay was able to detect as few as 10 colony forming units (CFU) per mL and $10^3CFU\;per\;mL$ in buffer and blood. CBD-MNPs did not show any cross-reactivity with other microorganisms. These results demonstrate the feasibility of the ATP assay for the detection of B. cereus.

다수의 전기장 분포가 생성되는 단일 미세유로를 이용한 폐암세포 전기천공 및 활성도 분석칩 (Electroporation and Viability Monitoring Chip for Lung Cancer Cells in Single Channel with Multiple Electric Field Zones)

  • 김민지;김태윤;조영호
    • 대한기계학회논문집B
    • /
    • 제36권9호
    • /
    • pp.901-905
    • /
    • 2012
  • 본 논문에서는 다수의 전기장 분포가 생성되는 단일 미세유로를 이용한 폐암세포 전기천공 및 활성도 분석칩을 제안하였다. 종래의 세포 전기천공 분석칩은 다수의 전기장 분포를 형성하기 위해 다수의 전극패턴 또는 다수의 미세유로를 필요로 하여 구조가 복잡하였다. 반면, 제안된 세포 전기천공 및 활성도 분석칩은 한 쌍의 전극 사이에서 계단 형상으로 폭이 변화하는 단일 미세유로를 이용하여 다수의 전기장 분포를 형성함으로써 간단한 구조로 세포 전기천공 및 활성도를 분석할 수 있다. 제안된 세포 전기천공 및 활성도 분석칩은 0.3kV/cm에서 0.5kV/cm까지 5단계의 전기장이 발생되도록 설계하였다. A549와 H23의 두 종류의 비소세포 폐암세포주를 이용한 성능실험 결과, 활성을 유지하면서 전기천공된 세포의 비율이 0.4kV/cm의 전기장에서 각각 $26.6{\pm}0.7%$$51.4{\pm}3.0%$로 가장 높은 값을 보였다. 제안된 세포 전기천공 및 활성도 분석칩은 세포의 형질주입 연구를 위한 집적화된 세포칩으로 응용될 수 있다.

Chip소자를 이용한 SSPA 설계 및 제작에 관한 연구 (The Design and Implementation of SSPA(Solid State Power Amplifier) using chip device)

  • 김용환;민준기;김현진;유형수;이형규;홍의석
    • 한국ITS학회 논문지
    • /
    • 제2권2호
    • /
    • pp.65-72
    • /
    • 2003
  • 본 연구를 통하여 MMC(Microwave Micro Cell)를 위한 무선 중계 시스템과 ITS용 무선장비등에 사용 될 수있는 6단의 하이브리드 전력증폭기를 설계 및 제작하였다. 전력 증폭기 각단의 능동소자는 bare chip 형태의 Hetero-junction Power FET를 이용하였으며, $\varepsilon_{r}$=9.9, 15-mil 두께의 알루미나기판을 사용하여 제작하였다. 측정 결과 시스템의 순방향 주파수인 17.6GHz - 17.gGEU에서 33.2~36.5dB의 소신호 이득과 33.0$\~$34.0dBm까지의 출력전력을 얻었고, 역방향 주파수인 19.0GHt$\~$19.2GHz에서 36.0$\~$37.0dB의 소신호 이득을 출력전력은 33.0$\~$34.5dBm을 얻었다.

  • PDF

대용량 EEPROM 메모리 셀 검증용 모듈 회로 설계 (Design of a Cell Verification Module for Large-density EEPROM Memories)

  • 박헌;김일준;하판봉;김영희
    • 한국정보전자통신기술학회논문지
    • /
    • 제10권2호
    • /
    • pp.176-183
    • /
    • 2017
  • 대용량 EEPROM 메모리를 테스트하는 경우 erase time과 program time이 많이 걸리는 문제가 있다. 또한 신뢰성 테스트를 진행하면서 각 스텝마다 EEPROM 셀의 문턱전압 VT를 테스트할 필요가 있다. 본 논문에서는 512kb EEPROM 셀 검증용 모듈 회로를 설계하였으며, negative VTE를 갖는 split gate EEPROM의 VT 측정을 위한 CG(Control Gate) 구동회로를 제안하였다. 제안된 CG 구동회로는 erase VT를 측정하기 위해 -3V~0V의 negative 전압이 인가될 수 있도록 asymmetric isolated HV (High-Voltage) NMOS 소자를 사용하였다. 그리고 test time reduction 모드에서는 even page, odd page, chip 단위로 erase나 program 수행이 가능하도록 회로를 설계하므로 512Kb EEPROM 전체 메모리를 erase하거나 program할 때 시간을 even page와 odd page를 이용하는 경우는 4ms, chip 전체로 하는 경우는 2ms로 테스트 시간을 줄일 수 있었다.

DSP 칩과 최적분별법을 이용한 새로운 혈구입자 계수기 설계 (A New Design of Blood Cell Counter using DSP chip and Optimal Discrimination Method)

  • 김규학;김종원;김근섭;홍완희;김성환
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 춘계학술대회
    • /
    • pp.89-93
    • /
    • 1991
  • The purpose of this reserch is to design the blood cell counting instrument which can measure the number of RBC(Red Blood Cell) and WBC(White Blood Cell) including many other blood component. The proposed method uses the electrical impedence method and the new discrimination method wi th DSP chip and software algorithm. The system consist of control unit, blood cell discrimination unit, hemoglobin spectrometer, post detect ion processor unit, and IBM-PC interface unit. In this paper, the discrimination system has been implemented using digital signal processor, which result in the reduction of system hardware and cost. The system is helpful in providing necessary clinical test for screen test and quality control of hematology.

  • PDF