• Title/Summary/Keyword: Ceiling Board

Search Result 30, Processing Time 0.024 seconds

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Analysis of Noise Environment of Cafe Occupants According to Interior Finishing (실내 인테리어 마감재에 따른 카페 재실자의 소음 환경 영향 분석)

  • Lee, Soo Han;Yun, Huiseung;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.4
    • /
    • pp.355-361
    • /
    • 2017
  • Indoor noise environment is an important factor when it comes to occupants comfort, especially in cafe. Results of the survey, 33.9% of occupants were feel unpleasant and sensitive about noise environment. Noise in cafe fluctuate depending on the finishing of both wall and ceiling, volume of the room, and the number of occupants in the room. Therefore, the noise meter device was used for measurement of various under conditions. Also, the subjective assessment of occupant noise was conducted through questionnaires. When the interior finish was exposed concrete, the maximum value of the noise measurement was 66.6 dB and the minimum value was 63 dB, respectively. Also, the result of subjective assessment of unpleasant noise were 5.43 and 4.96 point of 10 point of noise and echo, respectively. Otherwise, the interior finish was gypsum board, the maximum value of the noise measurement was 73.8 dB and the minimum value was 60.4 dB, respectively. Also, the result of subjective assessment of unpleasant noise were 3.88 and 3.95 point of 10 point of noise and echo, respectively. The results of the study showed that the noises and echoes in the cafes were lower than when did not.

Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto (황토를 이용한 친환경 유공 흡음보드의 흡음특성)

  • Kim, Sun-Woo;Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

Construction History of the Old House "IMCHEONGGAK" in Andong and Estimation of its Original Structure -Focused on the 'Inner chamber' and the 'Sarang section'- (안동 "임청각(臨淸閣)"의 건축 이력과 원형 가구(架構) 추정 -사랑채와 안채를 중심으로-)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.2
    • /
    • pp.31-44
    • /
    • 2016
  • Imcheong-gak[臨淸閣] was a familial residence constructed in the early half of the Joseon dynasty period. It was partially destroyed by a fire during the 1590s war[壬辰倭亂] with the Japanese, and another fire that was caused between 1631 and 1634. The inner chamber[An-chae] and the Sarang section[Sarang-chae] today is the result of a partial reconstruction that took place back in 1626 and again around 1634. The residence also went through some changes because the new Ondol[溫突] heating system had to be applied to the structure. Based upon sections that remain in their original forms, we can presume that the Imcheong-gak residence originally had an inner chamber which was composed of the following elements: A main structure which was built upon a foundation featuring a Matbae[맞배] roof, two "Ik'rang[翼廊, flank]" sections on the East and West sides of the inner chamber, and a "Haeng'rang[行廊, passage]" structure on the opposite side of the main structure. Unlike the main structure, other portions of the inner chamber were all built directly upon the ground, and showed multiple stories, with Matbae roofs of their own. We can also assume that the Sarang section in the south would have been a pre-Ondol[溫突] bedroom, with a Board platform[板房] and a Gomi-ceiling[Gomi-banza] fashion.

Selection of Scale Model Materials for Acoustical Evaluation of 1:50 Multipurpose Halls (1:50 다목적홀의 음향평가를 위한 축소모형재료의 선정)

  • Jeon, Jin-Yong;Kim, Jeong-Jun;Kim, Yong-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.781-789
    • /
    • 2009
  • The absorption coefficients of the materials used in a 1:50 scale model multipurpose hall were measured based on ISO 354 and related laws. The shape and materials for the scale model were evaluated based on reflective surfaces, variable acoustic elements and sound-absorbing quality (125Hz-1kHz average) of seats. The measured average absorption coefficients of audience seats, audience and orchestra were 0.64, 0.74 and 0,45, respectively, which were simulated with the combination of wood, absorption materials and foam board. Various mounting methods for absorption curtain and banner were considered according to the installation methods. The average absorption coefficient was measured as 0.42, 0.47 and 0.45 in the conditions of Type A mounting, E mounting with 0.9 m backing air cavity, and Type G mounting which is suspended at the ceiling, respectively. It was confirmed that the absorption coefficient was increased at low frequency by backing air gap. The finishing material of stage house was an absorption material covered with thin fabric, which aimed average absorption coefficient of 0.68 by using fiber glass board. Each part of the real materials was compared with those of 1:50 scale model and it was found that the absorption characteristics of both cases were similar.

The Characteristics of Chinese Traditionality Expression in View of Spatial Elements at Restaurants in Beijing Area (베이징지역 레스토랑 공간구성요소에 나타난 중국 전통성 표현 특성 연구)

  • Yuan, DanDan;Oh, Hye Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.163-171
    • /
    • 2016
  • The objectives of this study is to analyze the characteristics of Chinese traditionality expression at restaurants in Beijing area. 12 restaurants were selected and visited for the investigation research. The results were as follows. First, traditional reproduction was found mainly manifested through the reproduction of traditional ornaments, in particular, the facade and interior element ornaments. Second, Traditional transformation was mainly manifested in replacement material while changing the shape slightly, or to stretch or shorten prototype shape and other negative deformation methods which did not largely out of the scope of traditional reproduction. Third, Traditional reinterpretation was expressed by abstract, symbol or metaphor on designs, usually people can not directly recognize the traditional archetype. When compare with traditional reproduction or traditional transformation, traditional reinterpretation was relatively fewer, however, in this study the traditional reinterpretation and traditional transformation have same numerical result. Reinterpretation as a positive performance method of traditional modernized, it was encouraging the phenomenon, especially in the ceiling design. Chinese traditional cloud patterns have been three-dimensional and diversification of use. And in the wall design, traditional elements have been extremely simplistic or adopted a wide variety of traditional elements, it may be preferred in diversity. In addition, furniture was tinge traditional elements in modern form, lighting was added symbolize color or picture on the traditional lighting which shape was simplified to emphasize space's traditional. But the facade, sign board, floor, and window element seems the range of variation was not wild, promote more use the positive traditional reinterpretation method.

Compatibility of the Direction Sign on the Pendant Switch of Overhead Cranes

  • Park, Jae Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.75-83
    • /
    • 2015
  • Objective: The aim of this study is to suggest the standard of the direction sign on the pendant switch of overhead cranes which can reduce human errors in control. Background: A great number of crane accidents occur in industries. One of the major causes of the accidents is the mistake in the control of cranes by confusing the orientation of crane movements. Nevertheless, three different direction sign styles, 'East, West, South, North (EWSN)', 'Forward, Backward, Left, Right (FBLR)', and arrows for four directions are used without standardization. Method: An overhead crane simulator was installed for a laboratory experiment. It could move along six directions by the control of a pendant switch. 90 participants were evenly assigned to the three different conditions of direction sign styles. The participants were asked to control the pendant switch according to the continuously appearing 16 direction signs on a monitor ahead. The participants were allowed to refer an orientation sign board on the ceiling representing correct movement directions of the overhead crane simulator. Results: The direction sign style, 'EWSN', showed statistically significant better performance in task completion time and number of errors than the other sign styles. The direction sign style, 'EWSN', adopting the cardinal direction system, made the participants clear in direction controls after customizing to the crane movements. However, the direction sign styles, 'FBLR' and the arrows adopting the relative direction system made conflicts in direction controls due to the egocentric view of human. Conclusion: The direction sign style, 'EWSN', is the most appropriate for the standardization of the direction sign on the pendant switch of overhead cranes. Application: The results of this study can be applied to the standardization of direction sign in the legal notification on the safety certifications of crane manufacturing.

Habitability evaluation considering various input parameters for main control benchboard fire in the main control room

  • Byeongjun Kim ;Jaiho Lee ;Seyoung Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4195-4208
    • /
    • 2022
  • In this study, operator habitability was numerically evaluated in the event of a fire at the main control bench board (MCB) in a reference main control room (MCR). It was investigated if evacuation variables including hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD) at 1.8 m from the MCR floor exceed the reference evacuation criteria provided in NUREG/CR-6850. For a fire model validation, the simulation results of the reference MCR were compared with existing experimental results on the same reference MCR. In the simulation, various input parameters were applied to the MCB panel fire scenario: MCR height, peak heat release rate (HRR) of a panel, number of panels where fire propagation occurs, fire propagation time, door open/close conditions, and mechanical ventilation operation. A specialized-average HRR (SAHRR) concept was newly devised to comprehensively investigate how the various input parameters affect the operator's habitability. Peak values of the evacuation variables normalized by evacuation criteria of NUREG/CR-6850 were well-correlated as the power function of the SAHRR for the various input parameters. In addition, the evacuation time map was newly utilized to investigate how the evacuation time for different SAHRR was affected by changing the various input parameters. In the previous studies, it was found that the OD is the most dominant variable to determine the MCR evacuation time. In this study, however, the evacuation time map showed that the HF is the most dominant factor at the condition of without-mechanical ventilation for the MCR with a partially-open false ceiling, but the OD is the most dominant factor for all the other conditions. Therefore, the method using the SAHRR and the evacuation time map was very useful to effectively and comprehensively evaluate the operator habitability for the various input parameters in the event of MCB fires for the reference MCR.

Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings (일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가)

  • Chung, Eun Kyo;Kim, Ki Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.

A Study on the Basic Investigation for the Fire Risk Assessment of Education Facilities (교육시설 화재위험성 평가를 위한 기초조사에 관한 연구)

  • Lee, Sung-Il;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.351-364
    • /
    • 2021
  • Purpose: Fire load analysis was conducted to secure basic data for evaluating fire risk of educational facilities. In order to calculate the fire load through a preliminary survey, basic data related to the fire load of school facilities were collected. Method: The basic data were the definition and types of fire loads, combustion heat data for the calculation of fire loads. The fire load was evaluated by multiplying the combustion heat by the weight of the combustibles in the compartment when calculating the fire load. Result: As for the fixed combustible materials of A-elementary school, the floor was mainly made of wood, in consideration of emotion and safety in the classroom, music room, and school office, and the rest of the compartments were made of stone. The ceiling and walls were made of gypsum board and concrete, so they were not combustible. The typical inflammable items in each room were desks, chairs, and lockers in the classroom, and the laboratory equipment box and experimental tool box were the main components in the science room, and books, bookshelves, and reading equipment occupied a large proportion in the library room. Conclusion: 'The fire loads of A-elementary' schools according to the combustibles loaded were in the order of library, computer room, English learning room, teacher's office, general classroom, science hall, and music room.